Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams
Authors:
J. Balibrea-Correa,
V. Babiano-Suarez,
J. Lerendegui-Marco,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
G. de la Fuente-Rosales,
B. Gameiro,
N. Zaitseva,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
A. Pérez de Rada,
J. Plaza del Olmo,
A. Sánchez-Caballero,
A. Casanovas,
F. Calviño,
S. Valenta,
O. Aberle,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak
, et al. (112 additional authors not shown)
Abstract:
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called $γ$-flash, and offer the highest possible detection sensitivity. In this paper, we…
▽ More
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called $γ$-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps toward such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n\_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C$_{6}$D$_{6}$ detectors, and one LaCl$_{3}$(Ce) detector. The performance of these detection systems is compared using $^{93}$Nb($n$,$γ$) data. We also developed a detailed \textsc{Geant4} Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a $γ$ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigaged experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.
△ Less
Submitted 28 November, 2024;
originally announced November 2024.
-
Application of Information Theory in Rumor Spreading Modeling Considering Polarization in Complex Networks
Authors:
Patrick Oliveira de Paula,
Alejandra Rada,
Catalina Rúa
Abstract:
It is proposed a model that makes use of the Entropy concept and the Jensen-Shannon information divergence function to simulate computationally the dissemination of opinions on a Barabási-Albert (BA) scale-free network. The simulation considers individual memory, ideological proximity between individuals, and distortion influenced by polarization.
It is proposed a model that makes use of the Entropy concept and the Jensen-Shannon information divergence function to simulate computationally the dissemination of opinions on a Barabási-Albert (BA) scale-free network. The simulation considers individual memory, ideological proximity between individuals, and distortion influenced by polarization.
△ Less
Submitted 7 August, 2024;
originally announced August 2024.
-
A Segmented Total Energy Detector (sTED) optimized for $(n,γ)$ cross-section measurements at n_TOF EAR2
Authors:
V. Alcayne,
D. Cano-Ott,
J. Garcia,
E. Gonzalez-Romero,
T. Martinez,
A. Perez de Rada,
J. Plaza,
A. Sanchez-Caballero,
J. Balibrea-Correa,
C. Domingo-Pardo,
J. Lerendegui-Marco,
A. Casanovas,
F. Calvino,
O. Aberle,
the n_TOF collaboration
Abstract:
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Expe…
▽ More
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Experimental ARea 1 (EAR1) of $8\times10^5$ neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detectors response, by reducing the active volume per module and by using a photomultiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to $γ$-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2.
△ Less
Submitted 14 March, 2024;
originally announced March 2024.
-
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
Authors:
J. Balibrea Correa,
J. Lerendegui-Marco,
V. Babiano-Suarez,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
A. Pérez de Rada,
J. Plaza del Olmo,
A. Sánchez-Caballero,
A. Casanovas,
F. Calviño,
S. Valenta,
O. Aberle,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes
, et al. (109 additional authors not shown)
Abstract:
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects…
▽ More
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
Commissioning of miniBELEN-10A, a moderated neutron counter with a flat efficiency for thick-target neutron yields measurements
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
G Garcia,
E Nácher,
J L Tain,
V Alcayne,
O Alonso-Sañudo,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
J Gómez-Camacho,
E M González-Romero
, et al. (18 additional authors not shown)
Abstract:
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron…
▽ More
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron yields from 27Al(alpha, n)30P.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
miniBELEN: a modular neutron counter for (alpha,n) reactions
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
E Nácher,
J L Tain,
V Alcayne,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
G García,
J Gómez-Camacho,
E M González-Romero,
C Guerrero
, et al. (16 additional authors not shown)
Abstract:
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming…
▽ More
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (alpha,n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using 252Cf sources and the measurement of the 27Al(alpha,n)30P reaction is also presented.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements
Authors:
N. Patronis,
A. Mengoni,
N. Colonna,
M. Cecchetto,
C. Domingo-Pardo,
O. Aberle,
J. Lerendegui-Marco,
G. Gervino,
M. E. Stamati,
S. Goula,
A. P. Bernardes,
M. Mastromarco,
A. Manna,
R. Vlastou,
C. Massimi,
M. Calviani,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
V. Babiano-Suarez,
M. Bacak,
J. Balibrea,
C. Beltrami,
S. Bennett
, et al. (108 additional authors not shown)
Abstract:
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to th…
▽ More
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
The role of multiple repetitions on the size of a rumor
Authors:
Alejandra Rada,
Cristian F. Coletti,
Elcio Lebensztayn,
Pablo M. Rodriguez
Abstract:
We propose a mathematical model to measure how multiple repetitions may influence in the ultimate proportion of the population never hearing a rumor during a given outbreak. The model is a multi-dimensional continuous-time Markov chain that can be seen as a generalization of the Maki-Thompson model for the propagation of a rumor within a homogeneously mixing population. In the well-known basic mod…
▽ More
We propose a mathematical model to measure how multiple repetitions may influence in the ultimate proportion of the population never hearing a rumor during a given outbreak. The model is a multi-dimensional continuous-time Markov chain that can be seen as a generalization of the Maki-Thompson model for the propagation of a rumor within a homogeneously mixing population. In the well-known basic model, the population is made up of "spreaders", "ignorants" and "stiflers", and any spreader attempts to transmit the rumor to the other individuals via directed contacts. In case the contacted individual is an ignorant, it becomes a spreader, while in the other two cases the initiating spreader turns into a stifler. The process in a finite population will eventually reach an equilibrium situation, where individuals are either stiflers or ignorants. We generalize the model by assuming that each ignorant becomes a spreader only after hearing the rumor a predetermined number of times. We identify and analyze a suitable limiting dynamical system of the model, and we prove limit theorems that characterize the ultimate proportion of individuals in the different classes of the population.
△ Less
Submitted 7 May, 2021; v1 submitted 14 June, 2020;
originally announced June 2020.
-
Characterization of a CLYC detector for underground experiments
Authors:
T. Martinez,
A. Pérez de Rada,
D. Cano-Ott,
R. Santorelli,
I. Bandac,
P. Garcia Abia,
A. R. Garcia,
A. Ianni,
B. Montes,
L. Romero,
D. Villamarin
Abstract:
Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $γ$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to their novelty, the comprehensive characterization of the performance of individual CLYC detectors is of great importance for determining their range of applicability.…
▽ More
Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $γ$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to their novelty, the comprehensive characterization of the performance of individual CLYC detectors is of great importance for determining their range of applicability. In this work we report on a wide series measurements performed with a commercial 2"x2" CLYC crystal. Good energy and timing resolution values of 4.7% (@ 662 keV) and 1340 ps (FWHM), respectively, were achieved, and a neutron/$γ$ separation figure of merit value of 4.2 was obtained. A dedicated measurement for investigating the intrinsic background of the detector was performed at the Laboratorio Subterráneo de Canfranc (Spain). It evidenced a sizeable contamination in the detector materials which poses limits in the use of CLYC in low background experiments. In addition, detailed Monte Carlo simulations with the GEANT4 toolkit were performed for modeling the response function of the CLYC detector to gamma-rays. An excellent agreement with the experimental data has been achieved.
△ Less
Submitted 6 October, 2017;
originally announced October 2017.