The P$^3$ Experiment: A Positron Source Demonstrator for Future Lepton Colliders
Authors:
Nicolas Vallis,
Paolo Craievich,
Mattia Schär,
Riccardo Zennaro,
Bernard Auchmann,
Hans-Heinrich Braun,
Maria Ilaria Besana,
Michal Duda,
Reto Fortunati,
Henrique Garcia Rodrigues,
Dominique Hauenstein,
Rasmus Ischebeck Rasmus,
Pavle Juranić,
Jaap Kosse,
Fabio Marcellini,
Thomas Uli Michlmayr,
Stefan Müller,
Marco Pedrozzi,
Renzo Rotundo,
Gian Luca Orlandi,
Mike Seidel,
Nick Parsifal Strohmaier,
Mariia Zykova
Abstract:
The PSI Positron Production (P$^3$ or P-cubed) experiment is a demonstrator for a e+ source and capture system with potential to improve the state-of-the-art e+ yield by an order of magnitude. The experiment is driven by the FCC-ee injector study and will be hosted in the SwissFEL facility at the Paul Scherrer Institute in Switzerland. This paper is an overview of the P$^3$ design at an advanced s…
▽ More
The PSI Positron Production (P$^3$ or P-cubed) experiment is a demonstrator for a e+ source and capture system with potential to improve the state-of-the-art e+ yield by an order of magnitude. The experiment is driven by the FCC-ee injector study and will be hosted in the SwissFEL facility at the Paul Scherrer Institute in Switzerland. This paper is an overview of the P$^3$ design at an advanced stage, with a particular emphasis on a novel e+ capture system and its associated beam dynamics. Additionally, a concept for the experiment diagnostics is presented, as well as the key points of the ongoing installation works.
△ Less
Submitted 1 September, 2023; v1 submitted 31 August, 2023;
originally announced August 2023.
-
Absolute and non-invasive determination of the electron bunch length in a Free Electron Laser using a Bunch Compressor Monitor
Authors:
Gian Luca Orlandi
Abstract:
In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs). The bunch-length dependent signal of a BCM results from the detection and integration - over a given frequency band - of the temporal coherent enhancement of the radiation spectral energy emitted by the electron beam while e…
▽ More
In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs). The bunch-length dependent signal of a BCM results from the detection and integration - over a given frequency band - of the temporal coherent enhancement of the radiation spectral energy emitted by the electron beam while experiencing a longitudinal compression. In this letter, we present a method that permits to express the relative variation of the bunch length as a function of the relative statistical fluctuations of the BCM signal and charge. Furthermore, in the case of a BCM equipped with two detectors simultaneously operating in two distinct wavelength bands, the method permits an absolute determination of the bunch length. The presented method is beneficial to a FEL since it permits to tune the machine compression feedback with respect to the measured bunch length instead of the bunch-length dependent signal. In a CW-linac driven FEL, it can offer the precious opportunity to implement a fully non-invasive and absolute diagnostics of the bunch length.
△ Less
Submitted 26 May, 2023;
originally announced May 2023.
-
Electron beam transverse phase space tomography using nanofabricated wire scanners with submicrometer resolution
Authors:
Benedikt Hermann,
Vitaliy A. Guzenko,
Orell R. Hürzeler,
Adrian Kirchner,
Gian Luca Orlandi,
Eduard Prat,
Rasmus Ischebeck
Abstract:
Characterization and control of the transverse phase space of high-brightness electron beams is required at free-electron lasers or electron diffraction experiments for emittance measurement and beam optimization as well as at advanced acceleration experiments. Dielectric laser accelerators or plasma accelerators with external injection indeed require beam sizes at the micron level and below. We p…
▽ More
Characterization and control of the transverse phase space of high-brightness electron beams is required at free-electron lasers or electron diffraction experiments for emittance measurement and beam optimization as well as at advanced acceleration experiments. Dielectric laser accelerators or plasma accelerators with external injection indeed require beam sizes at the micron level and below. We present a method using nano-fabricated metallic wires oriented at different angles to obtain projections of the transverse phase space by scanning the wires through the beam and detecting the amount of scattered particles. Performing this measurement at several locations along the waist allows assessing the transverse distribution at different phase advances. By applying a novel tomographic algorithm the transverse phase space density can be reconstructed. Measurements at the ACHIP chamber at SwissFEL confirm that the transverse phase space of micrometer-sized electron beams can be reliably characterized using this method.
△ Less
Submitted 16 February, 2021;
originally announced February 2021.
-
Nano-Fabricated Free-Standing Wire-Scanners with Sub-Micrometer Resolution
Authors:
G. L. Orlandi,
C. David,
E. Ferrari,
V. A. Guzenko,
B. Hermann,
R. Ischebeck,
E. Prat,
M. Ferianis,
G. Penco,
M. Veronese,
N. Cefarin,
S. Dal Zilio,
M. Lazzarino
Abstract:
Diagnostics of the beam transverse profile with ever more demanding spatial resolution is required by the progress on novel particle accelerators - such as laser and plasma driven accelerators - and by the stringent beam specifications of the new generation of X-ray facilities. In a linac driven Free-Electron-Laser (FEL), the spatial resolution constraint joins with the further requirement for the…
▽ More
Diagnostics of the beam transverse profile with ever more demanding spatial resolution is required by the progress on novel particle accelerators - such as laser and plasma driven accelerators - and by the stringent beam specifications of the new generation of X-ray facilities. In a linac driven Free-Electron-Laser (FEL), the spatial resolution constraint joins with the further requirement for the diagnostics to be minimally invasive in order to protect radiation sensitive components - such as the undulators - and to preserve the lasing mechanism. As for high resolution measurements of the beam transverse profile in a FEL, wire-scanners (WS) are the top-ranked diagnostics. Nevertheless, conventional WS consisting of a metallic wire (beam-probe) stretched onto a frame (fork) can provide at best a rms spatial resolution at the micrometer scale along with an equivalent surface of impact on the electron beam. In order to improve the spatial resolution of a WS beyond the micrometer scale along with the transparency to the lasing, PSI and FERMI are independently pursuing the technique of the nano-lithography to fabricate a free-standing and sub-micrometer wide WS beam-probe fully integrated into a fork. Free-standing WS with a geometrical resolution of about 250 nm have been successfully tested at SwissFEL where low charge electron beams with a vertical size of 400-500 nm have been characterized. Further experimental tests carried out at SwissFEL at the nominal beam charge of 200 pC confirmed the resilience to the heat-loading of the nano-fabricated WS. In this work, details on the nano-fabrication of free-standing WS as well as results of the electron-beam characterization are presented.
△ Less
Submitted 30 January, 2020; v1 submitted 20 August, 2019;
originally announced August 2019.
-
Bunch Length and Energy Measurements in the Bunch-Compressor of a Free-Electron-Laser
Authors:
G. L. Orlandi,
R. Xue,
H. Brands,
F. Frei,
Z. Geng,
S. Bettoni
Abstract:
At SwissFEL, a fully non-invasive characterization of the beam energy distribution can be performed by means of a Synchrotron-Radiation-Monitor (SRM) imaging in the visible the transverse profile of the electron beam in a magnetic chicane. Under conditions of off-crest acceleration in the SwissFEL injector, according to a first order Taylor series expansion, the distribution of the relative energy…
▽ More
At SwissFEL, a fully non-invasive characterization of the beam energy distribution can be performed by means of a Synchrotron-Radiation-Monitor (SRM) imaging in the visible the transverse profile of the electron beam in a magnetic chicane. Under conditions of off-crest acceleration in the SwissFEL injector, according to a first order Taylor series expansion, the distribution of the relative energy of the electron beam can be linearly expressed as a function of the distribution of the electron longitudinal coordinates via the coefficient of the rf induced beam energy chirp. It is hence possible to express the distribution of the electron longitudinal coordinates at the entrance of the magnetic chicane of SwissFEL as a function of the distribution of the dispersed electron trajectories in the horizontal plane of the magnetic chicane. Machine parameters and instrument data at SwissFEL can be beam-synchronously acquired. A shot-by-shot correlation between the analysis results of the SRM camera images and the linear coefficient of the beam energy chirp resulting from the rf parameters of the injector can be hence established. Finally, taking into account the compression factor of the magnetic chicane, the electron bunch length at the exit of the magnetic chicane can be expressed as a function of the horizontal size of the electron beam imaged by the SRM. Bunch-length measurements performed by means of the SRM in the first magnetic chicane of SwissFEL will be presented.
△ Less
Submitted 20 May, 2019;
originally announced May 2019.
-
Generation and Measurement of Sub-Micrometer Relativistic Electron Beams
Authors:
Simona Borrelli,
Gian Luca Orlandi,
Martin Bednarzik,
Christian David,
Eugenio Ferrari,
Vitaliy A. Guzenko,
Cigdem Ozkan-Loch,
Eduard Prat,
Rasmus Ischebeck
Abstract:
The generation of low-emittance electron beams has received significant interest in recent years. Driven by the requirements of X-ray free electron lasers, the emittance of photocathode injectors has been reduced significantly, with a corresponding increase in beam brightness. At the same time, this has put increasingly stringent requirements on the instrumentation to measure the beam size. These…
▽ More
The generation of low-emittance electron beams has received significant interest in recent years. Driven by the requirements of X-ray free electron lasers, the emittance of photocathode injectors has been reduced significantly, with a corresponding increase in beam brightness. At the same time, this has put increasingly stringent requirements on the instrumentation to measure the beam size. These requirements are even more stringent for novel accelerator developments, such as laser-driven accelerators based on dielectric structures or on a plasma, or for linear colliders at the energy frontier. We present here the generation and measurement of a sub-micrometer electron beam, at a particle energy of 330 MeV, and a bunch charge below 1 pC. An electron beam optics with a beta-function of a few millimeters in the vertical plane had been set up. The beam was characterized through a wire scanner that employs a 1 um wide metallic structure fabricated using the electron beam lithography on a silicon nitride membrane. The smallest (rms) beam size presented here is less than 500 nm.
△ Less
Submitted 11 April, 2018;
originally announced April 2018.
-
Design and Test of Wire-Scanners for SwissFEL
Authors:
G. L. Orlandi,
M. Baldinger,
H. Brands,
P. Heimgartner,
R. Ischebeck,
A. Kammerer,
F. Löhl,
R. Lüscher,
P. Mohanmurthy,
C. Ozkan,
V. Schlott,
L. Schulz,
B. Rippstein,
C. Seiler,
S. Trovati,
P. Valitutti,
D. Zimoch
Abstract:
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam tra…
▽ More
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam transverse profile without suffering from possible micro-bunching of the electron beam. The main aspects of the design, laboratory characterization and beam-test of the SwissFEL wire-scanner prototype will be discussed.
△ Less
Submitted 1 November, 2016;
originally announced November 2016.
-
Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility
Authors:
T. Schietinger,
M. Pedrozzi,
M. Aiba,
V. Arsov,
S. Bettoni,
B. Beutner,
M. Calvi,
P. Craievich,
M. Dehler,
F. Frei,
R. Ganter,
C. P. Hauri,
R. Ischebeck,
Y. Ivanisenko,
M. Janousch,
M. Kaiser,
B. Keil,
F. Löhl,
G. L. Orlandi,
C. Ozkan Loch,
P. Peier,
E. Prat,
J. -Y. Raguin,
S. Reiche,
T. Schilcher
, et al. (70 additional authors not shown)
Abstract:
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chican…
▽ More
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.
△ Less
Submitted 27 October, 2016; v1 submitted 8 June, 2016;
originally announced June 2016.
-
Covariance and Causality in the Transition Radiation of an Electron Bunch
Authors:
Gian Luca Orlandi
Abstract:
A theoretical model of the transition radiation (TR) emission of an N electron bunch must comply with the covariance and the temporal-causality principles. A charge-density-like covariance must indeed imprint the formal expression of the TR energy spectrum. A causality relation must constrain the emission phases of the radiation pulse to the temporal sequence of the N electron collisions onto the…
▽ More
A theoretical model of the transition radiation (TR) emission of an N electron bunch must comply with the covariance and the temporal-causality principles. A charge-density-like covariance must indeed imprint the formal expression of the TR energy spectrum. A causality relation must constrain the emission phases of the radiation pulse to the temporal sequence of the N electron collisions onto the metallic screen. Covariance and causality are the two faces of the same coin: failing in implementing one of the two constraints into the model necessarily implies betraying the other one. The main formal aspects of a covariance and causality consistent formulation of the TR energy spectrum of an N electron beam will be here described with reference to the case of a radiator surface with an arbitrary size.
△ Less
Submitted 4 June, 2013;
originally announced June 2013.
-
Covariant Formulation of the Transition Radiation Energy Spectrum of an Electron Beam at a Normal Angle of Incidence onto a Round Metallic Screen
Authors:
Gian Luca Orlandi
Abstract:
In the transition radiation emission from a N electron bunch hitting at a normal angle of incidence a metallic screen, the transverse and the longitudinal spatial coordinates of the electron bunch play different roles in determining the N single electron radiation field amplitudes and their relative phases in relation to the different physical constraints which an electromagnetic radiative mechani…
▽ More
In the transition radiation emission from a N electron bunch hitting at a normal angle of incidence a metallic screen, the transverse and the longitudinal spatial coordinates of the electron bunch play different roles in determining the N single electron radiation field amplitudes and their relative phases in relation to the different physical constraints which an electromagnetic radiative mechanism by a charged beam must meet: i.e., temporal causality and covariance. The distribution of the N electron longitudinal coordinates determines indeed the sequence of the N electron collisions onto the metallic screen and, on the basis of the temporal causality principle, it also determines the distribution function of the relative emission phases of the N single electron field amplitudes from the metallic surface. The distribution of the transverse coordinates of the N electrons contributes as well to determine the relative phase distribution of the N electron field amplitudes at the observation point - located on the longitudinal axis of the reference frame - providing a further phase information that accounts for the transverse displacement of the N electrons with respect to the beam axis. The distribution of the transverse coordinates of the N electrons is a relativistic invariant under a Lorentz transformation with respect to the direction of motion of the beam and, consequently, it is expected to leave a covariant mark on the N single electron amplitudes composing the radiation field. The covariant imprinting of the N electron transverse density on the radiation field affects both the temporal coherent and incoherent parts of the transition radiation energy spectrum. Such a dependence of the N single electron radiation field amplitudes on the electron density in the transverse plane manifests itself as....(abstract partially missed because of lack of space)
△ Less
Submitted 3 July, 2012;
originally announced July 2012.
-
On the Covariance of the Charge Form Factor in the Transition Radiation Energy Spectrum of a Beam at Normal Incidence onto a Metallic Screen
Authors:
Gian Luca Orlandi
Abstract:
A charge-density-like covariance is expected to characterize the transition radiation energy spectrum of a N electron bunch as far as the charge form factor is intended to account for bunch-density effects in the radiation emission. The beam charge passing from a single electron to a high density electron bunch, the covariance of the transition radiation energy is expected to evolve from a charge-…
▽ More
A charge-density-like covariance is expected to characterize the transition radiation energy spectrum of a N electron bunch as far as the charge form factor is intended to account for bunch-density effects in the radiation emission. The beam charge passing from a single electron to a high density electron bunch, the covariance of the transition radiation energy is expected to evolve from a charge-point-like to a charge-density-like one. Besides covariance, the radiation energy spectrum is expected to conform to the temporal causality principle: the N single electron amplitudes composing the radiation field are expected to propagate from the metallic screen with relative emission phases causally correlated with the temporal sequence of the N particle collisions onto the metallic screen. In the present paper, the case of a N electron bunch hitting at a normal angle of incidence a flat metallic surface with arbitrary size and shape will be considered. For such an experimental situation, the distribution function of the N electron longitudinal coordinates rules the temporal causality constraint into the transition radiation energy spectrum. The covariance feature of the transition radiation energy spectrum deals instead with the Lorentz invariance of the projection of the N electron spatial density in the transverse plane with respect to the direction of motion of the N electron beam. Because of the invariance of the N electron transverse density under a Lorentz transformation with respect to the direction of motion of the electron beam, the N single electron radiation amplitudes composing the radiation field show a covariant dependence on the distribution function of the N electron transverse coordinates, the relative emission phases of the N single electron radiation amplitudes...(abstract partially missed because of lack of space)
△ Less
Submitted 3 July, 2012;
originally announced July 2012.
-
Coherence effects in the transition radiation spectrum and practical consequences
Authors:
Gian Luca Orlandi
Abstract:
In the framework of the pseudophotons method and under the hypothesis of the far field approximation the formal evaluation of the transition radiation spectrum produced by a three-dimensional charged beam interacting with a metallic target is carried out. When spatial incoherent conditions are occurring, the transverse size of a three-dimensional beam affects the spectrum via a suitable dependen…
▽ More
In the framework of the pseudophotons method and under the hypothesis of the far field approximation the formal evaluation of the transition radiation spectrum produced by a three-dimensional charged beam interacting with a metallic target is carried out. When spatial incoherent conditions are occurring, the transverse size of a three-dimensional beam affects the spectrum via a suitable dependence on the Fourier transform of the transverse distribution, while the temporal coherent enhance of the spectrum depends only on the longitudinal beam size via the longitudinal form factor in the same manner as in the case of a one-dimensional beam. Spatial incoherent effects, arising at short wave-length in the spectrum, on the one hand allow a better comprehension of some aspects of the transition radiation phenomelogy - e.g. an analytical formula for the total radiated energy - and on the other hand offer new perspectives in the practical application of the transition radiation as diagnostics method of the transverse beam size in a particle accelerator.
△ Less
Submitted 13 June, 2001;
originally announced June 2001.