-
Sub-keV Electron Recoil Calibration for Cryogenic Detectors using a Novel X-ray Fluorescence Source
Authors:
H. Abele,
G. Angloher,
B. Arnold,
M. Atzori Corona,
A. Bento,
E. Bossio,
J. Burkhart,
F. Cappella,
M. Cappelli,
N. Casali,
R. Cerulli,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
S. Dorer,
A. Erhart,
M. Friedl,
S. Fichtinger,
V. M. Ghete,
M. Giammei,
C. Goupy,
D. Hauff,
F. Jeanneau,
E. Jericha,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Calibration of cryogenic detectors with energy thresholds below 100 eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting monoene…
▽ More
Calibration of cryogenic detectors with energy thresholds below 100 eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting monoenergetic X-rays from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in detectors based on transition edge sensors (TES).
△ Less
Submitted 23 May, 2025;
originally announced May 2025.
-
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
Authors:
H. Abele,
P. Ajello,
A. Armatol,
B. Arnold,
J. Billard,
E. Bossio,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
J. Colas,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
S. Dorer,
C. Doutre,
A. Erhart,
S. Fichtinger,
M. Friedl,
P. Garin,
R. Gergen,
C. Goupy,
D. Hainz,
D. Hauff,
E. Jericha
, et al. (29 additional authors not shown)
Abstract:
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined…
▽ More
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. A crown of BaF$_2$ detectors installed outside the dewar enables coincident detection of the high-energy $γ$ escaping the target crystal after neutron capture. After the presentation of all components of the setup we report the analysis of first commissioning data with a CaWO$_4$ detector of the \NUCLEUS experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $^{187}$W. Finally, we present the first evidence of neutron-capture induced coincidences between $γ$-detectors and a cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO$_4$, Al$_2$O$_3$, Ge and Si.
△ Less
Submitted 21 May, 2025;
originally announced May 2025.
-
Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures
Authors:
The NUCLEUS collaboration,
A. Wex,
J. Rothe,
L. Peters,
H. Abele,
G. Angloher,
B. Arnold,
M. Atzori Corona,
A. Bento,
E. Bossio,
J. Burkhart,
L. Canonica,
F. Cappella,
M. Cappelli,
N. Casali,
R. Cerulli,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
A. Erhart,
M. Friedl,
S. Fichtinger,
A. Garai
, et al. (42 additional authors not shown)
Abstract:
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a…
▽ More
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low $(6.22 \pm 0.07)$ eV baseline resolution on a gram-scale CaWO$_4$ cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.
△ Less
Submitted 7 April, 2025; v1 submitted 8 January, 2025;
originally announced January 2025.
-
Germanium target sensed by phonon-mediated kinetic inductance detectors
Authors:
D. Delicato,
D. Angelone,
L. Bandiera,
M. Calvo,
M. Cappelli,
U. Chowdhury,
G. Del Castello,
M. Folcarelli,
M. del Gallo Roccagiovine,
V. Guidi,
G. L. Pesce,
M. Romagnoni,
A. Cruciani,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
Cryogenic phonon detectors are adopted in experiments searching for dark matter interactions or coherent elastic neutrino-nucleus scattering, thanks to the low energy threshold they can achieve. The phonon-mediated sensing of particle interactions in passive silicon absorbers has been demonstrated with Kinetic Inductance Detectors (KIDs). Targets with neutron number larger than silicon, however, f…
▽ More
Cryogenic phonon detectors are adopted in experiments searching for dark matter interactions or coherent elastic neutrino-nucleus scattering, thanks to the low energy threshold they can achieve. The phonon-mediated sensing of particle interactions in passive silicon absorbers has been demonstrated with Kinetic Inductance Detectors (KIDs). Targets with neutron number larger than silicon, however, feature higher cross section to neutrinos while multi-target absorbers in dark matter experiments would provide a stronger evidence of a possible signal. In this work we present the design, fabrication and operation of KIDs coupled to a germanium absorber, achieving phonon-sensing performance comparable to silicon absorbers. The device introduced in this work is a proof of concept for a scalable neutrino detector and for a multi-target dark matter experiment.
△ Less
Submitted 15 April, 2025; v1 submitted 10 December, 2024;
originally announced December 2024.
-
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
Authors:
A. Erhart,
V. Wagner,
A. Wex,
C. Goupy,
D. Lhuillier,
E. Namuth,
C. Nones,
R. Rogly,
V. Savu,
M. Schwarz,
R. Strauss,
M. Vivier,
H. Abele,
G. Angloher,
A. Bento,
J. Burkhart,
L. Canonica,
F. Cappella,
N. Casali,
R. Cerulli,
A. Cruciani,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer
, et al. (37 additional authors not shown)
Abstract:
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we…
▽ More
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Low-energy spectrum of the BULLKID detector array operated on surface
Authors:
D. Delicato,
A. Ahmad,
L. Bandiera,
M. Calvo,
M. Cappelli,
G. Del Castello,
M. del Gallo Roccagiovine,
M. Giammei,
V. Guidi,
D. Maiello,
V. Pettinacci,
M. Romagnoni,
M. Tamisari,
A. Cruciani,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
We present the first continuous operation in a surface lab of BULLKID, a detector for searches of light Dark Matter and precision measurements of the coherent and elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The data presented focusses on one of the central elements of…
▽ More
We present the first continuous operation in a surface lab of BULLKID, a detector for searches of light Dark Matter and precision measurements of the coherent and elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The data presented focusses on one of the central elements of the array and on its surrounding elements used as veto. The energy spectrum resulting from an exposure of 39 hours to ambient backgrounds, obtained without radiation shields, is flat at the level of $(2.0\pm0.1\,{\rm stat.}\pm0.2\,{\rm syst.})\times10^6$ counts / keV kg days down to the energy threshold of $160\pm13$ eV. The data analysis demonstrates the unique capability of rejecting backgrounds generated from interactions in other sites of the array, stemming from the segmented and monolithic structure of the detector.
△ Less
Submitted 17 April, 2024; v1 submitted 28 August, 2023;
originally announced August 2023.
-
Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors
Authors:
CRAB collaboration,
G. Soum-Sidikov,
H. Abele,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
E. Dumonteil,
A. Erhart,
A. Giuliani,
C. Goupy,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
H. Kluck,
A. Langenkämper,
T. Lasserre
, et al. (25 additional authors not shown)
Abstract:
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay betwe…
▽ More
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment
Authors:
The NUCLEUS collaboration,
C. Goupy,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
I. Colantoni,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
A. Erhart,
M. Friendl,
A. Garai,
V. M. Ghete,
D. Hauff,
F. Jeanneau,
E. Jericha,
M. Kaznacheeva,
A. Kinast
, et al. (37 additional authors not shown)
Abstract:
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for…
▽ More
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for high-sensitivity Dark-Matter searches. NUCLEUS is an experiment under construction based on ultra-low threshold (20 eVnr) cryogenic calorimeters, operated at tens-of-mK temperatures.
△ Less
Submitted 10 November, 2022; v1 submitted 8 November, 2022;
originally announced November 2022.
-
Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture
Authors:
CRAB Collaboration,
NUCLEUS Collaboration,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
I. Colantoni,
J. -P. Crocombette,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Desforge,
A. Doblhammer,
E. Dumonteil,
S. Dorer,
A. Erhart,
A. Fuss,
M. Friedl,
A. Garai
, et al. (53 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact…
▽ More
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.
△ Less
Submitted 2 June, 2023; v1 submitted 7 November, 2022;
originally announced November 2022.
-
BULLKID: Monolithic array of particle absorbers sensed by Kinetic Inductance Detectors
Authors:
A. Cruciani,
L. Bandiera,
M. Calvo,
N. Casali,
I. Colantoni,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Delicato,
M. Giammei,
V. Guidi,
J. Goupy,
V. Pettinacci,
G. Pettinari,
M. Romagnoni,
M. Tamisari,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prot…
▽ More
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prototype presented consists of an array of 64 dices of 5.4x5.4x5 mm$^3$ carved in a 3" diameter, 5 mm thick silicon wafer, with a common disk 0.5 mm thick hosting a 60 nm patterned aluminum layer. The resulting array is highly segmented but avoids the use of dedicated holding structures for each unit. Despite the fact that the uniformity of the KID electrical response across the array needs optimization, the operation of 8 units with similar features shows, on average, a baseline energy resolution of $26\pm7$ eV. This makes it a suitable detector for low-energy processes such as direct interactions of dark matter and coherent elastic neutrino-nucleus scattering.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.