-
Consensus Recommendations for Hyperpolarized [1-13C]pyruvate MRI Multi-center Human Studies
Authors:
Shonit Punwani,
Peder EZ Larson,
Christoffer Laustsen,
Jan VanderMeulen,
Jan Henrik Ardenkjær-Larsen,
Adam W. Autry,
James A. Bankson,
Jenna Bernard,
Robert Bok,
Lotte Bonde Bertelsen,
Jenny Che,
Albert P. Chen,
Rafat Chowdhury,
Arnaud Comment,
Charles H. Cunningham,
Duy Dang,
Ferdia A Gallagher,
Adam Gaunt,
Yangcan Gong,
Jeremy W. Gordon,
Ashley Grimmer,
James Grist,
Esben Søvsø Szocska Hansen,
Mathilde Hauge Lerche,
Richard L. Hesketh
, et al. (17 additional authors not shown)
Abstract:
Magnetic resonance imaging of hyperpolarized (HP) [1-13C]pyruvate allows in-vivo assessment of metabolism and has translated into human studies across diseases at 15 centers worldwide. Consensus on best practice for multi-center studies is required to develop clinical applications. This paper presents the results of a 2-round formal consensus building exercise carried out by experts with HP [1-13C…
▽ More
Magnetic resonance imaging of hyperpolarized (HP) [1-13C]pyruvate allows in-vivo assessment of metabolism and has translated into human studies across diseases at 15 centers worldwide. Consensus on best practice for multi-center studies is required to develop clinical applications. This paper presents the results of a 2-round formal consensus building exercise carried out by experts with HP [1-13C]pyruvate human study experience. Twenty-nine participants from 13 sites brought together expertise in pharmacy methods, MR physics, translational imaging, and data-analysis; with the goal of providing recommendations and best practice statements on conduct of multi-center human studies of HP [1-13C]pyruvate MRI.
Overall, the group reached consensus on approximately two-thirds of 246 statements in the questionnaire, covering 'HP 13C-Pyruvate Preparation', 'MRI System Setup, Calibration, and Phantoms', 'Acquisition and Reconstruction', and 'Data Analysis and Quantification'.
Consensus was present across categories, examples include that: (i) different HP pyruvate preparation methods could be used in human studies, but that the same release criteria have to be followed; (ii) site qualification and quality assurance must be performed with phantoms and that the same field strength must be used, but that the rest of the system setup and calibration methods could be determined by individual sites; (iii) the same pulse sequence and reconstruction methods were preferable, but the exact choice should be governed by the anatomical target; (iv) normalized metabolite area-under-curve (AUC) values and metabolite AUC were the preferred metabolism metrics.
The work confirmed areas of consensus for multi-center study conduct and identified where further research is required to ascertain best practice.
△ Less
Submitted 29 April, 2025;
originally announced April 2025.
-
γ-GeSe:a new hexagonal polymorph from group IV-VI monochalcogenides
Authors:
Sol Lee,
Joong-Eon Jung,
Han-gyu Kim,
Yangjin Lee,
Je Myoung Park,
Jeongsu Jang,
Sangho Yoon,
Arnab Ghosh,
Minseol Kim,
Joonho Kim,
Woongki Na,
Jonghwan Kim,
Hyoung Joon Choi,
Hyeonsik Cheong,
Kwanpyo Kim
Abstract:
The family of group IV-VI monochalcogenides has an atomically puckered layered structure, and their atomic bond configuration suggests the possibility for the realization of various polymorphs. Here, we report the synthesis of the first hexagonal polymorph from the family of group IV-VI monochalcogenides, which is conventionally orthorhombic. Recently predicted four-atomic-thick hexagonal GeSe, so…
▽ More
The family of group IV-VI monochalcogenides has an atomically puckered layered structure, and their atomic bond configuration suggests the possibility for the realization of various polymorphs. Here, we report the synthesis of the first hexagonal polymorph from the family of group IV-VI monochalcogenides, which is conventionally orthorhombic. Recently predicted four-atomic-thick hexagonal GeSe, so-called γ-GeSe, is synthesized and clearly identified by complementary structural characterizations, including elemental analysis, electron diffraction, high-resolution transmission electron microscopy imaging, and polarized Raman spectroscopy. The electrical and optical measurements indicate that synthesized γ-GeSe exhibits high electrical conductivity of 3x10^5 S/m, which is comparable to those of other two-dimensional layered semimetallic crystals. Moreover, γ-GeSe can be directly grown on h-BN substrates, demonstrating a bottom-up approach for constructing vertical van der Waals heterostructures incorporating γ-GeSe. The newly identified crystal symmetry of γ-GeSe warrants further studies on various physical properties of γ-GeSe.
△ Less
Submitted 11 May, 2021;
originally announced May 2021.
-
Performance of the ISS-CREAM calorimeter in a calibration beam test
Authors:
H. G. Zhang,
D. Angelaszek,
M. Copley,
J. H. Han,
H. G. Huh,
Y. S. Hwang,
H. J. Hyun,
J. A. Jeon,
K. C. Kim,
M. H. Kim,
H. J. Kim,
K. Kwashnak,
H. Y. Lee,
J. Lee,
M. H. Lee,
J. Lundquist,
L. Lutz,
A. Malinin,
H. Park,
J. M. Park,
N. Picot-Clemente,
E. S. Seo,
J. Smith,
J. Wu,
Z. Y. Yin
, et al. (1 additional authors not shown)
Abstract:
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers…
▽ More
The Cosmic Ray Energetics And Mass experiment for the International Space Station (ISS-CREAM) was installed on the ISS to measure high-energy cosmic-ray elemental spectra for the charge range $\rm Z=1$ to 26. The ISS-CREAM instrument includes a tungsten scintillating-fiber calorimeter preceded by a carbon target for energy measurements. The carbon target induces hadronic interactions, and showers of secondary particles develop in the calorimeter. The energy deposition in the calorimeter is proportional to the particle energy.
As a predecessor to ISS-CREAM, the balloon-borne CREAM instrument was successfully flown seven times over Antarctica for a cumulative exposure of 191 days. The CREAM calorimeter demonstrated its capability to measure energies of cosmic-ray particles, and the ISS-CREAM calorimeter is expected to have a similar performance. Before the launch, an engineering-unit calorimeter was shipped to CERN for calibration and performance tests. This beam test included position, energy, and angle scans of electron and pion beams together with a high-voltage scan for calibration and characterization. Additionally, an attenuation effect in the scintillating fibers was studied. In this paper, beam test results, including corrections for the attenuation effect, are presented.
△ Less
Submitted 9 June, 2021; v1 submitted 21 April, 2020;
originally announced April 2020.