-
Enhanced beam transport via space charge mitigation in a multistage accelerator for fusion plasma diagnostics
Authors:
M. Nishiura,
K. Nakamura,
K. Ueda,
A. Shimizu,
H. Takubo,
M. Kanda,
T. Ido,
M. Okamura
Abstract:
Efficient transport of high-current negative ion beams is critical for accurate plasma potential diagnostics using heavy-ion beam probe (HIBP) systems in magnetically confined fusion plasmas. However, strong space-charge effects often degrade transport efficiency, particularly for heavy ions such as Au-. In this study, we demonstrate a substantial improvement in beam transport by introducing an el…
▽ More
Efficient transport of high-current negative ion beams is critical for accurate plasma potential diagnostics using heavy-ion beam probe (HIBP) systems in magnetically confined fusion plasmas. However, strong space-charge effects often degrade transport efficiency, particularly for heavy ions such as Au-. In this study, we demonstrate a substantial improvement in beam transport by introducing an electrostatic lens effect through optimized voltage allocation in a multistage acceleration system. Numerical simulations using IGUN, supported by experiments with the LHD-HIBP system, show that this approach effectively suppresses space-charge-induced beam divergence and loss. Without requiring mechanical modifications to the beamline, the optimized configuration enables a 2-3 fold increase in Au-beam current injected into the tandem accelerator. Consequently, plasma potential measurements were extended to higher-density plasmas, reaching line-averaged electron densities up to $1.75\times 10^{19}$ m$^{-3}$ with improved signal-to-noise ratio. This technique offers a compact, practical, and highly effective solution for transporting high-current heavy-ion beams under space-charge-dominated conditions. Beyond its impact on plasma diagnostics, the method is broadly applicable to a wide range of accelerator systems, including those used in scientific and industrial applications where high-intensity beam transport is required.
△ Less
Submitted 20 September, 2025; v1 submitted 28 July, 2025;
originally announced July 2025.
-
Optically Pumped Polarized $^3$He$^{++}$ Ion Source Development for RHIC/EIC
Authors:
A. Zelenski,
G. Atoian,
E. Beebe,
S. Ikeda,
T. Kanesue,
S. Kondrashev,
J. Maxwell,
R. Milner,
M. Musgrave,
M. Okamura,
A. A. Poblaguev,
D. Raparia,
J. Ritter,
A. Sukhanov,
S. Trabocchi
Abstract:
The proposed polarized $^3$He$^{++}$ acceleration in RHIC and the future Electron-Ion Collider will require about $2\times10^{11}$ ions in the source pulse. A new technique had been proposed for production of high intensity polarized $^3$He$^{++}$ ion beams. It is based on ionization and accumulation of the $^3$He gas (polarized by metastability-exchange optical pumping and in the 5 T high magneti…
▽ More
The proposed polarized $^3$He$^{++}$ acceleration in RHIC and the future Electron-Ion Collider will require about $2\times10^{11}$ ions in the source pulse. A new technique had been proposed for production of high intensity polarized $^3$He$^{++}$ ion beams. It is based on ionization and accumulation of the $^3$He gas (polarized by metastability-exchange optical pumping and in the 5 T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel $^3$He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized $^3$He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3--5 T field has been developed. The $^3$He polarization 80--85\% (and sufficiently long $\sim30$ min relaxation time) was obtained in the \lq\lq{open}\rq\rq\ cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and $^3$He $^4$He absolute nuclear polarimeter at 6 MeV $^3$He$^{++}$ beam energy is also presented.
△ Less
Submitted 7 July, 2023; v1 submitted 18 March, 2023;
originally announced March 2023.
-
Ion Sources for Production of Highly Charged Ion Beams
Authors:
Alain Lapierre,
Janilee Benitez,
Masahiro Okamura,
Damon Todd,
Daniel Xie,
Yine Sun
Abstract:
Intense Highly Charged Ion Beams (HCIB) from injector and charge-breeder ion sources at heavy ion accelerator facilities are in demand to expand research in particle and nuclear physics as well as for radiation effects testing. With current accelerator upgrades and advances in accelerator technologies, not all HCIB demands can be met with existing ion sources. Continued Research and Development (R…
▽ More
Intense Highly Charged Ion Beams (HCIB) from injector and charge-breeder ion sources at heavy ion accelerator facilities are in demand to expand research in particle and nuclear physics as well as for radiation effects testing. With current accelerator upgrades and advances in accelerator technologies, not all HCIB demands can be met with existing ion sources. Continued Research and Development (R&D) in this field are therefore essential to continually improve their performance and match the unprecedented and increasingly higher HCIB requirements from the accelerator community. This White Paper discusses the present production capabilities of ion sources of HCIB, and the potentials of future Highly Charged Ion (HCI) sources. It discusses the strengths and weaknesses of such sources along with paths forward for improving their performance to meet the requirements of present and future heavy ion accelerator facilities. This document is meant to be utilized as a basis to guide the conceptual design of future accelerators.
△ Less
Submitted 25 May, 2022;
originally announced May 2022.
-
Toward inertial confinement fusion energy based on heavy ion beam
Authors:
S. Kawata,
M. Okamura,
K. Horioka,
C. Deutsch,
T. Karino,
D. H. H. Hoffmann,
Y. Zhao,
S. Ikeda,
T. Kanesue,
A. I. Ogoyski
Abstract:
Heavy ion inertial fusion (HIF) energy would be one of promising energy resources securing our future energy in order to sustain our human life for centuries and beyond. The heavy ion beam (HIB) has remarkable preferable features to release the fusion energy in inertial confinement fusion: in particle accelerators HIBs are generated with a high driver efficiency of ~ 30-40%, and the HIB ions depos…
▽ More
Heavy ion inertial fusion (HIF) energy would be one of promising energy resources securing our future energy in order to sustain our human life for centuries and beyond. The heavy ion beam (HIB) has remarkable preferable features to release the fusion energy in inertial confinement fusion: in particle accelerators HIBs are generated with a high driver efficiency of ~ 30-40%, and the HIB ions deposit their energy inside of materials. Therefore, a requirement for the fusion target energy gain is relatively low, that would be ~50-70 to operate a HIF fusion reactor with the standard energy output of 1GW of electricity. The HIF reactor operation frequency would be ~10~15 Hz or so. Several-MJ HIBs illuminate a fusion fuel target, and the fuel target is imploded to about a thousand times of the solid density. Then the DT fuel is ignited and burned. The HIB ion deposition range would be ~0.5-1 mm or so depending on the material. Therefore, a relatively large density-scale length appears in the fuel target material. The large density-gradient-scale length helps to reduce the Rayleigh-Taylor (R-T) growth rate. The key merits in HIF physics are presented in the article toward our bright future energy resource.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Effects of Different Hand-Grounding Locations on Haptic Performance With a Wearable Kinesthetic Haptic Device
Authors:
Sajid Nisar,
Melisa Orta Martinez,
Takahiro Endo,
Fumitoshi Matsuno,
Allison M. Okamura
Abstract:
Grounding of kinesthetic feedback against a user's hand can increase the portability and wearability of a haptic device. However, the effects of different hand-grounding locations on haptic perception of a user are unknown. In this letter, we investigate the effects of three different hand-grounding locations-back of the hand, proximal phalanx of the index finger, and middle phalanx of the index f…
▽ More
Grounding of kinesthetic feedback against a user's hand can increase the portability and wearability of a haptic device. However, the effects of different hand-grounding locations on haptic perception of a user are unknown. In this letter, we investigate the effects of three different hand-grounding locations-back of the hand, proximal phalanx of the index finger, and middle phalanx of the index finger-on haptic perception using a newly designed wearable haptic device. The novel device can provide kinesthetic feedback to the user's index finger in two directions: along the finger-axis and in the finger's flexion-extension movement direction. We measure users' haptic perception for each grounding location through a psychophysical experiment for each of the two feedback directions. Results show that among the studied locations, grounding at proximal phalanx has a smaller average just noticeable difference for both feedback directions, indicating a more sensitive haptic perception. The realism of the haptic feedback, based on user ratings, was the highest with grounding at the middle phalanx for feedback along the finger axis, and at the proximal phalanx for feedback in the flexion-extension direction. Users identified the haptic feedback as most comfortable with grounding at the back of the hand for feedback along the finger axis and at the proximal phalanx for feedback in the flexion-extension direction. These findings show that the choice of grounding location has a significant impact on the user's haptic perception and qualitative experience. The results provide insights for designing next-generation wearable hand-grounded kinesthetic devices to achieve better haptic performance and user experience in virtual reality and teleoperated robotic applications.
△ Less
Submitted 2 June, 2019;
originally announced June 2019.