Generalized Signal Models and Direct FID-Based Dielectric Parameter Retrieval in MRI
Authors:
Patrick Fuchs,
Rob Remis
Abstract:
In this paper we present full-wave signal models for magnetic and electric field measurements in magnetic resonance imaging (MRI). Our analysis is based on a scattering formalism in which the presence of an object or body is taken into account via an electric scattering source. We show that these signal models can be evaluated, provided the Green's tensors of the background field are known along w…
▽ More
In this paper we present full-wave signal models for magnetic and electric field measurements in magnetic resonance imaging (MRI). Our analysis is based on a scattering formalism in which the presence of an object or body is taken into account via an electric scattering source. We show that these signal models can be evaluated, provided the Green's tensors of the background field are known along with the dielectric parameters of the object and the magnetization within the excited part of the object. Furthermore, explicit signal expressions are derived in case of a small homogeneous ball that is embedded in free space and for which the quasi-static Born approximation can be applied. The conductivity and permittivity of the ball appear as explicit parameters in the resulting signal models and allow us to study the sensitivity of the measured signals with respect to these dielectric parameters. Moreover, for free induction decay signals we show that under certain conditions it is possible to retrieve the dielectric parameters of the ball from noise-contaminated induction decay signals that are based on electric or magnetic field measurements.
△ Less
Submitted 30 November, 2020;
originally announced November 2020.
-
Gradient Coil Design and Realization for a Halbach-Based MRI System
Authors:
Bart de Vos,
Patrick Fuchs,
Thomas O'Reilly,
Andrew Webb,
Rob Remis
Abstract:
In this paper we design and construct gradient coils for a Halbach permanent magnet array magnetic resonance (MR) scanner. The target field method, which is widely applied for the case of axial static magnetic fields, has been developed for a transverse static magnetic field as produced by a Halbach permanent magnet array. Using this method, current densities for three gradient directions are obta…
▽ More
In this paper we design and construct gradient coils for a Halbach permanent magnet array magnetic resonance (MR) scanner. The target field method, which is widely applied for the case of axial static magnetic fields, has been developed for a transverse static magnetic field as produced by a Halbach permanent magnet array. Using this method, current densities for three gradient directions are obtained and subsequently verified using a commercial magneto-static solver. Stream functions are used to turn the surface current densities into wire patterns for constructing the gradient coils. The measured fields are in good agreement with simulations and their prescribed target fields. Three dimensional images have been acquired using the constructed gradient coils with very low degree of geometric distortion.
△ Less
Submitted 18 December, 2019;
originally announced December 2019.
-
Modal Analysis of photonic and plasmonic resonators
Authors:
Jörn Zimmerling,
Rob Remis
Abstract:
Quasi-normal modes (QNMs) are ubiquitous throughout photonics and are utilized in a wide variety of applications, but determining these modes remains a formidable task in general. Here we show that by exploiting the structure of Maxwell's equations it is possible to effectively compute QNMs of photonic and plasmonic nanoresonators. The symmetry of Maxwell's equations allows for a reduction to a sy…
▽ More
Quasi-normal modes (QNMs) are ubiquitous throughout photonics and are utilized in a wide variety of applications, but determining these modes remains a formidable task in general. Here we show that by exploiting the structure of Maxwell's equations it is possible to effectively compute QNMs of photonic and plasmonic nanoresonators. The symmetry of Maxwell's equations allows for a reduction to a system of small order via a Lanczos reduction process through which dominant QNMs can be identified. A closed-form reduced-order model for the spontaneous decay (SD) rate of a quantum emitter is also obtained, which does not require an a priori QNM expansion of the fields. The model is parametric in wavelength and field expansions in dominant QNMs are determined a posteriori. We demonstrate and validate that QNMs of open resonators and the SD rate of a quantum emitter are accurately predicted.
△ Less
Submitted 28 October, 2019;
originally announced October 2019.
-
Combining Deep Learning and 3D Contrast Source Inversion in MR-based Electrical Properties Tomography
Authors:
Reijer L. Leijsen,
Cornelis A. T. van den Berg,
Andrew G. Webb,
Rob F. Remis,
Stefano Mandija
Abstract:
Magnetic resonance-electrical properties tomography (MR-EPT) is a technique used to estimate the conductivity and permittivity of tissues from MR measurements of the transmit magnetic field. Different reconstruction methods are available, however all these methods present several limitations which hamper the clinical applicability. Standard Helmholtz based MR-EPT methods are severely affected by n…
▽ More
Magnetic resonance-electrical properties tomography (MR-EPT) is a technique used to estimate the conductivity and permittivity of tissues from MR measurements of the transmit magnetic field. Different reconstruction methods are available, however all these methods present several limitations which hamper the clinical applicability. Standard Helmholtz based MR-EPT methods are severely affected by noise. Iterative reconstruction methods such as contrast source inversion-EPT (CSI-EPT) are typically time consuming and are dependent on their initialization. Deep learning (DL) based methods require a large amount of training data before sufficient generalization can be achieved. Here, we investigate the benefits achievable using a hybrid approach, i.e. using MR-EPT or DL-EPT as initialization guesses for standard 3D CSI-EPT. Using realistic electromagnetic simulations at 3 T and 7 T, the accuracy and precision of hybrid CSI reconstructions are compared to standard 3D CSI-EPT reconstructions. Our results indicate that a hybrid method consisting of an initial DL-EPT reconstruction followed by a 3D CSI-EPT reconstruction would be beneficial. DL-EPT combined with standard 3D CSI-EPT exploits the power of data driven DL-based EPT reconstructions while the subsequent CSI-EPT facilitates a better generalization by providing data consistency.
△ Less
Submitted 13 August, 2019;
originally announced August 2019.
-
Transceive Phase Corrected Contrast Source Inversion-Electrical Properties Tomography
Authors:
Peter R. S. Stijnman,
Stefano Mandija,
Patrick S. Fuchs,
Cornelis A. T. van den Berg,
Rob F. Remis
Abstract:
Magnetic resonance imaging (MRI) based electrical properties tomography (EPT) is the quantification of the conductivity and permittivity of different tissues. These electrical properties can be obtained through different reconstruction methods and can be used as a contrast mechanism. The work presented here continues from the two-dimensional CSI-EPT algorithm which was shown to work with two-dimen…
▽ More
Magnetic resonance imaging (MRI) based electrical properties tomography (EPT) is the quantification of the conductivity and permittivity of different tissues. These electrical properties can be obtained through different reconstruction methods and can be used as a contrast mechanism. The work presented here continues from the two-dimensional CSI-EPT algorithm which was shown to work with two-dimensional Matlab based simulations. The existing CSI-EPT algorithm is reformulated to use the transceive phase rather than relying on the transceive phase assumption. This is achieved by implementing a forward problem, computing the receive phase, into the inverse minimization problem, i.e. retrieving the electrical properties. Furthermore, the radio frequency (RF) shield is numerically implemented to model the RF fields inside the MRI more accurately. Afterwards, the algorithm is tested with three-dimensional FDTD simulations to investigate if the two-dimensional CSI-EPT can retrieve the electrical properties for three-dimensional RF fields. Finally, an MR experiment with a phantom is performed to show the potential for this method. From the results of the two-dimensional Matlab simulations it is seen that CSI-EPT can reconstruct the electrical properties using MRI accessible quantities. In the three-dimensional simulations it is observed that the electrical properties are underestimated, nonetheless, CSI-EPT is more precise than the standard Helmholtz based methods. Finally, the first CSI-EPT results using measured data are shown. The results for the reconstruction using measured data were of the same quality as the results from the FDTD simulation.
△ Less
Submitted 31 July, 2019;
originally announced July 2019.
-
Quasinormal mode solvers for resonators with dispersive materials
Authors:
P. Lalanne,
W. Yan,
A. Gras,
C. Sauvan,
J. -P. Hugonin,
M. Besbes,
G. Demesy,
M. D. Truong,
B. Gralak,
F. Zolla,
A. Nicolet,
F. Binkowski,
L. Zschiedrich,
S. Burger,
J. Zimmerling,
R. Remis,
P. Urbach,
H. T. Liu,
T. Weiss
Abstract:
Optical resonators are widely used in modern photonics. Their spectral response and temporal dynamics are fundamentally driven by their natural resonances, the so-called quasinormal modes (QNMs), with complex frequencies. For optical resonators made of dispersive materials, the QNM computation requires solving a nonlinear eigenvalue problem. This rises a difficulty that is only scarcely documented…
▽ More
Optical resonators are widely used in modern photonics. Their spectral response and temporal dynamics are fundamentally driven by their natural resonances, the so-called quasinormal modes (QNMs), with complex frequencies. For optical resonators made of dispersive materials, the QNM computation requires solving a nonlinear eigenvalue problem. This rises a difficulty that is only scarcely documented in the literature. We review our recent efforts for implementing efficient and accurate QNM-solvers for computing and normalizing the QNMs of micro- and nano-resonators made of highly-dispersive materials. We benchmark several methods for three geometries, a two-dimensional plasmonic crystal, a two-dimensional metal grating, and a three-dimensional nanopatch antenna on a metal substrate, in the perspective to elaborate standards for the computation of resonance modes.
△ Less
Submitted 28 November, 2018;
originally announced November 2018.
-
High-Permittivity Pad Design Tool for 7T Neuroimaging and 3T Body Imaging
Authors:
J. H. F. van Gemert,
W. M. Brink,
A. G. Webb,
R. F. Remis
Abstract:
Purpose: High-permittivity materials in the form of flexible 'dielectric pads' have proved very useful for addressing RF inhomogeneities in high field MRI. Finding the optimal design of such pads is however a tedious task, reducing the impact of this technique. In this work we present an easy to use software tool which allows researchers and clinicians to design dielectric pads efficiently on stan…
▽ More
Purpose: High-permittivity materials in the form of flexible 'dielectric pads' have proved very useful for addressing RF inhomogeneities in high field MRI. Finding the optimal design of such pads is however a tedious task, reducing the impact of this technique. In this work we present an easy to use software tool which allows researchers and clinicians to design dielectric pads efficiently on standard computer systems, for 7T neuroimaging and 3T body imaging applications. Methods: The tool incorporates advanced computational methods based on field decomposition and model order reduction as a framework to efficiently evaluate the B1+ fields resulting from dielectric pads. The tool further incorporates an optimization routine to perform either straightforward design for one or two pads based on a target field approach, or a trade-off analysis between homogeneity and efficiency of the B1+ field in a specific region of interest. The 3T version further allows for shifting of the imaging landmark to enable different imaging targets to be centered in the body coil.Results: Example design results are shown for imaging the inner ear at 7T and for cardiac imaging at 3T. Computation times for all cases were under a couple of minutes. The change in homogeneity and efficiency with the pad's dimensions, location, and constitution are clearly listed. Conclusion: The developed tool can be easily used to design pads for any 7T neuroimaging and 3T body imaging application within minutes. This bridges the gap between the advanced design methods and the practical application by the MR community.
△ Less
Submitted 30 July, 2018;
originally announced July 2018.