-
Contribution of gaseous tritium source rear wall to tritium beta-spectrum in Troitsk nu-mass experiment
Authors:
V. G. Chernov,
V. S. Pantuev
Abstract:
We avaluate the contribution of electron scattering on the rear wall of a windowless gaseous tritium source in the Troitsk nu-mass setup. There is a finite probability for them to scatter, return back and reach the detector. A such additional component distorts the measured electron spectrum. We calculate the scattering on the rear side of the vacuum pipe by the GEANT4 simulation and trace the ele…
▽ More
We avaluate the contribution of electron scattering on the rear wall of a windowless gaseous tritium source in the Troitsk nu-mass setup. There is a finite probability for them to scatter, return back and reach the detector. A such additional component distorts the measured electron spectrum. We calculate the scattering on the rear side of the vacuum pipe by the GEANT4 simulation and trace the electrons back through the magnetic fields to the spectrometer and registration system. The contribution is a few orders of magnitude smaller compared to the original spectrum at the end of the beta-spectrum of 18.6 keV but reaches 2\% at 11 keV. Taking into account this rear wall scattering we can fit well the measured spectrum in search for a sterile neutrino component in the tritium beta decay.
△ Less
Submitted 26 September, 2024;
originally announced September 2024.
-
Calibration of Troitsk nu-mass detector readout electronics by signal digital filters
Authors:
S. B. Abdiganieva,
A. I. Berlev,
M. A. Bochkov,
N. A. Likhovid,
V. S. Pantuev,
S. V. Zadorozhny
Abstract:
We present the results of tuning and calibration of the detector electronics in the signal digitization mode. The goal of the experiment is to search for a possible sterile neutrino signature in tritium beta-decay. The read-out electronics work in direct oscilloscope mode, which requires to optimize time frame the with the goal to minimize noise and energy resolution. We use a 7-pixel silicon drif…
▽ More
We present the results of tuning and calibration of the detector electronics in the signal digitization mode. The goal of the experiment is to search for a possible sterile neutrino signature in tritium beta-decay. The read-out electronics work in direct oscilloscope mode, which requires to optimize time frame the with the goal to minimize noise and energy resolution. We use a 7-pixel silicon drift detector (SDD) and a CMOS charge sensitive preamplifier with very low integration capacitor. Amplifier forms a slowly rising output shape and operates in pulse-reset mode. The 125 MHz ADC digitizes the signals. Using calibration data from Fe55 and Am241 gamma sources we check triangular and trapezoid digital filters to obtain the best noise and energy resolution performance. We are also examining the option to differentiate the output signal.
△ Less
Submitted 9 November, 2022;
originally announced November 2022.
-
Detritiation of the electrostatic spectrometer of Troitsk Nu-mass experiment
Authors:
B. V. Ivanov,
V. S. Pantuev,
A. N. Bukin,
A. A. Semenov,
M. I. Belyakov,
A. I. Belesev,
E. V. Geraskin,
N. A. Ionov,
V. I. Parfenov
Abstract:
The paper describes methods and presents results of the Troitsk Nu-mass experiment spectrometer cleanup, which inner volume (40 m3) and surfaces (160 m2) was contaminated by 4.4 GBq of tritium. The Troitsk Nu-mass experiment of Institute for Nuclear Research of Russian Academy of Sciences, Moscow, is designed to measure the spectrum of electrons from tritium decays in order to search for hypotheti…
▽ More
The paper describes methods and presents results of the Troitsk Nu-mass experiment spectrometer cleanup, which inner volume (40 m3) and surfaces (160 m2) was contaminated by 4.4 GBq of tritium. The Troitsk Nu-mass experiment of Institute for Nuclear Research of Russian Academy of Sciences, Moscow, is designed to measure the spectrum of electrons from tritium decays in order to search for hypothetical particles - sterile neutrinos. As a result of equipment failure, the spectrometer internal volume was contaminated with tritium. The contamination made measurements impossible and the research program stopped. The methods of vacuum extraction, hydrogen soaks, and water vapour soaks were used for cleanup. As a result of detritiation, the background level of the main detector of the Troitsk Nu-mass spectrometer decreased by more than 10 times, which made it possible to resume work. The results are consistent with the data obtained earlier for volumes in normal conditions in the air and can be used for planning work on detritiation of similar installations.
△ Less
Submitted 9 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Characterization of Silicon Drift Detectors with Electrons for the TRISTAN Project
Authors:
S. Mertens,
T. Brunst,
M. Korzeczek,
M. Lebert,
D. Siegmann,
A. Alborini,
K. Altenmüller,
M. Biassoni,
L. Bombelli,
M. Carminati,
M. Descher,
D. Fink,
C. Fiorini,
C. Forstner,
M. Gugiatti,
T. Houdy,
A. Huber,
P. King,
O. Lebeda,
P. Lechner,
V. S. Pantuev,
D. S. Parno,
M. Pavan,
S. Pozzi,
D. C. Radford
, et al. (8 additional authors not shown)
Abstract:
Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede t…
▽ More
Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector's response to electrons on the final sterile neutrino sensitivity.
△ Less
Submitted 16 December, 2020; v1 submitted 14 July, 2020;
originally announced July 2020.
-
First measeurements in search for keV-sterile neutrino in tritium beta-decay by Troitsk nu-mass experiment
Authors:
J. N. Abdurashitov,
A. I. Belesev,
V. G. Chernov,
E. V. Geraskin,
A. A. Golubev,
P. V. Grigorieva,
G. A. Koroteev,
N. A. Likhovid,
A. A. Nozik,
V. S. Pantuev,
V. I. Parfenov,
A. K. Skasyrskaya,
I. I. Tkachev,
S. V. Zadorozhny
Abstract:
We present the first measurements of tritium beta-decay spectrum in the electron energy range 16-18.6 keV. The goal is to find distortions which may correspond to the presence of a heavy sterile neutrinos. A possible contribution of this kind would manifest itself as a kink in the spectrum with a similar shape but with end point shifted by the value of a heavy neutrino mass. We set a new upper lim…
▽ More
We present the first measurements of tritium beta-decay spectrum in the electron energy range 16-18.6 keV. The goal is to find distortions which may correspond to the presence of a heavy sterile neutrinos. A possible contribution of this kind would manifest itself as a kink in the spectrum with a similar shape but with end point shifted by the value of a heavy neutrino mass. We set a new upper limits to the neutrino mixing matrix element U^2_{e4} which improve existing limits by a factor from 2 to 5 in the mass range 0.1-2 keV.
△ Less
Submitted 21 June, 2017; v1 submitted 31 March, 2017;
originally announced March 2017.
-
Electron scattering on hydrogen and deuterium molecules at 14-25 keV by the "Troitsk nu-mass" experiment
Authors:
D. N. Abdurashitov,
A. I. Belesev,
V. G. Chernov,
E. V. Geraskin,
A. A. Golubev,
G. A. Koroteev,
N. A. Likhovid,
A. A. Nozik,
V. S. Pantuev,
V. I. Parfenov,
A. K. Skasyrskaya,
S. V. Zadorozhny
Abstract:
We've performed precise measurements of electron scattering on molecular hydrogen and deuterium by using the "Troitsk nu-mass" setup. Electrons were generated by the electron gun with an energy line width better than 0.3 eV. The electron energies were 14, 17, 18.7, 19 and 25 keV. The windowless gaseous tritium source (WGTS) was filled by hydrogen isotopes and served as a target. The total column d…
▽ More
We've performed precise measurements of electron scattering on molecular hydrogen and deuterium by using the "Troitsk nu-mass" setup. Electrons were generated by the electron gun with an energy line width better than 0.3 eV. The electron energies were 14, 17, 18.7, 19 and 25 keV. The windowless gaseous tritium source (WGTS) was filled by hydrogen isotopes and served as a target. The total column density was adjusted to form a length of 0.35--0.7 of the electron mean free path. The integral spectrum of scattered electrons was measured by the electrostatic spectrometer with a magnetic adiabatic collimation and relative energy resolution 8.3 10^{-5}. As a result, the shapes of molecular excitation and ionization spectra were extracted for both isotopes. We did not find any difference between hydrogen and deuterium targets. The relative energy dependence was extracted too.
△ Less
Submitted 14 March, 2016;
originally announced March 2016.
-
The role of electron scattering from registration detector in a MAC-E type spectrometer
Authors:
P. V. Grigorieva,
A. A. Nozik,
V. S. Pantuev,
A. K. Skasyrskaya
Abstract:
There is a proposal to search for a sterile neutrino in a few keV mass range by the "Troitsk nu-mass" facility. In order to estimate sterile neutrino mixing one needs to make precision spectrum measurements well below the endpoint using the existing electrostatic spectrometer with a magnetic adiabatic collimation, or MAC-E filter. The expected signature will be a kink in the electron energy spectr…
▽ More
There is a proposal to search for a sterile neutrino in a few keV mass range by the "Troitsk nu-mass" facility. In order to estimate sterile neutrino mixing one needs to make precision spectrum measurements well below the endpoint using the existing electrostatic spectrometer with a magnetic adiabatic collimation, or MAC-E filter. The expected signature will be a kink in the electron energy spectrum in tritium beta-decay. In this article we consider the systematic effect of electron backscattering on the detector used in the spectrometer. For this purpose we provide a set of Monte-Carlo simulation results of electron backscattering on a silicon detector with a thin golden window with realistic electric and magnetic fields in the spectrometer. We have found that the probability of such an effect reaches up to 20-30\%. The scattered electron could be reflected backwards to the detector by electrostatic field or by magnetic mirror. There is also a few percent probability to escape from the spectrometer through its entrance. A time delay between the scattering moment on the detector and the return of the reflected electron can reach a couple of microseconds in the Troitsk spectrometer. Such estimations are critical for the planning upgrades of the detector and the registration electronics.
△ Less
Submitted 19 November, 2015;
originally announced November 2015.
-
The current status of "Troitsk nu-mass" experiment in search for sterile neutrino
Authors:
D. N. Abdurashitov,
A. I. Belesev,
A. I. Berlev,
V. G. Chernov,
E. V. Geraskin,
A. A. Golubev,
G. A. Koroteev,
N. A. Likhovid,
A. A. Lokhov,
A. I. Markin,
A. A. Nozik,
V. S. Pantuev,
V. I. Parfenov,
A. K. Skasyrskaya,
N. A. Titov,
I. I. Tkachev,
F. V. Tkachov,
S. V. Zadorozhny
Abstract:
We propose a new experiment to search for a sterile neutrino in a few keV mass range at the "Troitsk nu-mass" facility. The expected signature corresponds to a kink in the electron energy spectrum in tritium beta-decay. The new goal compared to our previous experiment will be precision spectrum measurements well below end point. The experimental installation consists of a windowless gaseous tritiu…
▽ More
We propose a new experiment to search for a sterile neutrino in a few keV mass range at the "Troitsk nu-mass" facility. The expected signature corresponds to a kink in the electron energy spectrum in tritium beta-decay. The new goal compared to our previous experiment will be precision spectrum measurements well below end point. The experimental installation consists of a windowless gaseous tritium source and a high resolution electromagnetic spectrometer. We estimate that the current bounds on the sterile neutrino mixing parameter can be improved by an order of magnitude in the mass range under 5 keV without major upgrade of the existing equipment. Upgrades of calibration, data acquisition and high voltage systems will allow to improve the bounds by another order of magnitude.
△ Less
Submitted 11 November, 2015; v1 submitted 2 April, 2015;
originally announced April 2015.