A gel wax phantom for performance evaluation in diagnostic ultrasound: assessment of image uniformity, geometric accuracy, and diameter of a hyperechoic target
Authors:
Debjani Phani,
Rajasekhar Konduru Varadarajulu,
Arijit Paramanick,
Souradip Paul,
Raghukumar Paramu,
George Zacharia,
Shaiju VS,
Venugopal Muraleedharan,
M. Suheshkumar Singh,
Raghuram Kesavan Nair
Abstract:
Purpose: To develop and validate a phantom for diagnostic ultrasound (US) scanners by embedding targets in gel wax to determine the image uniformity, lateral and axial resolution, and diameter of a stainless-steel disc. Materials and Methods: Acoustic property (AP), which includes the velocity of US (cus), acoustic impedance (Z), and attenuation coefficient in gel wax were determined. The cus, and…
▽ More
Purpose: To develop and validate a phantom for diagnostic ultrasound (US) scanners by embedding targets in gel wax to determine the image uniformity, lateral and axial resolution, and diameter of a stainless-steel disc. Materials and Methods: Acoustic property (AP), which includes the velocity of US (cus), acoustic impedance (Z), and attenuation coefficient in gel wax were determined. The cus, and attenuation coefficient were estimated using the pulse-echo technique. Z was obtained from the product of sample density (\r{ho}) and cus. Two rectangular frames using polytetrafluoroethylene (PTFE) sheets with holes separated by 5, 10, and 20 mm distances were constructed. Nylon filaments and SS-disc (diameter = 16.8 mm) were threaded through the frames and suitably placed in melted gel wax to obtain orthogonal targets. The targets were measured using computerized tomography (CT) and a 2-9 MHz US probe. Results: The AP of gel wax were cus=1418 m/s, \r{ho}= 0.87 g/cm3, Z=1.23 MRayls, attenuation coefficient= 0.88 dB/cm/MHz. The results of US imaging of the targets were compared with their physical sizes and served as baselines for the scanner and probe. The maximum error in distance measurement in the phantom US images was 7.1%, and the phantom volume decreased by 1.8% over 62 weeks. Conclusion: Gel wax can be useful in developing affordable, highly stable, and customizable diagnostic US phantoms that can be implemented widely.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
Acoustic and Ultrasonographic Characterization of Neoprene, Beeswax, and Carbomer-Gel to Mimic Soft-tissue for Ultrasound
Authors:
Debjani Phani,
Rajasekhar K. V.,
Anjali Thomas,
Raghukumar Paramu,
M. Suheshkumar Singh,
Shaiju V. S.,
Venugopal Muraleedharan,
R. K. Nair
Abstract:
Materials with acoustic quantities similar to soft-tissue are essential as tissue-mimicking materials for diagnostic ultrasound (US). Acoustic quantity consists of the sound velocity (cus), acoustic impedance (AI) and attenuation coefficient. In this work, the acoustic quantities of neoprene rubber, beeswax, and Carbomer-gel were determined. The cus and attenuation coefficient were estimated using…
▽ More
Materials with acoustic quantities similar to soft-tissue are essential as tissue-mimicking materials for diagnostic ultrasound (US). Acoustic quantity consists of the sound velocity (cus), acoustic impedance (AI) and attenuation coefficient. In this work, the acoustic quantities of neoprene rubber, beeswax, and Carbomer-gel were determined. The cus and attenuation coefficient were estimated using the pulse-echo technique. The AI was calculated from the product of density and cus. Results were compared with a benchmark based on the International Commission on Radiation Units and Measurements Report-61, Tissue Substitutes, Phantoms and Computational Modelling in Medical Ultrasound. The acceptance criteria were 1.043 g/cm3 (density), 1561 m/s (cus), 1.63 MRayls (AI) and attenuation coefficients within 0.5-0.7 dB/cm/MHz. Computerized tomography (CT) and US images of specimens were obtained to compare with respective images of the human liver (a clinical soft-tissue), to evaluate the similarities in image contrast and echogenicity. Results of neoprene and beeswax were unsatisfactory.However, the acoustic quantities of Carbomer-gel (density 1.03 g/cm3, cus 1567 m/s, and AI 1.61 MRayls, and attenuation coefficient 0.6 dB/cm/MHz) were satisfactory within 2%. Carbomer-gel images could efficiently mimic the contrast and echogenicity of liver images. The uncertainties in cus measurements were 0.36 %, 0.11 % and 0.28 % for neoprene-50, beeswax and C-gel respectively. The attenuation coefficients had uncertainties 4.2 %, 1.9 %, and 2.6 % in these samples. The results of Carbomer-gel could resemble soft-tissue for US. It contains 95 % water, is effortless to prepare, and can support in developing a low-cost phantom for periodic performance evaluation of US scanners and contribute to patient care.
△ Less
Submitted 11 April, 2020;
originally announced April 2020.