-
Neutron-induced background in the CONUS experiment
Authors:
J. Hakenmüller,
C. Buck,
K. Fülber,
G. Heusser,
T. Klages,
M. Lindner,
A. Lücke,
W. Maneschg,
M. Reginatto,
T. Rink,
T. Schierhuber,
D. Solasse,
H. Strecker,
R. Wink,
M. Zboril,
A. Zimbal
Abstract:
CONUS is a novel experiment aiming at detecting elastic neutrino nucleus scattering in the fully coherent regime using high-purity Germanium (Ge) detectors and a reactor as antineutrino ($\barν$) source. The detector setup is installed at the commercial nuclear power plant in Brokdorf, Germany, at a very small distance to the reactor core in order to guarantee a high flux of more than 10…
▽ More
CONUS is a novel experiment aiming at detecting elastic neutrino nucleus scattering in the fully coherent regime using high-purity Germanium (Ge) detectors and a reactor as antineutrino ($\barν$) source. The detector setup is installed at the commercial nuclear power plant in Brokdorf, Germany, at a very small distance to the reactor core in order to guarantee a high flux of more than 10$^{13}\barν$/(s$\cdot$cm$^2$). For the experiment, a good understanding of neutron-induced background events is required, as the neutron recoil signals can mimic the predicted neutrino interactions. Especially neutron-induced events correlated with the thermal power generation are troublesome for CONUS. On-site measurements revealed the presence of a thermal power correlated, highly thermalized neutron field with a fluence rate of (745$\pm$30)cm$^{-2}$d$^{-1}$. These neutrons that are produced by nuclear fission inside the reactor core, are reduced by a factor of $\sim$10$^{20}$ on their way to the CONUS shield. With a high-purity Ge detector without shield the $γ$-ray background was examined including highly thermal power correlated $^{16}$N decay products as well as $γ$-lines from neutron capture. Using the measured neutron spectrum as input, it was shown, with the help of Monte Carlo simulations, that the thermal power correlated field is successfully mitigated by the installed CONUS shield. The reactor-induced background contribution in the region of interest is exceeded by the expected signal by at least one order of magnitude assuming a realistic ionization quenching factor of 0.2.
△ Less
Submitted 31 December, 2019; v1 submitted 21 March, 2019;
originally announced March 2019.
-
Another look through Heisenberg's microscope
Authors:
Stephen Boughn,
Marcel Reginatto
Abstract:
Heisenberg introduced his famous uncertainty relations in a seminal 1927 paper entitled "The Physical Content of Quantum Kinematics and Mechanics". He motivated his arguments with a gedanken experiment, a gamma ray microscope to measure the position of a particle. A primary result was that, due to the quantum nature of light, there is an inherent uncertainty in the determinations of the particle's…
▽ More
Heisenberg introduced his famous uncertainty relations in a seminal 1927 paper entitled "The Physical Content of Quantum Kinematics and Mechanics". He motivated his arguments with a gedanken experiment, a gamma ray microscope to measure the position of a particle. A primary result was that, due to the quantum nature of light, there is an inherent uncertainty in the determinations of the particle's position and momentum dictated by an indeterminacy relation, $δq δp \sim h$. Heisenberg offered this demonstration as "a direct physical interpretation of the [quantum mechanical] equation $\textbf{pq} - \textbf{qp} = -i\hbar$" but considered the indeterminacy relation to be much more than this. He also argued that it implies limitations on the very meanings of position and momentum and emphasized that these limitations are the source of the statistical character of quantum mechanics. In addition, Heisenberg hoped but was unable to demonstrate that the laws of quantum mechanics could be derived directly from the uncertainty relation. In this paper, we revisit Heisenberg's microscope and argue that the Schrödinger equation for a free particle does indeed follow from the indeterminacy relation together with reasonable statistical assumptions.
△ Less
Submitted 22 December, 2017;
originally announced December 2017.
-
A Pedestrian Approach to the Measurement Problem in Quantum Mechanics
Authors:
Stephen Boughn,
Marcel Reginatto
Abstract:
The quantum theory of measurement has been a matter of debate for over eighty years. Most of the discussion has focused on theoretical issues with the consequence that operational prescriptions, which are integral to experimental physics, have been largely ignored. This has undoubtedly exacerbated attempts to find a solution to the "measurement problem". In this paper, we fully embrace the ensembl…
▽ More
The quantum theory of measurement has been a matter of debate for over eighty years. Most of the discussion has focused on theoretical issues with the consequence that operational prescriptions, which are integral to experimental physics, have been largely ignored. This has undoubtedly exacerbated attempts to find a solution to the "measurement problem". In this paper, we fully embrace the ensemble interpretation of quantum mechanics that obviates the need to entertain reduction of the state vector, one of the primary dilemmas of the measurement problem. The other major aspect of the measurement problem, the necessity of describing measurements in terms of classical concepts, remains. However, we argue that the ultimate interface with experiments is described by operational prescriptions and not in terms of the concepts of classical theory. The pedestrian approach presented here suggests that the measurement problem is, in some sense, ill-posed and might never be resolved. This state of affairs is, in part, the result of searching for a theoretical answer to what is fundamentally an experimental question. This point of view is tenable so long as one is willing to view physical theories as providing models of nature rather than complete descriptions of reality. Among other things, these considerations lead us to suggest that the Copenhagen interpretation's insistence on the classicality of the measurement apparatus should be replaced by the requirement that a measurement, which is specified operationally, should simply be of sufficient precision.
△ Less
Submitted 3 September, 2013;
originally announced September 2013.
-
Results for the response function determination of the Compact Neutron Spectrometer
Authors:
F. Gagnon-Moisan,
M. Reginatto,
A. Zimbal
Abstract:
The Compact Neutron Spectrometer (CNS) is a Joint European Torus (JET) Enhancement Project, designed for fusion diagnostics in different plasma scenarios. The CNS is based on a liquid scintillator (BC501A) which allows good discrimination between neutron and gamma radiation. Neutron spectrometry with a BC501A spectrometer requires the use of a reliable, fully characterized detector. The determinat…
▽ More
The Compact Neutron Spectrometer (CNS) is a Joint European Torus (JET) Enhancement Project, designed for fusion diagnostics in different plasma scenarios. The CNS is based on a liquid scintillator (BC501A) which allows good discrimination between neutron and gamma radiation. Neutron spectrometry with a BC501A spectrometer requires the use of a reliable, fully characterized detector. The determination of the response matrix was carried out at the Ion Accelerator Facility (PIAF) of the Physikalisch-Technische Bundesanstalt (PTB). This facility provides several monoenergetic beams (2.5, 8, 10, 12 and 14 MeV) and a 'white field'(Emax ~17 MeV), which allows for a full characterization of the spectrometer in the region of interest (from ~1.5 MeV to ~17 MeV. The energy of the incoming neutrons was determined by the time of flight method (TOF), with time resolution in the order of 1 ns. To check the response matrix, the measured pulse height spectra were unfolded with the code MAXED and the resulting energy distributions were compared with those obtained from TOF. The CNS project required modification of the PTB BC501A spectrometer design, to replace an analog data acquisition system (NIM modules) with a digital system developed by the 'Ente per le Nuove tecnologie, l'Energia e l'Ambiente' (ENEA). Results for the new digital system were evaluated using new software developed specifically for this project.
△ Less
Submitted 30 January, 2012;
originally announced January 2012.
-
Detectors for Time-of-Flight Fast-Neutron Radiography: 1. Neutron Counting Gas Detector
Authors:
V. Dangendorf,
A. Breskin,
R. Chechik,
M. Goldberg,
G. Laczko,
I. Mor,
M. Reginatto,
D. Vartsky
Abstract:
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived f…
▽ More
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived from a experiment in a pulsed neutron beam of spectral distribution between 2 and 10 MeV
△ Less
Submitted 17 August, 2004;
originally announced August 2004.