-
Joint Reconstruction of Activity and Attenuation in PET by Diffusion Posterior Sampling in Wavelet Coefficient Space
Authors:
Clémentine Phung-Ngoc,
Alexandre Bousse,
Antoine De Paepe,
Hong-Phuong Dang,
Olivier Saut,
Dimitris Visvikis
Abstract:
Attenuation correction (AC) is necessary for accurate activity quantification in positron emission tomography (PET). Conventional reconstruction methods typically rely on attenuation maps derived from a co-registered computed tomography (CT) or magnetic resonance imaging scan. However, this additional scan may complicate the imaging workflow, introduce misalignment artifacts and increase radiation…
▽ More
Attenuation correction (AC) is necessary for accurate activity quantification in positron emission tomography (PET). Conventional reconstruction methods typically rely on attenuation maps derived from a co-registered computed tomography (CT) or magnetic resonance imaging scan. However, this additional scan may complicate the imaging workflow, introduce misalignment artifacts and increase radiation exposure. In this paper, we propose a joint reconstruction of activity and attenuation (JRAA) approach that eliminates the need for auxiliary anatomical imaging by relying solely on emission data. This framework combines wavelet diffusion model (WDM) and diffusion posterior sampling (DPS) to reconstruct fully three-dimensional (3-D) data. Experimental results show our method outperforms maximum likelihood activity and attenuation (MLAA) and MLAA with UNet-based post processing, and yields high-quality noise-free reconstructions across various count settings when time-of-flight (TOF) information is available. It is also able to reconstruct non-TOF data, although the reconstruction quality significantly degrades in low-count (LC) conditions, limiting its practical effectiveness in such settings. This approach represents a step towards stand-alone PET imaging by reducing the dependence on anatomical modalities while maintaining quantification accuracy, even in low-count scenarios when TOF information is available.
△ Less
Submitted 24 May, 2025;
originally announced May 2025.
-
Adaptive Diffusion Models for Sparse-View Motion-Corrected Head Cone-beam CT
Authors:
Antoine De Paepe,
Alexandre Bousse,
Clémentine Phung-Ngoc,
Youness Mellak,
Dimitris Visvikis
Abstract:
Cone-beam computed tomography (CBCT) is a imaging modality widely used in head and neck diagnostics due to its accessibility and lower radiation dose. However, its relatively long acquisition times make it susceptible to patient motion, especially under sparse-view settings used to reduce dose, which can result in severe image artifacts. In this work, we propose a novel framework, joint reconstruc…
▽ More
Cone-beam computed tomography (CBCT) is a imaging modality widely used in head and neck diagnostics due to its accessibility and lower radiation dose. However, its relatively long acquisition times make it susceptible to patient motion, especially under sparse-view settings used to reduce dose, which can result in severe image artifacts. In this work, we propose a novel framework, joint reconstruction and motion estimation (JRM) with adaptive diffusion model (ADM), that simultaneously addresses motion compensation and sparse-view reconstruction in head CBCT. Leveraging recent advances in diffusion-based generative models, our method integrates a wavelet-domain diffusion prior into an iterative reconstruction pipeline to guide the solution toward anatomically plausible volumes while estimating rigid motion parameters in a blind fashion. We evaluate our method on simulated motion-affected CBCT data derived from real clinical computed tomography (CT) volumes. Experimental results demonstrate that JRM-ADM substantially improves reconstruction quality over traditional model-based and learning-based baselines, particularly in highly undersampled scenarios. Our approach enables motion-robust and low-dose CBCT imaging, paving the way for improved clinical viability.
△ Less
Submitted 28 April, 2025; v1 submitted 18 April, 2025;
originally announced April 2025.
-
Solving Blind Inverse Problems: Adaptive Diffusion Models for Motion-corrected Sparse-view 4DCT
Authors:
Antoine De Paepe,
Alexandre Bousse,
Clémentine Phung-Ngoc,
Dimitris Visvikis
Abstract:
Four-dimensional computed tomography (4DCT) is essential for medical imaging applications like radiotherapy, which demand precise respiratory motion representation. Traditional methods for reconstructing 4DCT data suffer from artifacts and noise, especially in sparse-view, low-dose contexts. Motion-corrected (MC) reconstruction is a blind inverse problem that we propose to solve with a novel diffu…
▽ More
Four-dimensional computed tomography (4DCT) is essential for medical imaging applications like radiotherapy, which demand precise respiratory motion representation. Traditional methods for reconstructing 4DCT data suffer from artifacts and noise, especially in sparse-view, low-dose contexts. Motion-corrected (MC) reconstruction is a blind inverse problem that we propose to solve with a novel diffusion model (DM) framework that calibrates an adaptive unknown forward model for motion correction. Furthermore, we used a wavelet diffusion model (WDM) to address computational cost and memory usage. By leveraging the prior probability distribution function (PDF) from the DMs, we enhance the joint reconstruction and motion estimation (JRM) process, improving image quality and preserving resolution. Experiments on extended cardiac-torso (XCAT) phantom data demonstrate that our method outperforms existing techniques, yielding artifact-free, high-resolution reconstructions even under irregular breathing conditions. These results showcase the potential of combining DMs with motion correction to advance sparse-view 4DCT imaging.
△ Less
Submitted 1 February, 2025; v1 submitted 21 January, 2025;
originally announced January 2025.
-
Joint Reconstruction of the Activity and the Attenuation in PET by Diffusion Posterior Sampling: a Feasibility Study
Authors:
Clémentine Phung-Ngoc,
Alexandre Bousse,
Antoine De Paepe,
Hong-Phuong Dang,
Olivier Saut,
Dimitris Visvikis
Abstract:
This study introduces a novel framework for joint reconstruction of the activity and the attenuation (JRAA) in positron emission tomography (PET) using diffusion posterior sampling (DPS). By leveraging diffusion models (DMs), this approach directly addresses activity-attenuation dependencies, mitigating crosstalk issues prevalent in non-time-of-flight (TOF) settings. Experimental evaluations, cond…
▽ More
This study introduces a novel framework for joint reconstruction of the activity and the attenuation (JRAA) in positron emission tomography (PET) using diffusion posterior sampling (DPS). By leveraging diffusion models (DMs), this approach directly addresses activity-attenuation dependencies, mitigating crosstalk issues prevalent in non-time-of-flight (TOF) settings. Experimental evaluations, conducted using 2-dimensional (2-D) XCAT phantom data, demonstrate that DPS significantly outperforms traditional maximum likelihood activity and attenuation (MLAA) methods, producing consistent and high-quality reconstructions even in the absence of TOF information. Ongoing work aims to extend our method to real 3-dimensional (3-D) data with encouraging preliminary findings.
△ Less
Submitted 1 February, 2025; v1 submitted 16 December, 2024;
originally announced December 2024.
-
An ultraviolet laser system for laser cooling and trapping of metastable magnesium
Authors:
A. P. Kulosa,
J. Friebe,
M. P. Riedmann,
A. Pape,
T. W. Wübbena,
D. B. Fim,
S. Rühmann,
K. H. Zipfel,
H. Kelkar,
W. Ertmer,
E. M. Rasel
Abstract:
We report on a reliable laser system for cooling magnesium atoms in the metastable 3P manifold. The three relevant transitions coupling the 3P to the 3D manifold are near 383 nm and seperated by several hundred GHz. The laser system consists of three diode lasers at 766 nm. All lasers are frequency stabilised to a single pre-stabilised transfer cavity. The applied scheme for frequency control grea…
▽ More
We report on a reliable laser system for cooling magnesium atoms in the metastable 3P manifold. The three relevant transitions coupling the 3P to the 3D manifold are near 383 nm and seperated by several hundred GHz. The laser system consists of three diode lasers at 766 nm. All lasers are frequency stabilised to a single pre-stabilised transfer cavity. The applied scheme for frequency control greatly reduces the complexity of operating three lasers combined with resonant frequency doubling stages and provides a high reliability necessary for complex atomic physics experiments.
△ Less
Submitted 29 May, 2012; v1 submitted 18 January, 2012;
originally announced January 2012.
-
Remote frequency measurement of the 1S0-3P1 transition in laser cooled Mg-24
Authors:
J. Friebe,
M. Riedmann,
T. Wübbena,
A. Pape,
H. Kelkar,
W. Ertmer,
O. Terra,
U. Sterr,
S. Weyers,
G. Grosche,
H. Schnatz,
E. M. Rasel
Abstract:
We perform Ramsey-Bordé spectroscopy on laser-cooled magnesium atoms in free fall to measure the 1S0 \rightarrow 3P1 intercombination transition frequency. The measured value of 655 659 923 839 730 (48) Hz is consistent with our former atomic beam measurement (Friebe et al 2008 Phys. Rev. A 78 033830). We improve upon the fractional accuracy of the previous measurement by more than an order of mag…
▽ More
We perform Ramsey-Bordé spectroscopy on laser-cooled magnesium atoms in free fall to measure the 1S0 \rightarrow 3P1 intercombination transition frequency. The measured value of 655 659 923 839 730 (48) Hz is consistent with our former atomic beam measurement (Friebe et al 2008 Phys. Rev. A 78 033830). We improve upon the fractional accuracy of the previous measurement by more than an order of magnitude to 7e-14. The magnesium frequency standard was referenced to a fountain clock of the Physikalisch-Technische Bundesanstalt (PTB) via a phase-stabilized telecom fiber link and its stability was characterized for interrogation times up to 8000 s. The high temperature of the atomic ensemble leads to a systematic shift due to the motion of atoms across the spectroscopy beams. In our regime, this leads to a counterintuitive reduction of residual Doppler shift with increasing resolution. Our theoretical model of the atom-light interaction is in agreement with the observed effect and allows us to quantify its contribution in the uncertainty budget.
△ Less
Submitted 13 December, 2011; v1 submitted 15 July, 2011;
originally announced July 2011.
-
Enrichment of the Superheavy Element Rg in Natural Au
Authors:
A. Marinov,
A. Pape,
D. Kolb,
L. Halicz,
I. Segal,
N. Tepliakov,
Y. Kashiv,
R. Brandt
Abstract:
Based on the observation of the long-lived isotopes 261Rg and 265Rg (Z = 111, t(1/2) >= 10^(8) y) in natural Au, an experiment was performed to enrich Rg in 99.999% Au. 16 mg of Au were heated in vacuum for two weeks at a temperature of 1127 deg. C (63 deg. C above the melting point of Au). The content of 197Au and 261Rg in the residue was studied with high resolution inductively coupled plasma-se…
▽ More
Based on the observation of the long-lived isotopes 261Rg and 265Rg (Z = 111, t(1/2) >= 10^(8) y) in natural Au, an experiment was performed to enrich Rg in 99.999% Au. 16 mg of Au were heated in vacuum for two weeks at a temperature of 1127 deg. C (63 deg. C above the melting point of Au). The content of 197Au and 261Rg in the residue was studied with high resolution inductively coupled plasma-sector field mass spectrometry (ICP-SFMS). The residue of Au was 3x10^(-6) of its original quantity. The recovery of Rg was a few percent. The abundance of Rg compared to Au in the enriched solution was about 2x10^(-6), which is a three to four orders of magnitude enrichment. It is concluded that the evaporation rate of Rg from an Au matrix in vacuum at 63 deg. C above the Au melting point is lower than that of Au. This experiment reinforces our first observation of Rg in a terrestrial material. As before it is concluded that a long-lived isomeric state exists in 261Rg and that it probably belongs to a new class of isomeric states, namely high spin super- or hyperdeformed isomeric states.
△ Less
Submitted 30 November, 2010;
originally announced November 2010.
-
Long-distance remote comparison of ultrastable optical frequencies with 1e-15 instability in fractions of a second
Authors:
Andre Pape,
Osama Terra,
Jan Friebe,
Matthias Riedmann,
Temmo Wübbena,
Ernst-Maria Rasel,
Katharina Predehl,
Thomas Legero,
Burghard Lipphardt,
Harald Schnatz,
Gesine Grosche
Abstract:
We demonstrate a fully optical, long-distance remote comparison of independent ultrastable optical frequencies reaching a short term stability that is superior to any reported remote comparison of optical frequencies. We use two ultrastable lasers, which are separated by a geographical distance of more than 50 km, and compare them via a 73 km long phase-stabilized fiber in a commercial telecommuni…
▽ More
We demonstrate a fully optical, long-distance remote comparison of independent ultrastable optical frequencies reaching a short term stability that is superior to any reported remote comparison of optical frequencies. We use two ultrastable lasers, which are separated by a geographical distance of more than 50 km, and compare them via a 73 km long phase-stabilized fiber in a commercial telecommunication network. The remote characterization spans more than one optical octave and reaches a fractional frequency instability between the independent ultrastable laser systems of 3e-15 in 0.1 s. The achieved performance at 100 ms represents an improvement by one order of magnitude to any previously reported remote comparison of optical frequencies and enables future remote dissemination of the stability of 100 mHz linewidth lasers within seconds.
△ Less
Submitted 17 September, 2010; v1 submitted 28 August, 2009;
originally announced August 2009.
-
Absolute frequency measurement of the magnesium intercombination transition $^1S_0 \to ^3P_1$
Authors:
Jan Friebe,
André Pape,
Matthias Riedmann,
Karsten Moldenhauer,
Tanja Mehlstäubler,
Nils Rehbein,
Christian Lisdat,
Ernst M. Rasel,
Wolfgang Ertmer,
Harald Schnatz,
Burghard Lipphardt,
Gesine Grosche
Abstract:
We report on a frequency measurement of the $(3s^2)^1S_0\to(3s3p)^3P_1$ clock transition of $^{24}$Mg on a thermal atomic beam. The intercombination transition has been referenced to a portable primary Cs frequency standard with the help of a femtosecond fiber laser frequency comb. The achieved uncertainty is $2.5\times10^{-12}$ which corresponds to an increase in accuracy of six orders of magni…
▽ More
We report on a frequency measurement of the $(3s^2)^1S_0\to(3s3p)^3P_1$ clock transition of $^{24}$Mg on a thermal atomic beam. The intercombination transition has been referenced to a portable primary Cs frequency standard with the help of a femtosecond fiber laser frequency comb. The achieved uncertainty is $2.5\times10^{-12}$ which corresponds to an increase in accuracy of six orders of magnitude compared to previous results. The measured frequency value permits the calculation of several other optical transitions from $^1S_0$ to the $^3P_J$-level system for $^{24}$Mg, $^{25}$Mg and $^{26}$Mg. We describe in detail the components of our optical frequency standard like the stabilized spectroscopy laser, the atomic beam apparatus used for Ramsey-Bordé interferometry and the frequency comb generator and discuss the uncertainty contributions to our measurement including the first and second order Doppler effect. An upper limit of $3\times10^{-13}$ in one second for the short term instability of our optical frequency standard was determined by comparison with a GPS disciplined quartz oscillator.
△ Less
Submitted 30 November, 2007;
originally announced November 2007.