-
Fibonacci Waveguide Quantum Electrodynamics
Authors:
Florian Bönsel,
Flore K. Kunst,
Federico Roccati
Abstract:
Waveguide quantum electrodynamics (QED) provides a powerful framework for engineering quantum interactions, traditionally relying on periodic photonic arrays with continuous energy bands. Here, we investigate waveguide QED in a fundamentally different environment: A one-dimensional photonic array whose hopping strengths are structured aperiodically according to the deterministic Fibonacci-Lucas su…
▽ More
Waveguide quantum electrodynamics (QED) provides a powerful framework for engineering quantum interactions, traditionally relying on periodic photonic arrays with continuous energy bands. Here, we investigate waveguide QED in a fundamentally different environment: A one-dimensional photonic array whose hopping strengths are structured aperiodically according to the deterministic Fibonacci-Lucas substitution rule. These "Fibonacci waveguides" lack translational invariance and are characterized by a singular continuous energy spectrum and critical eigenstates, representing a deterministic intermediate between ordered and disordered systems. We demonstrate how to achieve decoherence-free, coherent interactions in this unique setting. We analyze two paradigmatic cases: (i) Giant emitters resonantly coupled to the simplest aperiodic version of a standard waveguide. For these, we show that atom photon bound states form only for specific coupling configurations dictated by the aperiodic sequence, leading to an effective atomic Hamiltonian, which itself inherits the Fibonacci structure; and (ii) emitters locally and off-resonantly coupled to the aperiodic version of the Su-Schrieffer-Heeger waveguide. In this case the mediating bound states feature aperiodically modulated profiles, resulting in an effective Hamiltonian with multifractal properties. Our work establishes Fibonacci waveguides as a versatile platform, which is experimentally feasible, demonstrating that the deterministic complexity of aperiodic structures can be directly engineered into the interactions between quantum emitters.
△ Less
Submitted 8 July, 2025;
originally announced July 2025.
-
Controlling Markovianity with Chiral Giant Atoms
Authors:
Federico Roccati,
Dario Cilluffo
Abstract:
Giant artificial atoms are promising and flexible building blocks for the implementation of analog quantum simulators. They are realized via a multi-local pattern of couplings of two-level systems to a waveguide, or to a two-dimensional photonic bath. A hallmark of giant-atom physics is their non-Markovian character in the form of self-coherent feedback, leading, e.g., to non-exponential atomic de…
▽ More
Giant artificial atoms are promising and flexible building blocks for the implementation of analog quantum simulators. They are realized via a multi-local pattern of couplings of two-level systems to a waveguide, or to a two-dimensional photonic bath. A hallmark of giant-atom physics is their non-Markovian character in the form of self-coherent feedback, leading, e.g., to non-exponential atomic decay. The timescale of their non-Markovianity is essentially given by the time delay proportional to the distance between the various coupling points. In parallel, with the state-of-the-art experimental setups, it is possible to engineer complex phases in the atom-light couplings. Such phases simulate an artificial magnetic field, yielding a chiral behavior of the atom-light system. Here, we report a surprising connection between these two seemingly unrelated features of giant atoms, showing that the chirality of a giant atom controls its Markovianity. In particular, by adjusting the couplings' phases, a giant atom can, counterintuitively, enter an exact Markovian regime irrespectively of any inherent time delay. We illustrate this mechanism as an interference process and via a collision model picture. Our findings significantly advance the understanding of giant atom physics, and open new avenues for the control of quantum nanophotonic networks.
△ Less
Submitted 9 August, 2024; v1 submitted 23 February, 2024;
originally announced February 2024.
-
Hermitian and Non-Hermitian Topology from Photon-Mediated Interactions
Authors:
Federico Roccati,
Miguel Bello,
Zongping Gong,
Masahito Ueda,
Francesco Ciccarello,
Aurélia Chenu,
Angelo Carollo
Abstract:
Light can mediate effective dipole-dipole interactions between atoms or quantum emitters coupled to a common environment. Exploiting them to tailor a desired effective Hamiltonian can have major applications and advance the search for many-body phases. Quantum technologies are mature enough to engineer large photonic lattices with sophisticated structures coupled to quantum emitters. In this conte…
▽ More
Light can mediate effective dipole-dipole interactions between atoms or quantum emitters coupled to a common environment. Exploiting them to tailor a desired effective Hamiltonian can have major applications and advance the search for many-body phases. Quantum technologies are mature enough to engineer large photonic lattices with sophisticated structures coupled to quantum emitters. In this context, a fundamental problem is to find general criteria to tailor a photonic environment that mediates a desired effective Hamiltonian of the atoms. Among these criteria, topological properties are of utmost importance since an effective atomic Hamiltonian endowed with a non-trivial topology can be protected against disorder and imperfections. Here, we find general theorems that govern the topological properties (if any) of photon-mediated Hamiltonians in terms of both Hermitian and non-Hermitian topological invariants, thus unveiling a system-bath topological correspondence. The results depend on the number of emitters relative to the number of resonators. For a photonic lattice where each mode is coupled to a single quantum emitter, the Altland-Zirnbauer classification of topological insulators allows us to link the topology of the atoms to that of the photonic bath: we unveil the phenomena of topological preservation and reversal to the effect that the atomic topology can be the same or opposite to the photonic one, depending on Hermiticity of the photonic system and on the parity of the spatial dimension. As a consequence, the bulk-edge correspondence implies the existence of atomic boundary modes with the group velocity opposite to the photonic ones in a 2D Hermitian topological system. If there are fewer emitters than photonic modes, the atomic system is less constrained and no general photon-atom topological correspondence can be found. We show this with two counterexamples.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards
, et al. (102 additional authors not shown)
Abstract:
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstr…
▽ More
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
△ Less
Submitted 18 March, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
The KATRIN Superconducting Magnets: Overview and First Performance Results
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (99 additional authors not shown)
Abstract:
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet sy…
▽ More
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064~m to 9~m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70$\%$ of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01$\%$ per month at 70$\%$ of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.
△ Less
Submitted 22 June, 2018; v1 submitted 21 June, 2018;
originally announced June 2018.
-
Muon-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel
, et al. (109 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of part…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of particular concern. Coincidence measurements with the MS and a scintillator-based muon detector system confirmed the model of secondary electron production by cosmic-ray muons inside the MS. Correlation measurements with the same setup showed that about $12\%$ of secondary electrons emitted from the inner surface are induced by cosmic-ray muons, with approximately one secondary electron produced for every 17 muon crossings. However, the magnetic and electrostatic shielding of the MS is able to efficiently suppress these electrons, and we find that muons are responsible for less than $17\%$ ($90\%$ confidence level) of the overall MS background.
△ Less
Submitted 13 December, 2018; v1 submitted 30 May, 2018;
originally announced May 2018.
-
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
Authors:
KATRIN Collaboration,
M. Arenz,
W. -J. Baek,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
R. Berendes,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
W. Buglak,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (105 additional authors not shown)
Abstract:
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such…
▽ More
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
△ Less
Submitted 3 May, 2018;
originally announced May 2018.
-
Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (102 additional authors not shown)
Abstract:
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage divid…
▽ More
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
△ Less
Submitted 15 May, 2018; v1 submitted 14 February, 2018;
originally announced February 2018.
-
First transmission of electrons and ions through the KATRIN beamline
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (104 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons fr…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.
△ Less
Submitted 7 July, 2018; v1 submitted 12 February, 2018;
originally announced February 2018.