Is the protactinium(V) mono-oxo bond weaker than what we thought?
Authors:
Tamara Shaaban,
Hanna Oher,
Jean Aupiais,
Julie Champion,
André Severo Pereira Gomes,
Claire Le Naour,
Melody Maloubier,
Florent Réal,
Eric Renault,
Xavier Rocquefelte,
Bruno Siberchicot,
Valérie Vallet,
Rémi Maurice
Abstract:
The bond distance is the simplest and most obvious indicator of the nature of a given chemical bond. However, for rare chemistry, it may happen that it is not yet firmly established. In this communication, we will show that the formally-triple protactinium(V) mono-oxo bond is predicted longer than what was previously reported in the solid state and in solution, based on robust quantum mechanical c…
▽ More
The bond distance is the simplest and most obvious indicator of the nature of a given chemical bond. However, for rare chemistry, it may happen that it is not yet firmly established. In this communication, we will show that the formally-triple protactinium(V) mono-oxo bond is predicted longer than what was previously reported in the solid state and in solution, based on robust quantum mechanical calculations, supported by an extensive methodological study. Furthermore, additional calculations are used to demonstrate that the Pa-Ooxo bond of interest is more sensitive to complexation than the supposedly analogous U-Oyl ones, not only in terms of bond distance but also of finer bond descriptors associated with the effective bond multiplicity.
△ Less
Submitted 7 October, 2024; v1 submitted 2 September, 2024;
originally announced September 2024.
Recoil Proton Telescopes and Parallel Plate Avalanche Counters for the $^{235}$U(n,f) cross section measurement relative to H(n,n)H between 10 and 450 MeV neutron energy
Authors:
A. Manna,
E. Pirovano,
O. Aberle,
S. Amaducci,
M. Barbagallo,
D. M. Castelluccio,
N. Colonna,
P. Console Camprini,
L. Cosentino,
M. Dietz,
Q. Ducasse,
P. Finocchiaro,
C. Le Naour,
S. Lo Meo,
M. Mastromarco,
C. Massimi,
A. Mengoni,
P. M. Milazzo,
F. Mingrone,
R. Nolte,
M. Piscopo,
D. Radeck,
M. Spelta,
L. Tassan-Got,
N. Terranova
, et al. (1 additional authors not shown)
Abstract:
With the aim of measuring the $^{235}$U(n,f) cross section at the n\_TOF facility at CERN over a wide neutron energy range, a detection system consisting of two fission detectors and three detectors for neutron flux determination was realized. The neutron flux detectors are Recoil Proton Telescopes (RPT), based on scintillators and solid state detectors, conceived to detect recoil protons from the…
▽ More
With the aim of measuring the $^{235}$U(n,f) cross section at the n\_TOF facility at CERN over a wide neutron energy range, a detection system consisting of two fission detectors and three detectors for neutron flux determination was realized. The neutron flux detectors are Recoil Proton Telescopes (RPT), based on scintillators and solid state detectors, conceived to detect recoil protons from the neutron-proton elastic scattering reaction. This system, along with a fission chamber and an array of parallel plate avalanche counters for fission event detection, was installed for the measurement at the n\_TOF facility in 2018, at CERN.
An overview of the performances of two RPTs - especially developed for this measurement - and of the parallel plate avalanche counters are described in this article. In particular, the characterization in terms of detection efficiency by Monte Carlo simulations and response to neutron beam, the study of the background, dead time correction and characterization of the samples, are reported. The results of the present investigation show that the performances of these detectors are suitable for accurate measurements of fission reaction cross sections in the range from 10 to 450~MeV.
△ Less
Submitted 18 January, 2023; v1 submitted 22 November, 2022;
originally announced November 2022.