-
Optical Transmission Characterization of Fused Silica Materials Irradiated at the CERN Large Hadron Collider
Authors:
S. Yang,
A. Tate,
R. Longo,
M. Sabate Gilarte,
F. Cerutti,
S. Mazzoni,
M. Grosse Perdekamp,
E. Bravin,
Z. Citron,
B. Kühn,
F. Nürnberg,
B. Cole,
J. Fritchie,
I. Gelber,
M. Hoppesch,
S. Jackobsen,
T. Koeth,
C. Lantz,
D. MacLean,
A. Mignerey,
M. Murray,
M. Palm,
M. Phipps,
S. Popescu,
N. Santiago
, et al. (1 additional authors not shown)
Abstract:
The Target Absorbers for Neutrals (TANs) represent one of the most radioactive regions in the Large Hadron Collider (LHC). Seven 40 cm long fused silica rods with different dopant specifications, manufactured by Heraeus, were irradiated in one of the TANs located around the ATLAS experiment by the Beam RAte of Neutrals (BRAN) detector group. This campaign took place during the Run 2 p+p data takin…
▽ More
The Target Absorbers for Neutrals (TANs) represent one of the most radioactive regions in the Large Hadron Collider (LHC). Seven 40 cm long fused silica rods with different dopant specifications, manufactured by Heraeus, were irradiated in one of the TANs located around the ATLAS experiment by the Beam RAte of Neutrals (BRAN) detector group. This campaign took place during the Run 2 p+p data taking, which occurred between 2016 and 2018. This paper reports a complete characterization of optical transmission per unit length of irradiated fused silica materials as a function of wavelength (240 nm - 1500 nm), dose (up to 18 MGy), and level of OH and H$_2$ dopants introduced in the manufacturing process. The dose delivered to the rods was estimated using Monte Carlo simulations performed by the CERN FLUKA team.
△ Less
Submitted 8 December, 2022; v1 submitted 6 December, 2022;
originally announced December 2022.
-
$^{22}$Na Activation Level Measurements of Fused Silica Rods in the LHC Target Absorber for Neutrals (TAN) Compared to FLUKA Simulations
Authors:
S. Yang,
M. Sabate Gilarte,
A. Tate,
N. Santiago,
R. Longo,
S. Mazzoni,
F. Cerutti,
E. Bravin,
M. Grosse Perdekamp,
G. Lerner,
D. Prelipcean,
Z. Citron,
B. Cole,
S. Jackobsen,
M. D. Kaminski,
T. Koeth,
C. Lantz,
D. MacLean,
A. Mignerey,
M. Murray,
M. Palm,
M. Phipps,
P. Steinberg,
A. Tsinganis
Abstract:
The Target Absorbers for Neutrals (TANs) are located in a high-intensity radiation environment inside the tunnel of the Large Hadron Collider (LHC). TANs are positioned about $140$ m downstream from the beam interaction points. Seven $40$ cm long fused silica rods with different dopant specifications were irradiated in the TAN by the Beam RAte of Neutrals (BRAN) detector group during $p$+$p$ data…
▽ More
The Target Absorbers for Neutrals (TANs) are located in a high-intensity radiation environment inside the tunnel of the Large Hadron Collider (LHC). TANs are positioned about $140$ m downstream from the beam interaction points. Seven $40$ cm long fused silica rods with different dopant specifications were irradiated in the TAN by the Beam RAte of Neutrals (BRAN) detector group during $p$+$p$ data taking from 2016 to 2018 at the LHC. The peak dose delivered to the fused silica rods was $18$ MGy. We report measurements of the $^{22}$Na activation of the fused silica rods carried out at the University of Illinois at Urbana-Champaign and Argonne National Laboratory. At the end of the irradiation campaign, the maximum $^{22}$Na activity observed was $A=21$ kBq$/{\rm cm^3}$ corresponding to a density, $ρ= 2.5\times 10^{12} /{\rm cm^3}$, of $^{22}$Na nuclei. FLUKA Monte Carlo simulations have been performed by the CERN FLUKA team to estimate $^{22}$Na activities for the irradiated BRAN rod samples. The simulations reproduce the $^{22}$Na activity profile measured along the rods, with a 35% underestimation of the experimental measurement results.
△ Less
Submitted 5 April, 2022; v1 submitted 4 April, 2022;
originally announced April 2022.
-
Ultra-Sharp Nanowire Arrays Natively Permeate, Record, and Stimulate Intracellular Activity in Neuronal and Cardiac Networks
Authors:
Ren Liu,
Jihwan Lee,
Youngbin Tchoe,
Deborah Pre,
Andrew M. Bourhis,
Agnieszka D'Antonio-Chronowska,
Gaelle Robin,
Sang Heon Lee,
Yun Goo Ro,
Ritwik Vatsyayan,
Karen J. Tonsfeldt,
Lorraine A. Hossain,
M. Lisa Phipps,
Jinkyoung Yoo,
John Nogan,
Jennifer S. Martinez,
Kelly A. Frazer,
Anne G. Bang,
Shadi A. Dayeh
Abstract:
Intracellular access with high spatiotemporal resolution can enhance our understanding of how neurons or cardiomyocytes regulate and orchestrate network activity, and how this activity can be affected with pharmacology or other interventional modalities. Nanoscale devices often employ electroporation to transiently permeate the cell membrane and record intracellular potentials, which tend to decre…
▽ More
Intracellular access with high spatiotemporal resolution can enhance our understanding of how neurons or cardiomyocytes regulate and orchestrate network activity, and how this activity can be affected with pharmacology or other interventional modalities. Nanoscale devices often employ electroporation to transiently permeate the cell membrane and record intracellular potentials, which tend to decrease rapidly to extracellular potential amplitudes with time. Here, we report innovative scalable, vertical, ultra-sharp nanowire arrays that are individually addressable to enable long-term, native recordings of intracellular potentials. We report large action potential amplitudes that are indicative of intracellular access from 3D tissue-like networks of neurons and cardiomyocytes across recording days and that do not decrease to extracellular amplitudes for the duration of the recording of several minutes. Our findings are validated with cross-sectional microscopy, pharmacology, and electrical interventions. Our experiments and simulations demonstrate that individual electrical addressability of nanowires is necessary for high-fidelity intracellular electrophysiological recordings. This study advances our understanding of and control over high-quality multi-channel intracellular recordings, and paves the way toward predictive, high-throughput, and low-cost electrophysiological drug screening platforms.
△ Less
Submitted 5 July, 2021; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Ultra-short, MeV-scale laser-plasma positron source for positron annihilation lifetime spectroscopy
Authors:
Thomas L. Audet,
Aaron Alejo,
Luke Calvin,
Mark Hugh Cunningham,
Glenn Ross Frazer,
Nasr A. M. Hafz,
Christos Kamperidis,
Song Li,
Gagik Nersisyan,
Daniel Papp,
Michael Phipps,
Jonathan Richard Warwick,
Gianluca Sarri
Abstract:
Sub-micron defects represent a well-known fundamental problem in manufacturing since they can significantly affect performance and lifetime of virtually any high-value component. Positron annihilation lifetime spectroscopy is arguably the only established method capable of detecting defects down to the sub-nanometer scale but, to date, it only works for surface studies, and with limited resolution…
▽ More
Sub-micron defects represent a well-known fundamental problem in manufacturing since they can significantly affect performance and lifetime of virtually any high-value component. Positron annihilation lifetime spectroscopy is arguably the only established method capable of detecting defects down to the sub-nanometer scale but, to date, it only works for surface studies, and with limited resolution. Here, we experimentally and numerically show that laser-driven systems can overcome these well-known limitations, by generating ultra-short positron beams with a kinetic energy tuneable from 500 keV up to 2 MeV and a number of positrons per shot in a 50 keV energy slice \color{black} of the order of $10^3$. Numerical simulations of the expected performance of a typical mJ-scale kHz laser demonstrate the possibility of generating MeV-scale narrow-band and ultra-short positron beams with a flux exceeding $10^5$ positrons/s, of interest for fast volumetric scanning of materials at high resolution.
△ Less
Submitted 19 April, 2021; v1 submitted 11 September, 2020;
originally announced September 2020.
-
Design and Beam Test Results for the 2D Projective sPHENIX Electromagnetic Calorimeter Prototype
Authors:
C. A. Aidala,
S. Altaf,
R. Belmont,
S. Boose,
D. Cacace,
M. Connors,
E. Desmond,
J. Frantz,
E. A. Gamez,
N. Grau,
J. S. Haggerty,
A. Hodges,
J. Huang,
Y. Kim,
M. D. Lenz,
W. Lenz,
N. A. Lewis,
E. J. Mannel,
J. D. Osborn,
D. V. Perepelitsa,
M. Phipps,
R. Pisani,
S. Polizzo,
A. Pun,
M. L. Purschke
, et al. (13 additional authors not shown)
Abstract:
sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of QCD matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds…
▽ More
sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of QCD matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds to a solid angle of $ Δη\times Δφ= 0.2 \times 0.2$ centered at pseudo-rapidity $η= 1$. The prototype consists of scintillating fibers embedded in a mix of tungsten powder and epoxy. The fibers project back approximately to the center of the sPHENIX detector, giving 2D projectivity. The energy response of the EMCal prototype was studied as a function of position and input energy. The energy resolution of the EMCal prototype was obtained after applying a position dependent energy correction and a beam profile correction. Two separate position dependent corrections were considered. The EMCal energy resolution was found to be $σ(E)/\langle E\rangle = 3.5(0.1) \oplus 13.3(0.2)/\sqrt{E}$ based on the hodoscope position dependent correction, and $σ(E)/\langle E\rangle = 3.0(0.1) \oplus 15.4(0.3)/\sqrt{E}$ based on the cluster position dependent correction. These energy resolution results meet the requirements of the sPHENIX physics program.
△ Less
Submitted 15 March, 2021; v1 submitted 27 March, 2020;
originally announced March 2020.
-
Results from a Prototype Combination TPC Cherenkov Detector with GEM Readout
Authors:
B. Azmoun,
K. Dehmelt,
T. K. Hemmick,
R. Majka,
H. N. Nguyen,
M. Phipps,
M. L. Purschke,
N. Ram,
W. Roh,
D. Shangase,
N. Smirnov,
C. Woody,
A. Zhang
Abstract:
A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of principle to demonstrate that the detector is able to measure particle tracks and provide particle identification information within a common detector volume. T…
▽ More
A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of principle to demonstrate that the detector is able to measure particle tracks and provide particle identification information within a common detector volume. The TPC portion consists of a 10x10x10cm3 field cage, which delivers charge from tracks to a 10x10cm2 quadruple GEM readout. Tracks are reconstructed by interpolating the hit position of clusters on an array of 2x10mm2 zigzag pads The Cherenkov component consists of a 10x10cm2 readout plane segmented into 3x3 square pads, also coupled to a quadruple GEM. As tracks pass though the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the CsI photocathode of the Cherenkov detector. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, as well as results on its particle id capabilities will be discussed.
△ Less
Submitted 26 April, 2019;
originally announced April 2019.
-
A random phased-array for MR-guided transcranial ultrasound neuromodulation in non-human primates
Authors:
Vandiver Chaplin,
Marshal A. Phipps,
Charles F. Caskey
Abstract:
Transcranial focused ultrasound (FUS) is a non-invasive technique for therapy and study of brain neural activation. Here we report on the design and characterization of a new MR-guided FUS transducer for neuromodulation in non-human primates at 650kHz. The array is randomized with 128 elements, radius of curvature 7.2cm, and opening diameter 10.3cm (focal ratio 0.7). Simulations were used to optim…
▽ More
Transcranial focused ultrasound (FUS) is a non-invasive technique for therapy and study of brain neural activation. Here we report on the design and characterization of a new MR-guided FUS transducer for neuromodulation in non-human primates at 650kHz. The array is randomized with 128 elements, radius of curvature 7.2cm, and opening diameter 10.3cm (focal ratio 0.7). Simulations were used to optimize transducer geometry with respect to focus size, grating lobes, and directivity. Focus size and grating lobes during electronic steering were quantified using hydrophone measurements in water and a three-axis stage. A novel combination of optical tracking and acoustic mapping enabled measurement of the 3D pressure distribution in the cortical region of an ex vivo skull to within ~3.5 mm of the surface, and allowed accurate modelling of the experiment via non-homogeneous 3D acoustic simulations. The data demonstrates acoustic focusing beyond the skull bone, with the focus slightly broadened and shifted proximal to the skull. The fabricated design is capable of targeting regions within the S1 sensorimotor cortex of macaques.
△ Less
Submitted 19 December, 2017;
originally announced December 2017.
-
Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes
Authors:
C. A. Aidala,
V. Bailey,
S. Beckman,
R. Belmont,
C. Biggs,
J. Blackburn,
S. Boose,
M. Chiu,
M. Connors,
E. Desmond,
A. Franz,
J. S. Haggerty,
X. He,
M. M. Higdon,
J. Huang,
K. Kauder,
E. Kistenev,
J. LaBounty,
J. G. Lajoie,
M. Lenz,
W. Lenz,
S. Li,
V. R. Loggins,
E. J. Mannel,
T. Majoros
, et al. (25 additional authors not shown)
Abstract:
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the…
▽ More
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\%\oplus~15.5\%/\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\%\oplus 64.9\%/\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.
△ Less
Submitted 16 December, 2018; v1 submitted 5 April, 2017;
originally announced April 2017.
-
Design and Construction of the MicroBooNE Detector
Authors:
MicroBooNE Collaboration,
R. Acciarri,
C. Adams,
R. An,
A. Aparicio,
S. Aponte,
J. Asaadi,
M. Auger,
N. Ayoub,
L. Bagby,
B. Baller,
R. Barger,
G. Barr,
M. Bass,
F. Bay,
K. Biery,
M. Bishai,
A. Blake,
V. Bocean,
D. Boehnlein,
V. D. Bogert,
T. Bolton,
L. Bugel,
C. Callahan,
L. Camilleri
, et al. (215 additional authors not shown)
Abstract:
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, a…
▽ More
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.
△ Less
Submitted 17 January, 2017; v1 submitted 17 December, 2016;
originally announced December 2016.
-
A Prototype Combination TPC Cherenkov Detector with GEM Readout for Tracking and Particle Identification and its Potential Use at an Electron Ion Collider
Authors:
Craig Woody,
Babak Azmoun,
Richard Majka,
Michael Phipps,
Martin Purschke,
Nikolai Smirnov
Abstract:
A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the charge is drifted to a 10x10 cm2 triple GEM detector. The charge is measured on a readout plane consisting of 2x10 mm2 chevron pads which provide a spatial reso…
▽ More
A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the charge is drifted to a 10x10 cm2 triple GEM detector. The charge is measured on a readout plane consisting of 2x10 mm2 chevron pads which provide a spatial resolution ~ 100 microns per point in the chevron direction along with dE/dx information. The Cherenkov portion of the detector consists of a second 10x10 cm2 triple GEM with a photosensitive CsI photocathode on the top layer. This detector measures Cherenkov light produced in the drift gas of the TPC by high velocity particles which are above threshold. CF4 or CF4 mixtures will be used as the drift gas which are highly transparent to UV light and can provide excellent efficiency for detecting Cherenkov photons. The drift gas is also used as the operating gas for both GEM detectors. The prototype detector has been constructed and is currently being tested in the lab with sources and cosmic rays, and additional tests are planned in the future to study the detector in a test beam.
△ Less
Submitted 17 December, 2015; v1 submitted 16 December, 2015;
originally announced December 2015.
-
A Study of a Mini-drift GEM Tracking Detector
Authors:
B. Azmoun,
B. DiRuzza,
A. Franz,
A. Kiselev,
R. Pak,
M. Phipps,
M. L. Purschke,
C. Woody
Abstract:
A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a small drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge…
▽ More
A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a small drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 micron pitch XY strips and the other consisted of 2x10mm2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Applications for large angle tracking detectors at RHIC and EIC are also discussed.
△ Less
Submitted 6 October, 2015;
originally announced October 2015.
-
Performance of a Large-area GEM Detector Read Out with Wide Radial Zigzag Strips
Authors:
Aiwu Zhang,
Vallary Bhopatkar,
Eric Hansen,
Marcus Hohlmann,
Shreeya Khanal,
Michael Phipps,
Elizabeth Starling,
Jessie Twigger,
Kimberly Walton
Abstract:
A 1-meter-long trapezoidal Triple-GEM detector with wide readout strips was tested in hadron beams at the Fermilab Test Beam Facility in October 2013. The readout strips have a special zigzag geometry and run along the radial direction with an azimuthal pitch of 1.37 mrad to measure the azimuthal phi-coordinate of incident particles. The zigzag geometry of the readout reduces the required number o…
▽ More
A 1-meter-long trapezoidal Triple-GEM detector with wide readout strips was tested in hadron beams at the Fermilab Test Beam Facility in October 2013. The readout strips have a special zigzag geometry and run along the radial direction with an azimuthal pitch of 1.37 mrad to measure the azimuthal phi-coordinate of incident particles. The zigzag geometry of the readout reduces the required number of electronic channels by a factor of three compared to conventional straight readout strips while preserving good angular resolution. The average crosstalk between zigzag strips is measured to be an acceptable 5.5%. The detection efficiency of the detector is (98.4+-0.2)%. When the non-linearity of the zigzag-strip response is corrected with track information, the angular resolution is measured to be (193+-3) urad, which corresponds to 14% of the angular strip pitch. Multiple Coulomb scattering effects are fully taken into account in the data analysis with the help of a stand-alone Geant4 simulation that estimates interpolated track errors.
△ Less
Submitted 1 September, 2015; v1 submitted 27 August, 2015;
originally announced August 2015.
-
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
W. Ahmed,
W. Ahmed,
P. Altieri,
R. Aly,
C. Asawatangtrakuldee,
A. Ashfaq,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
P. Barria,
L. Benussi,
V. Bhopatkar,
S. Bianco,
J. Bos,
O. Bouhali,
S. Braibant,
S. Buontempo
, et al. (113 additional authors not shown)
Abstract:
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi…
▽ More
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.
△ Less
Submitted 8 December, 2014; v1 submitted 30 November, 2014;
originally announced December 2014.