Thermoluminescent characteristics of LiF:Mg,Cu,P and CaSO$_4$:Dy for low dose measurement
Authors:
S. Del Sol Fernández,
R. García-Salcedo,
J. Guzmán Mendoza,
D. Sánchez-Guzmán,
G. Ramírez Rodríguez,
E. Gaona,
T. Rivera Montalvo
Abstract:
Thermoluminescence (TL) characteristics for LiF:Mg,Cu,P, and CaSO$_4$:Dy under the homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescence dosimetry is presented. The irradiation were performed utilizing a conventional X-ray equipment installed at the Hospital Juárez Norte of México. Different thermoluminescence characteristics of two material were…
▽ More
Thermoluminescence (TL) characteristics for LiF:Mg,Cu,P, and CaSO$_4$:Dy under the homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescence dosimetry is presented. The irradiation were performed utilizing a conventional X-ray equipment installed at the Hospital Juárez Norte of México. Different thermoluminescence characteristics of two material were studied, such as batch homogeneity, glow curve, linearity, detection threshold, reproducibility, relative sensitivity and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and they were positioned in a generic phantom. The dose analysis, verification and comparison with the measurements obtained by the TLD-100 were performed. Results indicate that the dosimetric peak appears at 202$^o$C and 277.5$^o$C for LiF:Mg,Cu,P and CaSO$_4$:Dy, respectively. TL response as a function of X-ray dose showed a linearity behavior in the very low dose range for all materials. However, the TLD-100 is not accurate for measurements below $4mGy$. CaSO$_4$:Dy is 80\% more sensitive than TLD-100 and it show the lowest detection threshold, whereas LiF:Mg,Cu,P is 60\% more sensitive than TLD-100. All material showed very good repeatability. Fading for a period of one month at room temperature showed low fading LiF:Mg,Cu,P, medium and high for TLD-100 and CaSO$_4$:Dy. The results suggest that CaSO$_4$:Dy and LiF:Mg,Cu,P are suitable for measurements at low doses used in radiodiagnostic.
△ Less
Submitted 31 March, 2016;
originally announced April 2016.
New solar axion search in CAST with $^4$He filling
Authors:
M. Arik,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
J. Bremer,
V. Burwitz,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
J. I. Collar,
E. Da Riva,
T. Dafni,
M. Davenport,
A. Dermenev,
C. Eleftheriadis,
N. Elias,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (38 additional authors not shown)
Abstract:
The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we use…
▽ More
The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we used $^4$He in 2005--2007 to cover the mass range of 0.02--0.39 eV and $^3$He in 2009--2011 to scan from 0.39--1.17 eV. After improving the detectors and shielding, we returned to $^4$He in 2012 to investigate a narrow $m_a$ range around 0.2 eV ("candidate setting" of our earlier search) and 0.39--0.42 eV, the upper axion mass range reachable with $^4$He, to "cross the axion line" for the KSVZ model. We have improved the limit on the axion-photon coupling to $g_{aγ}< 1.47\times10^{-10} {\rm
GeV}^{-1}$ (95% C.L.), depending on the pressure settings. Since 2013, we have returned to vacuum and aim for a significant increase in sensitivity.
△ Less
Submitted 11 June, 2015; v1 submitted 2 March, 2015;
originally announced March 2015.