-
Feasibility study of multiplexing analog signals from SiPMs for a single layer monolithic PET detector design
Authors:
Shiv K. Subedi,
Simon R. Cherry,
Yi Qiang,
Peng Peng
Abstract:
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In this work, a simulation study of a single layer monolithic detector module was performed with side read out of scintillation light using GATEv8.2. In this design,…
▽ More
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In this work, a simulation study of a single layer monolithic detector module was performed with side read out of scintillation light using GATEv8.2. In this design, a single layer LSO crystal was used with dimensions 40 mm*40 mm*40 mm, with 0.60 mm thickness of the ESR (enhanced specular reflector) films covering the crystal's top and bottom surfaces. The photons generated in the scintillation process induced by the gamma ray hitting the crystal were detected by four 1*8 SiPM (silicon photomultiplier) arrays placed along the four sides of the crystal. The scintillation light distribution detected by all of the 32 SiPMs surrounding the crystal layer was then used to extract the gamma-crystal interaction location based on machine learning analysis. In this work, the spatial resolution of the detector module was explored when analog signals from each of the 32 SiPMs were summed to 28, 24, 20, 16, 12, 8, and 4 total outputs. This study showed that good spatial resolution can be achieved even when the number of read out channels is decreased by multiplexing, which can reduce the overall detector manufacturing cost.
△ Less
Submitted 11 February, 2025;
originally announced February 2025.
-
Observation of fractional evolution in nonlinear optics
Authors:
Van Thuy Hoang,
Justin Widjaja,
Y. Long Qiang,
Maxwell Liu,
Tristram J. Alexander,
Antoine F. J. Runge,
C. Martijn de Sterke
Abstract:
The idea of fractional derivatives has a long history that dates back centuries. Apart from their intriguing mathematical properties, fractional derivatives have been studied widely in physics, for example in quantum mechanics and generally in systems with nonlocal temporal or spatial interactions. However, systematic experiments have been rare due to challenges associated with the physical implem…
▽ More
The idea of fractional derivatives has a long history that dates back centuries. Apart from their intriguing mathematical properties, fractional derivatives have been studied widely in physics, for example in quantum mechanics and generally in systems with nonlocal temporal or spatial interactions. However, systematic experiments have been rare due to challenges associated with the physical implementation. Here we report the observation and full characterization of a family of temporal optical solitons that are governed by a nonlinear wave equation with a fractional Laplacian. This equation has solutions with unique properties such as non-exponential tails and a very small time-bandwidth product.
△ Less
Submitted 31 October, 2024;
originally announced October 2024.
-
Condensate Size Control by Net Charge
Authors:
Chengjie Luo,
Nathaniel Hess,
Dilimulati Aierken,
Yicheng Qiang,
Jerelle A. Joseph,
David Zwicker
Abstract:
Biomolecular condensates are complex droplets comprising diverse molecules that interact using various mechanisms. Condensation is often driven by short-ranged attraction, but net charges can also mediate long-ranged repulsion. Using molecular dynamics simulations and an equilibrium field theory, we show that such opposing interactions can suppress coarsening so that many droplets of equal size co…
▽ More
Biomolecular condensates are complex droplets comprising diverse molecules that interact using various mechanisms. Condensation is often driven by short-ranged attraction, but net charges can also mediate long-ranged repulsion. Using molecular dynamics simulations and an equilibrium field theory, we show that such opposing interactions can suppress coarsening so that many droplets of equal size coexist at equilibrium. This size control depends strongly on the charge asymmetry between constituents, while the strength of the short-ranged attractions has a weak influence. Essentially, droplets expel ions, so they cannot screen electrostatics effectively, implying droplets acquire a net charge and cannot grow indefinitely. Our work reveals how electrostatic effects control droplet size, which is relevant for understanding biomolecular condensates and creating synthetic patterns in chemical engineering.
△ Less
Submitted 22 January, 2025; v1 submitted 23 September, 2024;
originally announced September 2024.
-
Ptychographic non-line-of-sight imaging for depth-resolved visualization of hidden objects
Authors:
Pengming Song,
Qianhao Zhao,
Ruihai Wang,
Ninghe Liu,
Yingqi Qiang,
Tianbo Wang,
Xincheng Zhang,
Yi Zhang,
Guoan Zheng
Abstract:
Non-line-of-sight (NLOS) imaging enables the visualization of objects hidden from direct view, with applications in surveillance, remote sensing, and light detection and ranging. Here, we introduce a NLOS imaging technique termed ptychographic NLOS (pNLOS), which leverages coded ptychography for depth-resolved imaging of obscured objects. Our approach involves scanning a laser spot on a wall to il…
▽ More
Non-line-of-sight (NLOS) imaging enables the visualization of objects hidden from direct view, with applications in surveillance, remote sensing, and light detection and ranging. Here, we introduce a NLOS imaging technique termed ptychographic NLOS (pNLOS), which leverages coded ptychography for depth-resolved imaging of obscured objects. Our approach involves scanning a laser spot on a wall to illuminate the hidden objects in an obscured region. The reflected wavefields from these objects then travel back to the wall, get modulated by the wall's complex-valued profile, and the resulting diffraction patterns are captured by a camera. By modulating the object wavefields, the wall surface serves the role of the coded layer as in coded ptychography. As we scan the laser spot to different positions, the reflected object wavefields on the wall translate accordingly, with the shifts varying for objects at different depths. This translational diversity enables the acquisition of a set of modulated diffraction patterns referred to as a ptychogram. By processing the ptychogram, we recover both the objects at different depths and the modulation profile of the wall surface. Experimental results demonstrate high-resolution, high-fidelity imaging of hidden objects, showcasing the potential of pNLOS for depth-aware vision beyond the direct line of sight.
△ Less
Submitted 1 September, 2024; v1 submitted 17 May, 2024;
originally announced May 2024.
-
Generic multicomponent mixtures are multistable
Authors:
Yicheng Qiang,
Chengjie Luo,
David Zwicker
Abstract:
Liquid mixtures of many interacting components often exhibit numerous coexisting types of droplets. An exciting example is the cytosol of biological cells, where diverse droplets, called condensates, are essential for cellular function. However, how much their formation is constrained by thermodynamics is currently unclear. Linear stability analysis predicts that homogeneous mixtures become more r…
▽ More
Liquid mixtures of many interacting components often exhibit numerous coexisting types of droplets. An exciting example is the cytosol of biological cells, where diverse droplets, called condensates, are essential for cellular function. However, how much their formation is constrained by thermodynamics is currently unclear. Linear stability analysis predicts that homogeneous mixtures become more robust to fluctuations as the number of components increases, suggesting that droplets do not form easily in multicomponent mixtures. In contrast, we show through numerical simulations and analytical scaling laws that the number of coexisting phases typically increases with the number of components in equilibrium. The combination of both results suggests that generic multicomponent mixtures can maintain many metastable states with various droplets, generalizing the nucleation-and-growth regime of binary mixtures. Our theory also indicates why cells exhibit much fewer condensates than components and how they could exploit multistability to independently form various condensates.
△ Less
Submitted 27 May, 2025; v1 submitted 2 May, 2024;
originally announced May 2024.
-
Beyond Pairwise: Higher-order physical interactions affect phase separation in multi-component liquids
Authors:
Chengjie Luo,
Yicheng Qiang,
David Zwicker
Abstract:
Phase separation, crucial for spatially segregating biomolecules in cells, is well-understood in the simple case of a few components with pairwise interactions. Yet, biological cells challenge the simple picture in at least two ways: First, biomolecules, like proteins and nucleic acids, exhibit complex, higher-order interactions, where a single molecule may interact with multiple others simultaneo…
▽ More
Phase separation, crucial for spatially segregating biomolecules in cells, is well-understood in the simple case of a few components with pairwise interactions. Yet, biological cells challenge the simple picture in at least two ways: First, biomolecules, like proteins and nucleic acids, exhibit complex, higher-order interactions, where a single molecule may interact with multiple others simultaneously. Second, cells comprise a myriad of different components that form various droplets. Such multicomponent phase separation has been studied in the simple case of pairwise interactions, but an analysis of higher-order interactions is lacking. We propose such a theory and study the corresponding phase diagrams numerically. We find that interactions between three components are similar to pairwise interactions, whereas composition-dependent higher-order interactions between two components can oppose phase separation. This surprising result can only be revealed from the equilibrium phase diagrams, implying that the often-used stability analysis of homogeneous states is inadequate to study these systems. We thus show that higher-order interactions could play a crucial role in forming droplets in cells, and their manipulation could offer novel approaches to controlling multicomponent phase separation.
△ Less
Submitted 11 March, 2024;
originally announced March 2024.
-
Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies
Authors:
Xiaohui Zhan,
Ruoqiao Zhang,
Xiaofeng Niu,
Ilmar Hein,
Brent Budden,
Shuoxing Wu,
Nicolay Markov,
Cameron Clarke,
Yi Qiang,
Hiroki Taguchi,
Keiichi Nomura,
Yoshihisa Muramatsu,
Zhou Yu,
Tatsushi Kobayashi,
Richard Thompson,
Hiroaki Miyazaki,
Hiroaki Nakai
Abstract:
Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better contrast, noise and spatial resolution performance compared to conventional scintillator-based systems. With multi-energy threshold detection, PCD can simultaneousl…
▽ More
Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better contrast, noise and spatial resolution performance compared to conventional scintillator-based systems. With multi-energy threshold detection, PCD can simultaneously provide the photon energy measurement and enable material decomposition for spectral imaging. In this work, we report a performance evaluation of our first CdZnTe-based prototype full-size photon counting CT system through various phantom imaging studies. This prototype system supports a 500 mm scan field-of-view (FOV) and 10 mm cone coverage at isocenter. Phantom scans were acquired using 120 kVp from 50 to 400 mAs to assess the imaging performance on: CT number accuracy, uniformity, noise, spatial resolution, material differentiation and quantification. Both qualitative and quantitative evaluations show that PCCT has superior imaging performance with lower noise and improved spatial resolution compared to conventional energy integrating detector (EID)-CT. Using projection domain material decomposition approach with multiple energy bin measurements, PCCT virtual monoenergetic images (VMIs) have lower noise, and superior performance in quantifying iodine and calcium concentrations. These improvements lead to increased contrast-to-noise ratio (CNR) for both high and low contrast study objects compared to EID-CT. PCCT can also generate super-high resolution (SHR) images using much smaller detector pixel size than EID-CT and dramatically improve image spatial resolution.
△ Less
Submitted 10 April, 2023; v1 submitted 26 December, 2022;
originally announced December 2022.
-
The interaction of Kerr nonlinearity with even-orders of dispersion: an infinite hierarchy of solitons
Authors:
Antoine F. J. Runge,
Y. Long Qiang,
Tristram J. Alexander,
Darren D. Hudson,
Andrea Blanco-Redondo,
C. Martijn de Sterke
Abstract:
Temporal solitons are optical pulses that arise from the balance of negative group-velocity dispersion and self-phase modulation. For decades only quadratic dispersion was considered, with higher order dispersion thought of as a nuisance. Following the recent reporting of pure-quartic solitons, we here provide experimental and numerical evidence for an infinite hierarchy of solitons that balance s…
▽ More
Temporal solitons are optical pulses that arise from the balance of negative group-velocity dispersion and self-phase modulation. For decades only quadratic dispersion was considered, with higher order dispersion thought of as a nuisance. Following the recent reporting of pure-quartic solitons, we here provide experimental and numerical evidence for an infinite hierarchy of solitons that balance self-phase modulation and arbitrary negative pure, even-order dispersion. Specifically, we experimentally demonstrate the existence of solitons with pure-sextic ($β_6$), -octic ($β_8$) and -decic ($β_{10}$) dispersion, limited only by the performance of our components, and show numerical evidence for the existence of solitons involving pure $16^{\rm th}$ order dispersion. Phase-resolved temporal and spectral characterization reveals that these pulses, exhibit increasing spectral flatness with dispersion order. The measured energy-width scaling laws suggest dramatic advantages for ultrashort pulses. These results broaden the fundamental understanding of solitons and present new avenues to engineer ultrafast pulses in nonlinear optics and its applications.
△ Less
Submitted 15 September, 2020;
originally announced September 2020.
-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Construction and Performance of the Barrel Electromagnetic Calorimeter for the GlueX Experiment
Authors:
Tegan Beattie,
Ahmed Foda,
Colleen Henschel,
S Katsaganis,
Shaun Krueger,
George Lolos,
Zisis Papandreou,
E. L. Plummer,
Irina Semenova,
Andrei Semenov,
Fernando Barbosa,
Eugene Chudakov,
Mark Dalton,
David Lawrence,
Yi Qiang,
Nicholas Sandoval,
Elton Smith,
Christopher Stanislav,
Justin Stevens,
Simon Taylor,
Timothy Whitlatch,
Benedikt Zihlmann,
William Levine,
William McGinley,
Curtis Meyer
, et al. (14 additional authors not shown)
Abstract:
The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy d…
▽ More
The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described herein. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. We characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for $π^0$ and $η$ production of $σ_E/E$=5.2\%/$\sqrt{E(\rm{GeV})} \oplus$ 3.6\% and a timing resolution of $σ$\,=\,150\,ps at 1\,GeV.
△ Less
Submitted 20 April, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
First Results from The GlueX Experiment
Authors:
The GlueX Collaboration,
H. Al Ghoul,
E. G. Anassontzis,
F. Barbosa,
A. Barnes,
T. D. Beattie,
D. W. Bennett,
V. V. Berdnikov,
T. Black,
W. Boeglin,
W. K. Brooks,
B. Cannon,
O. Chernyshov,
E. Chudakov,
V. Crede,
M. M. Dalton,
A. Deur,
S. Dobbs,
A. Dolgolenko,
M. Dugger,
H. Egiyan,
P. Eugenio,
A. M. Foda,
J. Frye,
S. Furletov
, et al. (86 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and…
▽ More
The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of $π^{0}$, $η$ and $ω$ mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the $ρ$ has been observed.
△ Less
Submitted 14 January, 2016; v1 submitted 11 December, 2015;
originally announced December 2015.
-
A study of decays to strange final states with GlueX in Hall D using components of the BaBar DIRC
Authors:
The GlueX Collaboration,
M. Dugger,
B. Ritchie,
I. Senderovich,
E. Anassontzis,
P. Ioannou,
C. Kourkoumeli,
G. Vasileiadis,
G. Voulgaris,
N. Jarvis,
W. Levine,
P. Mattione,
W. McGinley,
C. A. Meyer,
R. Schumacher,
M. Staib,
F. Klein,
D. Sober,
N. Sparks,
N. Walford,
D. Doughty,
A. Barnes,
R. Jones,
J. McIntyre,
F. Mokaya
, et al. (82 additional authors not shown)
Abstract:
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studi…
▽ More
We propose to enhance the kaon identification capabilities of the GlueX detector by constructing an FDIRC (Focusing Detection of Internally Reflected Cherenkov) detector utilizing the decommissioned BaBar DIRC components. The GlueX FDIRC would significantly enhance the GlueX physics program by allowing one to search for and study hybrid mesons decaying into kaon final states. Such systematic studies of kaon final states are essential for inferring the quark flavor content of hybrid and conventional mesons. The GlueX FDIRC would reuse one-third of the synthetic fused silica bars that were utilized in the BaBar DIRC. A new focussing photon camera, read out with large area photodetectors, would be developed. We propose operating the enhanced GlueX detector in Hall D for a total of 220 days at an average intensity of 5x10^7 γ/s, a program that was conditionally approved by PAC39
△ Less
Submitted 1 August, 2014;
originally announced August 2014.
-
The Development of ADS Virtual Accelerator Based on XAL
Authors:
Wang Peng-Fei,
Cao Jian-She,
Ye Qiang
Abstract:
XAL is a high level accelerator application framework originally developed by the Spallation Neutron Source (SNS), Oak Ridge National Laboratory. It has advanced design concept and adopted by many international accelerator laboratories. Adopting XAL for ADS is a key subject in the long term. This paper will present the modifications to the original XAL applications for ADS. The work includes prope…
▽ More
XAL is a high level accelerator application framework originally developed by the Spallation Neutron Source (SNS), Oak Ridge National Laboratory. It has advanced design concept and adopted by many international accelerator laboratories. Adopting XAL for ADS is a key subject in the long term. This paper will present the modifications to the original XAL applications for ADS. The work includes proper relational database schema modification in order to better suit ADS configuration data requirement, redesigning and re-implementing db2xal application and modifying the virtual accelerator application. In addition, the new device types and new device attributes for ADS online modeling purpose is also described here.
△ Less
Submitted 16 September, 2013;
originally announced September 2013.
-
Radiation Hardness Tests of SiPMs for the JLab Hall D Barrel Calorimeter
Authors:
Yi Qiang,
Carl Zorn,
Fernando Barbosa,
Elton Smith
Abstract:
We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-an…
▽ More
We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-annealing were performed on Hamamatsu SiPMs using a calibrated Am-Be neutron source from the Jefferson Lab Radiation Control group. As the result of irradiation both dark current and dark rate increase linearly as a function of the 1 MeV equivalent neutron fluence and a temperature dependent self-annealing effect is observed.
△ Less
Submitted 18 September, 2012; v1 submitted 16 July, 2012;
originally announced July 2012.