Effects of Temperature Anneal Cycling on a Cryogenically Proton Irradiated CCD
Authors:
S. Parsons,
T. Buggey,
A. Holland,
S. Sembay,
G. Randall,
O. Hetherington,
D. Yeoman,
D. Hall,
P. Verhoeve,
M. Soman
Abstract:
Throughout a typical Earth orbit a satellite is constantly bombarded by radiation with trapped and solar protons being of particular concern as they gradually damage the focal plane devices throughout the mission and degrade their performance. To understand the impact the damage has on CCDs and how it varies with their thermal history a proton radiation campaign has been carried out using a CCD280…
▽ More
Throughout a typical Earth orbit a satellite is constantly bombarded by radiation with trapped and solar protons being of particular concern as they gradually damage the focal plane devices throughout the mission and degrade their performance. To understand the impact the damage has on CCDs and how it varies with their thermal history a proton radiation campaign has been carried out using a CCD280. The CCD is irradiated at 153 K and gradually warmed to 188 K in 5 K increments with Fe55 X-ray, dark current and trap pumping images taken at 153 K after each anneal step.
The results show that despite the trap landscape changing throughout the anneal it has little impact on parallel charge transfer inefficiency. This is thought to be because most traps are unaffected and a lot of those that do anneal only move from the continuum between distinct trap species and into a nearby divacancy trap 'peak' whose emission time constant is similar enough to still impact the CTI.
In terms of using a CCD280 or similar devices in a mission the CTI being unaffected by thermal annealing up to 188 K means that any CTI correction needed as the radiation damage builds up does not have to take into account the thermal history of the focal plane. However, it is possible that a significant amount of annealing will occur at temperatures greater than 188 K and care should be taken when a mission is operating in this range to gather accurate pre-flight data.
△ Less
Submitted 18 October, 2021;
originally announced October 2021.
-
Design and Operation of a Windowless Gas Target Internal to a Solenoidal Magnet for Use with a Megawatt Electron Beam
Authors:
S. Lee,
R. Corliss,
I. Friščić,
R. Alarcon,
S. Aulenbacher,
J. Balewski,
S. Benson,
J. C. Bernauer,
J. Bessuille,
J. Boyce,
J. Coleman,
D. Douglas,
C. S. Epstein,
P. Fisher,
S. Frierson,
M. Garçon,
J. Grames,
D. Hasell,
C. Hernandez-Garcia,
E. Ihloff,
R. Johnston,
K. Jordan,
R. Kazimi,
J. Kelsey,
M. Kohl
, et al. (15 additional authors not shown)
Abstract:
A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamli…
▽ More
A windowless hydrogen gas target of nominal thickness $10^{19}$ cm$^{-2}$ is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Lab's Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic equilibrium was simulated in COMSOL to provide a better understanding of its optimal operation at other working points. We have determined that a windowless gas target with sufficiently high density for DarkLight's experimental needs is feasible in an ERL environment.
△ Less
Submitted 30 May, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
The DarkLight Experiment: A Precision Search for New Physics at Low Energies
Authors:
J. Balewski,
J. Bernauer,
J. Bessuille,
R. Corliss,
R. Cowan,
C. Epstein,
P. Fisher,
D. Hasell,
E. Ihloff,
Y. Kahn,
J. Kelsey,
R. Milner,
S. Steadman,
J. Thaler,
C. Tschalaer,
C. Vidal,
S. Benson,
J. Boyce,
D. Douglas,
P. Evtushenko,
C. Hernandez-Garcia,
C. Keith,
C. Tennant,
S. Zhang,
R. Alarcon
, et al. (15 additional authors not shown)
Abstract:
We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac inc…
▽ More
We describe the current status of the DarkLight experiment at Jefferson Laboratory. DarkLight is motivated by the possibility that a dark photon in the mass range 10 to 100 MeV/c$^2$ could couple the dark sector to the Standard Model. DarkLight will precisely measure electron proton scattering using the 100 MeV electron beam of intensity 5 mA at the Jefferson Laboratory energy recovering linac incident on a windowless gas target of molecular hydrogen. The complete final state including scattered electron, recoil proton, and e+e- pair will be detected. A phase-I experiment has been funded and is expected to take data in the next eighteen months. The complete phase-II experiment is under final design and could run within two years after phase-I is completed. The DarkLight experiment drives development of new technology for beam, target, and detector and provides a new means to carry out electron scattering experiments at low momentum transfers.
△ Less
Submitted 15 December, 2014;
originally announced December 2014.