Offset geometry for extended field-of-view in multi-contrast and multi-scale X-ray microtomography of lung cancer lobectomy specimens
Authors:
Harry Allan,
Adam Doherty,
Carlos Navarrete-León,
Oriol Roche i Morgó,
Yunpeng Jia,
Charlotte Percival,
Zoe Hagel,
Kate E J Otter,
Chuen Ryan Khaw,
Kate Gowers,
Helen Hall,
Sam M Janes,
Fleur Monk,
David Moore,
Joseph Jacob,
Marco Endrizzi
Abstract:
X-ray microtomography is a powerful non-destructive technique allowing 3D virtual histology of resected human tissue. The achievable imaging field-of-view, is however limited by the fixed number of detector elements, enforcing the requirement to sacrifice spatial resolution in order to image larger samples. In applications such as soft-tissue imaging, phase-contrast methods are often employed to e…
▽ More
X-ray microtomography is a powerful non-destructive technique allowing 3D virtual histology of resected human tissue. The achievable imaging field-of-view, is however limited by the fixed number of detector elements, enforcing the requirement to sacrifice spatial resolution in order to image larger samples. In applications such as soft-tissue imaging, phase-contrast methods are often employed to enhance image contrast. Some of these methods, especially those suited to laboratory sources, rely on optical elements, the dimensions of which can impose a further limitation on the field-of-view. We describe an efficient method to double the maximum field-of-view of a cone-beam X-ray microtomography system, without sacrificing on spatial resolution, and including multi-contrast capabilities. We demonstrate an experimental realisation of the method, achieving exemplary reconstructions of a resected human lung sample, with a cubic voxel of 10.5 $μ$m linear dimensions, across a horizontal field-of-view of 4.3 cm. The same concepts are applied to free-space propagation imaging of a 2.7 mm segment of the same sample, achieving a cubic voxel of 450 nm linear dimensions. We show that the methodology can be applied at a range of different length-scales and geometries, and that it is directly compatible with complementary implementations of X-ray phase-contrast imaging.
△ Less
Submitted 14 February, 2025;
originally announced February 2025.
-
High angular sensitivity X-ray phase-contrast microtomography of soft-tissue through a two-directional beam-tracking synchrotron set-up
Authors:
Carlos Navarrete-Leon,
P. Stephen Patrick,
Adam Doherty,
Harry Allan,
Silvia Cipiccia,
Shashidhara Marathe,
Kaz Wanelik,
Michela Esposito,
Charlotte K. Hagen,
Alessandro Olivo,
Marco Endrizzi
Abstract:
Two-directional beam-tracking (2DBT) is a method for phase-contrast imaging and tomography that uses an intensity modulator to structure the X-ray beam into an array of independent circular beamlets that are resolved by a high-resolution detector. It features isotropic spatial resolution, provides two-dimensional phase sensitivity, and enables the three-dimensional reconstructions of the refractiv…
▽ More
Two-directional beam-tracking (2DBT) is a method for phase-contrast imaging and tomography that uses an intensity modulator to structure the X-ray beam into an array of independent circular beamlets that are resolved by a high-resolution detector. It features isotropic spatial resolution, provides two-dimensional phase sensitivity, and enables the three-dimensional reconstructions of the refractive index decrement, $δ$, and the attenuation coefficient, $μ$. In this work, we report on the angular sensitivity and the spatial resolution of 2DBT images in a synchrotron-based implementation. In its best configuration, we obtained angular sensitivities of $\sim$20 $n$rad and spatial resolution of at least 6.25 $μ$m in phase-contrast images. We also demonstrate exemplar application to the three-dimensional imaging of soft tissue samples, including a mouse liver and a decellularised porcine dermis.
△ Less
Submitted 15 December, 2023;
originally announced December 2023.
-
Direct x-ray scattering signal measurements in edge-illumination/beam-tracking imaging and their interplay with the variance of the refraction signals
Authors:
Ian Buchanan,
Silvia Cipiccia,
Carlo Peiffer,
Carlos Navarrete-León,
Alberto Astolfo,
Tom Partridge,
Michela Esposito,
Luca Fardin,
Alberto Bravin,
Charlotte K Hagen,
Marco Endrizzi,
Peter RT Munro,
David Bate,
Alessandro Olivo
Abstract:
X-ray dark-field or ultra-small angle scatter imaging has become increasingly important since the introduction of phase-based x-ray imaging and is having transformative impact in fields such as in vivo lung imaging and explosives detection. Here we show that dark-field images acquired with the edge-illumination method (either in its traditional double mask or simplified single mask implementation)…
▽ More
X-ray dark-field or ultra-small angle scatter imaging has become increasingly important since the introduction of phase-based x-ray imaging and is having transformative impact in fields such as in vivo lung imaging and explosives detection. Here we show that dark-field images acquired with the edge-illumination method (either in its traditional double mask or simplified single mask implementation) provide a direct measurement of the scattering function, which is unaffected by system-specific parameters such as the autocorrelation length. We show that this is a consequence both of the specific measurement setup and of the mathematical approach followed to retrieve the dark-field images. We show agreement with theoretical models for datasets acquired both with synchrotron and laboratory x-ray sources. We also introduce a new contrast mechanism, the variance of refraction, which is extracted from the same dataset and provides a direct link with the size of the scattering centres. We show that this can also be described by the same theoretical models. We study the behaviour of both signals vs. key parameters such as x-ray energy and scatterer radius. We find this allows quantitative, direct, multi-scale scattering measurements during imaging, with implications in all fields where dark-field imaging is used.
△ Less
Submitted 12 July, 2023;
originally announced July 2023.
-
X-ray phase-contrast micro tomography of soft tissues using a compact laboratory system with two-directional sensitivity
Authors:
Carlos Navarrete-Leon,
Adam Doherty,
Savvas Savvidis,
Mattia F. M. Gerli,
Giovanni Piredda,
Alberto Astolfo,
Silvia Cipiccia,
David Bate,
Charlotte K. Hagen,
Alessandro Olivo,
Marco Endrizzi
Abstract:
X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research. Phase-contrast imaging extends the domain of application of X-ray micro tomography to classes of samples that exhibit weak attenuation, thus appear with poor contrast i…
▽ More
X-ray micro tomography is a non-destructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology and medical research. Phase-contrast imaging extends the domain of application of X-ray micro tomography to classes of samples that exhibit weak attenuation, thus appear with poor contrast in standard X-ray imaging. Notable examples are low-atomic-number materials, like carbon-fibre composites, soft matter and biological soft tissues. We report on a compact and cost effective system for X-ray phase-contrast micro tomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed X-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard X-ray detector technologies: single-photon-counting offers higher sensitivity whereas flat-panels are preferred for a larger field of view. The system is benchmarked against known-material phantoms and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet oesophagus and a rat heart.
△ Less
Submitted 15 December, 2022;
originally announced December 2022.