-
Functional Assessment of Cerebral Capillaries using Single Capillary Reporters in Ultrasound Localization Microscopy
Authors:
Stephen A Lee,
Alexis Leconte,
Alice Wu,
Joshua Kinugasa,
Jonathan Poree,
Andreas Linninger,
Jean Provost
Abstract:
The brain's microvascular cerebral capillary network plays a vital role in maintaining neuronal health, yet capillary dynamics are still not well understood due to limitations in existing imaging techniques. Here, we present Single Capillary Reporters (SCaRe) for transcranial Ultrasound Localization Microscopy (ULM), a novel approach enabling non-invasive, whole-brain mapping of single capillaries…
▽ More
The brain's microvascular cerebral capillary network plays a vital role in maintaining neuronal health, yet capillary dynamics are still not well understood due to limitations in existing imaging techniques. Here, we present Single Capillary Reporters (SCaRe) for transcranial Ultrasound Localization Microscopy (ULM), a novel approach enabling non-invasive, whole-brain mapping of single capillaries and estimates of their transit-time as a neurovascular biomarker. We accomplish this first through computational Monte Carlo and ultrasound simulations of microbubbles flowing through a fully-connected capillary network. We unveil distinct capillary flow behaviors which informs methodological changes to ULM acquisitions to better capture capillaries in vivo. Subsequently, applying SCaRe-ULM in vivo, we achieve unprecedented visualization of single capillary tracks across brain regions, analysis of layer-specific capillary heterogeneous transit times (CHT), and characterization of whole microbubble trajectories from arterioles to venules. Lastly, we evaluate capillary biomarkers using injected lipopolysaccharide to induce systemic neuroinflammation and track the increase in SCaRe-ULM CHT, demonstrating the capability to detect subtle capillary functional changes. SCaRe-ULM represents a significant advance in studying microvascular dynamics, offering novel avenues for investigating capillary patterns in neurological disorders and potential diagnostic applications.
△ Less
Submitted 10 July, 2024; v1 submitted 10 July, 2024;
originally announced July 2024.
-
3D transcranial Dynamic Ultrasound Localization Microscopy in the mouse brain using a Row-Column Array
Authors:
Alice Wu,
Jonathan Porée,
Gerardo Ramos-Palacios,
Chloé Bourquin,
Nin Ghigo,
Alexis Leconte,
Paul Xing,
Abbas F. Sadikot,
Michaël Chassé,
Jean Provost
Abstract:
The role of brain hemodynamics in neurodegenerative diseases cannot be fully assessed using existing imaging technologies. Recently, 2D Dynamic Ultrasound Localization Microscopy (DULM) has allowed for the quantitative mapping of the pulsatile flow at sub-wavelength resolution. However, to obtain accurate velocity estimates, 3D imaging is more adapted, especially for complex vascularized organs li…
▽ More
The role of brain hemodynamics in neurodegenerative diseases cannot be fully assessed using existing imaging technologies. Recently, 2D Dynamic Ultrasound Localization Microscopy (DULM) has allowed for the quantitative mapping of the pulsatile flow at sub-wavelength resolution. However, to obtain accurate velocity estimates, 3D imaging is more adapted, especially for complex vascularized organs like the brain. 3D+t DULM is achievable using matrix array probes, but suffers from limitations in terms of cost, device complexity associated with the high channel count, and operating frequencies. Alternatively, Row Column Arrays (RCA) can reduce the number of elements while maintaining a large field of view and high frame rate. Herein, we demonstrate the feasibility of performing 3D+t blood flow measurements in the mouse brain using an RCA and a DULM sequence with a high spatiotemporal resolution. Transcranial images of anesthetized mice (n=7) were acquired at a volume rate of 750 Hz using 42 tilted plane waves. After microbubbles localization and tracking, super-resolved dynamic density and velocity maps of the 3D brain vascular network were obtained. Cortical vessels were segmented and pulsatility in the arteries was significantly higher than in veins for all mice, in accordance with the literature. Our results demonstrate the feasibility and reproducibility of achieving high spatiotemporal resolution volumes of the mouse brain vasculature with DULM using a RCA.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Inverse Problem Approach to Aberration Correction for in vivo Transcranial Imaging Based on a Sparse Representation of Contrast-enhanced Ultrasound Data
Authors:
Paul Xing,
Antoine Malescot,
Eric Martineau,
Ravi Rungta,
Jean Provost
Abstract:
Transcranial ultrasound imaging is currently limited by attenuation and aberration induced by the skull. First used in contrast-enhanced ultrasound (CEUS), highly echoic microbubbles allowed for the development of novel imaging modalities such as ultrasound localization microscopy (ULM). Herein, we develop an inverse problem approach to aberration correction (IPAC) that leverages the sparsity of m…
▽ More
Transcranial ultrasound imaging is currently limited by attenuation and aberration induced by the skull. First used in contrast-enhanced ultrasound (CEUS), highly echoic microbubbles allowed for the development of novel imaging modalities such as ultrasound localization microscopy (ULM). Herein, we develop an inverse problem approach to aberration correction (IPAC) that leverages the sparsity of microbubble signals. We propose to use the \textit{a priori} knowledge of the medium based upon microbubble localization and wave propagation to build a forward model to link the measured signals directly to the aberration function. A standard least-squares inversion is then used to retrieve the aberration function. We first validated IPAC on simulated data of a vascular network using plane wave as well as divergent wave emissions. We then evaluated the reproducibility of IPAC \textit{in vivo} in 5 mouse brains. We showed that aberration correction improved the contrast of CEUS images by 4.6 dB. For ULM images, IPAC yielded sharper vessels, reduced vessel duplications, and improved the resolution from 21.1 $μ$m to 18.3 $μ$m. Aberration correction also improved hemodynamic quantification for velocity magnitude and flow direction.
△ Less
Submitted 26 March, 2025; v1 submitted 18 January, 2024;
originally announced January 2024.
-
A unified framework combining coherent compounding, harmonic imaging and angular coherence for simultaneous high-quality B-mode and tissue Doppler in ultrafast echocardiography
Authors:
Michael Mougharbel,
Jonathan Porée,
Stephen A. Lee,
Paul Xing,
Alice Wu,
Jean-Claude Tardif,
Jean Provost
Abstract:
Various methods have been proposed to enhance image quality in ultrafast ultrasound. Coherent compounding can improve image quality using multiple steered diverging transmits when motion occurring between transmits is corrected for. Harmonic imaging, a standard technique in conventional focused echocardiography, has been adapted for ultrafast imaging, reducing clutter. Coherence-based approaches h…
▽ More
Various methods have been proposed to enhance image quality in ultrafast ultrasound. Coherent compounding can improve image quality using multiple steered diverging transmits when motion occurring between transmits is corrected for. Harmonic imaging, a standard technique in conventional focused echocardiography, has been adapted for ultrafast imaging, reducing clutter. Coherence-based approaches have also been shown to increase contrast in clinical settings by enhancing signals from coherent echoes and reducing clutter. Herein, we introduce a simple, unified framework that combines motion-correction, harmonic imaging, and angular-coherence, showing for the first time that their benefits can be combined in real-time. Validation was conducted through in vitro testing on a spinning disk model and in vivo on 4 volunteers. In vitro results confirmed the unified framework capability to achieve high contrast in large-motion contexts up to 17 cm/s. In vivo testing highlighted proficiency in generating images of high quality during low and high tissue velocity phases of the cardiac cycle. Specifically, during ventricular filling, the unified framework increased the gCNR from 0.47 to 0.87 when compared against coherent compounding.
△ Less
Submitted 4 December, 2023;
originally announced December 2023.
-
Dynamic Imaging using any Ultrasound Localization Microscopy Dataset
Authors:
Nin Ghigo,
Gerardo Ramos-Palacios,
Chloé Bourquin,
Paul Xing,
Alice Wu,
Nelson Cortés,
Hugo Ladret,
Lamyae Ikan,
Christian Casanova,
Jonathan Porée,
Abbas Sadikot,
Jean Provost
Abstract:
Ultrasound Localization Microscopy (ULM) relies on the injection of microbubbles (MBs) to obtain highly resolved density maps of blood circulation in vivo, with a resolution that can reach 10 μm ~ λ/10 in the rodent brain. Static mean velocity maps can be extracted but are intrinsically biased by potential significant changes in the number of MBs detected during the cardiac cycle. Dynamic ULM (DUL…
▽ More
Ultrasound Localization Microscopy (ULM) relies on the injection of microbubbles (MBs) to obtain highly resolved density maps of blood circulation in vivo, with a resolution that can reach 10 μm ~ λ/10 in the rodent brain. Static mean velocity maps can be extracted but are intrinsically biased by potential significant changes in the number of MBs detected during the cardiac cycle. Dynamic ULM (DULM) is a technique developed for non-invasive pulsatility measurements in the brain of rodents, leading to temporally resolved velocity and density cine-loops. It was previously based on external triggers such as the electrocardiogram (ECG), limiting its use to datasets acquired specifically for DULM applications while also increasing the required acquisition time. This study presents a new motion matching method using tissue Doppler that eliminates the need for ECG-gating in DULM experiments. DULM can now be performed on any ULM datasets, recovering pertinent temporal information, and improving the robustness of the mean velocity estimates.
△ Less
Submitted 1 November, 2023;
originally announced November 2023.
-
Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM)
Authors:
Erwan Hardy,
Jonathan Poree,
Hatim Belgharbi,
Chloe Bourquin,
Frederic Lesage,
Jean Provost
Abstract:
Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limi…
▽ More
Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limiting factors of this technology. Herein, we introduce a novel reconstruction framework to decrease this quantity of data to be acquired and the complexity of the required hardware by randomly subsampling the channels of a linear probe. Method performance evaluation as well as parameters optimization were conducted in silico using the SIMUS simulation software in an anatomically realistic phantom and then compared to in vivo acquisitions in a rat brain after craniotomy. Results show that reducing the number of active elements deteriorates the signal-to-noise ratio and could lead to false microbubbles detections but has limited effect on localization accuracy. In simulation, the false positive rate on microbubble detection deteriorates from 3.7% for 128 channels in receive and 7 steered angles to 11% for 16 channels and 7 angles. The average localization accuracy ranges from 10.6 um and 9.93 um for 16 channels/3 angles and 128 channels/13 angles respectively. These results suggest that a compromise can be found between the number of channels and the quality of the reconstructed vascular network and demonstrate feasibility of performing ULM with a reduced number of channels in receive, paving the way for low-cost devices enabling high-resolution vascular mapping.
△ Less
Submitted 19 October, 2023;
originally announced October 2023.
-
Equivalent Time Active Cavitation Imaging
Authors:
Simon Blais,
Jonathan Poree,
Gerardo Ramos-Palacios,
Samuel Desmarais,
Vincent Perrot,
Abbas Sadikot,
Jean Provost
Abstract:
The development of neurologically active drugs faces a challenge in treating brain diseases due to the blood-brain barrier's impermeability. High-intensity focused ultrasound can open the barrier in a targeted manner, expanding treatment options. However, this procedure risks brain damage and off-target effects without proper monitoring. Current monitoring methods have limitations. We present Equi…
▽ More
The development of neurologically active drugs faces a challenge in treating brain diseases due to the blood-brain barrier's impermeability. High-intensity focused ultrasound can open the barrier in a targeted manner, expanding treatment options. However, this procedure risks brain damage and off-target effects without proper monitoring. Current monitoring methods have limitations. We present Equivalent Time Active Cavitation Imaging, a novel ultrasound modality that characterizes the ultrasound pressure field during treatment. This system utilizes a unique plane wave sequence and an algorithm to filter the microbubble signal for pressure field mapping. We conducted pressure measurements in vitro for comparison with hydrophones and in vivo during blood-brain barrier opening in mice. Our modality successfully spatiotemporally characterizes the pressure field with an active imaging setup, demonstrating good correlation with hydrophone measurements. Experimental in vivo results are promising, establishing the feasibility of this monitoring method. In conclusion, this proof of concept represents a significant step toward a new ultrasound modality for monitoring blood-brain barrier opening using focused ultrasound. This approach offers a safer and more precise monitoring method, opening new possibilities for treating brain diseases.
△ Less
Submitted 19 October, 2023;
originally announced October 2023.
-
Ergodic encoding for single-element ultrasound imaging in vivo
Authors:
Olivier Caron-Grenier,
Jonathan Poree,
Vincent Perrot,
Gerardo Ramos-Palacio,
Abbas F Sadikot,
Jean Provost
Abstract:
Conventional ultrasound imaging relies on the computation of geometric time delay from multiple sensors to detect the position of a scatterer. In this paper, we present Ergodic Relay Ultrasound Imaging (ERUI), a method that utilizes an ergodic cavity down to a single ultrasonic sensor for ultrasound imaging. With the proposed method, the ergodic cavity creates a unique temporal signature that enco…
▽ More
Conventional ultrasound imaging relies on the computation of geometric time delay from multiple sensors to detect the position of a scatterer. In this paper, we present Ergodic Relay Ultrasound Imaging (ERUI), a method that utilizes an ergodic cavity down to a single ultrasonic sensor for ultrasound imaging. With the proposed method, the ergodic cavity creates a unique temporal signature that encodes the position of a scatterer. When compared to standard approaches, ERUI enables the generation of images of comparable quality while utilizing fewer detector elements. Our results suggest that ERUI has the potential to achieve image resolution similar to that of traditional imaging techniques, shifting the complexity from hardware to sofware. The demonstrated feasibility offers a promising path towards ultrasound probes with reduced costs and complexity for more portable scanning devices.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
Equivalent-Time-Active-Cavitation-Imaging Enables Vascular-Resolution Blood-Brain-Barrier-Opening-Therapy Planning
Authors:
Samuel Desmarais,
Gerardo Ramos-Palacios,
Jonathan Poree,
Stephen A. Lee,
Alexis Leconte,
Abbas F. Sadikot,
Jean Provost
Abstract:
Linking cavitation and anatomy was found to be important for predictable outcomes in Focused-Ultrasound Blood-Brain-Barrier-Opening and requires high resolution cavitation mapping. However, cavitation mapping techniques for planning and monitoring of therapeutic procedures either 1) do not leverage the full resolution capabilities of ultrasound imaging or 2) place strong constraints on the length…
▽ More
Linking cavitation and anatomy was found to be important for predictable outcomes in Focused-Ultrasound Blood-Brain-Barrier-Opening and requires high resolution cavitation mapping. However, cavitation mapping techniques for planning and monitoring of therapeutic procedures either 1) do not leverage the full resolution capabilities of ultrasound imaging or 2) place strong constraints on the length of the therapeutic pulse. This study aimed to develop a high-resolution technique that could resolve vascular anatomy in the cavitation map. Herein, we develop BP-ETACI, derived from bandpass sampling and dual-frequency contrast imaging at 12.5 MHz to produce cavitation maps prior and during blood-brain barrier opening with long therapeutic bursts using a 1.5-MHz focused transducer in the brain of C57BL/6 mice. The BP-ETACI cavitation maps were found to correlate with the vascular anatomy in ultrasound localization microscopy vascular maps and in histological sections. Cavitation maps produced from non-blood-brain-barrier disrupting doses showed the same cavitation-bearing vasculature as maps produced over entire blood-brain-barrier opening procedures, allowing use for 1) monitoring FUS-BBBO, but also for 2) therapy planning and target verification. BP-ETACI is versatile, created high resolution cavitation maps in the mouse brain and is easily translatable to existing FUS-BBBO experiments. As such, it provides a means to further study cavitation phenomena in FUS-BBBO.
△ Less
Submitted 7 August, 2023;
originally announced August 2023.
-
A Tracking prior to Localization workflow for Ultrasound Localization Microscopy
Authors:
Alexis Leconte,
Jonathan Porée,
Brice Rauby,
Alice Wu,
Nin Ghigo,
Paul Xing,
Chloé Bourquin,
Gerardo Ramos-Palacios,
Abbas F. Sadikot,
Jean Provost
Abstract:
Ultrasound Localization Microscopy (ULM) has proven effective in resolving microvascular structures and local mean velocities at sub-diffraction-limited scales, offering high-resolution imaging capabilities. Dynamic ULM (DULM) enables the creation of angiography or velocity movies throughout cardiac cycles. Currently, these techniques rely on a Localization-and-Tracking (LAT) workflow consisting i…
▽ More
Ultrasound Localization Microscopy (ULM) has proven effective in resolving microvascular structures and local mean velocities at sub-diffraction-limited scales, offering high-resolution imaging capabilities. Dynamic ULM (DULM) enables the creation of angiography or velocity movies throughout cardiac cycles. Currently, these techniques rely on a Localization-and-Tracking (LAT) workflow consisting in detecting microbubbles (MB) in the frames before pairing them to generate tracks. While conventional LAT methods perform well at low concentrations, they suffer from longer acquisition times and degraded localization and tracking accuracy at higher concentrations, leading to biased angiogram reconstruction and velocity estimation. In this study, we propose a novel approach to address these challenges by reversing the current workflow. The proposed method, Tracking-and-Localization (TAL), relies on first tracking the MB and then performing localization. Through comprehensive benchmarking using both in silico and in vivo experiments and employing various metrics to quantify ULM angiography and velocity maps, we demonstrate that the TAL method consistently outperforms the reference LAT workflow. Moreover, when applied to DULM, TAL successfully extracts velocity variations along the cardiac cycle with improved repeatability. The findings of this work highlight the effectiveness of the TAL approach in overcoming the limitations of conventional LAT methods, providing enhanced ULM angiography and velocity imaging.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Ultrafast Cardiac Imaging Using Deep Learning For Speckle-Tracking Echocardiography
Authors:
Jingfeng Lu,
Fabien Millioz,
François Varray,
Jonathan Porée,
Jean Provost,
Olivier Bernard,
Damien Garcia,
Denis Friboulet
Abstract:
High-quality ultrafast ultrasound imaging is based on coherent compounding from multiple transmissions of plane waves (PW) or diverging waves (DW). However, compounding results in reduced frame rate, as well as destructive interferences from high-velocity tissue motion if motion compensation (MoCo) is not considered. While many studies have recently shown the interest of deep learning for the reco…
▽ More
High-quality ultrafast ultrasound imaging is based on coherent compounding from multiple transmissions of plane waves (PW) or diverging waves (DW). However, compounding results in reduced frame rate, as well as destructive interferences from high-velocity tissue motion if motion compensation (MoCo) is not considered. While many studies have recently shown the interest of deep learning for the reconstruction of high-quality static images from PW or DW, its ability to achieve such performance while maintaining the capability of tracking cardiac motion has yet to be assessed. In this paper, we addressed such issue by deploying a complex-weighted convolutional neural network (CNN) for image reconstruction and a state-of-the-art speckle tracking method. The evaluation of this approach was first performed by designing an adapted simulation framework, which provides specific reference data, i.e. high quality, motion artifact-free cardiac images. The obtained results showed that, while using only three DWs as input, the CNN-based approach yielded an image quality and a motion accuracy equivalent to those obtained by compounding 31 DWs free of motion artifacts. The performance was then further evaluated on non-simulated, experimental in vitro data, using a spinning disk phantom. This experiment demonstrated that our approach yielded high-quality image reconstruction and motion estimation, under a large range of velocities and outperforms a state-of-the-art MoCo-based approach at high velocities. Our method was finally assessed on in vivo datasets and showed consistent improvement in image quality and motion estimation compared to standard compounding. This demonstrates the feasibility and effectiveness of deep learning reconstruction for ultrafast speckle-tracking echocardiography.
△ Less
Submitted 28 July, 2024; v1 submitted 25 June, 2023;
originally announced June 2023.
-
Imaging the dynamics of cardiac fiber orientation in vivo using 3D Ultrasound Backscatter Tensor Imaging
Authors:
Clement Papadacci,
Victor Finel,
Jean Provost,
Olivier Villemain,
Patrick Bruneval,
Jean-Luc Gennisson,
Mickael Tanter,
Mathias Fink,
Mathieu Pernot
Abstract:
The assessment of myocardial fiber disarray is of major interest for the study of the progression of myocardial disease. However, time-resolved imaging of the myocardial structure remains unavailable in clinical practice. In this study, we introduce 3D Backscatter Tensor Imaging (3D-BTI), an entirely novel ultrasound-based imaging technique that can map the myocardial fibers orientation and its dy…
▽ More
The assessment of myocardial fiber disarray is of major interest for the study of the progression of myocardial disease. However, time-resolved imaging of the myocardial structure remains unavailable in clinical practice. In this study, we introduce 3D Backscatter Tensor Imaging (3D-BTI), an entirely novel ultrasound-based imaging technique that can map the myocardial fibers orientation and its dynamics with a temporal resolution of 10 ms during a single cardiac cycle, non-invasively and in vivo in entire volumes. 3D-BTI is based on ultrafast volumetric ultrasound acquisitions, which are used to quantify the spatial coherence of backscattered echoes at each point of the volume. The capability of 3D-BTI to map the fibers orientation was evaluated in vitro in 5 myocardial samples. The helicoidal transmural variation of fiber angles was in good agreement with the one obtained by histological analysis. 3D-BTI was then performed to map the fiber orientation dynamics in vivo in the beating heart of an open-chest sheep at a volume rate of 90 volumes/s. Finally, the clinical feasibility of 3D-BTI was shown on a healthy volunteer. These initial results indicate that 3D-BTI could become a fully non-invasive technique to assess myocardial disarray at the bedside of patients.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
Quantitative pulsatility measurements using 3D Dynamic Ultrasound Localization Microscopy
Authors:
Chloé Bourquin,
Jonathan Porée,
Brice Rauby,
Vincent Perrot,
Nin Ghigo,
Hatim Belgharbi,
Samuel Bélanger,
Gerardo Ramos-Palacios,
Nelson Cortés,
Hugo Ladret,
Lamyae Ikan,
Christian Casanova,
Frédéric Lesage,
Jean Provost
Abstract:
A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM…
▽ More
A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures biased velocities due to 2D projection. Herein, we present 3D DULM, which can extract quantitative pulsatility measurements in the cat brain with craniotomy and in the whole mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, and performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the whole brain volume, which could be linked to early signs of neurodegenerative diseases.
△ Less
Submitted 24 March, 2023;
originally announced March 2023.
-
A Brief History of the Energy-Momentum Tensor; 1900-1912
Authors:
Jean-Pierre Provost
Abstract:
A critical look at the history of relativistic dynamics.
A critical look at the history of relativistic dynamics.
△ Less
Submitted 28 November, 2012;
originally announced November 2012.
-
From Galilean Relativity to Quantum Gravity : Three Issues, c, h, G, concerning Time, Matter and Inertia
Authors:
Jean-Pierre Provost
Abstract:
An odd look at "standard" physics (Galileo, Newton, Einstein, Dirac) leading to a radical change of our concept of inertial motion and to new heuristic approaches of gravitation and the cosmological constant.
An odd look at "standard" physics (Galileo, Newton, Einstein, Dirac) leading to a radical change of our concept of inertial motion and to new heuristic approaches of gravitation and the cosmological constant.
△ Less
Submitted 19 March, 2011;
originally announced March 2011.
-
Poincare and relativity: the logic of the 1905 Palermo Memoir
Authors:
Christian Bracco,
Jean-Pierre Provost
Abstract:
We highlight four points which have been ignored or underestimated before and which allow a better understanding of "Sur la dynamique de l'electron": (i) the use by Poincare of active Lorentz transformations (boosts); (ii) the necessity, required by mechanics, of a group condition l=1 eliminating dilations; (iii) the key role of the action (electromagnetic or not) and of its invariance; (iv) the…
▽ More
We highlight four points which have been ignored or underestimated before and which allow a better understanding of "Sur la dynamique de l'electron": (i) the use by Poincare of active Lorentz transformations (boosts); (ii) the necessity, required by mechanics, of a group condition l=1 eliminating dilations; (iii) the key role of the action (electromagnetic or not) and of its invariance; (iv) the mathematical status of electron models as example or counter-example.
△ Less
Submitted 23 January, 2010;
originally announced January 2010.
-
Had the planet mars not existed: Kepler's equant model and its physical consequences
Authors:
Christian Bracco,
Jean-Pierre Provost
Abstract:
We examine the equant model for the motion of planets, which has been the starting point of Kepler's investigations before he modified it because of Mars observations. We show that, up to first order in eccentricity, this model implies for each orbit a velocity which satisfies Kepler's second law and Hamilton's hodograph, and a centripetal acceleration with an inverse square dependence on the di…
▽ More
We examine the equant model for the motion of planets, which has been the starting point of Kepler's investigations before he modified it because of Mars observations. We show that, up to first order in eccentricity, this model implies for each orbit a velocity which satisfies Kepler's second law and Hamilton's hodograph, and a centripetal acceleration with an inverse square dependence on the distance to the sun. If this dependence is assumed to be universal, Kepler's third law follows immediately. This elementary execice in kinematics for undergraduates emphasizes the proximity of the equant model coming from Ancient Greece with our present knowledge. It adds to its historical interest a didactical relevance concerning, in particular, the discussion of the Aristotelian or Newtonian conception of motion.
△ Less
Submitted 2 June, 2009;
originally announced June 2009.
-
A simple derivation of Kepler's laws without solving differential equations
Authors:
J. -P. Provost,
C. Bracco
Abstract:
Proceeding like Newton with a discrete time approach of motion and a geometrical representation of velocity and acceleration, we obtain Kepler's laws without solving differential equations. The difficult part of Newton's work, when it calls for non trivial properties of ellipses, is avoided by the introduction of polar coordinates. Then a simple reconsideration of Newton's figure naturally leads…
▽ More
Proceeding like Newton with a discrete time approach of motion and a geometrical representation of velocity and acceleration, we obtain Kepler's laws without solving differential equations. The difficult part of Newton's work, when it calls for non trivial properties of ellipses, is avoided by the introduction of polar coordinates. Then a simple reconsideration of Newton's figure naturally leads to en explicit expression of the velocity and to the equation of the trajectory. This derivation, which can be fully apprehended by beginners at university (or even before) can be considered as a first application of mechanical concepts to a physical problem of great historical and pedagogical interest.
△ Less
Submitted 15 December, 2008;
originally announced December 2008.
-
A Pedagogical Discussion Concerning the Gravitational Energy Radiated by Keplerian Systems
Authors:
C. Bracco,
J. -P. Provost,
P. Salati
Abstract:
We first discuss the use of dimensional arguments (and of the quadrupolar emission hypothesis) in the derivation of the gravitational power radiated on a circular orbit. Then, we show how to simply obtain the instantaneous power radiated on a general Keplerian orbit by approximating it locally by a circle. This allows recovering with a good precision, in the case of an ellipse, the highly non tr…
▽ More
We first discuss the use of dimensional arguments (and of the quadrupolar emission hypothesis) in the derivation of the gravitational power radiated on a circular orbit. Then, we show how to simply obtain the instantaneous power radiated on a general Keplerian orbit by approximating it locally by a circle. This allows recovering with a good precision, in the case of an ellipse, the highly non trivial dependence on the eccentricity of the average power given by general relativity. The whole approach is understandable by undergraduate students.
△ Less
Submitted 3 April, 2009; v1 submitted 3 November, 2008;
originally announced November 2008.