-
Real-time Monitoring of Economic Shocks using Company Websites
Authors:
Michael Koenig,
Jakob Rauch,
Martin Woerter
Abstract:
Understanding the effects of economic shocks on firms is critical for analyzing economic growth and resilience. We introduce a Web-Based Affectedness Indicator (WAI), a general-purpose tool for real-time monitoring of economic disruptions across diverse contexts. By leveraging Large Language Model (LLM) assisted classification and information extraction on texts from over five million company webs…
▽ More
Understanding the effects of economic shocks on firms is critical for analyzing economic growth and resilience. We introduce a Web-Based Affectedness Indicator (WAI), a general-purpose tool for real-time monitoring of economic disruptions across diverse contexts. By leveraging Large Language Model (LLM) assisted classification and information extraction on texts from over five million company websites, WAI quantifies the degree and nature of firms' responses to external shocks. Using the COVID-19 pandemic as a specific application, we show that WAI is highly correlated with pandemic containment measures and reliably predicts firm performance. Unlike traditional data sources, WAI provides timely firm-level information across industries and geographies worldwide that would otherwise be unavailable due to institutional and data availability constraints. This methodology offers significant potential for monitoring and mitigating the impact of technological, political, financial, health or environmental crises, and represents a transformative tool for adaptive policy-making and economic resilience.
△ Less
Submitted 24 February, 2025;
originally announced February 2025.
-
Diffusion pore imaging in the presence of extraporal water
Authors:
Dominik Ludwig,
Frederik Bernd Laun,
Karel D. Klika,
Julian Rauch,
Mark Edward Ladd,
Peter Bachert,
Tristan Anselm Kuder
Abstract:
Diffusion-weighted imaging (DWI) is a powerful non-invasive tool which is widely used in clinical routine. Mostly, apparent diffusion coefficient maps are acquired, which cannot be directly related to cellular structure.
More recently it was shown that DWI is able to reconstruct pore shapes using a specialized magnetic field gradient scheme so that cell size distributions may be obtained. So far…
▽ More
Diffusion-weighted imaging (DWI) is a powerful non-invasive tool which is widely used in clinical routine. Mostly, apparent diffusion coefficient maps are acquired, which cannot be directly related to cellular structure.
More recently it was shown that DWI is able to reconstruct pore shapes using a specialized magnetic field gradient scheme so that cell size distributions may be obtained. So far, artificial systems have been used for experimental demonstration without extraporal signal components and relatively low gradient amplitudes.
Therefore, the aim of this study was to investigate the feasibility of diffusion pore imaging in the presence of extraporal fluids and to develop correction methods for effects arising from extraporal signal contributions. Monte Carlo simulations and validation experiments on a 14.1 T spectrometer with a dedicated diffusion probe head were performed.
Both by using a filter gradient approach suppressing extraporal signal components as well as using postprocessing methods relying on the Gaussian phase approximation, it was possible to reconstruct pore space functions in the presence of extraporal fluids with little to no deviations from the expectations. These results may be a significant step towards application of diffusion pore imaging to biological samples. While still ultra-high gradients are required, this problem may be mitigated by recent developments in the field of local gradient coils for human applications.
△ Less
Submitted 10 October, 2021;
originally announced October 2021.
-
Implementation of GENFIT2 as an experiment independent track-fitting framework
Authors:
Tadeas Bilka,
Nils Braun,
Thomas Hauth,
Thomas Kuhr,
Lia Lavezzi,
Felix Metzner,
Stephan Paul,
Elisabetta Prencipe,
Markus Prim,
Johannes Rauch,
James Ritman,
Tobias Schlueter,
Stefano Spataro
Abstract:
The GENFIT toolkit, initially developed at the Technische Universitaet Muenchen, has been extended and modified to be more general and user-friendly. The new GENFIT, called GENFIT2, provides track representation, track-fitting algorithms and graphic visualization of tracks and detectors, and it can be used for any experiment that determines parameters of charged particle trajectories from spacial…
▽ More
The GENFIT toolkit, initially developed at the Technische Universitaet Muenchen, has been extended and modified to be more general and user-friendly. The new GENFIT, called GENFIT2, provides track representation, track-fitting algorithms and graphic visualization of tracks and detectors, and it can be used for any experiment that determines parameters of charged particle trajectories from spacial coordinate measurements. Based on general Kalman filter routines, it can perform extrapolations of track parameters and covariance matrices. It also provides interfaces to Millepede II for alignment purposes, and RAVE for the vertex finder. Results of an implementation of GENFIT2 in basf2 and PandaRoot software frameworks are presented here.
△ Less
Submitted 13 February, 2019; v1 submitted 12 February, 2019;
originally announced February 2019.
-
A Large Ungated TPC with GEM Amplification
Authors:
M. Berger,
M. Ball,
L. Fabbietti,
B. Ketzer,
R. Arora,
R. Beck,
F. Böhmer,
J. -C. Chen,
F. Cusanno,
S. Dørheim,
J. Hehner,
N. Herrmann,
C. Höppner,
D. Kaiser,
M. Kis,
V. Kleipa,
I. Konorov,
J. Kunkel,
N. Kurz,
Y. Leifels,
P. Müllner,
R. Münzer,
S. Neubert,
J. Rauch,
C. J. Schmidt
, et al. (6 additional authors not shown)
Abstract:
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons…
▽ More
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC).
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector
Authors:
S. A. Uzunyan,
G. Blazey,
S. Boi,
G. Coutrakon,
A. Dyshkant,
K. Francis,
D. Hedin,
E. Johnson,
J. Kalnins,
V. Zutshi,
R. Ford,
J. E. Rauch,
P. Rubinov,
G. Sellberg,
P. Wilson,
M. Naimuddin
Abstract:
Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack…
▽ More
Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.
△ Less
Submitted 4 January, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
Development of a proton Computed Tomography Detector System
Authors:
Md. Naimuddin,
G. Coutrakon,
G. Blazey,
S. Boi,
A. Dyshkant,
B. Erdelyi,
D. Hedin,
E. Johnson,
J. Krider,
V. Rukalin,
S. A. Uzunyan,
V. Zutshi,
R. Fordt,
G. Sellberg,
J. E. Rauch,
M. Roman,
P. Rubinov,
P. Wilson
Abstract:
Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with…
▽ More
Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.
△ Less
Submitted 1 October, 2015;
originally announced October 2015.
-
GENFIT - a Generic Track-Fitting Toolkit
Authors:
Johannes Rauch,
Tobias Schlüter
Abstract:
GENFIT is an experiment-independent track-fitting toolkit that combines fitting algorithms, track representations, and measurement geometries into a modular framework. We report on a significantly improved version of GENFIT, based on experience gained in the Belle II, PANDA, and FOPI experiments. Improvements concern the implementation of additional track-fitting algorithms, enhanced implementatio…
▽ More
GENFIT is an experiment-independent track-fitting toolkit that combines fitting algorithms, track representations, and measurement geometries into a modular framework. We report on a significantly improved version of GENFIT, based on experience gained in the Belle II, PANDA, and FOPI experiments. Improvements concern the implementation of additional track-fitting algorithms, enhanced implementations of Kalman fitters, enhanced visualization capabilities, and additional implementations of measurement types suited for various kinds of tracking detectors. The data model has been revised, allowing for efficient track merging, smoothing, residual calculation, alignment, and storage.
△ Less
Submitted 10 October, 2016; v1 submitted 14 October, 2014;
originally announced October 2014.
-
A New Proton CT Scanner
Authors:
S. A. Uzunyan,
G. Blazey,
S. Boi,
G. Coutrakon,
A. Dyshkant,
B. Erdelyi,
D. Hedin,
E. Johnson,
J. Krider,
V. Rykalin,
V. Zutshi,
R. Ford,
G. Sellberg,
J . E. Rauch,
M. Roman,
P. Rubinov,
P. Wilson,
M. Naimuddin
Abstract:
The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) st…
▽ More
The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm$^2$, for imaging an adult head phantom and reconstructing more accurate RSP values.
△ Less
Submitted 4 January, 2016; v1 submitted 29 August, 2014;
originally announced September 2014.
-
Self-focused beams to couple light into a whispering-gallery mode resonator
Authors:
Kien Phan Huy,
Jassem Safioui,
Jean-Yves Rauch,
Patrice Féron,
Mathieu Chauvet
Abstract:
We propose an original method to couple light into a whispering-gallery mode resonator. This method benefits from the mode selectivity and robustness of the prism-coupling along with the single-mode propagation of the fiber taper. It consists in a prism shaped crystal with a waveguide inscribed inside it. The waveguide is self-inscribed in-situ by beam self-trapping to allow an optimum coupling to…
▽ More
We propose an original method to couple light into a whispering-gallery mode resonator. This method benefits from the mode selectivity and robustness of the prism-coupling along with the single-mode propagation of the fiber taper. It consists in a prism shaped crystal with a waveguide inscribed inside it. The waveguide is self-inscribed in-situ by beam self-trapping to allow an optimum coupling to a given resonator.
△ Less
Submitted 7 July, 2014;
originally announced July 2014.
-
Demonstrator of the Belle II Online Tracking and Pixel Data Reduction on the High Level Trigger System
Authors:
T. Bilka,
G. Casarosa,
R. Frühwirth,
C. Kleinwort,
P. Kodys,
P. Kvasnicka,
J. Lettenbichler,
E. Paoloni,
J. Rauch,
T. Schlüter,
S. Yashchenko
Abstract:
The future Belle II experiment will employ a computer-farm based data reduction system for the readout of its innermost detector, a DEPFET-technology based silicon detector with pixel readout. A large fraction of the background hits can be rejected by defining a set of Regions Of Interest (ROI) on the pixel detector sensors and then recording just the data from the pixels inside the ROI. The ROIs…
▽ More
The future Belle II experiment will employ a computer-farm based data reduction system for the readout of its innermost detector, a DEPFET-technology based silicon detector with pixel readout. A large fraction of the background hits can be rejected by defining a set of Regions Of Interest (ROI) on the pixel detector sensors and then recording just the data from the pixels inside the ROI. The ROIs are defined on an event by event basis by extrapolating back onto the PXD the charged tracks detected in the outer trackers (a 4 layer double-sided silicon strip detector surrounded by a wire chamber). The tracks are reconstructed in real time on the High Level Trigger (HLT). The pixel detector is then read out based on the ROI information. A demonstrator of this architecture was under beam test earlier this year in DESY (Hamburg, Germany). The demonstrator was operated in an electron beam whose momentum was in the 2-6 GeV/c range with a typical trigger rate of a few kHz in a magnetic field of strength up to 1 T. The demonstrator consists of one pixel sensor and 4 silicon strip sensors arranged in a 5 layers configuration mimicking the Belle II vertex detector. The detector readout was a scaled down version of the full Belle II DAQ + HLT chain. The demonstrator was used to detect the particles, reconstruct in real time the trajectories, identify the ROIs on the PXD plane and record the PXD data within. We describe the requirements and the architecture of the final system together with the results obtained with the demonstrator.
△ Less
Submitted 2 April, 2015; v1 submitted 19 June, 2014;
originally announced June 2014.
-
Development of a proton Computed Tomography (pCT) scanner at NIU
Authors:
S. A. Uzunyan,
G. Blazey,
S. Boi,
G. Coutrakon,
A. Dyshkant,
B. Erdelyi,
A. Gearhart,
D. Hedin,
E. Johnson,
J. Krider,
V. Zutshi,
R. Ford,
T. Fitzpatrick,
G. Sellberg,
J. E. Rauch,
M. Roman,
P. Rubinov,
P. Wilson,
K. Lalwani,
M. Naimuddin
Abstract:
We describe the development of a proton Computed Tomography (pCT) scanner at Northern Illinois University (NIU) in collaboration with Fermilab and Delhi University. This paper provides an overview of major components of the scanner and a detailed description of the data acquisition system (DAQ).
We describe the development of a proton Computed Tomography (pCT) scanner at Northern Illinois University (NIU) in collaboration with Fermilab and Delhi University. This paper provides an overview of major components of the scanner and a detailed description of the data acquisition system (DAQ).
△ Less
Submitted 13 December, 2013;
originally announced December 2013.
-
Space-Charge Effects in an Ungated GEM-based TPC
Authors:
F. V. Böhmer,
M. Ball,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
M. Vandenbroucke
Abstract:
A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts t…
▽ More
A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts trigger rates to a few hundred per second. The ion gate can be eliminated from the setup by the use of Gas Electron Multiplier (GEM) foils for gas amplification, which intrinsically suppress the backflow of ions. This makes the continuous operation of a TPC at high rates feasible.
In this work, Monte Carlo simulations of the buildup of ion space charge in a GEM-based TPC and the correction of the resulting drift distortions are discussed, based on realistic numbers for the ion backflow in a triple-GEM amplification stack. A TPC in the future PANDA experiment at FAIR, in which antiproton-proton interaction rates up to 2 x 10^7 per second will be reached, serves as an example for the experimental environment. The simulations show that space charge densities up to 65 fC per cubic cm are reached, leading to electron drift distortions of up to 10 mm. The application of a laser calibration system to correct these distortions is investigated. Based on full simulations of the detector physics and response, we show that it is possible to correct for the drift distortions and to maintain the good momentum resolution of the GEM-TPC.
△ Less
Submitted 3 September, 2012;
originally announced September 2012.
-
Technical Design Study for the PANDA Time Projection Chamber
Authors:
M. Ball,
F. V. Böhmer,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
S. Uhl,
M. Vandenbroucke,
M. Berger,
J. -C. Berger-Chen,
F. Cusanno,
L. Fabbietti,
R. Münzer,
R. Arora,
J. Frühauf,
M. Kiš,
Y. Leifels,
V. Kleipa,
J. Hehner,
J. Kunkel,
N. Kurz,
K. Peters
, et al. (16 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
△ Less
Submitted 29 June, 2012;
originally announced July 2012.