-
gSeaGen code by KM3NeT: an efficient tool to propagate muons simulated with CORSIKA
Authors:
S. Aiello,
A. Albert,
A. R. Alhebsi,
M. Alshamsi,
S. Alves Garre,
A. Ambrosone,
F. Ameli,
M. Andre,
L. Aphecetche,
M. Ardid,
S. Ardid,
H. Atmani,
J. Aublin,
F. Badaracco,
L. Bailly-Salins,
Z. Bardačová,
B. Baret,
A. Bariego-Quintana,
Y. Becherini,
M. Bendahman,
F. Benfenati,
M. Benhassi,
M. Bennani,
D. M. Benoit,
E. Berbee
, et al. (238 additional authors not shown)
Abstract:
The KM3NeT Collaboration has tackled a common challenge faced by the astroparticle physics community, namely adapting the experiment-specific simulation software to work with the CORSIKA air shower simulation output. The proposed solution is an extension of the open source code gSeaGen, which allows the transport of muons generated by CORSIKA to a detector of any size at an arbitrary depth. The gS…
▽ More
The KM3NeT Collaboration has tackled a common challenge faced by the astroparticle physics community, namely adapting the experiment-specific simulation software to work with the CORSIKA air shower simulation output. The proposed solution is an extension of the open source code gSeaGen, which allows the transport of muons generated by CORSIKA to a detector of any size at an arbitrary depth. The gSeaGen code was not only extended in terms of functionality but also underwent a thorough redesign of the muon propagation routine, resulting in a more accurate and efficient simulation. This paper presents the capabilities of the new gSeaGen code as well as prospects for further developments.
△ Less
Submitted 29 April, 2025; v1 submitted 31 October, 2024;
originally announced October 2024.
-
Nanobeacon: A time calibration device for the KM3NeT neutrino telescope
Authors:
S. Aiello,
A. Albert,
M. Alshamsi,
S. Alves Garre,
Z. Aly,
A. Ambrosone,
F. Ameli,
M. Andre,
G. Androulakis,
M. Anghinolfi,
M. Anguita,
M. Ardid,
S. Ardid,
J. Aublin,
C. Bagatelas,
B. Baret,
S. Basegmez du Pree,
M. Bendahman,
F. Benfenati,
E. Berbee,
A. M. van den Berg,
V. Bertine,
S. Biagi,
M. Boettcher,
M. Bou Cabo
, et al. (216 additional authors not shown)
Abstract:
The KM3NeT Collaboration is currently constructing a multi-site high-energy neutrino telescope in the Mediterranean Sea consisting of matrices of pressure-resistant glass spheres, each holding a set of 31 small-area photomultipliers. The main goals of the telescope are the observation of neutrino sources in the Universe and the measurement of the neutrino oscillation parameters with atmospheric ne…
▽ More
The KM3NeT Collaboration is currently constructing a multi-site high-energy neutrino telescope in the Mediterranean Sea consisting of matrices of pressure-resistant glass spheres, each holding a set of 31 small-area photomultipliers. The main goals of the telescope are the observation of neutrino sources in the Universe and the measurement of the neutrino oscillation parameters with atmospheric neutrinos. Both extraterrestrial and atmospheric neutrinos are detected through the Cherenkov light induced in seawater by charged particles produced in neutrino interactions in the surrounding medium. A relative time synchronization between photomultipliers of the order of 1 ns is needed to guarantee the required angular resolution of the detector. Due to the large detector volumes to be instrumented by KM3NeT, a cost reduction of the different systems is a priority. To this end, the inexpensive Nanobeacon has been designed and developed by the KM3NeT Collaboration to be used for detector time-calibration studies. At present, more than 600 Nanobeacons have been already produced. The characterization of the optical pulse and the wavelength emission profile of the devices are critical for the time calibration. In this paper, the main features of the Nanobeacon design, production and operation, together with the main properties of the light pulse generated are described.
△ Less
Submitted 30 October, 2021;
originally announced November 2021.
-
Influence of image segmentation on one-dimensional fluid dynamics predictions in the mouse pulmonary arteries
Authors:
Mitchel J. Colebank,
L. Mihaela Paun,
M. Umar Qureshi,
Naomi Chesler,
Dirk Husmeier,
Mette S. Olufsen,
Laura Ellwein Fix
Abstract:
Computational fluid dynamics (CFD) models are emerging as tools for assisting in diagnostic assessment of cardiovascular disease. Recent advances in image segmentation has made subject-specific modelling of the cardiovascular system a feasible task, which is particularly important in the case of pulmonary hypertension (PH), which requires a combination of invasive and non-invasive procedures for d…
▽ More
Computational fluid dynamics (CFD) models are emerging as tools for assisting in diagnostic assessment of cardiovascular disease. Recent advances in image segmentation has made subject-specific modelling of the cardiovascular system a feasible task, which is particularly important in the case of pulmonary hypertension (PH), which requires a combination of invasive and non-invasive procedures for diagnosis. Uncertainty in image segmentation can easily propagate to CFD model predictions, making uncertainty quantification crucial for subject-specific models. This study quantifies the variability of one-dimensional (1D) CFD predictions by propagating the uncertainty of network geometry and connectivity to blood pressure and flow predictions. We analyse multiple segmentations of an image of an excised mouse lung using different pre-segmentation parameters. A custom algorithm extracts vessel length, vessel radii, and network connectivity for each segmented pulmonary network. We quantify uncertainty in geometric features by constructing probability densities for vessel radius and length, and then sample from these distributions and propagate uncertainties of haemodynamic predictions using a 1D CFD model. Results show that variation in network connectivity is a larger contributor to haemodynamic uncertainty than vessel radius and length.
△ Less
Submitted 23 April, 2019; v1 submitted 13 January, 2019;
originally announced January 2019.
-
Hemodynamic assessment of pulmonary hypertension in mice: a model based analysis of the disease mechanism
Authors:
M. Umar Qureshi,
Mitchel Colebank,
Mihaela Paun,
Laura Ellwein,
Naomi Chesler,
Mansoor A. Haider,
Nicholas A. Hill,
Dirk Husmeier,
Mette S. Olufsen
Abstract:
This study uses a one dimensional fluid dynamics arterial network model to infer changes in hemodynamic quantities associated with pulmonary hypertension in mice. Data for this study include blood flow and pressure measurements from the main pulmonary artery for 7 control mice with normal pulmonary function and 5 hypertensive mice with hypoxia induced pulmonary hypertension. Arterial dimensions fo…
▽ More
This study uses a one dimensional fluid dynamics arterial network model to infer changes in hemodynamic quantities associated with pulmonary hypertension in mice. Data for this study include blood flow and pressure measurements from the main pulmonary artery for 7 control mice with normal pulmonary function and 5 hypertensive mice with hypoxia induced pulmonary hypertension. Arterial dimensions for a 21 vessel network are extracted from micro-CT images of lungs from a representative control and hypertensive mouse. Each vessel is represented by its length and radius. Fluid dynamic computations are done assuming that the flow is Newtonian, viscous, laminar, and has no swirl. The system of equations is closed by a constitutive equation relating pressure and area, using a linear model derived from stress-strain deformation in the circumferential direction assuming that the arterial walls are thin, and also an empirical nonlinear model. For each dataset, an inflow waveform is extracted from the data, and nominal parameters specifying the outflow boundary conditions are computed from mean values and characteristic time scales extracted from the data. The model is calibrated for each mouse by estimating parameters that minimize the least squares error between measured and computed waveforms. Optimized parameters are compared across the control and the hypertensive groups to characterize vascular remodeling with disease. Results show that pulmonary hypertension is associated with stiffer and less compliant proximal and distal vasculature with augmented wave reflections, and that elastic nonlinearities are insignificant in the hypertensive animal.
△ Less
Submitted 17 May, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.