Measurement of the electric potential and the magnetic field in the shifted analysing plane of the KATRIN experiment
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Behrens,
J. Beisenkötter,
M. Biassoni,
B. Bieringer,
Y. Biondi,
F. Block,
S. Bobien,
M. Böttcher,
B. Bornschein,
L. Bornschein,
T. S. Caldwell,
M. Carminati,
A. Chatrabhuti,
S. Chilingaryan,
B. A. Daniel,
K. Debowski,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards
, et al. (113 additional authors not shown)
Abstract:
The projected sensitivity of the effective electron neutrino-mass measurement with the KATRIN experiment is below 0.3 eV (90 % CL) after five years of data acquisition. The sensitivity is affected by the increased rate of the background electrons from KATRIN's main spectrometer. A special shifted-analysing-plane (SAP) configuration was developed to reduce this background by a factor of two. The co…
▽ More
The projected sensitivity of the effective electron neutrino-mass measurement with the KATRIN experiment is below 0.3 eV (90 % CL) after five years of data acquisition. The sensitivity is affected by the increased rate of the background electrons from KATRIN's main spectrometer. A special shifted-analysing-plane (SAP) configuration was developed to reduce this background by a factor of two. The complex layout of electromagnetic fields in the SAP configuration requires a robust method of estimating these fields. We present in this paper a dedicated calibration measurement of the fields using conversion electrons of gaseous $^\mathrm{83m}$Kr, which enables the neutrino-mass measurements in the SAP configuration.
△ Less
Submitted 9 August, 2024;
originally announced August 2024.
-
Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS
Authors:
P. S. Barbeau,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
E. Conley,
V. da Silva,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
A. Erlandson,
L. Fabris,
M. Febbraro,
A. Galindo-Uribarri,
M. P. Green,
J. Hakenmüller,
M. R. Heath,
S. Hedges,
B. A. Johnson
, et al. (55 additional authors not shown)
Abstract:
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We…
▽ More
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.
-
COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (53 additional authors not shown)
Abstract:
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the…
▽ More
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the transparency and reproducibility of our results. This document describes the contents of the data release as well as guidance on the use of the data.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Physics Opportunities in the ORNL Spallation Neutron Source Second Target Station Era
Authors:
J. Asaadi,
P. S. Barbeau,
B. Bodur,
A. Bross,
E. Conley,
Y. Efremenko,
M. Febbraro,
A. Galindo-Uribarri,
S. Gardiner,
D. Gonzalez-Diaz,
M. P. Green,
M. R. Heath,
S. Hedges,
J. Liu,
A. Major,
D. M. Markoff,
J. Newby,
D. S. Parno,
D. Pershey,
R. Rapp,
D. J. Salvat,
K. Scholberg,
L. Strigari,
B. Suh,
R. Tayloe
, et al. (4 additional authors not shown)
Abstract:
The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maint…
▽ More
The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maintaining quality similar to the FTS source. Furthermore, additional space for ten-tonne scale detectors may be available. We describe here exciting opportunities for neutrino physics, other particle and nuclear physics, and detector development using the FTS and STS neutrino sources.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
The COHERENT Experimental Program
Authors:
D. Akimov,
S. Alawabdeh,
P. An,
A. Arteaga,
C. Awe,
P. S. Barbeau,
C. Barry,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
C. Bock,
B. Bodur,
A. Bolozdynya,
R. Bouabid,
A. Bracho,
J. Browning,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Daughtry,
E. Day
, et al. (106 additional authors not shown)
Abstract:
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies o…
▽ More
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.
△ Less
Submitted 9 April, 2022;
originally announced April 2022.
-
KATRIN: Status and Prospects for the Neutrino Mass and Beyond
Authors:
M. Aker,
M. Balzer,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
M. Biassoni,
B. Bieringer,
F. Block,
S. Bobien,
L. Bombelli,
D. Bormann,
B. Bornschein,
L. Bornschein,
M. Böttcher,
C. Brofferio,
C. Bruch,
T. Brunst,
T. S. Caldwell,
M. Carminati,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
O. Cremonesi
, et al. (137 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a su…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.
△ Less
Submitted 16 June, 2023; v1 submitted 15 March, 2022;
originally announced March 2022.
-
Measuring the electron neutrino mass using the electron capture decay of 163Ho
Authors:
Joel Ullom,
Daniel Schmidt,
Simon Bandler,
Thomas Stevenson,
Mark Croce,
Katrina Koehler,
Matteo De Gerone,
Loredana Gastaldo,
Christian Enss,
Geonbo Kim,
Angelo Nucciotti,
Stefano Ragazzi,
Kyle Leach,
Diana Parno,
Brian Mong,
Josef Frisch,
Christopher Kenney
Abstract:
While the mass differences between neutrino mass states are known, their absolute masses and mass hierarchy have not yet been determined. Determining the mass of neutrinos provides access to physics beyond the Standard Model and the resulting value has implications for the growth of large-scale structure in the universe over cosmic history. Because of the importance of the topic, a number of effor…
▽ More
While the mass differences between neutrino mass states are known, their absolute masses and mass hierarchy have not yet been determined. Determining the mass of neutrinos provides access to physics beyond the Standard Model and the resulting value has implications for the growth of large-scale structure in the universe over cosmic history. Because of the importance of the topic, a number of efforts are already underway to determine the mass of neutrinos including direct kinematic measurements and indirect measurements of astrophysical phenomena that constrain the sum of the mass eigenstates through models of cosmic evolution. Here, we advocate for a collaborative international effort to perform a kinematic determination of the effective electron neutrino mass using calorimetric measurements of the decay of 163Ho. This effort is justified by the success of current experiments using the technique, its high benefit-to-cost ratio, the value of approaches with different systematic errors, and the value of measuring the electron neutrino mass rather than the electron anti-neutrino mass.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Monitoring the SNS basement neutron background with the MARS detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (53 additional authors not shown)
Abstract:
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the…
▽ More
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.
△ Less
Submitted 14 April, 2022; v1 submitted 5 December, 2021;
originally announced December 2021.
-
Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (52 additional authors not shown)
Abstract:
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at t…
▽ More
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.
△ Less
Submitted 6 October, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment
Authors:
M. Aker,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger
, et al. (110 additional authors not shown)
Abstract:
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectromet…
▽ More
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $β$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique.
We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $σ(m_ν^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
A D$_{2}$O detector for flux normalization of a pion decay-at-rest neutrino source
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
E. Day,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (54 additional authors not shown)
Abstract:
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncerta…
▽ More
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.
△ Less
Submitted 25 August, 2021; v1 submitted 19 April, 2021;
originally announced April 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Analysis methods for the first KATRIN neutrino-mass measurement
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
K. Blaum,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
D. Díaz Barrero,
K. Debowski,
M. Deffert,
M. Descher,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (104 additional authors not shown)
Abstract:
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, inte…
▽ More
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, integrating spectrometer for energy analysis. A silicon detector counts $β$ electrons above the energy threshold of the spectrometer, so that a scan of the thresholds produces a precise measurement of the high-energy spectral tail. After detailed theoretical studies, simulations, and commissioning measurements, extending from the molecular final-state distribution to inelastic scattering in the source to subtleties of the electromagnetic fields, our independent, blind analyses allow us to set an upper limit of 1.1 eV on the neutrino-mass scale at a 90\% confidence level. This first result, based on a few weeks of running at a reduced source intensity and dominated by statistical uncertainty, improves on prior limits by nearly a factor of two. This result establishes an analysis framework for future KATRIN measurements, and provides important input to both particle theory and cosmology.
△ Less
Submitted 12 May, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
Development of a $^{83\mathrm{m}}$Kr source for the calibration of the CENNS-10 Liquid Argon Detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri
, et al. (55 additional authors not shown)
Abstract:
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr i…
▽ More
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9$\%$ at the total $^{83\mathrm{m}}$Kr decay energy of 41.5 keV. We performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV
△ Less
Submitted 27 January, 2021; v1 submitted 21 October, 2020;
originally announced October 2020.
-
Characterization of Silicon Drift Detectors with Electrons for the TRISTAN Project
Authors:
S. Mertens,
T. Brunst,
M. Korzeczek,
M. Lebert,
D. Siegmann,
A. Alborini,
K. Altenmüller,
M. Biassoni,
L. Bombelli,
M. Carminati,
M. Descher,
D. Fink,
C. Fiorini,
C. Forstner,
M. Gugiatti,
T. Houdy,
A. Huber,
P. King,
O. Lebeda,
P. Lechner,
V. S. Pantuev,
D. S. Parno,
M. Pavan,
S. Pozzi,
D. C. Radford
, et al. (8 additional authors not shown)
Abstract:
Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede t…
▽ More
Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector's response to electrons on the final sterile neutrino sensitivity.
△ Less
Submitted 16 December, 2020; v1 submitted 14 July, 2020;
originally announced July 2020.
-
Suppression of Penning discharges between the KATRIN spectrometers
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (129 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space b…
▽ More
The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $β$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, "electron catchers" were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.
△ Less
Submitted 17 September, 2020; v1 submitted 21 November, 2019;
originally announced November 2019.
-
Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri,
M. P. Green,
K. S. Hansen
, et al. (53 additional authors not shown)
Abstract:
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitu…
▽ More
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitude of dark matter mass, for dark matter particles produced through vector and leptophobic portals in the absence of other effects beyond the standard model. The characteristic timing structure of a $π$-DAR beam allows a unique opportunity for constraining systematic uncertainties on the standard model background in a time window where signal is not expected, enhancing expected sensitivity. Additionally, we discuss future prospects, further increasing the discovery potential of CEvNS detectors. Such methods would test the calculated thermal dark matter abundance for all couplings $α'\leq1$ within the vector portal model over an order of magnitude of dark matter masses.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
First operation of the KATRIN experiment with tritium
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
W. -J. Baek,
J. Barrett,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun
, et al. (146 additional authors not shown)
Abstract:
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.…
▽ More
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
M. Babutzka,
J. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
T. J. Corona
, et al. (184 additional authors not shown)
Abstract:
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an…
▽ More
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards
, et al. (102 additional authors not shown)
Abstract:
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstr…
▽ More
In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.
△ Less
Submitted 18 March, 2019; v1 submitted 15 March, 2019;
originally announced March 2019.
-
Gamma-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
K. Eitel
, et al. (101 additional authors not shown)
Abstract:
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test th…
▽ More
The KATRIN experiment aims to measure the effective electron antineutrino mass $m_{\overlineν_e}$ with a sensitivity of 0.2 eV/c$^2$ using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the experimental hall, combined with a series of experimental tests that artificially increased or decreased the local gamma flux to the MS, we set an upper limit of 0.006 count/s (90% C.L.) from this mechanism. Our results indicate the effectiveness of the electrostatic and magnetic shielding used to block secondary electrons emitted from the inner surface of the MS.
△ Less
Submitted 10 July, 2019; v1 submitted 1 March, 2019;
originally announced March 2019.
-
The KATRIN Superconducting Magnets: Overview and First Performance Results
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (99 additional authors not shown)
Abstract:
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet sy…
▽ More
The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6~T, adiabatically guide $β$-electrons from the source to the detector within a magnetic flux of 191~Tcm$^2$. A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064~m to 9~m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70$\%$ of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01$\%$ per month at 70$\%$ of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.
△ Less
Submitted 22 June, 2018; v1 submitted 21 June, 2018;
originally announced June 2018.
-
Muon-induced background in the KATRIN main spectrometer
Authors:
K. Altenmüller,
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
S. Bobien,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel
, et al. (109 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of part…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to make a model-independent determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c$^{2}$. It investigates the kinematics of $β$-particles from tritium $β$-decay close to the endpoint of the energy spectrum. Because the KATRIN main spectrometer (MS) is located above ground, muon-induced backgrounds are of particular concern. Coincidence measurements with the MS and a scintillator-based muon detector system confirmed the model of secondary electron production by cosmic-ray muons inside the MS. Correlation measurements with the same setup showed that about $12\%$ of secondary electrons emitted from the inner surface are induced by cosmic-ray muons, with approximately one secondary electron produced for every 17 muon crossings. However, the magnetic and electrostatic shielding of the MS is able to efficiently suppress these electrons, and we find that muons are responsible for less than $17\%$ ($90\%$ confidence level) of the overall MS background.
△ Less
Submitted 13 December, 2018; v1 submitted 30 May, 2018;
originally announced May 2018.
-
Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
Authors:
KATRIN Collaboration,
M. Arenz,
W. -J. Baek,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
R. Berendes,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
W. Buglak,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (105 additional authors not shown)
Abstract:
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such…
▽ More
The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
△ Less
Submitted 3 May, 2018;
originally announced May 2018.
-
LGBT+ Inclusivity in Physics and Astronomy: A Best Practices Guide
Authors:
Nicole Ackerman,
Timothy Atherton,
Adrian Ray Avalani,
Christine A. Berven,
Tanmoy Laskar,
Ansel Neunzert,
Diana S. Parno,
Michael Ramsey-Musolf
Abstract:
We present the second edition of a Best Practices Guide for academic departments and other institutions striving to create more inclusive environments for physicists and astronomers in the LGBT+ community. Our recommendations incorporate new research since the original, 2014 edition, and are designed for anyone who wishes to become aware of -- and help mitigate -- the extra burdens that face membe…
▽ More
We present the second edition of a Best Practices Guide for academic departments and other institutions striving to create more inclusive environments for physicists and astronomers in the LGBT+ community. Our recommendations incorporate new research since the original, 2014 edition, and are designed for anyone who wishes to become aware of -- and help mitigate -- the extra burdens that face members of the LGBT+ community in the physical sciences.
△ Less
Submitted 12 April, 2018;
originally announced April 2018.
-
COHERENT 2018 at the Spallation Neutron Source
Authors:
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
A. Brown,
A. Burenkov,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
J. Daughhetee,
D. J. Dean,
M. del Valle Coello,
J. A. Detwiler,
M. D'Onofrio,
Y. Efremenko,
S. R. Elliott,
E. Erkela,
A. Etenko
, et al. (54 additional authors not shown)
Abstract:
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present th…
▽ More
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT collaboration reported the first detection of CEvNS [Akimov:2017ade] using a CsI[Na] detector. At present the collaboration is deploying four detector technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are located in the neutron-quiet basement of the SNS target building at distances 20-30 m from the SNS neutrino source. The simultaneous measurement in all four COHERENT detector subsystems will test the $N^2$ dependence of the cross section and search for new physics. In addition, COHERENT is measuring neutrino-induced neutrons from charged- and neutral-current neutrino interactions on nuclei in shielding materials, which represent a non-negligible background for CEvNS as well as being of intrinsic interest. The Collaboration is planning as well to look for charged-current interactions of relevance to supernova and weak-interaction physics. This document describes concisely the COHERENT physics motivations, sensitivity, and next plans for measurements at the SNS to be accomplished on a few-year timescale.
△ Less
Submitted 2 April, 2018; v1 submitted 24 March, 2018;
originally announced March 2018.
-
Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (102 additional authors not shown)
Abstract:
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage divid…
▽ More
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
△ Less
Submitted 15 May, 2018; v1 submitted 14 February, 2018;
originally announced February 2018.
-
First transmission of electrons and ions through the KATRIN beamline
Authors:
M. Arenz,
W. -J. Baek,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
A. Berlev,
U. Besserer,
K. Blaum,
T. Bode,
B. Bornschein,
L. Bornschein,
T. Brunst,
N. Buzinsky,
S. Chilingaryan,
W. Q. Choi,
M. Deffert,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel
, et al. (104 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons fr…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.
△ Less
Submitted 7 July, 2018; v1 submitted 12 February, 2018;
originally announced February 2018.
-
Commissioning of the vacuum system of the KATRIN Main Spectrometer
Authors:
M. Arenz,
M. Babutzka,
M. Bahr,
J. P. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
J. Blümer,
L. I. Bodine,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
S. Büsch,
T. H. Burritt,
S. Chilingaryan,
T. J. Corona,
L. De Viveiros,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (125 additional authors not shown)
Abstract:
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong m…
▽ More
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.
△ Less
Submitted 3 March, 2016;
originally announced March 2016.
-
A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab
Authors:
A. Rakhman,
M. Hafez,
S. Nanda,
F. Benmokhtar,
A. Camsonne,
G. D. Cates,
M. M. Dalton,
G. B. Franklin,
M. Friend,
R. W. Michaels,
V. Nelyubin,
D. S. Parno,
K. D. Paschke,
B. P. Quinn,
P. A. Souder,
W. A. Tobias
Abstract:
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maxi…
▽ More
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maximum achieved green power at 5 W IR pump power is 1.74 W with a total conversion efficiency of 34.8\%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7~kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7\%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0\% precision in polarization measurements of an electron beam with energy and current of 1.0~GeV and 50~$μ$A.
△ Less
Submitted 29 March, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
The COHERENT Experiment at the Spallation Neutron Source
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
P. Barton,
B. Becker,
V. Belov,
A. Bolozdynya,
A. Burenkov,
B. Cabrera-Palmer,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
C. Cuesta,
D. Dean,
J. Detwiler,
A. G. Dolgolenko,
Y. Efremenko,
S. R. Elliott,
A. Etenko,
N. Fields,
W. Fox,
A. Galindo-Uribarri,
M. Green
, et al. (42 additional authors not shown)
Abstract:
The COHERENT collaboration's primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils…
▽ More
The COHERENT collaboration's primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the $N^2$ dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.
△ Less
Submitted 3 April, 2016; v1 submitted 29 September, 2015;
originally announced September 2015.
-
Focal-plane detector system for the KATRIN experiment
Authors:
J. F. Amsbaugh,
J. Barrett,
A. Beglarian,
T. Bergmann,
H. Bichsel,
L. I. Bodine,
J. Bonn,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
S. Chilingaryan,
T. J. Corona,
P. J. Doe,
J. A. Dunmore,
S. Enomoto,
J. Fischer,
J. A. Formaggio,
F. M. Fränkle,
D. Furse,
H. Gemmeke,
F. Glück,
F. Harms,
G. C. Harper,
J. Hartmann,
M. A. Howe
, et al. (26 additional authors not shown)
Abstract:
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electro…
▽ More
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
△ Less
Submitted 28 January, 2015; v1 submitted 10 April, 2014;
originally announced April 2014.
-
Dead layer on silicon p-i-n diode charged-particle detectors
Authors:
B. L. Wall,
J. F. Amsbaugh,
A. Beglarian,
T. Bergmann,
H. C. Bichsel,
L. I. Bodine,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
T. J. Corona,
P. J. Doe,
S. Enomoto,
F. Harms,
G. C. Harper,
M. A. Howe,
E. L. Martin,
D. S. Parno,
D. A. Peterson,
L. Petzold,
P. Renschler,
R. G. H. Robertson,
J. Schwarz,
M. Steidl,
T. D. Van Wechel,
B. A. VanDevender
, et al. (3 additional authors not shown)
Abstract:
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-…
▽ More
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by diffusion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.
△ Less
Submitted 7 October, 2013; v1 submitted 4 October, 2013;
originally announced October 2013.
-
The KATRIN Experiment: Status and Outlook
Authors:
D. S. Parno
Abstract:
The KATRIN experiment, presently under construction in Karlsruhe, Germany, will improve on previous laboratory limits on the neutrino mass by a factor of ten. KATRIN will use a high-activity, gaseous T2 source and a very high-resolution spectrometer to measure the shape of the high-energy tail of the tritium-decay beta spectrum. The shape measurement will also be sensitive to new physics, includin…
▽ More
The KATRIN experiment, presently under construction in Karlsruhe, Germany, will improve on previous laboratory limits on the neutrino mass by a factor of ten. KATRIN will use a high-activity, gaseous T2 source and a very high-resolution spectrometer to measure the shape of the high-energy tail of the tritium-decay beta spectrum. The shape measurement will also be sensitive to new physics, including sterile neutrinos and Lorentz violation. This report summarizes recent progress in the experiment.
△ Less
Submitted 19 July, 2013;
originally announced July 2013.
-
Hall A Annual Report 2012
Authors:
S. Riordan,
C. Keppel,
K. Aniol,
J. Annand,
J. Arrington,
T. Averett,
C. Ayerbe Gayoso,
E. Brash,
G. D. Cates,
J. -P. Chen,
E. Chudakov,
D. Flay,
G. B. Franklin,
M. Friedman,
O. Glamazdin,
J. Gomez,
C. Hanretty,
J. -O. Hansen,
C. Hyde,
M. K. Jones,
I. Korover,
J. J. LeRose,
R. A. Lindgren,
N. Liyanage,
E. Long
, et al. (24 additional authors not shown)
Abstract:
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
△ Less
Submitted 18 February, 2013;
originally announced February 2013.
-
Comparison of Modeled and Measured Performance of a GSO Crystal as Gamma Detector
Authors:
D. S. Parno,
M. Friend,
V. Mamyan,
F. Benmokhtar,
A. Camsonne,
G. B. Franklin,
K. Paschke,
B. Quinn
Abstract:
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the…
▽ More
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.
△ Less
Submitted 24 May, 2013; v1 submitted 15 November, 2012;
originally announced November 2012.
-
Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab
Authors:
M. Friend,
D. Parno,
F. Benmokhtar,
A. Camsonne,
M. Dalton,
G. B. Franklin,
V. Mamyan,
R. Michaels,
S. Nanda,
V. Nelyubin,
K. Paschke,
B. Quinn,
A. Rakhman,
P. Souder,
A. Tobias
Abstract:
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crysta…
▽ More
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.
△ Less
Submitted 24 August, 2011; v1 submitted 15 August, 2011;
originally announced August 2011.
-
Preliminary Results from Integrating Compton Photon Polarimetry in Hall A of Jefferson Lab
Authors:
D. Parno,
M. Friend,
F. Benmokhtar,
G. Franklin,
R. Michaels,
S. Nanda,
B. Quinn,
P. Souder
Abstract:
A wide range of nucleon and nuclear structure experiments in Jefferson Lab's Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a Fabry-Perot cavity; by measuring an asymmetry in the integrated signal of the scattered photons detected in a GSO crystal, we can make non-invasive, continuous meas…
▽ More
A wide range of nucleon and nuclear structure experiments in Jefferson Lab's Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a Fabry-Perot cavity; by measuring an asymmetry in the integrated signal of the scattered photons detected in a GSO crystal, we can make non-invasive, continuous measurements of the beam polarization. Our goal is to achieve 1% statistical error within two hours of running. We discuss the design and commissioning of an upgrade to this apparatus, and report preliminary results for experiments conducted at beam energies from 3.5 to 5.9 GeV and photon rates from 5 to 100 kHz.
△ Less
Submitted 23 June, 2011;
originally announced June 2011.