Recent advancements of the experiment to search for $2K$-capture in $^{124}$Xe using a Large Low-background Proportional Counter
Authors:
O. D. Petrenko,
I. D. Fedorets,
A. M. Gangapshev,
Yu. M. Garilyuk,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing…
▽ More
A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing the sensitivity to $2\nu2K$-decay in $^{124}$Xe at the level of $2\times10^{22}$ from over six years of measurements using a large proportional counter. Analysis of the calibration data, taking into account the new method for correcting the energy release in the detector, made it possible to register events from double $K$ photoionization by a single photon.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
Improving Calibration of the Large Low-Background Proportional Counter
Authors:
O. D. Petrenko,
A. M. Gangapshev,
Yu. M. Garilyuk,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva
Abstract:
The study of low-yield effects requires not only good quality of the original data but also puts high requirements for their processing procedures to increase the efficiency of the selection of useful events. The exploiting of the large cylindrical proportional counter's electrostatic topology allows improving the extrapolation of information about the primary ionization of a multipoint event. Lon…
▽ More
The study of low-yield effects requires not only good quality of the original data but also puts high requirements for their processing procedures to increase the efficiency of the selection of useful events. The exploiting of the large cylindrical proportional counter's electrostatic topology allows improving the extrapolation of information about the primary ionization of a multipoint event. Long-term calibration measurements with an external $^{109}$Cd-source allowed the development of a new method for analyzing the pulse shape from a sizeable proportional counter. Optimized analysis of the current's pulse shape from the electron cloud of primary ionization in the counter improved the resolution and energy calibration. As a result, the efficiency of selecting useful events was increased by 25\%.
△ Less
Submitted 15 October, 2020;
originally announced October 2020.
-
TAU-4 installation intended for long-term monitoring of a half-life value of the $^{212}$Po
Authors:
E. N. Alexeev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
A. M. Gezhaev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
O. D. Petrenko,
S. S. Ratkevich
Abstract:
Description of the TAU-4 installation intended for long-term monitoring of the half-life value $T_{1/2}$ of the $^{212}$Po is presented. Natural thorium used as a source of the mother's chain. The methods of measurement and data processing are described. The comparative results of short test measurements carried out in the ground (680 h) and underground (564 h) laboratories are given. Averaged val…
▽ More
Description of the TAU-4 installation intended for long-term monitoring of the half-life value $T_{1/2}$ of the $^{212}$Po is presented. Natural thorium used as a source of the mother's chain. The methods of measurement and data processing are described. The comparative results of short test measurements carried out in the ground (680 h) and underground (564 h) laboratories are given. Averaged value $T_{1/2}$ =$294.09\pm 0.07$ ns of the $^{212}$Po half-life has been found for the ground level data set similar one for the underground data set. The solar-daily variations with amplitudes $A_{So}=(11.7\pm 5.2)\times10^{-4}$ for the ground data and $A_{So}=(7.5\pm 4.1)\times10^{-4}$ for the underground one were found in a series of $τ$ values.
△ Less
Submitted 12 December, 2018;
originally announced December 2018.
-
The background simulation of experiment for searching of $2\nu2K$ capture in Xe-124
Authors:
V. V. Kazalov,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
V. V. Kuzminov,
S. I. Panasenko,
O. D. Petrenko,
S. S. Ratkevich,
D. A. Tekueva
Abstract:
We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE' setup and discuss the agreement of its output with data. The `2K-CAPTURE' MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both…
▽ More
We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE' setup and discuss the agreement of its output with data. The `2K-CAPTURE' MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both photons and neutrons and tracks them until they either are absorbed. The algorithm proceeds with a detailed simulation of the electronics chain. The MC is tuned using data collected with radioactive calibration source deployed in the internal channel of the installation. The simulation reproduces the energy response of the detector corresponding to distribution of the generated pointwise clusters of a charge of primary ionization in LPC.
△ Less
Submitted 11 December, 2018;
originally announced December 2018.