-
Mechanical Characterization of Brain Tissue: Experimental Techniques, Human Testing Considerations, and Perspectives
Authors:
Jixin Hou,
Kun Jiang,
Arunachalam Ramanathan,
Abhishek Saji Kumar,
Wei Zhang,
Lin Zhao,
Taotao Wu,
Ramana Pidaparti,
Dajiang Zhu,
Gang Li,
Kenan Song,
Tianming Liu,
Mir Jalil Razavi,
Ellen Kuhl,
Xianqiao Wang
Abstract:
Understanding the mechanical behavior of brain tissue is crucial for advancing both fundamental neuroscience and clinical applications. Yet, accurately measuring these properties remains challenging due to the brain unique mechanical attributes and complex anatomical structures. This review provides a comprehensive overview of commonly used techniques for characterizing brain tissue mechanical pro…
▽ More
Understanding the mechanical behavior of brain tissue is crucial for advancing both fundamental neuroscience and clinical applications. Yet, accurately measuring these properties remains challenging due to the brain unique mechanical attributes and complex anatomical structures. This review provides a comprehensive overview of commonly used techniques for characterizing brain tissue mechanical properties, covering both invasive methods such as atomic force microscopy, indentation, axial mechanical testing, and oscillatory shear testing and noninvasive approaches like magnetic resonance elastography and ultrasound elastography. Each technique is evaluated in terms of working principles, applicability, representative studies, and experimental limitations. We further summarize existing publications that have used these techniques to measure human brain tissue mechanical properties. With a primary focus on invasive studies, we systematically compare their sample preparation, testing conditions, reported mechanical parameters, and modeling strategies. Key sensitivity factors influencing testing outcomes (e.g., sample size, anatomical location, strain rate, temperature, conditioning, and post-mortem interval) are also discussed. Additionally, selected noninvasive studies are reviewed to assess their potential for in vivo characterization. A comparative discussion between invasive and noninvasive methods, as well as in vivo versus ex vivo testing, is included. This review aims to offer practical guidance for researchers and clinicians in selecting appropriate mechanical testing approaches and contributes a curated dataset to support constitutive modeling of human brain tissue.
△ Less
Submitted 20 April, 2025; v1 submitted 15 April, 2025;
originally announced April 2025.
-
Pandemic Drugs at Pandemic Speed: Infrastructure for Accelerating COVID-19 Drug Discovery with Hybrid Machine Learning- and Physics-based Simulations on High Performance Computers
Authors:
Agastya P. Bhati,
Shunzhou Wan,
Dario Alfè,
Austin R. Clyde,
Mathis Bode,
Li Tan,
Mikhail Titov,
Andre Merzky,
Matteo Turilli,
Shantenu Jha,
Roger R. Highfield,
Walter Rocchia,
Nicola Scafuri,
Sauro Succi,
Dieter Kranzlmüller,
Gerald Mathias,
David Wifling,
Yann Donon,
Alberto Di Meglio,
Sofia Vallecorsa,
Heng Ma,
Anda Trifan,
Arvind Ramanathan,
Tom Brettin,
Alexander Partin
, et al. (4 additional authors not shown)
Abstract:
The race to meet the challenges of the global pandemic has served as a reminder that the existing drug discovery process is expensive, inefficient and slow. There is a major bottleneck screening the vast number of potential small molecules to shortlist lead compounds for antiviral drug development. New opportunities to accelerate drug discovery lie at the interface between machine learning methods…
▽ More
The race to meet the challenges of the global pandemic has served as a reminder that the existing drug discovery process is expensive, inefficient and slow. There is a major bottleneck screening the vast number of potential small molecules to shortlist lead compounds for antiviral drug development. New opportunities to accelerate drug discovery lie at the interface between machine learning methods, in this case developed for linear accelerators, and physics-based methods. The two in silico methods, each have their own advantages and limitations which, interestingly, complement each other. Here, we present an innovative infrastructural development that combines both approaches to accelerate drug discovery. The scale of the potential resulting workflow is such that it is dependent on supercomputing to achieve extremely high throughput. We have demonstrated the viability of this workflow for the study of inhibitors for four COVID-19 target proteins and our ability to perform the required large-scale calculations to identify lead antiviral compounds through repurposing on a variety of supercomputers.
△ Less
Submitted 4 September, 2021; v1 submitted 4 March, 2021;
originally announced March 2021.
-
Spectroscopic measurements of a CO2 absorption line in an open vertical path using an airborne lidar
Authors:
Anand Ramanathan,
Jianping Mao,
Graham R Allan,
Haris Riris,
Clark J Weaver,
William E Hasselbrack,
Edward V Browell,
James B Abshire
Abstract:
We use an airborne pulsed integrated path differential absorption lidar to make spectroscopic measurements of the pressure-induced line broadening and line center shift of atmospheric CO2 at the 1572.335 nm absorption line. We measure the absorption lineshape in the vertical column between the aircraft and ground. A comparison of our measured absorption lineshape to calculations based on HITRAN sh…
▽ More
We use an airborne pulsed integrated path differential absorption lidar to make spectroscopic measurements of the pressure-induced line broadening and line center shift of atmospheric CO2 at the 1572.335 nm absorption line. We measure the absorption lineshape in the vertical column between the aircraft and ground. A comparison of our measured absorption lineshape to calculations based on HITRAN shows excellent agreement with the peak optical depth accurate to within 0.3%. Additionally, we measure changes in the line center position to within 5.2 MHz of calculations, and the absorption linewidth to within 0.6% of calculations.
△ Less
Submitted 2 August, 2013;
originally announced August 2013.
-
Partial-Transfer Absorption Imaging: A versatile technique for optimal imaging of ultracold gases
Authors:
Anand Ramanathan,
Sérgio R. Muniz,
Kevin C. Wright,
Russell P. Anderson,
William D. Phillips,
Kristian Helmerson,
Gretchen K. Campbell
Abstract:
Partial-transfer absorption imaging is a tool that enables optimal imaging of atomic clouds for a wide range of optical depths. In contrast to standard absorption imaging, the technique can be minimally-destructive and can be used to obtain multiple successive images of the same sample. The technique involves transferring a small fraction of the sample from an initial internal atomic state to an a…
▽ More
Partial-transfer absorption imaging is a tool that enables optimal imaging of atomic clouds for a wide range of optical depths. In contrast to standard absorption imaging, the technique can be minimally-destructive and can be used to obtain multiple successive images of the same sample. The technique involves transferring a small fraction of the sample from an initial internal atomic state to an auxiliary state and subsequently imaging that fraction absorptively on a cycling transition. The atoms remaining in the initial state are essentially unaffected. We demonstrate the technique, discuss its applicability, and compare its performance as a minimally-destructive technique to that of phase-contrast imaging.
△ Less
Submitted 29 June, 2012;
originally announced June 2012.