Evaluation of Coincidence Time Resolution in a liquid xenon detector with silicon photomultipliers
Authors:
N. Salor-Iguiñiz,
J. M. Benlloch-Rodríguez,
R. Esteve,
C. Romo-Luque,
R. J. Aliaga,
V. Álvarez,
F. Ballester,
R. Gadea,
F. Monrabal,
M. Querol,
M. Rappaport,
J. Rodríguez,
J. Rodríguez-Ponce,
S. Teruel-Pardo,
J. F. Toledo,
R. Torres-Curado,
P. Ferrario,
V. Herrero,
J. J. Gómez-Cadenas
Abstract:
This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first prototype optimized to maximize light collection using high-PDE, VUV-sensitive sensors and to minimize time fluctuations. We report a coincidence time resolution of 28…
▽ More
This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first prototype optimized to maximize light collection using high-PDE, VUV-sensitive sensors and to minimize time fluctuations. We report a coincidence time resolution of 281 $\pm$ 2 ps FWHM, obtained using a $^{22}$Na calibration source. This result is competitive with the current state-of-the-art PET scanners and represents a significant step forward in the development of liquid xenon as a viable alternative to conventional scintillators in PET technology.
△ Less
Submitted 9 December, 2024;
originally announced December 2024.
-
Measurement of the scintillation resolution in liquid xenon and its impact for future segmented calorimeters
Authors:
C. Romo-Luque,
J. M. Benlloch-Rodríguez,
V. Herrero-Bosch,
N. Salor-Iguiñiz,
R. J. Aliaga,
V. Álvarez,
F. Ballester,
R. Esteve,
R. Gadea,
J. Generowicz,
A. Laing,
F. Monrabal,
M. Querol,
M. Rappaport,
J. Rodríguez,
J. Rodríguez-Ponce,
S. Teruel-Pardo,
J. F. Toledo,
R. Torres-Curado,
P. Ferrario,
J. J. Gómez-Cadenas
Abstract:
We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimised to maximise light collection, and uses state-of-the-art, high-PDE, VUV-sensitive silicon photomultipliers. We find a value of 4.2% +- 0.2% FWHM at 511 keV, a result much better than previous measurements and close to the Poissonian resolut…
▽ More
We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimised to maximise light collection, and uses state-of-the-art, high-PDE, VUV-sensitive silicon photomultipliers. We find a value of 4.2% +- 0.2% FWHM at 511 keV, a result much better than previous measurements and close to the Poissonian resolution that we expect in our setup (5.4% +- 0.8% FWHM at 511 keV). Our results are compatible with a null value of the intrinsic energy resolution in liquid xenon, with an upper bound of 0.4% FWHM at 95% CL at 511 keV, to be compared with 3--4% FWHM in the same region found by theoretical estimations which have been standing for the last twenty years. Our work opens new possibilities for apparatus based on liquid xenon and using scintillation only. In particular it suggests that modular scintillation detectors using liquid xenon can be very competitive as building blocks in segmented calorimeters, with applications to nuclear and particle physics as well as Positron Emission Tomography technology.
△ Less
Submitted 26 January, 2023; v1 submitted 14 October, 2022;
originally announced October 2022.
-
Monte Carlo characterization of PETALO, a full-body liquid xenon-based PET detector
Authors:
J. Renner,
C. Romo-Luque,
R. J. Aliaga,
V. Álvarez,
F. Ballester,
J. M. Benlloch-Rodríguez,
J. V. Carrión,
D. Cubero,
J. Díaz,
R. Esteve,
R. Gadea,
J. Gillam,
J. Generowicz,
J. L. López-Gómez,
A. Martínez,
F. Monrabal,
M. Querol,
M. Rappaport,
J. Rodríguez,
J. Rodríguez-Ponce,
P. Solevi,
S. Teruel-Pardo,
J. F. Toledo,
R. Torres-Curado,
V. Herrero-Bosch
, et al. (2 additional authors not shown)
Abstract:
New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight in…
▽ More
New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating medium and UV-sensitive silicon photomultipliers for scintillation readout. The scintillation time in liquid xenon is fast enough to register time-of-flight information for each detected coincidence, and sufficient scintillation is produced with low enough fluctuations to obtain good energy resolution. The present simulation study examines a full-body-sized PETALO detector and evaluates its potential performance in PET image reconstruction.
△ Less
Submitted 11 January, 2023; v1 submitted 27 September, 2021;
originally announced September 2021.