A hybrid structure gaseous detector for ion backflow suppression*
Authors:
YuLian Zhang,
HuiRong Qi,
BiTao Hu,
Hai-Yun Wang,
Qun Ou-Yang,
Yuan-Bo Chan,
Jian Zhang,
Zhi-Wen Wen
Abstract:
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a Micromegas detector. Both Micromegas and GEM have the capability to naturally reduce most of the ions produced in the amplification region. The GEM also acts as t…
▽ More
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a Micromegas detector. Both Micromegas and GEM have the capability to naturally reduce most of the ions produced in the amplification region. The GEM also acts as the preamplifer device and increases gas gain together with the Micromegas. Feasibility tests of the hybrid detector are performed using an ${}^{55}$Fe X-ray source. The energy resolution is better than 27% for 5.9 keV X-rays. It is demonstrated that a backflow ratio better than 0.2% can be reached in the hybrid readout structure at a gain of 5000.
△ Less
Submitted 31 March, 2017; v1 submitted 26 September, 2016;
originally announced September 2016.
-
Development of a two-dimensional imaging GEM detector using the resistive anode readout method with $6\times6$ cells
Authors:
Xu-Dong Ju,
Ming-Yi Dong,
Chuan-Xing Zhou,
Jing Dong,
Yu-Bin Zhao,
Hong-Yu Zhang,
Hui-Rong Qi,
Qun Ou-Yang
Abstract:
We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists of $6\times6$ cells with the cell size $6~\mathrm{mm}\times6~\mathrm{mm}$. New electronics and DAQ system are used to process the signals from the 49 readout channels. The detector has been tested by using the X-ray tube (8~keV). The spatial resolution of the dete…
▽ More
We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists of $6\times6$ cells with the cell size $6~\mathrm{mm}\times6~\mathrm{mm}$. New electronics and DAQ system are used to process the signals from the 49 readout channels. The detector has been tested by using the X-ray tube (8~keV). The spatial resolution of the detector is about $103.46~\mathrm{μm}$ with the detector response part about $66.41~\mathrm{μm}$. The nonlinearity of the detector is less than $1.5\%$. A quite good two dimensional imaging capability is achieved as well. The performances of the detector show the prospect of the resistive anode readout method for the large readout area imaging detectors.
△ Less
Submitted 5 September, 2016; v1 submitted 14 August, 2016;
originally announced August 2016.
-
Track segment finding with CGEM-IT and matching to tracks in ODC
Authors:
Huai-Min Liu,
Ling-Hui Wu,
Liang-Liang Wang,
Liao-Yuan Dong,
Ming-Yi Dong,
Qing-Lei Xiu,
Qun Ou-Yang,
Wei-Dong Li,
Wei-Guo,
Li Xu-Dong Ju,
Xin-Hua Sun,
Ye Yuan,
Yao Zhang
Abstract:
The relative differences in coordinates of Cylindrical-Gas-Electron-Multiplier-Detector-based Inner Tracker (CGEM-IT) clusters are studied to search for track segments in CGEM-IT. With the full simulation of single muon track samples, clear patterns are found and parameterized for the correct cluster combinations. The cluster combinations satisfying the patterns are selected as track segment candi…
▽ More
The relative differences in coordinates of Cylindrical-Gas-Electron-Multiplier-Detector-based Inner Tracker (CGEM-IT) clusters are studied to search for track segments in CGEM-IT. With the full simulation of single muon track samples, clear patterns are found and parameterized for the correct cluster combinations. The cluster combinations satisfying the patterns are selected as track segment candidates in CGEM-IT with an efficiency higher than 99%. The parameters of the track segments are obtained by a helix fitting. Some chi-squared quantities, evaluating the differences in track parameters between the track segments in CGEM-IT and the tracks found in Outer-Drift-Chamber (ODC), are calculated and used to match them. Proper chi-squared requirements are determined as a function of transverse momentum and the matching efficiency is found reasonable.
△ Less
Submitted 11 April, 2016;
originally announced April 2016.
-
Study of cluster reconstruction and track fitting algorithms for CGEM-IT at BESIII
Authors:
Yue Guo,
Liang-Liang Wang,
Xu-Dong Ju,
Ling-Hui Wu,
Qing-Lei Xiu,
Hai-Xia Wang,
Ming-Yi Dong,
Jing-Ran Hu,
Wei-Dong Li,
Wei-Guo Li,
Huai-Min Liu,
Qun Ou-Yang,
Xiao-Yan Shen,
Ye Yuan,
Yao Zhang
Abstract:
Considering the aging effects of existing Inner Drift Chamber (IDC) of BES\uppercase\expandafter{\romannumeral3}, a GEM based inner tracker is proposed to be designed and constructed as an upgrade candidate for IDC. This paper introduces a full simulation package of CGEM-IT with a simplified digitization model, describes the development of the softwares for cluster reconstruction and track fitting…
▽ More
Considering the aging effects of existing Inner Drift Chamber (IDC) of BES\uppercase\expandafter{\romannumeral3}, a GEM based inner tracker is proposed to be designed and constructed as an upgrade candidate for IDC. This paper introduces a full simulation package of CGEM-IT with a simplified digitization model, describes the development of the softwares for cluster reconstruction and track fitting algorithm based on Kalman filter method for CGEM-IT. Preliminary results from the reconstruction algorithms are obtained using a Monte Carlo sample of single muon events in CGEM-IT.
△ Less
Submitted 10 April, 2015;
originally announced April 2015.
-
Study on the effect of humidity and dust on leakage current of bulk micro-MEGAS detector
Authors:
Bo Wang,
Yu-lian Zhang,
Hui-Rong Qi,
Jing Liu,
Xin-Shuai Zhang,
Tian-Chong Zhang,
Fu-Ting Yi,
Qun Ou-Yang,
Yuan-Bo Chen
Abstract:
In this paper, the effect of humidity and dust trapped in avalanche region on leakage current of bulk micro-MEGAS detector is studied. Pyralux PC1025 layers of DuPont are introduced in bulk technique and micro-MEGAS detector with pillars of 300μm in diameter is fabricated. Leakage current is tested in air with different humidity. Silicon carbide powder and PMMA (polymethyl methacrylate) powder are…
▽ More
In this paper, the effect of humidity and dust trapped in avalanche region on leakage current of bulk micro-MEGAS detector is studied. Pyralux PC1025 layers of DuPont are introduced in bulk technique and micro-MEGAS detector with pillars of 300μm in diameter is fabricated. Leakage current is tested in air with different humidity. Silicon carbide powder and PMMA (polymethyl methacrylate) powder are added as dust to avalanche region. Leakage current with and without powder is tested in air and results are depicted in the same figure. Test results indicate that leakage current increases with both storage humidity and test humidity, and also increases when powder is introduced in avalanche region.
△ Less
Submitted 25 September, 2013;
originally announced September 2013.