Possible depth-resolved reconstruction of shear moduli in the cornea following collagen crosslinking (CXL) with optical coherence tomography and elastography
Authors:
Gabriel Regnault,
Mitchell A. Kirby,
Ruikang K. Wang,
Tueng T. Shen,
Matthew O'Donnell,
Ivan Pelivanov
Abstract:
Corneal collagen crosslinking (CXL) is commonly used to prevent or treat keratoconus. Although changes in corneal stiffness induced by CXL surgery can be monitored with non-contact dynamic optical coherence elastography (OCE) by tracking mechanical wave propagation, depth dependent changes are still unclear if the cornea is not crosslinked through the whole depth. Here, phase-decorrelation measure…
▽ More
Corneal collagen crosslinking (CXL) is commonly used to prevent or treat keratoconus. Although changes in corneal stiffness induced by CXL surgery can be monitored with non-contact dynamic optical coherence elastography (OCE) by tracking mechanical wave propagation, depth dependent changes are still unclear if the cornea is not crosslinked through the whole depth. Here, phase-decorrelation measurements on optical coherence tomography (OCT) structural images are combined with acoustic micro-tapping (A$μ$T) OCE to explore possible reconstruction of depth-dependent stiffness within crosslinked corneas in an ex vivo human cornea sample. Experimental OCT images are analyzed to define the penetration depth of CXL into the cornea. In a representative ex vivo human cornea sample, crosslinking depth varied from $\sim 100μm$ in the periphery to $\sim 150μm$ in the cornea center and exhibited a sharp in-depth transition between crosslinked and untreated areas. This information was used in an analytical two-layer guided wave propagation model to quantify the stiffness of the treated layer. We also discuss how the elastic moduli of partially CXL-treated cornea layers reflect the effective engineering stiffness of the entire cornea to properly quantify corneal deformation.
△ Less
Submitted 26 June, 2023;
originally announced June 2023.
-
Possible depth-resolved reconstruction of shear moduli in the cornea following collagen crosslinking (CXL) with optical coherence tomography and elastography
Authors:
Gabriel Regnault,
Mitchell A. Kirby,
Ruikang K. Wang,
Tueng T. Shen,
Matthew O'Donnell,
Ivan Pelivanov
Abstract:
Collagen crosslinking of the cornea (CXL) is commonly employed to prevent or treat keratoconus. Although the change of corneal stiffness induced by CXL surgery can be monitored with non-contact dynamic Optical Coherence Elastography (OCE) by tracking mechanical wave propagation, the depth dependence of this change is still unclear if the cornea is not crosslinked through the whole depth. Here we p…
▽ More
Collagen crosslinking of the cornea (CXL) is commonly employed to prevent or treat keratoconus. Although the change of corneal stiffness induced by CXL surgery can be monitored with non-contact dynamic Optical Coherence Elastography (OCE) by tracking mechanical wave propagation, the depth dependence of this change is still unclear if the cornea is not crosslinked through the whole depth. Here we propose to combine phase-decorrelation measurement applied to OCT structural images and acoustic micro-tapping (A$μ$T) OCE to explore possible depth reconstruction of stiffness within crosslinked corneas in an ex vivo human cornea sample. The analysis of experimental OCT images is used to define the penetration depth of CXL into the cornea, which varies from $\sim$100$μm$ in the periphery to $\sim$150$μm$ in the central area and exhibits a sharp transition between areas. This information was used in a two-layer analytical model to quantify the stiffness of the treated layer. We also discuss how the elastic moduli of partially CXL-treated cornea layers reconstructed from OCE measurements reflect the effective mechanical stiffness of the entire cornea to properly quantify surgical outcome.
△ Less
Submitted 25 April, 2023; v1 submitted 27 January, 2023;
originally announced January 2023.
-
Non-contact acoustic micro-tapping optical coherence elastography for quantification of corneal anisotropic elasticity: in vivo rabbit study
Authors:
Mitchell A Kirby,
Gabriel Regnault,
Ivan Pelivanov,
Matthew O'Donnell,
Ruikang Wang,
Tueng T. Shen
Abstract:
Purpose. To demonstrate accurate measurement of corneal elastic moduli in vivo with non-contact and non-invasive optical coherence elastography. Methods. Elastic properties (in-plane Young's modulus E and both in-plane, u, and out-of-plane, G, shear moduli) of rabbit cornea were quantified in vivo using non-contact dynamic Acoustic micro-Tapping Optical Coherence Elastography (AuT-OCE). The IOP-de…
▽ More
Purpose. To demonstrate accurate measurement of corneal elastic moduli in vivo with non-contact and non-invasive optical coherence elastography. Methods. Elastic properties (in-plane Young's modulus E and both in-plane, u, and out-of-plane, G, shear moduli) of rabbit cornea were quantified in vivo using non-contact dynamic Acoustic micro-Tapping Optical Coherence Elastography (AuT-OCE). The IOP-dependence of measured mechanical properties was explored in extracted whole globes following in vivo measurement. A nearly-incompressible transverse isotropic (NITI) model was used to reconstruct moduli from AuT-OCE data. Independently, cornea elastic moduli were also measured ex vivo with traditional, destructive mechanical tests (tensile extensometry and shear rheometry). Results. Our study demonstrates strong anisotropy of corneal elasticity in rabbits. The in-plane Young's modulus, computer as E=3u, was in the range of 20-44 MPa, whereas the out-of-plane shear modulus was in the range of 34-261 kPa. Both pressure-dependent ex vivo OCE and destructive mechanical tests performed on the same samples within an hour of euthanasia strongly support the results of AuT-OCE measurements. Conclusions. Non-contact AuT-OCE can non-invasively quantify cornea anisotropic elastic properties in vivo. Translational Relevance. As OCT is broadly accepted in Ophthalmology, these results suggest the potential for rapid translation of AuT-OCE into clinical practice. In addition, AuT-OCE can likely improve diagnostic criteria of ectatic corneal diseases, leading to early diagnosis, reduced complications, customized surgical treatment, and personalized biomechanical models of the eye.
△ Less
Submitted 25 January, 2023;
originally announced January 2023.
-
Rastreo muscular móvil usando magnetomicrometría -- traducción al español del articulo "Untethered Muscle Tracking Using Magnetomicrometry" por el autor Cameron R. Taylor
Authors:
Cameron R. Taylor,
Seong Ho Yeon,
William H. Clark,
Ellen G. Clarrissimeaux,
Mary Kate O'Donnell,
Thomas J. Roberts,
Hugh M. Herr
Abstract:
Muscle tissue drives nearly all movement in the animal kingdom, providing power, mobility, and dexterity. Technologies for measuring muscle tissue motion, such as sonomicrometry, fluoromicrometry, and ultrasound, have significantly advanced our understanding of biomechanics. Yet, the field lacks the ability to monitor muscle tissue motion for animal behavior outside the lab. Towards addressing thi…
▽ More
Muscle tissue drives nearly all movement in the animal kingdom, providing power, mobility, and dexterity. Technologies for measuring muscle tissue motion, such as sonomicrometry, fluoromicrometry, and ultrasound, have significantly advanced our understanding of biomechanics. Yet, the field lacks the ability to monitor muscle tissue motion for animal behavior outside the lab. Towards addressing this issue, we previously introduced magnetomicrometry, a method that uses magnetic beads to wirelessly monitor muscle tissue length changes, and we validated magnetomicrometry via tightly-controlled in situ testing. In this study we validate the accuracy of magnetomicrometry against fluoromicrometry during untethered running in an in vivo turkey model. We demonstrate real-time muscle tissue length tracking of the freely-moving turkeys executing various motor activities, including ramp ascent and descent, vertical ascent and descent, and free roaming movement. Given the demonstrated capacity of magnetomicrometry to track muscle movement in untethered animals, we feel that this technique will enable new scientific explorations and an improved understanding of muscle function. -- --
El tejido muscular es el motor de casi todos los movimientos del reino animal, ya que proporciona fuerza, movilidad y destreza. Las tecnologías para medir el movimiento del tejido muscular, como la sonomicrometría, la fluoromicrometría y el ultrasonido, han avanzado considerablemente la comprensión de la biomecánica. Sin embargo, este campo carece de la capacidad de rastrear el movimiento del tejido muscular en el comportamiento animal fuera del laboratorio. Para abordar este problema, presentamos previamente la magnetomicrometría, un método que utiliza pequeños imanes para rastrear de forma inalámbrica los cambios de longitud del tejido muscular, y validamos la magnetomicrometría mediante pruebas estrechamente controladas in situ. En este estudio validamos la precisión de la magnetomicrometría en comparación con la fluoromicrometría usando un modelo de pavo in vivo mientras corre libremente. Demostramos el rastreo en tiempo real de la longitud del tejido muscular de los pavos que se mueven libremente ejecutando varias actividades motoras, incluyendo el ascenso y el descenso en rampa, el ascenso y el descenso vertical, y el movimiento libre. Dada la capacidad demostrada de la magnetomicrometría para rastrear el movimiento muscular en animales en un contexto móvil, creemos que esta técnica permitirá nuevas exploraciones científicas y una mejor comprensión de la función muscular.
△ Less
Submitted 19 November, 2022;
originally announced November 2022.
-
Non-contact acoustic micro-tapping optical coherence elastography for evaluating biomechanical changes in the cornea following UV/riboflavin collagen cross linking: ex vivo human study
Authors:
Mitchell A. Kirby,
Ivan Pelivanov,
Gabriel Regnault,
John J. Pitre,
Ryan T. Wallace,
Matthew O'Donnell,
Ruikang Wang,
Tueng T. Shen
Abstract:
Purpose: To evaluate changes in the anisotropic elastic properties of ex vivo human cornea treated with UV cross-linking (CXL) using non-contact acoustic micro-tapping Optical Coherence Elastography (AuT-OCE) Design: AuT performed on normal and CXL ex vivo human donor cornea Methods: Elastic properties of normal and UV CXL treated human corneas were quantified using non-contact acoustic micro-tapp…
▽ More
Purpose: To evaluate changes in the anisotropic elastic properties of ex vivo human cornea treated with UV cross-linking (CXL) using non-contact acoustic micro-tapping Optical Coherence Elastography (AuT-OCE) Design: AuT performed on normal and CXL ex vivo human donor cornea Methods: Elastic properties of normal and UV CXL treated human corneas were quantified using non-contact acoustic micro-tapping Optical Coherence Elastography (AuT-OCE) Main Outcome Measures: Corneal elastic moduli (in-plane Young's, E, and out-of-plane shear, G) can be evaluated in both normal and CXL treated tissues, as well as during the CXL procedure using non-contact AuT-OCE. Results: CXL induced a significant increase in both the tensile and shear moduli in human cornea. The mean in the paired study (pre- and post-, n=7) of the in-plane Young's modulus, E=3u, increased from 19 MPa to 43 MPa while the out-of-plane shear modulus, G, increased from 188 kPa to 673 kPa. Mechanical tests in a subgroup support CXL-induced cornea moduli changes and generally agree with AuT-OCE. Conclusions: The human cornea is a highly anisotropic material where in-plane mechanical properties are very different from those out-of-plane. Non-contact AuT-OCE can measure changes in the anisotropic elastic properties in human cornea as a result of UV-CXL.
△ Less
Submitted 15 September, 2022; v1 submitted 28 June, 2022;
originally announced June 2022.
-
Spatial resolution in optical coherence elastography of bounded media
Authors:
Gabriel Regnault,
Mitchell A. Kirby,
Maju Kuriakose,
Tueng T. Shen,
Ruikang K. Wang,
Matthew O'Donnell,
Ivan Pelivanov
Abstract:
Dynamic optical coherence elastography (OCE) tracks mechanical wave propagation in the subsurface region of tissue to image its shear modulus. For bulk shear waves, the lateral resolution of the reconstructed modulus map (i.e., elastographic resolution) can approach optical coherence tomography (OCT) capabilities, typically a few tens of microns. Here we perform comprehensive numerical simulations…
▽ More
Dynamic optical coherence elastography (OCE) tracks mechanical wave propagation in the subsurface region of tissue to image its shear modulus. For bulk shear waves, the lateral resolution of the reconstructed modulus map (i.e., elastographic resolution) can approach optical coherence tomography (OCT) capabilities, typically a few tens of microns. Here we perform comprehensive numerical simulations and acoustic micro-tapping OCE experiments to show that for the typical situation of guided wave propagation in bounded media, such as cornea, the elastographic resolution cannot reach the OCT resolution and is mainly defined by the thickness of the bounded tissue layer. We considered the excitation of both broadband and quasi-harmonic guided waves in a bounded, isotropic medium. Leveraging the properties of broadband pulses, a robust method for modulus reconstruction with minimum artifacts at interfaces is demonstrated. In contrast, tissue bounding creates large instabilities in the phase of harmonic waves, leading to serious artifacts in modulus reconstructions.
△ Less
Submitted 27 June, 2022;
originally announced June 2022.
-
Delineating corneal elastic anisotropy in a porcine model using non-contact optical coherence elastography and ex vivo mechanical tests
Authors:
Mitchell A. Kirby,
John J. Pitre,
Hong-Cin Liou,
David S. Li,
Ruikang Wang,
Ivan Pelivanov,
Matthew O'Donnell,
Tueng T. Shen
Abstract:
Objective: To compare non-contact acoustic micro-tapping optical coherence elastography (AuT-OCE) with destructive mechanical tests to confirm corneal elastic anisotropy.
Design: Ex vivo, laboratory study with non-contact AuT-OCE followed by mechanical rheometry and extensometry.
Subjects: Inflated cornea of whole-globe porcine eyes.
Methods: A non-contact transducer was used to launch mecha…
▽ More
Objective: To compare non-contact acoustic micro-tapping optical coherence elastography (AuT-OCE) with destructive mechanical tests to confirm corneal elastic anisotropy.
Design: Ex vivo, laboratory study with non-contact AuT-OCE followed by mechanical rheometry and extensometry.
Subjects: Inflated cornea of whole-globe porcine eyes.
Methods: A non-contact transducer was used to launch mechanical waves in the cornea that were imaged with phase-sensitive OCT at physiologically relevant pressures. Reconstruction of both Young's modulus (E) and out-of-plane shear modulus (G) in the cornea from experimental data was performed using a model of a nearly incompressible transversally isotropic (NITI) medium. Samples were then excised and parallel plate rheometry was performed to measure the shear modulus G. Corneal samples were then subjected to strip extensomety to measure the Young's modulus.
Main Outcome Measures: Strong corneal anisotropy was confirmed with both AuT-OCE and mechanical tests, with the Young's and shear moduli differing by over an order of magnitude. These results show that AuT-OCE can quantify both moduli with a non-contact, non-invasive, clinically translatable technique.
△ Less
Submitted 27 May, 2021;
originally announced May 2021.
-
Nearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE
Authors:
John J Pitre Jr,
Mitchell A Kirby,
David S Li,
Tueng T Shen,
Ruikang K Wang,
Matthew O'Donnell,
Ivan Pelivanov
Abstract:
The cornea provides the largest refractive power for the human visual system. Its stiffness, along with intraocular pressure (IOP), are linked to several pathologies, including keratoconus and glaucoma. Although mechanical tests can quantify corneal elasticity ex vivo, they cannot be used clinically. Optical coherence elastography (OCE), which launches and tracks shear waves to estimate stiffness,…
▽ More
The cornea provides the largest refractive power for the human visual system. Its stiffness, along with intraocular pressure (IOP), are linked to several pathologies, including keratoconus and glaucoma. Although mechanical tests can quantify corneal elasticity ex vivo, they cannot be used clinically. Optical coherence elastography (OCE), which launches and tracks shear waves to estimate stiffness, provides an attractive non-contact probe of corneal elasticity. To date, however, OCE studies report corneal moduli around tens of kPa, orders-of-magnitude less than those (few MPa) obtained by tensile/inflation testing. This large discrepancy impedes OCE's clinical adoption. Based on corneal microstructure, we introduce and fully characterize a nearly-incompressible transversally isotropic (NITI) model depicting corneal biomechanics. We show that the cornea must be described by two shear moduli, contrary to current single-modulus models, decoupling tensile and shear responses. We measure both as a function of IOP in ex vivo porcine cornea, obtaining values consistent with both tensile and shear tests. At pressures above 30 mmHg, the model begins to fail, consistent with non-linear changes in cornea at high IOP.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
Fluence compensation for real-time spectroscopic photoacoustic imaging
Authors:
MinWoo Kim,
Geng-Shi Jeng,
Matthew O'Donnell,
Ivan Pelivanov
Abstract:
Recently we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam sweeping at high repetition rate over the desired imaging area, in contrast to the conventional PA approach using broad beam illumination at a low repetition. One significant advantage o…
▽ More
Recently we demonstrated an integrated photoacoustic (PA) and ultrasound (PAUS) system using a kHz-rate wavelength-tunable laser and a swept-beam delivery approach. It irradiates a medium using a narrow laser beam sweeping at high repetition rate over the desired imaging area, in contrast to the conventional PA approach using broad beam illumination at a low repetition. One significant advantage of this approach is that the fundamental problem of decoupling local light absorption at a point from optical fluence at the same point can be solved. Here, we present a fluence compensation method and demonstrate its performance in phantom studies. We adopted analytic fluence models, extending diffusion theory for the case of a pencil beam obliquely incident on a medium, and developed robust methods to estimate medium optical parameters using PA measurements acquired from multiple irradiation positions. We conducted comprehensive simulation tests and phantom studies using well-known contrast-agents to validate the reliability of the fluence models and spectral corrections.
△ Less
Submitted 26 January, 2020;
originally announced January 2020.
-
On the use of deep neural networks in optical communications
Authors:
Sanjaya Lohani,
Erin M. Knutson,
Matthew O'Donnell,
Sean D. Huver,
Ryan T. Glasser
Abstract:
Information transfer rates in optical communications may be dramatically increased by making use of spatially non-Gaussian states of light. Here we demonstrate the ability of deep neural networks to classify numerically-generated, noisy Laguerre-Gauss modes of up to 100 quanta of orbital angular momentum with near-unity fidelity. The scheme relies only on the intensity profile of the detected mode…
▽ More
Information transfer rates in optical communications may be dramatically increased by making use of spatially non-Gaussian states of light. Here we demonstrate the ability of deep neural networks to classify numerically-generated, noisy Laguerre-Gauss modes of up to 100 quanta of orbital angular momentum with near-unity fidelity. The scheme relies only on the intensity profile of the detected modes, allowing for considerable simplification of current measurement schemes required to sort the states containing increasing degrees of orbital angular momentum. We also present results that show the strength of deep neural networks in the classification of experimental superpositions of Laguerre-Gauss modes when the networks are trained solely using simulated images. It is anticipated that these results will allow for an enhancement of current optical communications technologies.
△ Less
Submitted 23 May, 2018;
originally announced June 2018.
-
Impact of surface functionalisation on the quantum coherence of nitrogen vacancy centres in nanodiamond
Authors:
R. G. Ryan,
A. Stacey,
K. M. O'Donnell,
T. Ohshima,
B. C. Johnson,
L. C. L. Hollenberg,
P. Mulvaney,
D. A. Simpson
Abstract:
Nanoscale quantum probes such as the nitrogen-vacancy centre in diamond have demonstrated remarkable sensing capabilities over the past decade as control over the fabrication and manipulation of these systems has evolved. However, as the size of these nanoscale quantum probes is reduced, the surface termination of the host material begins to play a prominent role as a source of magnetic and electr…
▽ More
Nanoscale quantum probes such as the nitrogen-vacancy centre in diamond have demonstrated remarkable sensing capabilities over the past decade as control over the fabrication and manipulation of these systems has evolved. However, as the size of these nanoscale quantum probes is reduced, the surface termination of the host material begins to play a prominent role as a source of magnetic and electric field noise. In this work, we show that borane-reduced nanodiamond surfaces can on average double the spin relaxation time of individual nitrogen-vacancy centres in nanodiamonds when compared to the thermally oxidised surfaces. Using a combination of infra-red and x-ray absorption spectroscopy techniques, we correlate the changes in quantum relaxation rates with the conversion of sp2 carbon to C-O and C-H bonds on the diamond surface. These findings implicate double-bonded carbon species as a dominant source of spin noise for near surface NV centres and show that through tailored engineering of the surface, we can improve the quantum properties and magnetic sensitivity of these nanoscale probes.
△ Less
Submitted 22 April, 2018; v1 submitted 15 November, 2017;
originally announced November 2017.
-
A new method to reduce the statistical and systematic uncertainty of chance coincidence backgrounds measured with waveform digitizers
Authors:
J. M. O'Donnell
Abstract:
A new method for measuring chance-coincidence backgrounds during the collection of coincidence data is presented. The method relies on acquiring data with near-zero dead time, which is now realistic due to the increasing deployment of flash electronic-digitizer (waveform digitizer) techniques. An experiment designed to use this new method is capable of acquiring more coincidence data, and a much r…
▽ More
A new method for measuring chance-coincidence backgrounds during the collection of coincidence data is presented. The method relies on acquiring data with near-zero dead time, which is now realistic due to the increasing deployment of flash electronic-digitizer (waveform digitizer) techniques. An experiment designed to use this new method is capable of acquiring more coincidence data, and a much reduced statistical fluctuation of the measured background. A statistical analysis is presented, and used to derive a figure of merit for the new method. Factors of four improvement over other analyses are realistic. The technique is illustrated with preliminary data taken as part of a program to make new measurements of the prompt fission neutron spectra at Los Alamos Neutron Science Center. It is expected that the these measurements will occur in a regime where the maximum figure of merit will be exploited.
△ Less
Submitted 18 November, 2016;
originally announced November 2016.