Real-World Data Analysis of Implantable Cardioverter Defibrillator (ICD) in Patients with Hypertrophic Cardiomyopathy (HCM)
Authors:
Sungrim Moon,
Andrew Wen,
Christopher G. Scott,
Michael J. Ackerman,
Jeffrey B. Geske,
Peter A. Noseworthy,
Steve R Ommen,
Jane L Shellum,
Hongfang Liu,
Rick A. Nishimura
Abstract:
Background: One of the common causes of sudden cardiac death (SCD) in young people is hypertrophic cardiomyopathy (HCM) and the primary prevention of SCD is with an implantable cardioverter defibrillators (ICD). Concerning the incidence of appropriate ICD therapy and the complications associated with ICD implantation and discharge, patients with implanted ICDs are closely monitored and interrogati…
▽ More
Background: One of the common causes of sudden cardiac death (SCD) in young people is hypertrophic cardiomyopathy (HCM) and the primary prevention of SCD is with an implantable cardioverter defibrillators (ICD). Concerning the incidence of appropriate ICD therapy and the complications associated with ICD implantation and discharge, patients with implanted ICDs are closely monitored and interrogation reports are generated from clinical consultations. Methods: In this study, we compared the performance of structured device data and unstructured interrogation reports for extracting information of ICD therapy and heart rhythm. We sampled 687 reports with a gold standard generated through manual chart review. A rule-based natural language processing (NLP) system was developed using 480 reports and the information in the corresponding device data was aggregated for the task. We compared the performance of the NLP system with information aggregated from structured device data using the remaining 207 reports. Results: The rule-based NLP system achieved F-measure of 0.92 and 0.98 for ICD therapy and heart rhythm while the performance of aggregating device data was significantly lower with F-measure of 0.78 and 0.45 respectively. Limitations of using only structured device data include no differentiation of real events from management events, data availability, and disparate perspectives of vendor and data granularity while using interrogation reports needs to overcome non-representative keyword/pattern and contextual errors. Conclusions: Extracting phenotyping information from data generated in real-world requires the incorporation of medical knowledge. It is essential to analyze, compare, and harmonize multiple data sources for real-world evidence generation.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
Role of the electron-phonon coupling in tuning the thermal boundary conductance at metal-dielectric interfaces by inserting ultrathin metal interlayers
Authors:
S. M. Oommen,
S. Pisana
Abstract:
Varying the thermal boundary conductance at metal-dielectric interfaces is of great importance for highly integrated electronic structures such as electronic, thermoelectric and plasmonic devices where heat dissipation is dominated by interfacial effects. In this paper we study the modification of the thermal boundary conductance at metal-dielectric interfaces by inserting metal interlayers of var…
▽ More
Varying the thermal boundary conductance at metal-dielectric interfaces is of great importance for highly integrated electronic structures such as electronic, thermoelectric and plasmonic devices where heat dissipation is dominated by interfacial effects. In this paper we study the modification of the thermal boundary conductance at metal-dielectric interfaces by inserting metal interlayers of varying thickness below 10 nm. We show that the insertion of a tantalum interlayer at the Al/Si and Al/sapphire interfaces strongly hinders the phonon transmission across these boundaries, with a sharp transition and plateau within ~1 nm. We show that the electron-phonon coupling has a major influence on the sharpness of the transition as the interlayer thickness is varied, and if the coupling is strong, the variation in thermal boundary conductance typically saturates within 2 nm. In contrast, the addition of a nickel interlayer at the Al/Si and the Al/sapphire interfaces produces a local minimum as the interlayer thickness increases, due to the similar phonon dispersion in Ni and Al. The weaker electron-phonon coupling in Ni causes the boundary conductance to saturate more slowly. Thermal property measurements were performed using time domain thermo-reflectance and are in good agreement with a formulation of the diffuse mismatch model based on real phonon dispersions that accounts for inelastic phonon scattering and phonon confinement within the interlayer. The analysis of the different assumptions included in the model reveals when inelastic processes should be considered. A hybrid model that introduces inelastic scattering only when the materials are more acoustically matched is found to better predict the thickness dependence of the thermal boundary conductance without any fitting parameters.
△ Less
Submitted 15 November, 2020; v1 submitted 13 October, 2019;
originally announced October 2019.