-
High efficiency veto hadron calorimeter in the NA64 experiment at CERN
Authors:
Yu. M. Andreev,
A. Antonov,
M. A. Ayala Torres,
D. Banerjee,
B. Banto Oberhauser,
V. Bautin,
J. Bernhard,
P. Bisio,
M. Bondì,
A. Celentano,
N. Charitonidis,
P. Crivelli,
A. V. Dermenev,
S. V. Donskov,
R. R. Dusaev,
T. Enik,
V. N. Frolov,
S. V. Gertsenberger,
S. Girod,
S. N. Gninenko,
M. Hösgen,
Y. Kambar,
A. E. Karneyeu,
G. Kekelidze,
B. Ketzer
, et al. (31 additional authors not shown)
Abstract:
NA64 is a fixed-target experiment at the CERN SPS designed to search for Light particle Dark Matter (LDM) candidates with masses in the sub-GeV range. During the 2016-2022 runs, the experiment obtained the world-leading constraints, leaving however part of the well-motivated region of parameter space suggested by benchmark LDM models still unexplored. To further improve sensitivity, as part of the…
▽ More
NA64 is a fixed-target experiment at the CERN SPS designed to search for Light particle Dark Matter (LDM) candidates with masses in the sub-GeV range. During the 2016-2022 runs, the experiment obtained the world-leading constraints, leaving however part of the well-motivated region of parameter space suggested by benchmark LDM models still unexplored. To further improve sensitivity, as part of the upgrades to the setup of NA64 at the CERN SPS H4 beamline, a prototype veto hadron calorimeter (VHCAL) was installed in the downstream region of the experiment during the 2023 run. The VHCAL, made of Cu-Sc layers, was expected to be an efficient veto against upstream electroproduction of large-angle hadrons or photon-nuclear interactions, reducing the background from secondary particles escaping the detector acceptance. With the collected statistics of $4.4\times10^{11}$ electrons on target (EOT), we demonstrate the effectiveness of this approach by rejecting this background by more than an order of magnitude. This result provides an essential input for designing a full-scale optimized VHCAL to continue running background-free during LHC Run 4, when we expect to collect $10^{13}$ EOT. Furthermore, this technique combined with improvements in the analysis enables us to decrease our missing energy threshold from 50 GeV to 40 GeV thereby enhancing the signal sensitivity of NA64.
△ Less
Submitted 28 March, 2025; v1 submitted 14 March, 2025;
originally announced March 2025.
-
Proof of principle for a light dark matter search with low-energy positron beams at NA64
Authors:
Yu. M. Andreev,
A. Antonov,
M. A. Ayala Torres,
D. Banerjee,
B. Banto Oberhauser,
V. Bautin,
J. Bernhard,
P. Bisio,
M. Bondì,
A. Celentano,
N. Charitonidis,
P. Crivelli,
A. V. Dermenev,
S. V. Donskov,
R. R. Dusaev,
T. Enik,
V. N. Frolov,
S. V. Gertsenberger,
S. Girod,
S. N. Gninenko,
M. Hösgen,
Y. Kambar,
A. E. Karneyeu,
G. Kekelidze,
B. Ketzer
, et al. (32 additional authors not shown)
Abstract:
Thermal light dark matter (LDM) with particle masses in the 1 MeV - 1 GeV range could successfully explain the observed dark matter abundance as a relic from the primordial Universe. In this picture, a new feeble interaction acts as a "portal" between the Standard Model and LDM particles, allowing for the exploration of this paradigm at accelerator experiments. In the last years, the "missing ener…
▽ More
Thermal light dark matter (LDM) with particle masses in the 1 MeV - 1 GeV range could successfully explain the observed dark matter abundance as a relic from the primordial Universe. In this picture, a new feeble interaction acts as a "portal" between the Standard Model and LDM particles, allowing for the exploration of this paradigm at accelerator experiments. In the last years, the "missing energy" experiment NA64e at CERN SPS (Super Proton Synchrotron) has set world-leading constraints in the vector-mediated LDM parameter space, by exploiting a 100 GeV electron beam impinging on an electromagnetic calorimeter, acting as an active target. In this paper, we report a detailed description of the analysis of a preliminary measurement with a 70 GeV positron beam at NA64e, performed during summer 2023 with an accumulated statistic of 1.6 x 10^10 positrons on target. This data set was analyzed with the primary aim of evaluating the performance of the NA64e detector with a lower energy positron beam, towards the realization of the post-LS3 program. The analysis results, other than additionally probing unexplored regions in the LDM parameter space, provide valuable information towards the future NA64e positron campaign.
△ Less
Submitted 28 May, 2025; v1 submitted 6 February, 2025;
originally announced February 2025.
-
Application of the VMM3a/SRS: A t0-less TWIN GEM-based TPC
Authors:
K. J. Flöthner,
F. Garcia,
B. Oberhauser,
F. Brunbauer,
M. W. Heiss,
D. Janssens,
B. Ketzer,
M. Lisowska,
M. Meurer,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewsk,
J. Samarati,
F. Sauli,
L. Scharenberg,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
Integrating the ATLAS/BNL VMM3a ASIC (Application Specific Integrated Circuit) into the RD51/SRS (Scalable Readout System) provides a self-triggered continuous readout system for various gaseous detectors. Since the system allows flexible parameters, such as switching the polarity, adjusting electronics gain or different peaking times, the settings can be adjusted for a wide range of detectors. Th…
▽ More
Integrating the ATLAS/BNL VMM3a ASIC (Application Specific Integrated Circuit) into the RD51/SRS (Scalable Readout System) provides a self-triggered continuous readout system for various gaseous detectors. Since the system allows flexible parameters, such as switching the polarity, adjusting electronics gain or different peaking times, the settings can be adjusted for a wide range of detectors. The system allows particles to be recorded with a MHz interaction rate in energy, space, and time.
The system will be introduced in the beginning, and short examples will be given for different applications. After, the Twin GEM TPC will be discussed in more detail to show the benefits of such a trigger-less system in combination with the Twin configuration. Last, a few results for the tracking performance and the possibility to operate as a tracking telescope will be shown. Thus, this presents the possibility of an extremely low material budget tracking system suitable for tracking from high to low-energy particle beams.
△ Less
Submitted 17 January, 2025;
originally announced January 2025.
-
The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout
Authors:
F. Garcia,
K. J. Flöthner,
A. Amato,
S. Biswas,
F. M. Brunbauer,
M. W. Heiss,
G. Janka,
D. Janssens,
M. Lisowska,
M. Meurer,
H. Muller,
B. Banto Oberhauser,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
T. Prokscha,
L. Ropelewski,
L. Scharenberg,
J. Samarati,
F. Sauli,
M. van Stenis,
R. Veenhof,
B. Zeh,
X. Zhao
Abstract:
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas tra…
▽ More
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.
△ Less
Submitted 18 March, 2025; v1 submitted 16 January, 2025;
originally announced January 2025.
-
Measurement of the intrinsic hadronic contamination in the NA64$-e$ high-purity $e^+/e^-$ beam at CERN
Authors:
Yu. M. Andreev,
D. Banerjee,
B. Banto Oberhauser,
J. Bernhard,
P. Bisio,
M. Bondi,
A. Celentano,
N. Charitonidis,
A. G. Chumakov,
D. Cooke,
P. Crivelli,
E. Depero,
A. V. Dermenev,
S. V. Donskov,
R. R. Dusaev,
T. Enik,
V. N. Frolov,
A. Gardikiotis,
S. G. Gerassimov,
S. N. Gninenko,
M. H"osgen,
M. Jeckel,
V. A. Kachanov,
Y. Kambar,
A. E. Karneyeu
, et al. (43 additional authors not shown)
Abstract:
In this study, we present the measurement of the intrinsic hadronic contamination at the CERN SPS H4 beamline configured to transport electrons and positrons at 100 GeV/c momentum. The analysis was performed using data collected by the NA64-$e$ experiment in 2022. Our study is based on calorimetric measurements, exploiting the different interaction mechanisms of electrons and hadrons in the NA64-E…
▽ More
In this study, we present the measurement of the intrinsic hadronic contamination at the CERN SPS H4 beamline configured to transport electrons and positrons at 100 GeV/c momentum. The analysis was performed using data collected by the NA64-$e$ experiment in 2022. Our study is based on calorimetric measurements, exploiting the different interaction mechanisms of electrons and hadrons in the NA64-ECAL and NA64-HCAL detectors. We determined the intrinsic hadronic contamination by comparing the results obtained using the nominal electron/positron beamline configuration with those obtained in a dedicated setup, in which only hadrons impinged on the detector. The significant differences in the experimental signatures of electrons and hadrons motivated our approach, resulting in a small and well-controlled systematic uncertainty for the measurement. Our study allowed us to precisely determine the intrinsic hadronic contamination, which represents a crucial parameter for the NA64 experiment in which the hadron contaminants may result in non-trivial backgrounds. Moreover, we performed dedicated Monte Carlo simulations for the hadron production induced by the primary T2 target. We found a good agreement between measurements and simulation results, confirming the validity of the applied methodology and our evaluation of the intrinsic hadronic contamination.
△ Less
Submitted 11 October, 2023; v1 submitted 30 May, 2023;
originally announced May 2023.