-
European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment
Authors:
PIONEER Collaboration,
A. Adelmann,
W. Altmannshofer,
S. Ban,
O. Beesley,
A. Bolotnikov,
T. Brunner,
D. Bryman,
Q. Buat,
L. Caminada,
J. Carlton,
S. Chen,
M. Chiu,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
J. Datta,
B. Davis-Purcell,
A. Deshpande,
A. Di Canto,
A. Ebrahimi,
P. Fisher,
S. Foster,
K. Frahm
, et al. (54 additional authors not shown)
Abstract:
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimen…
▽ More
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimental result $R_{e/μ}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/μ}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.
△ Less
Submitted 14 April, 2025; v1 submitted 8 April, 2025;
originally announced April 2025.
-
Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. Di Canto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than…
▽ More
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.
△ Less
Submitted 10 March, 2022;
originally announced March 2022.
-
PIONEER: Studies of Rare Pion Decays
Authors:
PIONEER Collaboration,
W. Altmannshofer,
H. Binney,
E. Blucher,
D. Bryman,
L. Caminada,
S. Chen,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
A. DiCanto,
L. Doria,
A. Gaponenko,
A. Garcia,
L. Gibbons,
C. Glaser,
M. Escobar Godoy,
D. Göldi,
S. Gori,
T. Gorringe,
D. Hertzog,
Z. Hodge,
M. Hoferichter,
S. Ito
, et al. (36 additional authors not shown)
Abstract:
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the c…
▽ More
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.
△ Less
Submitted 7 March, 2022; v1 submitted 3 March, 2022;
originally announced March 2022.
-
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
Authors:
T. Albahri,
A. Anastasi,
K. Badgley,
S. Baeßler,
I. Bailey,
V. A. Baranov,
E. Barlas-Yucel,
T. Barrett,
F. Bedeschi,
M. Berz,
M. Bhattacharya,
H. P. Binney,
P. Bloom,
J. Bono,
E. Bottalico,
T. Bowcock,
G. Cantatore,
R. M. Carey,
B. C. K. Casey,
D. Cauz,
R. Chakraborty,
S. P. Chang,
A. Chapelain,
S. Charity,
R. Chislett
, et al. (152 additional authors not shown)
Abstract:
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is fe…
▽ More
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.
△ Less
Submitted 23 April, 2021; v1 submitted 7 April, 2021;
originally announced April 2021.
-
Systematic and Statistical Uncertainties of the Hilbert-Transform Based High-precision FID Frequency Extraction Method
Authors:
Ran Hong,
Simon Corrodi,
Saskia Charity,
Stefan Baessler,
Jason Bono,
Timothy Chupp,
Martin Fertl,
David Flay,
Alejandro Garcia,
Jimin George,
Kevin Louis Giovanetti,
Timothy Gorringe,
Joseph Grange,
Kyun Woo Hong,
David Kawall,
Brendan Kiburg,
Bingzhi Li,
Rachel Osofsky,
Dinko Pocanic,
Suvarna Ramachandran,
Matthias Smith,
Herbert Erik Swanson,
Alec Tewsley-Booth,
Peter Winter,
Tianyu Yang
, et al. (1 additional authors not shown)
Abstract:
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation…
▽ More
Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $χ^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $χ^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.
△ Less
Submitted 27 January, 2021; v1 submitted 20 January, 2021;
originally announced January 2021.
-
Beam particle tracking with a low-mass mini time projection chamber in the PEN experiment
Authors:
C. J. Glaser,
D. Pocanic,
A. van der Schaaf,
V. A. Baranov,
N. V. Khomutov,
N. P. Kravchuk,
N. A. Kuchinsky
Abstract:
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $π^+ \to e^+ν_e(γ)$, aka $π_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number of detection systems, all contributing vital information to the PEN event reconstruction. This paper discusses the design, performance, and Monte Carlo simulation of the m…
▽ More
The international PEN collaboration aims to obtain the branching ratio for the pion electronic decay $π^+ \to e^+ν_e(γ)$, aka $π_{e2}$, to a relative precision of $5\times 10^{-4}$ or better. The PEN apparatus comprises a number of detection systems, all contributing vital information to the PEN event reconstruction. This paper discusses the design, performance, and Monte Carlo simulation of the mini time projection chamber (mTPC) used for pion, muon, and positron beam particle tracking. We also review the use of the extracted trajectory coordinates in the analysis, in particular in constructing observables critical for discriminating background processes, and in maximizing the fiducial volume of the target in which decay event vertices can be accepted for branching ratio extraction without introducing bias.
△ Less
Submitted 20 May, 2021; v1 submitted 22 December, 2020;
originally announced December 2020.
-
Performance of the Muon $g-2$ calorimeter and readout systems measured with test beam data
Authors:
K. S. Khaw,
M. Bartolini,
H. Binney,
R. Bjorkquist,
A. Chapelain,
A. Driutti,
C. Ferrari,
A. T. Fienberg,
A. Fioretti,
C. Gabbanini,
S. Ganguly,
L. K. Gibbons,
A. Gioiosa,
K. Giovanetti,
W. P. Gohn,
T. P. Gorringe,
J. B. Hempstead,
D. W. Hertzog,
M. Iacovacci,
J. Kaspar,
A. Kuchibhotla,
S. Leo,
A. Lusiani,
S. Mastroianni,
G. Pauletta
, et al. (9 additional authors not shown)
Abstract:
A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS dat…
▽ More
A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.
△ Less
Submitted 22 February, 2020; v1 submitted 10 May, 2019;
originally announced May 2019.
-
Using Nab to determine correlations in unpolarized neutron decay
Authors:
L. J. Broussard,
S. Baeßler,
T. L. Bailey,
N. Birge,
J. D. Bowman,
C. B. Crawford,
C. Cude-Woods,
D. E. Fellers,
N. Fomin,
E. Frlež,
M. T. W. Gericke,
L. Hayen,
A. P. Jezghani,
H. Li,
N. Macsai,
M. F. Makela,
R. R. Mammei,
D. Mathews,
P. L. McGaughey,
P. E. Mueller,
D. Počanić,
C. A. Royse,
A. Salas-Bacci,
S. K. L. Sjue,
J. C. Ramsey
, et al. (6 additional authors not shown)
Abstract:
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and…
▽ More
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Design and Performance of the Spin Asymmetries of the Nucleon Experiment
Authors:
J. D. Maxwell,
W. R. Armstrong,
S. Choi,
M. K. Jones,
H. Kang,
A. Liyanage,
Z. -E. Meziani,
J. Mulholland,
L. Ndukum,
O. A. Rondon,
A. Ahmidouch,
I. Albayrak,
A. Asaturyan,
O. Ates,
H. Baghdasaryan,
W. Boeglin,
P. Bosted,
E. Brash,
J. Brock,
C. Butuceanu,
M. Bychkov,
C. Carlin,
P. Carter,
C. Chen,
J. -P. Chen
, et al. (80 additional authors not shown)
Abstract:
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employin…
▽ More
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target whose magnetic field direction could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables $A_1$, $A_2$, $g_1$, $g_2$ and moment $d_2$ of the proton. This document summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.
△ Less
Submitted 21 December, 2017; v1 submitted 22 November, 2017;
originally announced November 2017.
-
Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications
Authors:
J. Kaspar,
A. T. Fienberg,
D. W. Hertzog,
M. A. Huehn,
P. Kammel,
K. S. Khaw,
D. A. Peterson,
M. W. Smith,
T. D. Van Wechel,
A. Chapelain,
L. K. Gibbons,
D. A. Sweigart,
C. Ferrari,
A. Fioretti,
C. Gabbanini,
G. Venanzoni,
M. Iacovacci,
S. Mastroianni,
K. Giovanetti,
W. Gohn,
T. Gorringe,
D. Pocanic
Abstract:
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storag…
▽ More
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. The performance is documented in a series of bench and beam tests.
△ Less
Submitted 22 December, 2016; v1 submitted 9 November, 2016;
originally announced November 2016.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Muon (g-2) Technical Design Report
Authors:
J. Grange,
V. Guarino,
P. Winter,
K. Wood,
H. Zhao,
R. M. Carey,
D. Gastler,
E. Hazen,
N. Kinnaird,
J. P. Miller,
J. Mott,
B. L. Roberts,
J. Benante,
J. Crnkovic,
W. M. Morse,
H. Sayed,
V. Tishchenko,
V. P. Druzhinin,
B. I. Khazin,
I. A. Koop,
I. Logashenko,
Y. M. Shatunov,
E. Solodov,
M. Korostelev,
D. Newton
, et al. (176 additional authors not shown)
Abstract:
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should…
▽ More
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.
△ Less
Submitted 11 May, 2018; v1 submitted 27 January, 2015;
originally announced January 2015.
-
Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
Authors:
A. T. Fienberg,
L. P. Alonzi,
A. Anastasi,
R. Bjorkquist,
D. Cauz,
R. Fatemi,
C. Ferrari,
A. Fioretti,
A. Frankenthal,
C. Gabbanini,
L. K. Gibbons,
K. Giovanetti,
S. D. Goadhouse,
W. P. Gohn,
T. P. Gorringe,
D. W. Hertzog,
M. Iacovacci,
P. Kammel,
J. Kaspar,
B. Kiburg,
L. Li,
S. Mastroianni,
G. Pauletta,
D. A. Peterson,
D. Pocanic
, et al. (8 additional authors not shown)
Abstract:
The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 -- 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes…
▽ More
The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 -- 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes versus energy, impact position, angle, and crystal wrapping. The SiPMs were gain matched using a laser-based calibration system, which also provided a stabilization procedure that allowed gain correction to a level of 1e-4 per hour. After accounting for longitudinal fluctuation losses, those crystals wrapped in a white, diffusive wrapping exhibited an energy resolution sigma/E of (3.4 +- 0.1) % per sqrt(E/GeV), while those wrapped in a black, absorptive wrapping had (4.6 +- 0.3) % per sqrt(E/GeV). The white-wrapped crystals---having nearly twice the total light collection---display a generally wider and impact-position-dependent pulse shape owing to the dynamics of the light propagation, in comparison to the black-wrapped crystals, which have a narrower pulse shape that is insensitive to impact position.
△ Less
Submitted 19 February, 2015; v1 submitted 17 December, 2014;
originally announced December 2014.
-
New precision measurements of free neutron beta decay with cold neutrons
Authors:
S. Baeßler,
J. D. Bowman,
S. Penttilä,
D. Počanić
Abstract:
Precision measurements in free neutron beta decay serve to determine the coupling constants of beta decay, and offer several stringent tests of the Standard Model. This paper describes the free neutron beta decay program planned for the Fundamental Physics Beamline at the Spallation Neutron Source at Oak Ridge National Laboratory, and puts it into the context of other recent and planned measuremen…
▽ More
Precision measurements in free neutron beta decay serve to determine the coupling constants of beta decay, and offer several stringent tests of the Standard Model. This paper describes the free neutron beta decay program planned for the Fundamental Physics Beamline at the Spallation Neutron Source at Oak Ridge National Laboratory, and puts it into the context of other recent and planned measurements of neutron beta decay observables.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
Mu2e Conceptual Design Report
Authors:
The Mu2e Project,
Collaboration,
:,
R. J. Abrams,
D. Alezander,
G. Ambrosio,
N. Andreev,
C. M. Ankenbrandt,
D. M. Asner,
D. Arnold,
A. Artikov,
E. Barnes,
L. Bartoszek,
R. H. Bernstein,
K. Biery,
V. Biliyar,
R. Bonicalzi,
R. Bossert,
M. Bowden,
J. Brandt,
D. N. Brown,
J. Budagov,
M. Buehler,
A. Burov,
R. Carcagno
, et al. (203 additional authors not shown)
Abstract:
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe…
▽ More
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.
△ Less
Submitted 29 November, 2012;
originally announced November 2012.
-
The automatic gain-matching in the PIBETA CsI calorimeter
Authors:
E. Frlez,
M. Bychkov,
D. Pocanic
Abstract:
Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as the spatial and energy resolutions are affected differently. Increased number of individual detectors reduces accidental particle pile-up per detector but intr…
▽ More
Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as the spatial and energy resolutions are affected differently. Increased number of individual detectors reduces accidental particle pile-up per detector but introduces complications related to ADC pedestals and pedestal variations, exacerbates the effects of electronic noise and ground loops, and requires summing and discrimination of multiple analog signals. Moreover, electromagnetic showers initiated by individual ionizing particles spread over several detectors. This complicates the precise gain-matching of the detector elements which requires an iterative procedure. The PIBETA calorimeter is a 240-module pure CsI non-magnetic detector optimized for detection of photons and electrons in the energy range 5-100 MeV. We present the computer-controlled, automatic, in situ gain-matching procedure that we developed and used routinely in several rare pion and muon decay experiments with the PIBETA detector.
△ Less
Submitted 27 April, 2008;
originally announced April 2008.
-
Design, Commissioning and Performance of the PIBETA Detector at PSI
Authors:
E. Frlez,
D. Pocanic,
K. A. Assamagan,
Yu. Bagaturia,
V. A. Baranov,
W. Bertl,
Ch. Broennimann,
M. A. Bychkov,
J. F. Crawford,
M. Daum,
Th. Fluegel,
R. Frosch,
R. Horisberger,
V. A. Kalinnikov,
V. V. Karpukhin,
N. V. Khomutov,
J. E. Koglin,
A. S. Korenchenko,
S. M. Korenchenko,
T. Kozlowski,
B. Krause,
N. P. Kravchuk,
N. A. Kuchinsky,
W. Li,
D. W. Lawrence
, et al. (19 additional authors not shown)
Abstract:
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an ac…
▽ More
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.
△ Less
Submitted 4 December, 2003;
originally announced December 2003.
-
Radiation hardness of the PIBETA detector components
Authors:
E. Frlez,
T. A. Campbell,
I. J. Carey,
D. Pocanic
Abstract:
We have examined long term changes in signal amplitude gain, energy resolution and detection efficiency for the active components of the PIBETA detector system. Beam defining plastic scintillation counters were operated in a ~1 MHz stopped $π^+$ beam for a period of 297 days, accumulating radiation doses of up to 2 Mrad. Detectors in the charged particle tracking system--a pair of cylindrical mu…
▽ More
We have examined long term changes in signal amplitude gain, energy resolution and detection efficiency for the active components of the PIBETA detector system. Beam defining plastic scintillation counters were operated in a ~1 MHz stopped $π^+$ beam for a period of 297 days, accumulating radiation doses of up to 2 Mrad. Detectors in the charged particle tracking system--a pair of cylindrical multi-wire proportional chambers and a thin plastic scintillation barrel-shaped hodoscope array--were irradiated during the same running period with an average dose of ~40 krad. Individual CsI(undoped crystal) calorimeter detectors received an average dose of ~120 rad, mainly from photons, positrons and protons originating from $π^+$ hadronic interactions as well as from $π^+$ and $μ^+$ weak decays at rest in the active target.
△ Less
Submitted 2 December, 2002;
originally announced December 2002.