-
Design of the Global Reconstruction Logic in the Belle II Level-1 Trigger system
Authors:
Y. -T. Lai,
T. Koga,
Y. Iwasaki,
Y. Ahn,
H. Bae,
M. Campajola,
B. G. Cheon,
H. -E. Cho,
T. Ferber,
I. Haide,
G. Heine,
C. -L. Hsu,
C. Kiesling,
C. -H. Kim,
J. B. Kim,
K. Kim,
S. H. Kim,
I. S. Lee,
M. J. Lee,
Y. P. Liao,
J. Lin,
A. Little,
H. K. Moon,
H. Nakazawa,
M. Neu
, et al. (10 additional authors not shown)
Abstract:
The Belle~II experiment is designed to search for physics beyond the Standard Model by investigating rare decays at the SuperKEKB \(e^{+}e^{-}\) collider. Owing to the significant beam background at high luminosity, the data acquisition system employs a hardware-based Level-1~Trigger to reduce the readout data throughput by selecting collision events of interest in real time. The Belle~II Level-1~…
▽ More
The Belle~II experiment is designed to search for physics beyond the Standard Model by investigating rare decays at the SuperKEKB \(e^{+}e^{-}\) collider. Owing to the significant beam background at high luminosity, the data acquisition system employs a hardware-based Level-1~Trigger to reduce the readout data throughput by selecting collision events of interest in real time. The Belle~II Level-1~Trigger system utilizes FPGAs to reconstruct various detector observables from the raw data for trigger decision-making. The Global Reconstruction Logic receives these processed observables from four sub-trigger systems and provides a global summary for the final trigger decision. Its logic encompasses charged particle tracking, matching between sub-triggers, and the identification of special event topologies associated with low-multiplicity decays. This article discusses the hardware devices, FPGA firmware, integration with peripheral systems, and the design and performance of the trigger algorithms implemented within the Global Reconstruction Logic.
△ Less
Submitted 3 March, 2025;
originally announced March 2025.
-
The Belle II Detector Upgrades Framework Conceptual Design Report
Authors:
H. Aihara,
A. Aloisio,
D. P. Auguste,
M. Aversano,
M. Babeluk,
S. Bahinipati,
Sw. Banerjee,
M. Barbero,
J. Baudot,
A. Beaubien,
F. Becherer,
T. Bergauer,
F. U. Bernlochner.,
V. Bertacchi,
G. Bertolone,
C. Bespin,
M. Bessner,
S. Bettarini,
A. J. Bevan,
B. Bhuyan,
M. Bona,
J. F. Bonis,
J. Borah,
F. Bosi,
R. Boudagga
, et al. (186 additional authors not shown)
Abstract:
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive wit…
▽ More
We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.
△ Less
Submitted 4 July, 2024; v1 submitted 26 June, 2024;
originally announced June 2024.
-
Intermodular Configuration Scrubbing of On-detector FPGAs for the ARICH at Belle II
Authors:
R. Giordano,
Y. Lai,
S. Korpar,
R. Pestotnik,
A. Lozar,
L. Santelj,
M. Shoji,
S. Nishida
Abstract:
On-detector digital electronics in High-Energy Physics experiments is increasingly being implemented by means of SRAM-based FPGA, due to their capabilities of reconfiguration, real-time processing and multi-gigabit data transfer. Radiation-induced single event upsets in the configuration hinder the correct operation, since they may alter the programmed routing paths and logic functions. In most tr…
▽ More
On-detector digital electronics in High-Energy Physics experiments is increasingly being implemented by means of SRAM-based FPGA, due to their capabilities of reconfiguration, real-time processing and multi-gigabit data transfer. Radiation-induced single event upsets in the configuration hinder the correct operation, since they may alter the programmed routing paths and logic functions. In most trigger and data acquisition systems, data from several front-end modules are concentrated into a single board, which then transmits data to back-end electronics for acquisition and triggering. Since the front-end modules are identical, they host identical FPGAs, which are programmed with the same bitstream. In this work, we present a novel scrubber capable of correcting radiation-induced soft-errors in the configuration of SRAM-based FPGAs by majority voting across different modules. We show an application of this system to the read-out electronics of the Aerogel Ring Imaging CHerenkov (ARICH) subdetector of the Belle2 experiment at SuperKEKB of the KEK laboratory (Tsukuba, Japan). We discuss the architecture of the system and its implementation in a Virtex-5 LX50T FPGA, in the concentrator board, for correcting the configuration of up to six Spartan-6 LX45 FPGAs, on pertaining front-end modules. We discuss results from fault-injection and neutron irradiation tests at the TRIGA reactor of the Jozef Stefan Institute (Ljubljana, Slovenia) and we compare the performance of our solution to the Xilinx Soft Error Mitigation controller.
△ Less
Submitted 30 October, 2020;
originally announced October 2020.
-
Performance evaluation of the aerogel RICH counter for the Belle II spectrometer using early beam collision data
Authors:
M. Yonenaga,
I. Adachi,
L. Burmistrov,
F. Le Diberder,
T. Iijima,
S. Iwata,
S. Kakimoto,
H. Kakuno,
G. Karyan,
H. Kawai,
T. Kawasaki,
H. Kindo,
H. Kitamura,
M. Kobayashi,
T. Kohriki,
T. Konno,
S. Korpar,
P. Križan,
T. Kumita,
K. Kuze,
Y. Lai,
M. Mrvar,
G. Nazaryan,
S. Nishida,
M. Nishimura
, et al. (10 additional authors not shown)
Abstract:
The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluat…
▽ More
The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluate the performance of the ARICH counter using early beam collision data. Event samples of $D^{\ast +} \to D^0 π^+ (D^0 \to K^-π^+)$ were used to determine the $π(K)$ efficiency and the $K(π)$ misidentification probability. We found that the ARICH counter is capable of separating kaons from pions with an identification efficiency of $93.5 \pm 0.6 \, \%$ at a pion misidentification probability of $10.9 \pm 0.9 \, \%$. This paper describes the identification method of the counter and the evaluation of the performance during its early operation.
△ Less
Submitted 14 August, 2020;
originally announced August 2020.
-
Particle identification performance of the prototype Aerogel RICH counter for the Belle II experiment
Authors:
S. Iwata,
I. Adachi,
K. Hara,
T. Iijima,
H. Ikeda,
H. Kakuno,
H. Kawai,
T. Kawasaki,
S. Korpar,
P. Krizan,
T. Kumita,
S. Nishida,
S. Ogawa,
R. Pestotnik,
L. Šantelj,
A. Seljak,
M. Tabata,
E. Tahirović,
Y. Yusa
Abstract:
We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons, Hybrid Avalanche Photo-Detectors (HAPDs) are used. The designed HAPD has a high sensitivity to single photons under a strong magnetic field. We have confirmed t…
▽ More
We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons, Hybrid Avalanche Photo-Detectors (HAPDs) are used. The designed HAPD has a high sensitivity to single photons under a strong magnetic field. We have confirmed that the HAPD provides high efficiency for single-photon detection even after exposure to neutron and gamma-ray radiation that exceeds the levels expected in the 10-year Belle II operation. In order to confirm the basic performance of the ARICH counter system, we carried out a beam test at the DESY using a prototype of the ARICH counter with six HAPD modules. The results are in agreement with our expectations and confirm the suitability of the ARICH counter for the Belle II experiment. Based on the in-beam performance of the device, we expect that the identification efficiency at 3.5 GeV/c is 97.4% and 4.9% for pions and kaons, respectively. This paper summarizes the development of the HAPD for the ARICH and the evaluation of the performance of the prototype ARICH counter built with the final design components.
△ Less
Submitted 8 March, 2016;
originally announced March 2016.
-
Recent progress in the development of large area silica aerogel for use as RICH radiator in the Belle II experiment
Authors:
Makoto Tabata,
Ichiro Adachi,
Hideyuki Kawai,
Shohei Nishida,
Takayuki Sumiyoshi
Abstract:
We report recent progress in the development of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter to be installed in the forward end cap of the Belle II detector, which is currently being upgraded at the High Energy Accelerator Research Organization (KEK), Japan. The production of approximately 450 aerogel tiles with refractive…
▽ More
We report recent progress in the development of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter to be installed in the forward end cap of the Belle II detector, which is currently being upgraded at the High Energy Accelerator Research Organization (KEK), Japan. The production of approximately 450 aerogel tiles with refractive indices of either 1.045 or 1.055 was completed in May, 2014, and the tiles are now undergoing optical characterization. Installation of the aerogels was tested by installing them into a partial mock-up of the support structure.
△ Less
Submitted 16 November, 2014;
originally announced November 2014.
-
Silica aerogel radiator for use in the A-RICH system utilized in the Belle II experiment
Authors:
Makoto Tabata,
Ichiro Adachi,
Nao Hamada,
Koji Hara,
Toru Iijima,
Shuichi Iwata,
Hidekazu Kakuno,
Hideyuki Kawai,
Samo Korpar,
Peter Križan,
Tetsuro Kumita,
Shohei Nishida,
Satoru Ogawa,
Rok Pestotnik,
Luka Šantelj,
Andrej Seljak,
Takayuki Sumiyoshi,
Elvedin Tahirović,
Keisuke Yoshida,
Yosuke Yusa
Abstract:
This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward end cap of the Belle II detector. The proximity-focusing A-RICH system is especially designed to identify charged kaons and pions. The refractive index of the in…
▽ More
This paper presents recent progress in the development and mass production of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter, which will be installed in the forward end cap of the Belle II detector. The proximity-focusing A-RICH system is especially designed to identify charged kaons and pions. The refractive index of the installed aerogel Cherenkov radiators is approximately 1.05, and we aim for a separation capability exceeding 4$σ$ at momenta up to 4 GeV/$c$. Large-area aerogel tiles (over 18 $\times $ 18 $\times $ 2 cm$^3$) were first fabricated in test productions by pin drying in addition to conventional methods. We proposed to fill the large end-cap region (area 3.5 m$^2$) with 124 water-jet-trimmed fan-shaped dual-layer-focusing aerogel combinations of different refractive indices (1.045 and 1.055). Guided by the test production results, we decided to manufacture aerogels by the conventional method and are currently proceeding with mass production. In an electron beam test undertaken at the DESY, we confirmed that the $K$/$π$ separation capability of a prototype A-RICH counter exceeded 4$σ$ at 4 GeV/$c$.
△ Less
Submitted 17 June, 2014;
originally announced June 2014.
-
Belle II Technical Design Report
Authors:
T. Abe,
I. Adachi,
K. Adamczyk,
S. Ahn,
H. Aihara,
K. Akai,
M. Aloi,
L. Andricek,
K. Aoki,
Y. Arai,
A. Arefiev,
K. Arinstein,
Y. Arita,
D. M. Asner,
V. Aulchenko,
T. Aushev,
T. Aziz,
A. M. Bakich,
V. Balagura,
Y. Ban,
E. Barberio,
T. Barvich,
K. Belous,
T. Bergauer,
V. Bhardwaj
, et al. (387 additional authors not shown)
Abstract:
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr…
▽ More
The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.
△ Less
Submitted 1 November, 2010;
originally announced November 2010.
-
Measurements of Cherenkov Photons with Silicon Photomultipliers
Authors:
S. Korpar,
I. Adachi,
H. Chagani,
R. Dolenec,
K. Hara,
T. Iijima,
P. Krizan,
S. Nishida,
R. Pestotnik,
A. Stanovnik
Abstract:
A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which the…
▽ More
A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which the use of SiPMs, microchannel plate photomultiplier tubes or hybrid avalanche photodetectors, rather than traditional Photomultiplier Tubes (PMTs) is essential due to the presence of high magnetic fields. In both experiments, SiPMs are found to compare favourably with PMTs, with higher photon detection rates per unit area. Through the use of hemispherical and truncated pyramid light guides to concentrate photons onto the active surface area, the light yield increases significantly. An estimate of the contribution to dark noise from false coincidences between SiPMs in an array is also presented.
△ Less
Submitted 2 December, 2008;
originally announced December 2008.
-
A novel type of proximity focusing RICH counter with multiple refractive index aerogel radiator
Authors:
T. Iijima,
S. Korpar,
I. Adachi,
S. Fratina,
T. Fukushima,
A. Gorisek,
H. Kawai,
M. Konishi,
Y. Kozakai,
P. Krizan,
T. Matsumoto,
Y. Mazuka,
S. Nishida,
S. Ogawa,
S. Ohtake,
R. Pestotnik,
S. Saitoh,
T. Seki,
T. Sumiyoshi,
Y. Uchida,
Y. Unno,
S. Yamamoto
Abstract:
A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index aerogel radiator allows for an increase in Cherenkov photon yield on account of the increase in overall radiator thickness, while avoiding the simultaneous degrada…
▽ More
A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index aerogel radiator allows for an increase in Cherenkov photon yield on account of the increase in overall radiator thickness, while avoiding the simultaneous degradation in single photon angular resolution associated with the increased uncertainty of the emission point. With the refractive index of consecutive layers suitably increasing in the downstream direction, one may achieve overlapping of the Cherenkov rings from a single charged particle. In the opposite case of decreasing refractive index, one may obtain well separated rings. In the former combination an approximately 40% increase in photon yield is accompanied with just a minor degradation in single photon angular resolution. The impact of this improvement on the pion/kaon separation at the upgraded Belle detector is discussed.
△ Less
Submitted 29 April, 2005;
originally announced April 2005.