The SPHERE-2 detector for observation of extensive air showers in 1 PeV -- 1 EeV energy range
Authors:
R. A. Antonov,
E. A. Bonvech,
D. V. Chernov,
T. A. Dzhatdoev,
M. Finger Jr.,
M. Finger,
D. A. Podgrudkov,
T. M. Roganova,
A. V. Shirokov,
I. A. Vaiman
Abstract:
The SPHERE-2 balloon-borne detector designed for extensive air shower (EAS) observations using EAS optical Vavilov-Cherenkov radiation (``Cherenkov light''), reflected from the snow-covered surface of Lake Baikal is described. We briefly discuss the concept behind the reflected Cherenkov light method, characterize the conditions at the experimental site and overview the construction of the tethere…
▽ More
The SPHERE-2 balloon-borne detector designed for extensive air shower (EAS) observations using EAS optical Vavilov-Cherenkov radiation (``Cherenkov light''), reflected from the snow-covered surface of Lake Baikal is described. We briefly discuss the concept behind the reflected Cherenkov light method, characterize the conditions at the experimental site and overview the construction of the tethered balloon used to lift the SPHERE-2 telescope above the surface. This paper is mainly dedicated to a detailed technical description of the detector, including its optical system, sensitive elements, electronics, and data acquisition system (DAQ). The results of some laboratory and field tests of the optical system are presented.
△ Less
Submitted 24 December, 2019;
originally announced December 2019.
Status of the SPHERE experiment
Authors:
R. A. Antonov,
S. P. Beschapov,
E. A. Bonvech,
D. V. Chernov,
T. A. Dzhatdoev,
Mir. Finger,
M. Finger,
V. I. Galkin,
N. N. Kabanova,
A. S. Petkun,
D. A. Podgrudkov,
T. M. Roganova,
S. B. Shaulov,
T. I. Sysoeva
Abstract:
Here is presented the current state of the SPHERE-2 balloon-borne experiment. The detector is elevated up to 1 km above the snow surface and registers the reflected Vavilov-Cherenkov radiation from extensive air showers. This method has good sensitivity to the mass-composition of the primary cosmic rays due to its high resolution near the shower axis. The detector consists of a 1500 mm spherical m…
▽ More
Here is presented the current state of the SPHERE-2 balloon-borne experiment. The detector is elevated up to 1 km above the snow surface and registers the reflected Vavilov-Cherenkov radiation from extensive air showers. This method has good sensitivity to the mass-composition of the primary cosmic rays due to its high resolution near the shower axis. The detector consists of a 1500 mm spherical mirror with a 109 PMT cluster in its focus. The electronics record a signal pulse profile in each PMT. In the last 2 years the detector was upgraded: time resolution of pulse registration was enhanced up to 12.5 ns, channel sensitivity was increased by a factor of 3, a new LED-based relative PMT calibration method was introduced, and new hardware and etc. was installed.
△ Less
Submitted 4 October, 2012;
originally announced October 2012.