-
New Limits on Double Electron Capture of $^{40}$Ca and $^{180}$W
Authors:
G. Angloher,
M. Bauer,
P. Bauer,
I. Bavykina,
A. Bento,
C. Bucci,
L. Canonica,
C. Ciemniak,
X. Defay,
G. Deuter,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
P. Gorla,
A. Gütlein,
D. Hauff,
P. Huff,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kluck,
H. Kraus,
J. -C. Lanfranchi,
J. Loebell
, et al. (31 additional authors not shown)
Abstract:
We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Dependin…
▽ More
We analyzed low-background data from the CRESST-II experiment with a total net exposure of 730 kg days to extract limits on double electron capture processes. We established new limits for $^{40}$Ca with $T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and $T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Depending on the process, these values improve the currently best limits by a factor of $\sim$1.4-30.
△ Less
Submitted 18 August, 2016; v1 submitted 28 April, 2016;
originally announced April 2016.
-
Low-Temperature Light Detectors: Neganov-Luke Amplification and Calibration
Authors:
C. Isaila,
C. Ciemniak,
F. v. Feilitzsch,
A. Gütlein,
J. Kemmer,
T. Lachenmaier,
J. -C. Lanfranchi,
S. Pfister,
W. Potzel,
S. Roth,
M. v. Sivers,
R. Strauss,
W. Westphal,
F. Wiest
Abstract:
The simultaneous measurement of phonons and scintillation light induced by incident particles in a scintillating crystal such as CaWO4 is a powerful technique for the active rejection of background induced by gamma's and beta's and even neutrons in direct Dark Matter searches. However, less than ~1% of the energy deposited in a CaWO4 crystal is detected as light. Thus, very sensitive light detecto…
▽ More
The simultaneous measurement of phonons and scintillation light induced by incident particles in a scintillating crystal such as CaWO4 is a powerful technique for the active rejection of background induced by gamma's and beta's and even neutrons in direct Dark Matter searches. However, less than ~1% of the energy deposited in a CaWO4 crystal is detected as light. Thus, very sensitive light detectors are needed for an efficient event-by-event background discrimination. Due to the Neganov-Luke effect, the threshold of low-temperature light detectors based on semiconducting substrates can be improved significantly by drifting the photon-induced electron-hole pairs in an applied electric field. We present measurements with low-temperature light detectors based on this amplification mechanism. The Neganov-Luke effect makes it possible to improve the signal-to-noise ratio of our light detectors by a factor of ~9 corresponding to an energy threshold of ~21 eV. We also describe a method for an absolute energy calibration using a light-emitting diode.
△ Less
Submitted 17 September, 2012; v1 submitted 1 June, 2011;
originally announced June 2011.
-
Cryogenic Composite Detectors for the Dark Matter Experiments CRESST and EURECA
Authors:
S. Roth,
C. Ciemniak,
C. Coppi,
F. v. Feilitzsch,
A. Guetlein,
C. Isaila,
J. -C. Lanfranchi,
S. Pfister,
W. Potzel,
W. Westphal
Abstract:
Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering off nuclei producing a nuclear recoil with energies up to a few 10 keV with a very low interaction rate of ~10^(-6) events per kg of target material and day in the energy region of interest. The Dark Matter experiment CRESST (Cryogenic Rare…
▽ More
Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering off nuclei producing a nuclear recoil with energies up to a few 10 keV with a very low interaction rate of ~10^(-6) events per kg of target material and day in the energy region of interest. The Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) and the EURECA project (European Underground Rare Event Calorimeter Array) are aimed at the direct detection of WIMPs with the help of very sensitive modularised cryogenic detectors that basically consist of a transition edge sensor (TES) in combination with a massive absorber crystal. In the CRESST experiment the search for coherent WIMP-nucleon scattering events is validated by the detection of two processes. In the scintillating absorber single crystal, CaWO_4, heat (phonons) and scintillation light are produced and detected with two independent cryogenic detectors: a phonon channel and a separate light channel. The development of such cryogenic detectors and the potential ton-scale production are investigated in this paper. To decouple the TES production from the choice of the target material in order to avoid heating cycles of the absorber crystal and to allow pretesting of the TESs, a composite detector design (CDD) for the detector production has been developed and studied. An existing thermal detector model has been extended to the CDD, in order to investigate, understand, and optimize the performance of composite detectors. This extended model, which has been worked out in detail, can be expected to provide a considerable help when tailoring composite detectors to the requirements of various experiments.
△ Less
Submitted 2 October, 2008;
originally announced October 2008.