Detection of proton tracks with LiF Fluorescent Nuclear Track Detectors
Authors:
P. Bilski,
B. Marczewska,
M. Sankowska,
A. Kilian,
J. Swakoń,
Z. Siketić,
P. Olko
Abstract:
Fluorescent nuclear track detectors based on LiF crystals were successfully applied for detection of proton induced tracks. Irradiations were performed with protons with energy ranging from 1 MeV up to about 56 MeV and for all proton energies the fluorescent tracks were observed. The tracks are not continuous, but consist of a series of bright spots. The gaps between spots tend to narrow with decr…
▽ More
Fluorescent nuclear track detectors based on LiF crystals were successfully applied for detection of proton induced tracks. Irradiations were performed with protons with energy ranging from 1 MeV up to about 56 MeV and for all proton energies the fluorescent tracks were observed. The tracks are not continuous, but consist of a series of bright spots. The gaps between spots tend to narrow with decreasing proton energy (increasing ionization density). For the highest of the studied energies, the spots are scattered so sparsely, that it is not possible to link spots belonging to one track. The intensity (brightness) of the fluorescent tracks increases with the increasing LET and agrees well with the trend established earlier for various heavier ions.
△ Less
Submitted 7 March, 2024;
originally announced March 2024.
-
Characterization of a novel proton-CT scanner based on Silicon and LaBr$_3$(Ce) detectors
Authors:
E. Nácher,
J. A. Briz,
A. N. Nerio,
A. Perea,
V. G. Távora,
O. Tengblad,
M. Ciemala,
N. Cieplicka-Orynczak,
A. Maj,
K. Mazurek,
P. Olko,
M. Zieblinski,
M. J. G. Borge
Abstract:
Treatment planning systems at proton-therapy centres generally use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images inst…
▽ More
Treatment planning systems at proton-therapy centres generally use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images instead. The main goal of this work is to test the capabilities of a newly-developed proton-CT scanner, based on the use of a set of tracking detectors and a high energy resolution scintillator for the residual energy of the protons. Different custom-made phantoms were positioned at the field of view of the scanner and were irradiated with protons at the CCB proton-therapy center in Krakow. We measured with the phantoms at different angles and produced sinograms that were used to obtain reconstructed images by Filtered Back-Projection (FBP). The obtained images were used to determine the capabilities of our scanner in terms of spatial resolution and proton Relative Stopping Power mapping and validate its use as proton-CT scanner. The results show that the scanner can produce medium-high quality images, with spatial resolution better than 2 mm in radiography, below 3 mm in tomography and resolving power in the RSP comparable to other state of the art pCT cameras.
△ Less
Submitted 8 May, 2024; v1 submitted 9 July, 2023;
originally announced July 2023.
-
Feasibility of the J-PET to monitor range of therapeutic proton beams
Authors:
Jakub Baran,
Damian Borys,
Karol Brzeziński,
Jan Gajewski,
Michał Silarski,
Neha Chug,
Aurélien Coussat,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Kavya V. Eliyan,
Aleksander Gajos Krzysztof Kacprzak,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Renata Kopeć,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Antony J. Lomax,
Keegan McNamara,
Szymon Niedźwiecki,
Paweł Olko,
Dominik Panek
, et al. (18 additional authors not shown)
Abstract:
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated prot…
▽ More
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.
△ Less
Submitted 28 February, 2023;
originally announced February 2023.
-
The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy
Authors:
M. De Saint-Hubert,
J. Farah,
M. Klodowska,
M. T. Romero-Exposito,
K. Tyminska,
V. Mares,
P. Olko,
L Stolarczyk,
S. Trinkl
Abstract:
This study investigates the influence of several Monte Carlo radiation transport codes and nuclear models on the simulation of secondary neutron spectra and its impact on calculating and measuring neutron doses in proton therapy. Three different multi-purpose Monte Carlo radiation transport codes (FLUKA, MCNPX, Geant4) were used with different available nuclear models to calculate secondary neutro…
▽ More
This study investigates the influence of several Monte Carlo radiation transport codes and nuclear models on the simulation of secondary neutron spectra and its impact on calculating and measuring neutron doses in proton therapy. Three different multi-purpose Monte Carlo radiation transport codes (FLUKA, MCNPX, Geant4) were used with different available nuclear models to calculate secondary neutron energy spectra at various points inside a water tank phantom with PMMA walls using a 10 cm x 10 cm rectangular, mono-energetic proton beam (110, 150, 180, and 210 MeV). Using Kerma approximation secondary neutron doses were calculated applying fluence-to-dose equivalent conversion coefficients in water. Moreover, the impact of varying spectra for electrochemically etched CR39 detector calibration was analyzed for different codes and models. In distal positions beyond the Bragg peak, results show largest variations between the codes, up to 53% for the high energy neutron fluence at 16 cm from the Bragg peak of the 110 MeV proton beam. In lateral positions, the variation between the codes is smaller and for the total neutron fluence within 20%. Variation in the nuclear models in MCNPX was only visible for the proton beam energies of 180 and 210 MeV and modeling the high energy neutron fluence which reached up to 23% for 210 MeV at 11 cm lateral from the beam axis. Impact on neutron dose equivalent was limited for the different models used (<8%) while it was pronounced for the different codes (45% at 16 cm from the Bragg peak of the 110 MeV proton beam). CR39 calibration factors in lateral positions were on average varying 10% between codes and 5 % between nuclear models.This study demonstrated a large impact on the neutron fluence spectra calculated by different codes while the impact of different models in MCNPX proved to be less prominent for the neutron modeling in proton therapy.
△ Less
Submitted 7 December, 2021;
originally announced December 2021.
-
Proton radiographs using position-sensitive silicon detectors and high-resolution scintillators
Authors:
J. A. Briz,
A. N. Nerio,
C. Ballesteros,
M. J. G. Borge,
P. Martínez,
A. Perea,
V. G. Távora,
O. Tengblad,
M. Ciemala,
A. Maj,
P. Olko,
W. Parol,
A. Pedracka,
B. Sowicki,
M. Zieblinski,
E. Nácher
Abstract:
Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and $γ$-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a higher conformity in the treatments. Therefore, it causes less damage to the surrounding healthy tissue and less secondary effects. However, in order to take full ad…
▽ More
Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and $γ$-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a higher conformity in the treatments. Therefore, it causes less damage to the surrounding healthy tissue and less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton Computed Tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Here, results obtained from an experiment performed using a 100-MeV proton beam at the CCB facility in Krakow (Poland) are presented. Proton radiographs of PMMA samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution and sensitivity to different materials. They demonstrate the capabilities of the system to produce images with protons. Structures of up to 2 mm are nicely resolved and the sensitivity of the system was enough to distinguish thicknesses of 10 mm of aluminum or PMMA. This constitutes a first step to validate the device as a proton radiography scanner previous to the future tests as a proton CT scanner.
△ Less
Submitted 16 November, 2021;
originally announced November 2021.
-
Mapping the Future of Particle Radiobiology in Europe: The INSPIRE Project
Authors:
N. T. Henthorn,
O. Sokol,
M. Durante,
L. De Marzi,
F. Pouzoulet,
J. Miszczyk,
P. Olko,
S. Brandenburg,
M-J. van Goethem,
L. Barazzuol,
M. Tambas,
J. A. Langendijk,
M. Davidkova,
V. Vondravcek,
E. Bodenstein,
J. Pawelke,
A. Lomax,
D. C. Weber,
A. Dasu,
B. Stenerlow,
P. R. Poulsen,
B. S. Sorensen,
C. Grau,
M. K. Sitarz,
A-C Heuskin
, et al. (5 additional authors not shown)
Abstract:
Particle therapy is a growing cancer treatment modality worldwide. However, there still remains a number of unanswered questions considering differences in the biological response between particles and photons. These questions, and probing of biological mechanisms in general, necessitate experimental investigation. The Infrastructure in Proton International Research (INSPIRE) project was created t…
▽ More
Particle therapy is a growing cancer treatment modality worldwide. However, there still remains a number of unanswered questions considering differences in the biological response between particles and photons. These questions, and probing of biological mechanisms in general, necessitate experimental investigation. The Infrastructure in Proton International Research (INSPIRE) project was created to provide an infrastructure for European research, unify research efforts on the topic of proton and ion therapy across Europe, and to facilitate the sharing of information and resources. This work highlights the radiobiological capabilities of the INSPIRE partners, providing details of physics (available particle types and energies), biology (sample preparation and post-irradiation analysis), and researcher access (the process of applying for beam time). The collection of information reported here is designed to provide researchers both in Europe and worldwide with the tools required to select the optimal center for their research needs. We also highlight areas of redundancy in capabilities and suggest areas for future investment.
△ Less
Submitted 7 July, 2020;
originally announced July 2020.
-
Analysis of time-profiles with in-beam PET monitoring in charged particle therapy
Authors:
A. C. Kraan,
S. Muraro,
G. Battistoni,
N. Belcari,
M. G. Bisogni,
N. Camarlinghi,
A. Del Guerra,
A. Ferrari,
R. Kopec,
D. Krzempek,
M. Morrocchi,
P. Olko,
P. Sala,
K. Skowronska,
G. Sportelli,
A. Topi,
V. Rosso
Abstract:
Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability…
▽ More
Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability of MC predictions of space and time (decay rate) profiles shortly after irradiation, and we show how the decay rates can give an indication about the elements of which the phantom is made up.
Methods and Materials: Various phantoms were irradiated in clinical and near-clinical conditions at the Cyclotron Centre of the Bronowice proton therapy centre. PET data were acquired with a planar 16x16 cm$^2$ PET system. MC simulations of particle interactions and photon propagation in the phantoms were performed using the FLUKA code. The analysis included a comparison between experimental data and MC simulations of space and time profiles, as well as a fitting procedure to obtain the various isotope contributions in the phantoms.
Results and conclusions: There was a good agreement between data and MC predictions in 1-dimensional space and decay rate distributions. The fractions of $^{11}$C, $^{15}$O and $^{10}$C that were obtained by fitting the decay rates with multiple simple exponentials generally agreed well with the MC expectations. We found a small excess of $^{10}$C in data compared to what was predicted in MC, which was clear especially in the PE phantom.
△ Less
Submitted 28 September, 2018;
originally announced September 2018.
-
Radial distribution of dose within heavy charged particle tracks. Models and experimental verification using LiF:Mg,Cu,P TL detectors
Authors:
W. Gieszczyk,
P. Bilski,
P. Olko,
B. Obryk
Abstract:
A new method of experimental verification of radial dose distribution models using solid state thermoluminescent (TL) detectors LiF:Mg,Cu,P has been recently proposed. In this work the method was applied to verify the spatial distribution of energy deposition within a single 131Xe ion track. Detectors were irradiated at the Department of Physics of the University of Jyväskylä, Finland. The obtaine…
▽ More
A new method of experimental verification of radial dose distribution models using solid state thermoluminescent (TL) detectors LiF:Mg,Cu,P has been recently proposed. In this work the method was applied to verify the spatial distribution of energy deposition within a single 131Xe ion track. Detectors were irradiated at the Department of Physics of the University of Jyväskylä, Finland. The obtained results have been compared with theoretical data, calculated according to the Zhang et al., Cucinotta et al. and Geiss et al. radial dose distribution (RDD) models. At the lowest dose range the Zhang et al. RDD model exhibited the best agreement as compared to experimental data. In the intermediate dose range, up to 104 Gy, the best agreement was found for the RDD model of Cucinotta et al. The probability of occurrence of doses higher than 104 Gy within a single 131Xe ion track was found to be lower than predicted by all the studied RDD models. This may be a result of diffusion of the charge, which is then captured by TL-related trapping sites, at the distances up to dozens of nanometers from the ionization site.
△ Less
Submitted 26 January, 2014;
originally announced January 2014.