Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events and quasiparticle poisoning in superconducting sensors
Authors:
C. L. Chang,
Y. -Y. Chang,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
M. Lisovenko,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
P. K. Patel,
B. Penning,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
I. Rydstrom,
R. K. Romani,
B. Sadoulet,
B. Serfass,
P. Sorensen,
B. Suerfu,
V. Velan,
G. Wang
, et al. (3 additional authors not shown)
Abstract:
Solid state phonon detectors used in the search for dark matter or coherent neutrino nucleus interactions (CE$ν$NS) require excellent energy resolution (eV-scale or below) and low backgrounds to meet their science objectives. Unfortunately, an unknown source of phonon bursts (the low energy excess, or ``LEE'') both dominates all other above threshold background sources and produces shot noise from…
▽ More
Solid state phonon detectors used in the search for dark matter or coherent neutrino nucleus interactions (CE$ν$NS) require excellent energy resolution (eV-scale or below) and low backgrounds to meet their science objectives. Unfortunately, an unknown source of phonon bursts (the low energy excess, or ``LEE'') both dominates all other above threshold background sources and produces shot noise from sub-threshold bursts which greatly exceeds all fundamental noise sources. In this paper, we measure these phonon bursts for 12 days after cool down in two nearly identical multi-phonon sensor channel 1cm$^2$ silicon detectors which differ only in the thickness of their substrate (1 mm vs 4 mm thick). We find that both the correlated shot noise and near threshold shared LEE relax with time since cooldown. Additionally, we show that both shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise we estimate that $\varepsilon = \frac{<E^2>}{<E>}$ for sub-threshold noise events is $0.68 \pm 0.38$ meV. In our final dataset, we report a world-leading energy resolution of 258.5$\pm$0.4 meV in the 1mm thick detector. Simple calculations suggest that these Si substrate phonon bursts are likely the dominant source of quasi-particle poisoning in superconducting qubits and sensors that are operated in well shielded and vibration free environments.
△ Less
Submitted 22 May, 2025; v1 submitted 21 May, 2025;
originally announced May 2025.
-
First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration
Authors:
C. L. Chang,
Y. -Y. Chang,
L. Chaplinsky,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
M. Lisovenko,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
V. Novati,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani,
B. Sadoulet,
B. Serfass
, et al. (23 additional authors not shown)
Abstract:
We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g…
▽ More
We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g $\times$ 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/$c^2$, with the lowest unexplored cross section of 4 $\times 10^{-32}$ cm$^2$ at 87 MeV/$c^2$. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.
△ Less
Submitted 28 March, 2025; v1 submitted 5 March, 2025;
originally announced March 2025.
-
Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter
Authors:
Robin Anthony-Petersen,
Clarence L. Chang,
Yen-Yung Chang,
Luke Chaplinsky,
Caleb W. Fink,
Maurice Garcia-Sciveres,
Wei Guo,
Scott A. Hertel,
Xinran Li,
Junsong Lin,
Marharyta Lisovenko,
Rupak Mahapatra,
William Matava,
Daniel N. McKinsey,
David Z. Osterman,
Pratyush K. Patel,
Bjoern Penning,
Mark Platt,
Matt Pyle,
Yinghe Qi,
Maggie Reed,
Ivar Rydstrom,
Roger K. Romani,
Bernard Sadoulet,
Bruno Serfass
, et al. (7 additional authors not shown)
Abstract:
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal p…
▽ More
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal phonon events, and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These ``singles'' are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.
△ Less
Submitted 4 April, 2025; v1 submitted 21 October, 2024;
originally announced October 2024.
-
A Transition Edge Sensor Operated in Coincidence with a High Sensitivity Athermal Phonon Sensor for Photon Coupled Rare Event Searches
Authors:
Roger K. Romani,
Yen-Yung Chang,
Rupak Mahapatra,
Mark Platt,
Maggie Reed,
Ivar Rydstrom,
Bernard Sadoulet,
Bruno Serfass,
Matt Pyle
Abstract:
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a small photon sensor, in our case a Transition Edge Sensor (TES) with a photon energy resolution $σ_γ= 368.4 \pm 0.4$ meV, is colocated on the same substrate as a l…
▽ More
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a small photon sensor, in our case a Transition Edge Sensor (TES) with a photon energy resolution $σ_γ= 368.4 \pm 0.4$ meV, is colocated on the same substrate as a large high sensitivity athermal phonon sensor (APS) with a phonon energy resolution $σ_\mathrm{phonon} = 701 \pm 2$ meV. We show that single 3.061 eV photons absorbed in the photon-sensing TES deposit $\sim$35\% of their energy in the electronic system of the TES, while $\sim$26\% of the photon energy leaks out of the photon-sensing TES during the downconversion process and becomes absorbed by the APS. Backgrounds, which we associate with the broadly observed ``low energy excess'' (LEE), are observed to be largely coupled to either the TES (``singles'' LEE), or phonon system, (``shared'' LEE). At high energies, these backgrounds can be efficiently discriminated from TES photon absorption events, while at low energies, their misidentification as photon events is well modeled. With significant sensitivity improvements to both the TES and APS, this coincidence technique could be used to suppress backgrounds in bosonic dark matter searches down to energies near the superconducting bandgap of the sensor.
△ Less
Submitted 28 May, 2025; v1 submitted 20 August, 2024;
originally announced August 2024.
-
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (117 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 5 September, 2024; v1 submitted 10 July, 2024;
originally announced July 2024.
-
First Demonstration of the HeRALD Superfluid Helium Detector Concept
Authors:
R. Anthony-Petersen,
A. Biekert,
C. L. Chang,
Y. Chang,
L. Chaplinsky,
A. Dushkin,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
D. Z. Osterman,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani
, et al. (11 additional authors not shown)
Abstract:
The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to th…
▽ More
The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical "quantum evaporation" signal from $^4$He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype "HeRALD v0.1" detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. A key result of this work is the measurement of the quantum evaporation channel's gain of 0.15 $\pm$ 0.01, which will enable $^4$He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5 sigma, which would be sensitive to dark matter masses down to 220 MeV/c$^2$.
△ Less
Submitted 4 November, 2024; v1 submitted 21 July, 2023;
originally announced July 2023.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
Report of the Instrumentation Frontier Working Group for Snowmass 2021
Authors:
Phillip S. Barbeau,
Petra Merkel,
Jinlong Zhang,
Darin Acosta,
Anthony A. Affolder,
Artur Apresyan,
Marina Artuso,
Vallary Bhopatkar,
Stephen Butalla,
Gabriella A. Carini,
Thomas Cecil,
Amy Connolly,
C. Eric Dahl,
Allison Deiana,
Katherine Dunne,
Carlos O. Escobar,
Juan Estrada,
Farah Fahim,
James E. Fast,
Maurice Garcia-Sciveres,
Roxanne Guenette,
Michael T. Hedges,
Kent Irwin,
Albrecht Karle,
Wes Ketchum
, et al. (20 additional authors not shown)
Abstract:
Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technol…
▽ More
Detector instrumentation is at the heart of scientific discoveries. Cutting edge technologies enable US particle physics to play a leading role worldwide. This report summarizes the current status of instrumentation for High Energy Physics (HEP), the challenges and needs of future experiments and indicates high priority research areas. The Snowmass Instrumentation Frontier studies detector technologies and Research and Development (R&D) needed for future experiments in collider physics, neutrino physics, rare and precision physics and at the cosmic frontier. It is divided into more or less diagonal areas with some overlap among a few of them. We lay out five high-level key messages that are geared towards ensuring the health and competitiveness of the US detector instrumentation community, and thus the entire particle physics landscape.
△ Less
Submitted 3 November, 2022; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Report of the Topical Group on Quantum Sensors for Snowmass 2021
Authors:
Thomas Cecil,
Kent Irwin,
Reina Maruyama,
Matt Pyle,
Silvia Zorzetti
Abstract:
Quantum Sensors offer great potential for providing enhanced sensitivity in high energy physics experiments. In this report we provide a summary of key quantum sensors technologies - interferometers, optomechanics, and clocks; spin dependent sensors; superconducting sensors; and quantum calorimeters - highlighting existing experiments along with areas for development. We also provide a set of key…
▽ More
Quantum Sensors offer great potential for providing enhanced sensitivity in high energy physics experiments. In this report we provide a summary of key quantum sensors technologies - interferometers, optomechanics, and clocks; spin dependent sensors; superconducting sensors; and quantum calorimeters - highlighting existing experiments along with areas for development. We also provide a set of key messages intended to further advance the state of quantum sensors used for high energy physics specific applications.
△ Less
Submitted 20 September, 2022; v1 submitted 28 August, 2022;
originally announced August 2022.
-
A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning
Authors:
Robin Anthony-Petersen,
Andreas Biekert,
Raymond Bunker,
Clarence L. Chang,
Yen-Yung Chang,
Luke Chaplinsky,
Eleanor Fascione,
Caleb W. Fink,
Maurice Garcia-Sciveres,
Richard Germond,
Wei Guo,
Scott A. Hertel,
Ziqing Hong,
Noah Kurinsky,
Xinran Li,
Junsong Lin,
Marharyta Lisovenko,
Rupak Mahapatra,
Adam Mayer,
Daniel N. McKinsey,
Siddhant Mehrotra,
Nader Mirabolfathi,
Brian Neblosky,
William A. Page,
Pratyush K. Patel
, et al. (21 additional authors not shown)
Abstract:
The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show…
▽ More
The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.
△ Less
Submitted 14 August, 2024; v1 submitted 4 August, 2022;
originally announced August 2022.
-
The level-1 trigger for the SuperCDMS experiment at SNOLAB
Authors:
Jonathan S. Wilson,
Hanno Meyer zu Theenhausen,
Belina von Krosigk,
Elham Azadbakht,
Ray Bunker,
Jeter Hall,
Sten Hansen,
Bruce Hines,
Ben Loer,
Jamieson T. Olsen,
Scott M. Oser,
Richard Partridge,
Matthew Pyle,
Joel Sander,
Bruno Serfass,
David Toback,
Samuel L. Watkins,
Xuji Zhao
Abstract:
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filte…
▽ More
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, $σ_n$, and a 99.9% trigger efficiency for signal amplitudes of 1.1 $σ_n$ in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.
△ Less
Submitted 23 May, 2022; v1 submitted 27 April, 2022;
originally announced April 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Combining Deep Learning with Physics Based Features in Explosion-Earthquake Discrimination
Authors:
Qingkai Kong,
Ruijia Wang,
William R. Walter,
Moira Pyle,
Keith Koper,
Brandon Schmandt
Abstract:
This paper combines the power of deep-learning with the generalizability of physics-based features, to present an advanced method for seismic discrimination between earthquakes and explosions. The proposed method contains two branches: a deep learning branch operating directly on seismic waveforms or spectrograms, and a second branch operating on physics-based parametric features. These features a…
▽ More
This paper combines the power of deep-learning with the generalizability of physics-based features, to present an advanced method for seismic discrimination between earthquakes and explosions. The proposed method contains two branches: a deep learning branch operating directly on seismic waveforms or spectrograms, and a second branch operating on physics-based parametric features. These features are high-frequency P/S amplitude ratios and the difference between local magnitude (ML) and coda duration magnitude (MC). The combination achieves better generalization performance when applied to new regions than models that are developed solely with deep learning. We also examined which parts of the waveform data dominate deep learning decisions (i.e., via Grad-CAM). Such visualization provides a window into the black-box nature of the machine-learning models and offers new insight into how the deep learning derived models use data to make the decisions.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
A backing detector for order-keV neutrons
Authors:
A. Biekert,
L. Chaplinsky,
C. W. Fink,
M. Garcia-Sciveres,
W. C. Gillis,
W. Guo,
S. A. Hertel,
G. Heuermann,
X. Li,
J. Lin,
R. Mahapatra,
D. N. McKinsey,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
R. K. Romani,
A. Serafin,
R. J. Smith,
B. Suerfu,
V. Velan,
G. Wang,
Y. Wang,
S. L. Watkins
, et al. (1 additional authors not shown)
Abstract:
We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scatte…
▽ More
We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$ν$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of $\sim$25\% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of $\sim$17$~μ$s. The prototype was characterized using a \ce{^{252}Cf} neutron source and agreement with the simulation was observed within a few percent level.
△ Less
Submitted 9 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Scintillation yield from electronic and nuclear recoils in superfluid $^4$He
Authors:
SPICE/HeRALD Collaboration,
:,
A. Biekert,
C. Chang,
C. W. Fink,
M. Garcia-Sciveres,
E. C. Glazer,
W. Guo,
S. A. Hertel,
S. Kravitz,
J. Lin,
M. Lisovenko,
R. Mahapatra,
D. N. McKinsey,
J. S. Nguyen,
V. Novosad,
W. Page,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Pyle,
R. K. Romani,
A. S. Seilnacht,
A. Serafin,
R. J. Smith
, et al. (9 additional authors not shown)
Abstract:
Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~c…
▽ More
Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090 keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. We also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.
△ Less
Submitted 14 May, 2022; v1 submitted 4 August, 2021;
originally announced August 2021.
-
Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range
Authors:
R. Ren,
C. Bathurst,
Y. Y. Chang,
R. Chen,
C. W. Fink,
Z. Hong,
N. A. Kurinsky,
N. Mast,
N. Mishra,
V. Novati,
G. Spahn,
H. Meyer zu Theenhausen,
S. L. Watkins,
Z. Williams,
M. J. Wilson,
A. Zaytsev,
D. Bauer,
R. Bunker,
E. Figueroa-Feliciano,
M. Hollister,
L. Hsu,
P. Lukens,
R. Mahapatra,
N. Mirabolfathi,
B. Nebolsky
, et al. (5 additional authors not shown)
Abstract:
We present the design and characterization of a cryogenic phonon-sensitive 1-gram Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2)~eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100~V bias. With a continuous-readout data…
▽ More
We present the design and characterization of a cryogenic phonon-sensitive 1-gram Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2)~eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100~V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2~eV threshold with a trigger rate of the order of 20~Hz. The detector's energy scale is calibrated up to 120~keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.
△ Less
Submitted 20 May, 2021; v1 submitted 22 December, 2020;
originally announced December 2020.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Performance of a Large Area Photon Detector For Rare Event Search Applications
Authors:
CPD Collaboration,
C. W. Fink,
S. L. Watkins,
T. Aramaki,
P. L. Brink,
J. Camilleri,
X. Defay,
S. Ganjam,
Yu. G. Kolomensky,
R. Mahapatra,
N. Mirabolfathi,
W. A. Page,
R. Partridge,
M. Platt,
M. Pyle,
B. Sadoulet,
B. Serfass,
S. Zuber
Abstract:
We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-…
▽ More
We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors (QETs) with superconducting critical temperature $T_c=41.5$ $\mathrm{mK}$ to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated with a collimated $^{55}$Fe X-ray source incident on the center of the detector. The noise equivalent power is measured to be $1\times 10^{-17}$ $\mathrm{W}/\sqrt{\mathrm{Hz}}$ in a bandwidth of $2.7$ $\mathrm{kHz}$. The baseline energy resolution is measured to be $σ_E = 3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.23}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$ (RMS). The detector also has an expected timing resolution of $σ_t = 2.3$ $μ\mathrm{s}$ for $5$ $σ_E$ events.
△ Less
Submitted 11 January, 2021; v1 submitted 29 September, 2020;
originally announced September 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors
Authors:
C. W. Fink,
S. L. Watkins,
T. Aramaki,
P. L. Brink,
S. Ganjam,
B. A. Hines,
M. E. Huber,
N. A. Kurinsky,
R. Mahapatra,
N. Mirabolfathi,
W. A. Page,
R. Partridge,
M. Platt,
M. Pyle,
B. Sadoulet,
B. Serfass,
S. Zuber
Abstract:
In this letter, we present the performance of a $100~μ\mathrm{m}\times 400~μ\mathrm{m} \times 40~\mathrm{nm}$ tungsten (W) Transition-Edge Sensor (TES) with a critical temperature of 40 mK. This device has a measured noise equivalent power (NEP) of $1.5\times 10^{-18}\ \mathrm{W}/\sqrt{\mathrm{Hz}}$, in a bandwidth of $2.6$ kHz, indicating a resolution for Dirac delta energy depositions of…
▽ More
In this letter, we present the performance of a $100~μ\mathrm{m}\times 400~μ\mathrm{m} \times 40~\mathrm{nm}$ tungsten (W) Transition-Edge Sensor (TES) with a critical temperature of 40 mK. This device has a measured noise equivalent power (NEP) of $1.5\times 10^{-18}\ \mathrm{W}/\sqrt{\mathrm{Hz}}$, in a bandwidth of $2.6$ kHz, indicating a resolution for Dirac delta energy depositions of $40\pm 5~\mathrm{meV}$ (rms). The performance demonstrated by this device is a critical step towards developing a $\mathcal{O}(100)~\mathrm{meV}$ threshold athermal phonon detectors for low-mass dark matter searches.
△ Less
Submitted 10 August, 2020; v1 submitted 21 April, 2020;
originally announced April 2020.
-
Modeling of Impact Ionization and Charge Trapping in SuperCDMS HVeV Detectors
Authors:
F. Ponce,
W. Page,
P. L. Brink,
B. Cabrera,
M. Cherry,
C. Fink,
N. Kurinsky,
R. Partridge,
M. Pyle,
B. Sadoulet,
B. Serfass,
C. Stanford,
S. L. Watkins,
S. Yellin,
B. A. Young
Abstract:
A model for charge trapping and impact ionization, and an experiment to measure these parameters is presented for the SuperCDMS HVeV detector. A procedure to isolate and quantify the main sources of noise (bulk and surface charge leakage) in the measurements is also describe. This sets the stage to precisely measure the charge trapping and impact ionization probabilities in order to incorporate th…
▽ More
A model for charge trapping and impact ionization, and an experiment to measure these parameters is presented for the SuperCDMS HVeV detector. A procedure to isolate and quantify the main sources of noise (bulk and surface charge leakage) in the measurements is also describe. This sets the stage to precisely measure the charge trapping and impact ionization probabilities in order to incorporate this model into future dark matter searches.
△ Less
Submitted 24 December, 2019;
originally announced December 2019.
-
Constraints on dark photons and axion-like particles from SuperCDMS Soudan
Authors:
SuperCDMS Collaboration,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
H. Coombes,
J. Corbett
, et al. (82 additional authors not shown)
Abstract:
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 5…
▽ More
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.
△ Less
Submitted 18 January, 2021; v1 submitted 26 November, 2019;
originally announced November 2019.
-
Measuring the Impact Ionization and Charge Trapping Probabilities in SuperCDMS HVeV Phonon Sensing Detectors
Authors:
F. Ponce,
W. Page,
P. L. Brink,
B. Cabrera,
M. Cherry,
C. Fink,
N. Kurinsky,
R. Partridge,
M. Pyle,
B. Sadoulet,
B. Serfass,
C. Stanford,
S. L. Watkins,
S. Yellin,
B. A. Young
Abstract:
A 0.93 gram $1{\times}1{\times}0.4$ cm$^3$ SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. The detector's response under a variety of specific operating conditions was used to study the detector leakage current, charge trapping and impact ionization in the high-purity Si substrate. T…
▽ More
A 0.93 gram $1{\times}1{\times}0.4$ cm$^3$ SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. The detector's response under a variety of specific operating conditions was used to study the detector leakage current, charge trapping and impact ionization in the high-purity Si substrate. The measured probabilities for a charge carrier in the detector to undergo charge trapping (0.713 $\pm$ 0.093%) or cause impact ionization (1.576 $\pm$ 0.110%) were found to be nearly independent of bias polarity and charge-carrier type (electron or hole) for substrate biases of $\pm$ 140 V.
△ Less
Submitted 1 December, 2019; v1 submitted 4 October, 2019;
originally announced October 2019.
-
New Technologies for Discovery
Authors:
Z. Ahmed,
A. Apresyan,
M. Artuso,
P. Barry,
E. Bielejec,
F. Blaszczyk,
T. Bose,
D. Braga,
S. A. Charlebois,
A. Chatterjee,
A. Chavarria,
H. -M. Cho,
S. Dalla Torre,
M. Demarteau,
D. Denisov,
M. Diefenthaler,
A. Dragone,
F. Fahim,
C. Gee,
S. Habib,
G. Haller,
J. Hogan,
B. J. P. Jones,
M. Garcia-Sciveres,
G. Giacomini
, et al. (58 additional authors not shown)
Abstract:
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by hi…
▽ More
For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.
△ Less
Submitted 10 August, 2019; v1 submitted 31 July, 2019;
originally announced August 2019.
-
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
F. De Brienne,
T. Doughty
, et al. (78 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
△ Less
Submitted 2 January, 2021; v1 submitted 27 August, 2018;
originally announced August 2018.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Authors:
Robert Agnese,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Elham Azadbakht,
William Baker,
Samir Banik,
D'Ann Barker,
Dan Bauer,
Thomas Binder,
Michael Bowles,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Jodi Cooley,
Brett Cornell,
Priscilla Cushman,
Philippe Di Stefano,
Todd Doughty,
Eleanor Fascione,
Tali Figueroa
, et al. (72 additional authors not shown)
Abstract:
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which w…
▽ More
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
△ Less
Submitted 16 April, 2019; v1 submitted 24 May, 2018;
originally announced May 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Thermal detection of single e-h pairs in a biased silicon crystal detector
Authors:
R. K. Romani,
P. L. Brink,
B. Cabrera,
M. Cherry,
T. Howarth,
N. Kurinsky,
R. A. Moffatt,
R. Partridge,
F. Ponce,
M. Pyle,
A. Tomada,
S. Yellin,
J. J. Yen,
B. A. Young
Abstract:
We demonstrate that individual electron-hole pairs are resolved in a 1 cm$^2$ by 4 mm thick silicon crystal (0.93 g) operated at $\sim$35 mK. One side of the detector is patterned with two quasiparticle-trap-assisted electro-thermal-feedback transition edge sensor (QET) arrays held near ground potential. The other side contains a bias grid with 20\% coverage. Bias potentials up to $\pm$ 160 V were…
▽ More
We demonstrate that individual electron-hole pairs are resolved in a 1 cm$^2$ by 4 mm thick silicon crystal (0.93 g) operated at $\sim$35 mK. One side of the detector is patterned with two quasiparticle-trap-assisted electro-thermal-feedback transition edge sensor (QET) arrays held near ground potential. The other side contains a bias grid with 20\% coverage. Bias potentials up to $\pm$ 160 V were used in the work reported here. A fiber optic provides 650~nm (1.9 eV) photons that each produce an electron-hole ($e^{-} h^{+}$) pair in the crystal near the grid. The energy of the drifting charges is measured with a phonon sensor noise $σ$ $\sim$0.09 $e^{-} h^{+}$ pair. The observed charge quantization is nearly identical for $h^+$'s or $e^-$'s transported across the crystal.
△ Less
Submitted 15 December, 2017; v1 submitted 25 October, 2017;
originally announced October 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
SuperCDMS SNOLAB Low-Mass Detectors: Ultra-Sensitive Phonon Calorimeters for a Sub-GeV Dark Matter Search
Authors:
Noah Kurinsky,
Paul Brink,
Richard Partridge,
Blas Cabrera,
Matt Pyle
Abstract:
We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering events in high-purity Ge and Si crystals. In this paper we discuss some of the studies and technological improvements which have allowed us to design such a sensiti…
▽ More
We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering events in high-purity Ge and Si crystals. In this paper we discuss some of the studies and technological improvements which have allowed us to design such a sensitive detector, including advances in phonon sensor design and detector simulation. With this design we expect to achieve better than 10 eV (5 eV) phonon energy resolution in our Ge (Si) detectors, and recoil energy resolution below 1eV by exploiting Luke-Neganov phonon generation of charges accelerated in high fields.
△ Less
Submitted 12 November, 2016;
originally announced November 2016.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
WIMP-Search Results from the Second CDMSlite Run
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aramaki,
M. Asai,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (65 additional authors not shown)
Abstract:
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization…
▽ More
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
△ Less
Submitted 9 March, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Optimized Designs for Very Low Temperature Massive Calorimeters
Authors:
Matt Pyle,
Enectali Figueroa-Feliciano,
Bernard Sadoulet
Abstract:
The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study of several calorimetric detectors suggests that a mismatch between the sensor and signal bandwidths is the primary reason for suppressed sensitivity. With this u…
▽ More
The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters (utilizing TES and NTD sensor technologies) is $>2$ orders of magnitude worse than theoretical predictions. A detailed study of several calorimetric detectors suggests that a mismatch between the sensor and signal bandwidths is the primary reason for suppressed sensitivity. With this understanding, we propose a detector design in which a thin-film Au pad is directly deposited onto a massive absorber that is then thermally linked to a separately fabricated TES chip via an Au wirebond, providing large electron-phonon coupling (i.e. high signal bandwidth), ease of fabrication, and cosmogenic background suppression. Interestingly, this design strategy is fully compatible with the use of hygroscopic crystals (NaI) as absorbers. An 80-mm diameter Si light detector based upon these design principles, with potential use in both dark matter and neutrinoless double beta decay, has an estimated baseline energy resolution of 0.35 eV, 20$\times$ better than currently achievable. A 1.75 kg ZnMoO$_{4}$ large-mass calorimeter would have a 3.5 eV baseline resolution, 1000$\times$ better than currently achieved with NTDs with an estimated position dependence $\frac{ΔE}{E}$ of 6$\times$10$^{-4}$. Such minimal position dependence is made possible by forcing the sensor bandwidth to be much smaller than the signal bandwidth. Further, intrinsic event timing resolution is estimated to be $\sim$170 $μ$s for 3 MeV recoils in the phonon detector, satisfying the event-rate requirements of large $Q_{ββ}$ next-generation neutrinoless double beta decay experiments. Quiescent bias power for both of these designs is found to be significantly larger than parasitic power loads achieved in the SPICA/SAFARI infrared bolometers.
△ Less
Submitted 12 March, 2015; v1 submitted 3 March, 2015;
originally announced March 2015.
-
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban
, et al. (62 additional authors not shown)
Abstract:
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background…
▽ More
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (60 additional authors not shown)
Abstract:
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six…
▽ More
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
△ Less
Submitted 3 February, 2015; v1 submitted 10 September, 2014;
originally announced September 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Sensor Compendium
Authors:
M. Artuso,
M. Battaglia,
G. Bolla,
D. Bortoletto,
B. Cabrera,
J. E. Carlstrom,
C. L. Chang,
W. Cooper,
C. Da Via,
M. Demarteau,
J. Fast,
H. Frisch,
M. Garcia-Sciveres,
S. Golwala,
C. Haber,
J. Hall,
E. Hoppe,
K. D. Irwin,
H. Kagan,
C. Kenney,
A. T. Lee,
D. Lynn,
J. Orrell,
M. Pyle,
R. Rusack
, et al. (7 additional authors not shown)
Abstract:
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, e…
▽ More
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges
△ Less
Submitted 25 October, 2013; v1 submitted 18 October, 2013;
originally announced October 2013.
-
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (55 additional authors not shown)
Abstract:
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll…
▽ More
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
△ Less
Submitted 20 December, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
E. Do Couto E Silva,
T. Doughty,
L. Esteban,
S. Fallows,
E. Figueroa-Feliciano
, et al. (66 additional authors not shown)
Abstract:
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste…
▽ More
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
△ Less
Submitted 4 October, 2013; v1 submitted 10 May, 2013;
originally announced May 2013.
-
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
E. Do Couto E Silva
, et al. (66 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206P…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
△ Less
Submitted 11 October, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Phonon Pulse Shape Discrimination in SuperCDMS Soudan
Authors:
S. A. Hertel,
M. Pyle
Abstract:
SuperCDMS is the next phase of the Cryogenic Dark Matter Search experiment, which measures both phonon and charge signals generated by particle recoils within a germanium target mass. Charge signals are employed both in the definition of a fiducial volume and in the rejection of electron recoil background events. Alternatively, phonons generated by the charge carriers can also be used for the same…
▽ More
SuperCDMS is the next phase of the Cryogenic Dark Matter Search experiment, which measures both phonon and charge signals generated by particle recoils within a germanium target mass. Charge signals are employed both in the definition of a fiducial volume and in the rejection of electron recoil background events. Alternatively, phonons generated by the charge carriers can also be used for the same two goals. This paper describes preliminary efforts to observe and quantify these contributions to the phonon signal and then use them to reject background events. A simple analysis using only one pulse shape parameter shows bulk electron recoil vs. bulk nuclear recoil discrimination to the level of 1:10^3 (limited by the statistics of the data), with little degradation in discrimination ability down to at least 7 keV recoil energy. Such phonon-only discrimination can provide a useful cross-check to the standard discrimination methods, and it also points towards the potential of a device optimized for a phonon-only measurement.
△ Less
Submitted 20 September, 2011;
originally announced September 2011.
-
Modeling phase-separated transition-edge sensors in SuperCDMS detectors
Authors:
A. J. Anderson,
S. W. Leman,
T. Doughty,
E. Figueroa-Feliciano,
K. A. McCarthy,
M. Pyle,
B. A. Young
Abstract:
The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters to data, which reproduces superconducting-to-normal phase separation within a TES. This tuning provides insight into the behavior of the TESs, allows us to stud…
▽ More
The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters to data, which reproduces superconducting-to-normal phase separation within a TES. This tuning provides insight into the behavior of the TESs, allows us to study the phase-separation length to optimize our detector design, and is integrated into a more complete simulation of the phonon and charge physics of SuperCDMS detectors.
△ Less
Submitted 23 September, 2011; v1 submitted 16 September, 2011;
originally announced September 2011.
-
Simulations of Noise in Phase-Separated Transition-Edge Sensors for SuperCDMS
Authors:
A. J. Anderson,
S. W. Leman,
M. Pyle,
E. Figueroa-Feliciano,
K. McCarthy,
T. Doughty,
M. Cherry,
B. Young
Abstract:
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations are valuable for optimizing the critical temperature and TES length of future SuperCDMS detec…
▽ More
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations are valuable for optimizing the critical temperature and TES length of future SuperCDMS detectors.
△ Less
Submitted 6 September, 2011;
originally announced September 2011.
-
Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with low Transition-Edge-Sensor Transition Temperature
Authors:
S. W. Leman,
K. A. McCarthy,
P. L. Brink,
B. Cabrera,
M. Cherry,
E. Do Couto E Silva,
E. Figueroa-Feliciano,
P. Kim,
N. Mirabolfathi,
M. Pyle,
R. Resch,
B. Sadoulet,
B. Serfass,
K. M. Sundqvist,
A. Tomada,
B. A. Young
Abstract:
We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the g…
▽ More
We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels. The phonon energy is then parsed into TES based phonon readout channels and input into a TES simulator.
△ Less
Submitted 6 September, 2011;
originally announced September 2011.