-
Future Circular Collider Feasibility Study Report: Volume 2, Accelerators, Technical Infrastructure and Safety
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
A. Abada
, et al. (1439 additional authors not shown)
Abstract:
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory;…
▽ More
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory; followed by a proton-proton collider (FCC-hh) at the energy frontier in the second phase.
FCC-ee is designed to operate at four key centre-of-mass energies: the Z pole, the WW production threshold, the ZH production peak, and the top/anti-top production threshold - delivering the highest possible luminosities to four experiments. Over 15 years of operation, FCC-ee will produce more than 6 trillion Z bosons, 200 million WW pairs, nearly 3 million Higgs bosons, and 2 million top anti-top pairs. Precise energy calibration at the Z pole and WW threshold will be achieved through frequent resonant depolarisation of pilot bunches. The sequence of operation modes remains flexible.
FCC-hh will operate at a centre-of-mass energy of approximately 85 TeV - nearly an order of magnitude higher than the LHC - and is designed to deliver 5 to 10 times the integrated luminosity of the HL-LHC. Its mass reach for direct discovery extends to several tens of TeV. In addition to proton-proton collisions, FCC-hh is capable of supporting ion-ion, ion-proton, and lepton-hadron collision modes.
This second volume of the Feasibility Study Report presents the complete design of the FCC-ee collider, its operation and staging strategy, the full-energy booster and injector complex, required accelerator technologies, safety concepts, and technical infrastructure. It also includes the design of the FCC-hh hadron collider, development of high-field magnets, hadron injector options, and key technical systems for FCC-hh.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 3, Civil Engineering, Implementation and Sustainability
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. I…
▽ More
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. It outlines a technically feasible and economically viable civil engineering configuration that serves as the baseline for detailed subsurface investigations, construction design, cost estimation, and project implementation planning. Additionally, the report highlights ongoing subsurface investigations in key areas to support the development of an improved 3D subsurface model of the region.
The report describes development of the project scenario based on the 'avoid-reduce-compensate' iterative optimisation approach. The reference scenario balances optimal physics performance with territorial compatibility, implementation risks, and costs. Environmental field investigations covering almost 600 hectares of terrain - including numerous urban, economic, social, and technical aspects - confirmed the project's technical feasibility and contributed to the preparation of essential input documents for the formal project authorisation phase. The summary also highlights the initiation of public dialogue as part of the authorisation process. The results of a comprehensive socio-economic impact assessment, which included significant environmental effects, are presented. Even under the most conservative and stringent conditions, a positive benefit-cost ratio for the FCC-ee is obtained. Finally, the report provides a concise summary of the studies conducted to document the current state of the environment.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 1, Physics, Experiments, Detectors
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model.…
▽ More
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools /reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Physics Perspectives with the ePIC Far-Forward and Far-Backward detectors
Authors:
Michael Pitt
Abstract:
The forthcoming Electron--Ion Collider (EIC), which is expected to commence operations in the early 2030s, has already reached several significant milestones on its path toward completion. The core of the EIC physics program is the 3D imaging of partonic structures in protons and nuclei. The experimental detector setup required to enable this primary objective utilizes "far-forward" (FF) and "far-…
▽ More
The forthcoming Electron--Ion Collider (EIC), which is expected to commence operations in the early 2030s, has already reached several significant milestones on its path toward completion. The core of the EIC physics program is the 3D imaging of partonic structures in protons and nuclei. The experimental detector setup required to enable this primary objective utilizes "far-forward" (FF) and "far-backward" (FB) detectors positioned downstream in the hadron-going and electron-going directions, respectively, from the interaction point of the EIC. The primary purpose of the FB detectors is to monitor luminosity and measure scattered electrons in collisions in the EIC, while the array of FF detectors is used to tag and reconstruct both charged and neutral particles that scatter at small angles. These detectors also enable a broader physics program than was initially envisioned, enhancing the EIC's research potential. The expanded capabilities have been a prime focus for engaging the broader nuclear physics community to build a robust groundwork for the EIC. In these proceedings, we will describe the FF/FB detectors and review the advanced forward physics program facilitated by them at the EIC.
△ Less
Submitted 4 September, 2024;
originally announced September 2024.
-
The ECFA Early-Career Researchers Panel: Report for the year 2023
Authors:
Julia Allen,
Bruno Alves,
Jan-Hendrik Arling,
Kamil Augsten,
Emanuele Bagnaschi,
Giovanni Benato,
Anna Bennecke,
Cecilia Borca,
Paulo Braz,
Lydia Brenner,
Jordy Degens,
Yannick Dengler,
Christina Dimitriadi,
Eleonora Diociaiuti,
Laurent Dufour,
Patrick Dunne,
Ozgur Etisken,
Silvia Ferrario Ravasio,
Nikolai Fomin,
Andrea Garcia Alonso,
Leif Gellersen,
Andreas Gsponer,
Tomas Herman,
Bojan Hiti,
Laura Huhta
, et al. (45 additional authors not shown)
Abstract:
The European Committee for Future Accelerators (ECFA) Early-Career Researcher (ECR) panel, which represents the interests of the ECR community to ECFA, presents in this document its initiatives and activities in the year 2023. This report summarises the process of the first big turnover in the panel composition at the start of 2023 and reports on the activities of the active working groups - eithe…
▽ More
The European Committee for Future Accelerators (ECFA) Early-Career Researcher (ECR) panel, which represents the interests of the ECR community to ECFA, presents in this document its initiatives and activities in the year 2023. This report summarises the process of the first big turnover in the panel composition at the start of 2023 and reports on the activities of the active working groups - either pursued from before or newly established. The overarching goal of the ECFA-ECR panel is to better understand and support the diverse interests of early-career researchers in the ECFA community and beyond.
△ Less
Submitted 17 July, 2024;
originally announced July 2024.
-
The ECFA Early Career Researcher's Panel: composition, structure, and activities, 2021 -- 2022
Authors:
ECFA Early-Career Researcher Panel,
:,
Andrei Alexandru Geanta,
Chiara Amendola,
Liliana Apolinario,
Jan-Hendrik Arling,
Adi Ashkenazi,
Kamil Augsten,
Emanuele Bagnaschi,
Evelin Bakos,
Liron Barak,
Diogo Bastos,
Giovanni Benato,
Bugra Bilin,
Neven Blaskovic Kraljevic,
Lydia Brenner,
Francesco Brizioli,
Antoine Camper,
Alessandra Camplani,
Xabier Cid Vidal,
Hüseyin Dag,
Flavia de Almeida Dias,
Jordy Degens,
Eleonora Diociaiuti,
Laurent Dufour
, et al. (52 additional authors not shown)
Abstract:
The European Committee for Future Accelerators (ECFA) Early Career Researcher's (ECR) panel, which represents the interests of the ECR community to ECFA, officially began its activities in January 2021. In the first two years, the panel has defined its own internal structure, responded to ECFA requests for feedback, and launched its own initiatives to better understand and support the diverse inte…
▽ More
The European Committee for Future Accelerators (ECFA) Early Career Researcher's (ECR) panel, which represents the interests of the ECR community to ECFA, officially began its activities in January 2021. In the first two years, the panel has defined its own internal structure, responded to ECFA requests for feedback, and launched its own initiatives to better understand and support the diverse interests of early career researchers. This report summarises the panel composition and structure, as well as the different activities the panel has been involved with during the first two years of its existence.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Results of the 2021 ECFA Early-Career Researcher Survey on Training in Instrumentation
Authors:
ECFA Early-Career Researcher Panel,
:,
Anamika Aggarwal,
Chiara Amendola,
Liliana Apolinario,
Jan-Hendrik Arling,
Adi Ashkenazi,
Kamil Augsten,
Julien Baglio,
Evelin Bakos,
Liron Barak,
Diogo Bastos,
Bugra Bilin,
Silvia Biondi,
Neven Blaskovic Kraljevic,
Lydia Brenner,
Francesco Brizioli,
Antoine Camper,
Alessandra Camplani,
Xabier Cid Vidal,
Hüseyin Dag,
Flavia de Almeida Dias,
Eleonora Diociaiuti,
Lennart van Doremalen,
Katherine Dunne
, et al. (52 additional authors not shown)
Abstract:
The European Committee for Future Accelerators (ECFA) Early-Career Researchers (ECR) Panel was invited by the ECFA Detector R&D Roadmap conveners to collect feedback from the European ECR community. A working group within the ECFA ECR panel held a Townhall Meeting to get first input, and then designed and broadly circulated a detailed survey to gather feedback from the larger ECR community. A tota…
▽ More
The European Committee for Future Accelerators (ECFA) Early-Career Researchers (ECR) Panel was invited by the ECFA Detector R&D Roadmap conveners to collect feedback from the European ECR community. A working group within the ECFA ECR panel held a Townhall Meeting to get first input, and then designed and broadly circulated a detailed survey to gather feedback from the larger ECR community. A total of 473 responses to this survey were received, providing a useful overview of the experiences of ECRs in instrumentation training and related topics. This report summarises the feedback received, and is intended to serve as an input to the ECFA Detector R&D Roadmap process.
△ Less
Submitted 1 July, 2021;
originally announced July 2021.
-
Towards a Computer Vision Particle Flow
Authors:
Francesco Armando Di Bello,
Sanmay Ganguly,
Eilam Gross,
Marumi Kado,
Michael Pitt,
Lorenzo Santi,
Jonathan Shlomi
Abstract:
In High Energy Physics experiments Particle Flow (PFlow) algorithms are designed to provide an optimal reconstruction of the nature and kinematic properties of the particles produced within the detector acceptance during collisions. At the heart of PFlow algorithms is the ability to distinguish the calorimeter energy deposits of neutral particles from those of charged particles, using the compleme…
▽ More
In High Energy Physics experiments Particle Flow (PFlow) algorithms are designed to provide an optimal reconstruction of the nature and kinematic properties of the particles produced within the detector acceptance during collisions. At the heart of PFlow algorithms is the ability to distinguish the calorimeter energy deposits of neutral particles from those of charged particles, using the complementary measurements of charged particle tracking devices, to provide a superior measurement of the particle content and kinematics. In this paper, a computer vision approach to this fundamental aspect of PFlow algorithms, based on calorimeter images, is proposed. A comparative study of the state of the art deep learning techniques is performed. A significantly improved reconstruction of the neutral particle calorimeter energy deposits is obtained in a context of large overlaps with the deposits from charged particles. Calorimeter images with augmented finer granularity are also obtained using super-resolution techniques.
△ Less
Submitted 3 February, 2021; v1 submitted 19 March, 2020;
originally announced March 2020.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$
Authors:
X. Sun,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu
, et al. (35 additional authors not shown)
Abstract:
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) exper…
▽ More
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.
△ Less
Submitted 28 March, 2018;
originally announced March 2018.
-
The P2 Experiment - A future high-precision measurement of the electroweak mixing angle at low momentum transfer
Authors:
Dominik Becker,
Razvan Bucoveanu,
Carsten Grzesik,
Ruth Kempf,
Kathrin Imai,
Matthias Molitor,
Alexey Tyukin,
Marco Zimmermann,
David Armstrong,
Kurt Aulenbacher,
Sebastian Baunack,
Rakitha Beminiwattha,
Niklaus Berger,
Peter Bernhard,
Andrea Brogna,
Luigi Capozza,
Silviu Covrig Dusa,
Wouter Deconinck,
Jürgen Diefenbach,
Jens Erler,
Ciprian Gal,
Boris Gläser,
Boxing Gou,
Wolfgang Gradl,
Michael Gericke
, et al. (20 additional authors not shown)
Abstract:
This article describes the future P2 parity-violating electron scattering facility at the upcoming MESA accelerator in Mainz. The physics program of the facility comprises indirect, high precision search for physics beyond the Standard Model, measurement of the neutron distribution in nuclear physics, single-spin asymmetries stemming from two-photon exchange and a possible future extension to the…
▽ More
This article describes the future P2 parity-violating electron scattering facility at the upcoming MESA accelerator in Mainz. The physics program of the facility comprises indirect, high precision search for physics beyond the Standard Model, measurement of the neutron distribution in nuclear physics, single-spin asymmetries stemming from two-photon exchange and a possible future extension to the measurement of hadronic parity violation. The first measurement of the P2 experiment aims for a high precision determination of the weak mixing angle to a precision of 0.14% at a four-momentum transfer of Q^2 = 4.5 10^{-3} GeV^2. The accuracy is comparable to existing measurements at the Z pole. It comprises a sensitive test of the standard model up to a mass scale of 50 TeV, extendable to 70 TeV. This requires a measurement of the parity violating cross section asymmetry -39.94 10^{-9} in the elastic electron-proton scattering with a total accuracy of 0.56 10^-9 (1.4 %) in 10,000 h of 150 \micro A polarized electron beam impinging on a 60 cm liquid H_2 target allowing for an extraction of the weak charge of the proton which is directly connected to the weak mixing angle. Contributions from gamma Z-box graphs become small at the small beam energy of 155 MeV. The size of the asymmetry is the smallest asymmetry ever measured in electron scattering with an unprecedented goal for the accuracy. We report here on the conceptual design of the P2 spectrometer, its Cherenkov detectors, the integrating read-out electronics as well as the ultra-thin, fast tracking detectors. There has been substantial theory work done in preparation of the determination of the weak mixing angle. The further physics program in particle and nuclear physics is described as well.
△ Less
Submitted 14 March, 2018; v1 submitted 13 February, 2018;
originally announced February 2018.
-
Measurements of charging-up processes in THGEM-based particle detectors
Authors:
M. Pitt,
P. M. M. Correia,
S. Bressler,
A. E. C. Coimbra,
D. Shaked Renous,
C. D. R. Azevedo,
J. F. C. A. Veloso,
A. Breskin
Abstract:
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's envi…
▽ More
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's environment, the gain stabilization process is mainly affected by the charging-up of the detector's insulating surfaces caused by the avalanche charges. The charging-up is a transient effect, occurring during the detector's initial operation period; it does not affect its long-term operation. The experimental results are consistent with the outcome of model-simulations.
△ Less
Submitted 9 January, 2018; v1 submitted 1 January, 2018;
originally announced January 2018.
-
Simulation of gain stability of THGEM gas-avalanche particle detectors
Authors:
P. M. M. Correia,
M. Pitt,
C. D. R. Azevedo,
A. Breskin,
S. Bressler,
C. A. B. Oliveira,
A. L. M. Silva,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in rel…
▽ More
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in relation to physical parameters. Simulation results of gain stability over time in THGEM detectors are presented, exploring the role of electrode-thickness and applied voltage on its evolution. The results show that the total amount of irradiated charge through electrode's hole needed for reaching gain stabilization is in the range of tens to hundreds of pC, depending on the detector geometry and operational voltage. These results are in agreement with experimental observations presented previously.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
E. Oliveri,
M. Pitt,
J. Schaarschmidt,
D. Shaked-Renous,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin,
S. Bressler
Abstract:
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv…
▽ More
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, dropping by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
△ Less
Submitted 15 March, 2016;
originally announced March 2016.
-
First in-beam studies of a Resistive-Plate WELL gaseous multiplier
Authors:
S. Bressler,
L. Moleri,
M. Pitt,
S. Kudella,
D. C. R. Azevedo,
F. D. Amaro,
M. R. Jorge,
J. M. F. dos Santos,
J. F. C. A. Veloso,
H. Natal da Luz,
L. Arazi,
E. Olivieri,
A. Breskin
Abstract:
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ squar…
▽ More
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.
△ Less
Submitted 20 January, 2016; v1 submitted 11 October, 2015;
originally announced October 2015.
-
A new type of Neutrino Detector for Sterile Neutrino Search at Nuclear Reactors and Nuclear Nonproliferation Applications
Authors:
C. Lane,
S. M. Usman,
J. Blackmon,
C. Rasco,
H. P. Mumm,
D. Markoff,
G. R. Jocher,
R. Dorrill,
M. Duvall,
J. G. Learned,
V. Li,
J. Maricic,
S. Matsuno,
R. Milincic,
S. Negrashov,
M. Sakai,
M. Rosen,
G. Varner,
P. Huber,
M. L. Pitt,
S. D. Rountree,
R. B. Vogelaar,
T. Wright,
Z. Yokley
Abstract:
We describe a new detector, called NuLat, to study electron anti-neutrinos a few meters from a nuclear reactor, and search for anomalous neutrino oscillations. Such oscillations could be caused by sterile neutrinos, and might explain the "Reactor Antineutrino Anomaly". NuLat, is made possible by a natural synergy between the miniTimeCube and mini-LENS programs described in this paper. It features…
▽ More
We describe a new detector, called NuLat, to study electron anti-neutrinos a few meters from a nuclear reactor, and search for anomalous neutrino oscillations. Such oscillations could be caused by sterile neutrinos, and might explain the "Reactor Antineutrino Anomaly". NuLat, is made possible by a natural synergy between the miniTimeCube and mini-LENS programs described in this paper. It features a "Raghavan Optical Lattice" (ROL) consisting of 3375 boron or $^6$Li loaded plastic scintillator cubical cells 6.3\,cm (2.500") on a side. Cell boundaries have a 0.127\,mm (0.005") air gap, resulting in total internal reflection guiding most of the light down the 3 cardinal directions. The ROL detector technology for NuLat gives excellent spatial and energy resolution and allows for in-depth event topology studies. These features allow us to discern inverse beta decay (IBD) signals and the putative oscillation pattern, even in the presence of other backgrounds. We discuss here test venues, efficiency, sensitivity and project status.
△ Less
Submitted 27 January, 2015;
originally announced January 2015.
-
The Q_weak Experimental Apparatus
Authors:
Qweak Collaboration,
T. Allison,
M. Anderson,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
T. D. Averett,
R. Averill,
J. Balewski,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Bessuille,
J. Birchall,
E. Bonnell,
J. Bowman,
P. Brindza,
D. B. Brown,
R. D. Carlini,
G. D. Cates,
B. Cavness,
G. Clark,
J. C. Cornejo,
S. Covrig Dusa
, et al. (104 additional authors not shown)
Abstract:
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry…
▽ More
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.
△ Less
Submitted 6 January, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.
-
A concept for laboratory studies of radiation detectors over a broad dynamic-range: instabilities evaluation in THGEM-structures
Authors:
S. Bressler,
L. Moleri,
L. Arazi,
E. Erdal,
A. Rubin,
M. Pitt,
A. Breskin
Abstract:
A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge…
▽ More
A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge probability. The methodology, applicable to a broad range of detectors, is applied here for instability studies in various single-stage THGEM and THGEM-WELL structures. The results indicate upon a somewhat larger attainable dynamic range in a single-stage THGEM operated with additional multiplication in the induction gap.
△ Less
Submitted 5 November, 2013; v1 submitted 2 November, 2013;
originally announced November 2013.
-
Laboratory studies of THGEM-based WELL structures with resistive anodes
Authors:
L. Arazi,
M. Pitt,
S. Bressler,
L. Moleri,
A. Rubin,
A. Breskin
Abstract:
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-qu…
▽ More
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-quenching capability, gain variation with position and counting rate, pulse shapes and signal propagation to neighboring readout pads; the study included both 30x30 and 100x100 mm$^2$ detectors. It was shown that the WELL structures with resistive anodes offer stable operation even in a highly ionizing environment, with effective spark quenching, as well as higher gain than the standard THGEM/induction-gap configuration. Cross talk between neighboring readout pads was shown to be effectively eliminated in the segmented detector with a conductive grid underneath the resistive layer. The latter multiplier should allow for the design of very thin detectors, e.g. sampling elements in digital hadronic calorimeters planned for experiments in future linear colliders.
△ Less
Submitted 23 October, 2013;
originally announced October 2013.
-
Recent advances with THGEM detectors
Authors:
S. Bressler,
L. Arazi,
L. Moleri,
M. Pitt,
A. Rubin,
A. Breskin
Abstract:
The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are singl…
▽ More
The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are single-sided THGEM electrodes directly coupled to different anode readout electrodes. The structures differ by the coupling concept of the bottom THGEM electrode to the metallic readout pads: a Thick WELL (THWELL) with direct coupling; the Resistive WELL (RWELL) and the Segmented Resistive WELL (SRWELL) coupled through thin resistive films deposited on insulating sheets and a Resistive-Plate WELL (RPWELL) coupled through a plate of high bulk resistivity. The results are compared to that of traditional double-sided THGEM electrodes followed by induction gaps - in some cases with moderate additional multiplication within the gap. We compare the different configurations in terms of gain, avalanche extension, discharge-rate and magnitude as well as rate capabilities over a broad dynamic range - exploiting a method that mimics highly ionizing particles in the laboratory. We report on recent studies of avalanche distribution in THGEM holes using optical readout.
△ Less
Submitted 15 October, 2013;
originally announced October 2013.
-
First studies with the Resistive-Plate WELL gaseous multiplier
Authors:
A. Rubin,
L. Arazi,
S. Bressler,
L. Moleri,
M. Pitt,
A. Breskin
Abstract:
We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV…
▽ More
We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV x-ray in Ne/5%CH4; a minor 30% gain drop occurred with a rate increase from 10 to 10^4 Hz/mm^2. The detector displayed a full "discharge-free" operation--even when exposed to high primary ionization events. We present the RPWELL detector concept and compare its performance to that of other previously explored THGEM configurations--in terms of gain, its curves, dependence on rate, and the response to high ionization. The robust Resistive Plate WELL concept is a step forward in the Micro-Pattern Gas-Detector family, with numerous potential applications.
△ Less
Submitted 28 August, 2013;
originally announced August 2013.
-
Beam studies of novel THGEM-based potential sampling elements for Digital Hadron Calorimetry
Authors:
S. Bressler,
L. Arazi,
H. Natal da Luz,
C. D. A. Azevedo,
L. Moleri,
E. Oliveri,
M. Pitt,
A. Rubin,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin
Abstract:
Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a resistive layer to APV-SRS readout electronics, were investigated with muons and pions. Detection efficiencies in the 98% range were recorded with an average pad-mu…
▽ More
Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a resistive layer to APV-SRS readout electronics, were investigated with muons and pions. Detection efficiencies in the 98% range were recorded with an average pad-multiplicity of ~1.1. The resistive anode resulted in efficient discharge damping, with few-volt potential drops; discharge probabilities were ~10^{-7} for muons and 10^{-6} for pions in the double-stage configuration, at rates of a few kHz/cm^2. These results, together with the robustness of THGEM electrodes against spark damage and their suitability for economic production over large areas make THGEM-based detectors highly competitive compared to the other technologies considered for the SiD-DHCAL.
△ Less
Submitted 25 July, 2013; v1 submitted 20 May, 2013;
originally announced May 2013.
-
Beam Studies of the Segmented Resistive WELL: a Potential Thin Sampling Element for Digital Hadron Calorimetry
Authors:
Lior Arazi,
Carlos Davide Rocha Azevedo,
Amos Breskin,
Shikma Bressler,
Luca Moleri,
Hugo Natal da Luz,
Eraldo Oliveri,
Michael Pitt,
Adam Rubin,
Joaquim Marques Ferreira dos Santos,
João Filipe Calapez Albuquerque Veloso,
Andrew Paul White
Abstract:
Thick Gas Electron Multipliers (THGEMs) have the potential of constituting thin, robust sampling elements in Digital Hadron Calorimetry (DHCAL) in future colliders. We report on recent beam studies of new single- and double-THGEM-like structures; the multiplier is a Segmented Resistive WELL (SRWELL) - a single-faced THGEM in contact with a segmented resistive layer inductively coupled to readout p…
▽ More
Thick Gas Electron Multipliers (THGEMs) have the potential of constituting thin, robust sampling elements in Digital Hadron Calorimetry (DHCAL) in future colliders. We report on recent beam studies of new single- and double-THGEM-like structures; the multiplier is a Segmented Resistive WELL (SRWELL) - a single-faced THGEM in contact with a segmented resistive layer inductively coupled to readout pads. Several 10$\times$10 cm$^2$ configurations with a total thickness of 5-6 mm (excluding electronics) with 1 cm$^2$ pads coupled to APV-SRS readout were investigated with muons and pions. Detection efficiencies in the 98$%$ range were recorded with average pad-multiplicity of $\sim$1.1. The resistive anode resulted in efficient discharge damping, with potential drops of a few volts; discharge probabilities were $\sim10^{-7}$ for muons and $\sim10^{-6}$ for pions in the double-stage configuration, at rates of a few kHz/cm$^2$. Further optimization work and research on larger detectors are underway.
△ Less
Submitted 7 May, 2013;
originally announced May 2013.
-
Optical readout: a tool for studying gas-avalanche processes
Authors:
A. Rubin,
L. Arazi,
S. Bressler,
A. Dery,
L. Moleri,
M. Pitt,
D. Vartsky,
A. Breskin
Abstract:
Optical recording of avalanche-induced photons is an interesting tool for studying basic physics processes in gaseous detectors. In this work we demonstrate the potential of optical readout in avalanche-propagation investigations in Thick Gas Electron Multipliers (THGEMs) operated with Ne/CF4 (95/5). We present the results of direct measurements, with single- and cascaded-THGEM detectors irradiate…
▽ More
Optical recording of avalanche-induced photons is an interesting tool for studying basic physics processes in gaseous detectors. In this work we demonstrate the potential of optical readout in avalanche-propagation investigations in Thick Gas Electron Multipliers (THGEMs) operated with Ne/CF4 (95/5). We present the results of direct measurements, with single- and cascaded-THGEM detectors irradiated with soft x-rays, of the hole-multiplicity and avalanche asymmetry within holes, as a function of detector parameters. Further study directions are discussed.
△ Less
Submitted 5 January, 2014; v1 submitted 6 May, 2013;
originally announced May 2013.
-
The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge
Authors:
R. D. Carlini,
J. M. Finn,
S. Kowalski,
S. A. Page,
D. S. Armstrong,
A. Asaturyan,
T. Averett,
J. Benesch,
J. Birchall,
P. Bosted,
A. Bruell,
C. L. Capuano,
G. Cates,
C. Carrigee,
S. Chattopadhyay,
S. Covrig,
C. A. Davis,
K. Dow,
J. Dunne,
D. Dutta,
R. Ent,
J. Erler,
W. Falk,
H. Fenker,
T. A. Forest
, et al. (61 additional authors not shown)
Abstract:
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep…
▽ More
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep scattering at Q^2=0.03 (GeV/c)^2 employing 180 $μ$A of 85% polarized beam on a 35 cm liquid Hydrogen target will determine the proton's weak charge with approximately 4% combined statistical and systematic errors. The Standard Model makes a firm prediction of $Q_W$, based on the running of the weak mixing angle from the Z0 pole down to low energies, corresponding to a 10 sigma effect in this experiment.
△ Less
Submitted 7 February, 2012; v1 submitted 6 February, 2012;
originally announced February 2012.
-
THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation
Authors:
L. Arazi,
A. Breskin,
R. Chechik,
M. Cortesi,
M. Pitt,
A. Rubin,
H. Natal da Luz,
J. M. F. dos Santos,
C. D. R. Azevedo,
D. S. Covita,
C. A. B. Oliveira,
J. F. C. A. Veloso,
M. Breidenbach,
D. Freytag,
G. Haller,
R. Herbst,
S. Park,
A. White,
J. Yu,
E. Oliveri
Abstract:
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled…
▽ More
We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.
△ Less
Submitted 8 December, 2011;
originally announced December 2011.
-
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
Authors:
G0 Collaboration,
D. Androic,
D. S. Armstrong,
J. Arvieux,
R. Asaturyan,
T. D. Averett,
S. L. Bailey,
G. Batigne,
D. H. Beck,
E. J. Beise,
J. Benesch,
F. Benmokhtar,
L. Bimbot,
J. Birchall,
A. Biselli,
P. Bosted,
H. Breuer,
P. Brindza,
C. L. Capuano,
R. D. Carlini,
R. Carr,
N. Chant,
Y. -C. Chao,
R. Clark,
A. Coppens
, et al. (105 additional authors not shown)
Abstract:
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized bea…
▽ More
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
△ Less
Submitted 3 March, 2011;
originally announced March 2011.