Source of pure proton beams
Authors:
S. V. Golubev,
I. V. Izotov,
V. A. Skalyga,
S. S. Vybin,
E. M. Kiseleva,
R. L. Lapin,
S. V. Razin,
A. F. Bokhanov,
M. Yu. Kazakov,
S. P. Shlepnev
Abstract:
In the quasi-gasdynamic high-current ion source described in this work, the plasma is sustained by high-power millimeter-wave radiation under the electron cyclotron resonance (ECR) condition. In such facilities, it is possible to achieve high volumetric energy input of up to $250$ $W/cm^3$ and obtain pure proton beams with a minimum amount of impurities and molecular ions. Experiments conducted on…
▽ More
In the quasi-gasdynamic high-current ion source described in this work, the plasma is sustained by high-power millimeter-wave radiation under the electron cyclotron resonance (ECR) condition. In such facilities, it is possible to achieve high volumetric energy input of up to $250$ $W/cm^3$ and obtain pure proton beams with a minimum amount of impurities and molecular ions. Experiments conducted on the GISMO facility demonstrated the possibility of a proton beam formation with a current of $50$ mA and an extremely high ($99.9$\%) content of atomic ions.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
High Power Vacuum Ultraviolet Source Based on Gasdynamic ECR Plasma
Authors:
R. L. Lapin,
V. A. Skalyga,
S. V. Golubev,
I. V. Izotov,
S. V. Razin
Abstract:
We report experimental results of vacuum ultraviolet (VUV) emission from the plasma of an electron cyclotron resonance (ECR) discharge in hydrogen, sustained by powerful millimeter-wavelength radiation of a gyrotron. Distinctive features of the considered discharge are the high plasma density ($10^{13}$ cm$^{-3}$ order of magnitude) and, at the same time, the high electron average energy (…
▽ More
We report experimental results of vacuum ultraviolet (VUV) emission from the plasma of an electron cyclotron resonance (ECR) discharge in hydrogen, sustained by powerful millimeter-wavelength radiation of a gyrotron. Distinctive features of the considered discharge are the high plasma density ($10^{13}$ cm$^{-3}$ order of magnitude) and, at the same time, the high electron average energy ($10 - 300$ eV), which makes it possible to significantly increase the efficiency of VUV re-emission of the energy deposited into the plasma by the microwave radiation. Experiments were performed with the plasma confined in a simple mirror trap and heated by pulsed gyrotron radiation $37.5$ GHz / $100$ kW under the ECR condition. The measured volumetric VUV emission power of Lyman-alpha line ($122 \pm 10$ nm) overlapping with the Werner band, Lyman band ($160 \pm 10$ nm), and molecular continuum ($180 \pm 20$ nm) reached $45$, $25$, and $55$ W/cm$^3$, respectively. The total absolute radiation power in these three ranges integrated over the plasma volume is estimated to be $22$ kW i.e. $22$% of the incident microwave power, which matches theoretical predictions. Further optimization of the conditions of the ECR hydrogen discharge sustained by powerful gyrotron radiation provides an opportunity for the development of effective technological VUV sources of a kilowatt power level.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
Experiments on intense ion beam formation with inhomogeneous electric field
Authors:
S. S. Vybin,
V. A. Skalyga,
I. V. Izotov,
S. V. Golubev,
S. V. Razin,
R. A. Shaposhnikov,
M. Yu. Kazakov,
A. F. Bokhanov,
S. P. Shlepnev
Abstract:
We report on a successful test of a new method for intense ion beam formation using an extraction with inhomogeneous electric field. Its key feature is a special shape of the extraction electrodes providing a higher rate of ion acceleration. It is applicable to any ion source type and could be used to improve performance of a wide range of plasma devices. The proof of concept was carried out using…
▽ More
We report on a successful test of a new method for intense ion beam formation using an extraction with inhomogeneous electric field. Its key feature is a special shape of the extraction electrodes providing a higher rate of ion acceleration. It is applicable to any ion source type and could be used to improve performance of a wide range of plasma devices. The proof of concept was carried out using a high-current electron-cyclotron resonance ion source SMIS 37. High efficiency of the new extraction and proton beam formation with a record current density of up to 1.1 A cm-2 was demonstrated.
△ Less
Submitted 22 July, 2021;
originally announced July 2021.
-
Status of a point-like neutron generator development
Authors:
S. V. Golubev,
V. A. Skalyga,
I. V. Izotov,
S. V. Razin,
R. A. Shaposhnikov,
S. S. Vybin,
A. F. Bokhanov,
M. Yu. Kazakov,
S. P. Shlepnev,
K. F. Burdonov,
A. A. Soloviev,
M. V. Starodubtsev
Abstract:
In this paper we report on a high current density ion beam profile diagnostics with a slit-based system as a reliable method, capable of high thermal load applications. The task arose in frames of a point-like neutron source development for neutron radiography. In previous research, it was suggested to construct such a system as a D-D neutron generator based on the high current gasdynamic ion sour…
▽ More
In this paper we report on a high current density ion beam profile diagnostics with a slit-based system as a reliable method, capable of high thermal load applications. The task arose in frames of a point-like neutron source development for neutron radiography. In previous research, it was suggested to construct such a system as a D-D neutron generator based on the high current gasdynamic ion source, which utilises the plasma of electron cyclotron resonance discharge sustained by powerful millimeter wave gyrotron radiation. This device is able to produce focused D+ beams with a characteristic diameter of 1 mm, total current above 100 mA, and current density at a level of several A/cm^2. Study of such intense beams profile to obtain the best focusing efficiency and minimize neutron producing area appeared to be a challenging task. The paper also demonstrates the possibility of fast neutron imaging with a point-like powerful neutron generator (neutron yield on the level of 10^10 1/s).
△ Less
Submitted 21 December, 2020; v1 submitted 10 December, 2020;
originally announced December 2020.
-
Study of Gasdynamic Electron Cyclotron Resonance Plasma Vacuum Ultraviolet Emission to Optimize Negative Hydrogen Ion Production Efficiency
Authors:
R. L. Lapin,
V. A. Skalyga,
I. Izotov,
S. V. Razin,
R. A. Shaposhnikov,
S. S. Vybin,
A. F. Bokhanov,
M. Yu. Kazakov,
O. Tarvainen
Abstract:
Negative hydrogen ion sources are used as injectors into accelerators and drive the neutral beam heating in ITER. Certain processes in low-temperature hydrogen plasmas are accompanied by the emission of vacuum ultraviolet (VUV) emission. Studying the VUV radiation therefore provides volumetric rates of plasma-chemical processes and plasma parameters. In the past we have used gasdynamic ECR dischar…
▽ More
Negative hydrogen ion sources are used as injectors into accelerators and drive the neutral beam heating in ITER. Certain processes in low-temperature hydrogen plasmas are accompanied by the emission of vacuum ultraviolet (VUV) emission. Studying the VUV radiation therefore provides volumetric rates of plasma-chemical processes and plasma parameters. In the past we have used gasdynamic ECR discharge for volumetric negative ion production and investigated the dependencies between the extracted H$^-$ current density and various ion source parameters. It was shown that it is possible to reach up to 80 mA/cm$^2$ of negative ion current density with a two electrode extraction. We report experimental studies on negative hydrogen ion production in a high-density gasdynamic ECR discharge plasma consisting of two simple mirror traps together with the results of VUV emission measurements. The VUV-power was measured in three ranges -- Ly$_α$, Lyman band and molecular continuum -- varying the source control parameters near their optima for H$^-$ production. It was shown that the molecular continuum emission VUV power is the highest in the first chamber while Ly$_α$ emission prevails in the second one. Modifications for the experimental scheme for further optimization of negative hydrogen ion production are suggested.
△ Less
Submitted 10 December, 2019;
originally announced December 2019.
-
Observation of extreme-ultraviolet light emission from an expanding plasma jet with multiply-charged argon or xenon ions
Authors:
A. G. Shalashov,
A. V. Vodopyanov,
I. S. Abramov,
A. V. Sidorov,
E. D. Gospodchikov,
S. V. Razin,
N. I. Chkhalo,
N. N. Salashchenko,
M. Yu. Glyavin,
S. V. Golubev
Abstract:
We report the first direct demonstration of possibility to generate the extreme ultraviolet (EUV) radiation with a freely expanding jet of dense plasma with multiply-charged ions supported by high-power microwaves. The detected emission power is about 20 W at 18--50 nm for argon and xenon and 0.3 W at 13--17 nm for xenon. The discharge with a peak electron density up to $3\times 10^{16}\,$cm…
▽ More
We report the first direct demonstration of possibility to generate the extreme ultraviolet (EUV) radiation with a freely expanding jet of dense plasma with multiply-charged ions supported by high-power microwaves. The detected emission power is about 20 W at 18--50 nm for argon and xenon and 0.3 W at 13--17 nm for xenon. The discharge with a peak electron density up to $3\times 10^{16}\,$cm$^{-3}$ and a characteristic size of $150\,μ$m is supported by a focused radiation of a recently developed gyrotron with unique characteristics, 250~kW output power at 250~GHz, operating in a relatively long (50$\,μ$s) pulse mode. Up-scaling of these experimental results gives grounds for development of a point-like kilowatt-level EUV source for a high-resolution lithography able to fulfill requirements of the microelectronics industry.
△ Less
Submitted 19 July, 2018; v1 submitted 18 July, 2018;
originally announced July 2018.