-
Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam
Authors:
Irene Dutta,
Christopher Madrid,
Ryan Heller,
Shirsendu Nanda,
Danush Shekar,
Claudio San Martín,
Matías Barría,
Artur Apresyan,
Zhenyu Ye,
William K. Brooks,
Wei Chen,
Gabriele D'Amen,
Gabriele Giacomini,
Alessandro Tricoli,
Aram Hayrapetyan,
Hakseong Lee,
Ohannes Kamer Köseyan,
Sergey Los,
Koji Nakamura,
Sayuka Kita,
Tomoka Imamura,
Cristían Peña,
Si Xie
Abstract:
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attaina…
▽ More
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20 $μ$m-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50 $μ$m-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n$^{+}$ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.
△ Less
Submitted 20 January, 2025; v1 submitted 13 July, 2024;
originally announced July 2024.
-
ETROC1: The First Full Chain Precision Timing Prototype ASIC for CMS MTD Endcap Timing Layer Upgrade
Authors:
Xing Huang,
Quan Sun,
Datao Gong,
Piljun Gwak,
Doyeong Kim,
Jongho Lee,
Chonghan Liu,
Tiankuan Liu,
Tiehui Liu,
Sergey Los,
Sandeep Miryala,
Shirsendu Nanda,
Jamieson Olsen,
Hanhan Sun,
Jinyuan Wu,
Jingbo Ye,
Zhenyu Ye,
Li Zhang,
Wei Zhang
Abstract:
We present the design and characterization of the first full chain precision timing prototype ASIC, named ETL Readout Chip version 1 (ETROC1) for the CMS MTD endcap timing layer (ETL) upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors to detect charged particles, with the goal to achieve a time resolution of 40 - 50 ps per hit, and 30 - 40 ps per track with hits from two detector la…
▽ More
We present the design and characterization of the first full chain precision timing prototype ASIC, named ETL Readout Chip version 1 (ETROC1) for the CMS MTD endcap timing layer (ETL) upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors to detect charged particles, with the goal to achieve a time resolution of 40 - 50 ps per hit, and 30 - 40 ps per track with hits from two detector layers. The ETROC1 is composed of a 5 x 5 pixel array and peripheral circuits. The pixel array includes a 4 x 4 active pixel array with an H-tree shaped network delivering clock and charge injection signals. Each active pixel is composed of various components, including a bump pad, a charge injection circuit, a pre-amplifier, a discriminator, a digital-to-analog converter, and a time-to-digital converter. These components play essential roles as the front-end link in processing LGAD signals and measuring timing-related information. The peripheral circuits provide clock signals and readout functionalities. The size of the ETROC1 chip is 7 mm x 9 mm. ETROC1 has been fabricated in a 65 nm CMOS process, and extensively tested under stimuli of charge injection, infrared laser, and proton beam. The time resolution of bump-bonded ETROC1 + LGAD chipsets reaches 42 - 46 ps per hit in the beam test.
△ Less
Submitted 2 September, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam
Authors:
Christopher Madrid,
Ryan Heller,
Claudio San Martín,
Shirsendu Nanda,
Artur Apresyan,
William K. Brooks,
Wei Chen,
Gabriele Giacomini,
Ohannes Kamer Köseyan,
Sergey Los,
Cristián Peña,
René Rios,
Alessandro Tricoli,
Si Xie,
Zhenyu Ye
Abstract:
We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-bas…
▽ More
We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 micron and 32 ps resolutions from strips of 1 cm length and 500 micron pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.
△ Less
Submitted 20 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Unsteadiness in hypersonic leading-edge separation
Authors:
S. K. Karthick,
Soumya R. Nanda,
J. Cohen
Abstract:
Hypersonic leading-edge separation is studied towards understanding the varying shock-related unsteadiness with freestream Reynolds number ($1.66 \times 10^5 \leq Re_D \leq 5.85 \times 10^5$) in the newly constructed hypersonic Ludwieg tunnel (HLT) at a freestream design Mach number of $M_\infty=6.0$. An axisymmetric flat-face cylinder of base body diameter $D=35$ mm is fitted with protrusions of…
▽ More
Hypersonic leading-edge separation is studied towards understanding the varying shock-related unsteadiness with freestream Reynolds number ($1.66 \times 10^5 \leq Re_D \leq 5.85 \times 10^5$) in the newly constructed hypersonic Ludwieg tunnel (HLT) at a freestream design Mach number of $M_\infty=6.0$. An axisymmetric flat-face cylinder of base body diameter $D=35$ mm is fitted with protrusions of different fineness ($d/D=0.1,0.2,0.26,0.34$ at $L/D=1.4$) and slenderness ($L/D=0.7,1,1.4,1.9$ at $d/D=0.2$) ratio to induce a wide range of leading-edge separation intensities. Qualitative and quantitative assessments are made using schlieren imaging, planar laser Rayleigh scattering, and unsteady pressure measurements. A well-known to-and-fro shock motion called pulsation and a flapping shock-shear layer oscillation is observed as $Re_D$ changes. A shorter protrusion length ($L/D=0.7$) produces a pressure loading that is four orders higher than the cases with longer protrusion lengths. There exists a critical separation length ($L/D \geq 1.4$) beyond which the separated shear layer trips to turbulence and introduces fluctuations in the recirculation region as $Re_D$ increases. The effect of the separated turbulent shear layer is dampened by an order provided the reattachment angle is shallow by increasing the fineness ratio ($d/D=0.4$). There also exists a critical geometrical parameter ($L/D=1, d/D=0.2$) for which the unsteady modes switch between successive runs based on the upstream fluctuations. From the modal analysis of the Rayleigh scattering images, the first four dominant modes that drive flapping are identified as translatory flapping, sinuous flapping, large and small-scale shedding.
△ Less
Submitted 11 August, 2022;
originally announced August 2022.
-
On Spherical Shock Wave focusing in Air -- a Computational Study
Authors:
Saranyamol V. S.,
Soumya Ranjan Nanda,
Mohammed Ibrahim S
Abstract:
A detailed numerical study on the phenomenon of Shock Wave focusing in air is carried out. The focusing phenomenon is achieved with the help of a shock tube and a converging section attached to it. The planar shock generated inside the shock tube is converted to spherical shock with the help of the converging section and is focused to a point. High-temperature effects like temperature-dependent Cp…
▽ More
A detailed numerical study on the phenomenon of Shock Wave focusing in air is carried out. The focusing phenomenon is achieved with the help of a shock tube and a converging section attached to it. The planar shock generated inside the shock tube is converted to spherical shock with the help of the converging section and is focused to a point. High-temperature effects like temperature-dependent Cp variation and chemical reactions corresponding to dissociated air are included in the simulation. The chemical reactions including the dissociation, recombination and ionization of nine species of air including three ions (N2, O2, N, O, NO, Ar, NO+, O+ and Ar+) are monitored throughout the simulation. The effect of driven section filling conditions such as initial pressure and temperature on focusing parameters is studied. The variation in the initial fill temperature is found to affect the flow properties much more as compared to the change in initial fill pressure, while maintaining the same shock strength. The effect of incident shock strength on shock wave focusing is also investigated. It is observed that as the strength of the shock increases, the conditions like temperature and pressure at the focusing point increases and thereby increasing the reaction rate of all the reactions.
△ Less
Submitted 13 March, 2021;
originally announced March 2021.
-
On the unsteady dynamics of partially shrouded compressible jets
Authors:
Soumya R. Nanda,
S. K. Karthick,
T. V. Krishna,
A. De,
S. Mohammed Ibrahim
Abstract:
We experimentally investigate a partially shrouded sonic jet (a sonic free-jet shielded by a solid wall-extension on one side) exiting from a planar nozzle at two different nozzle pressure ratio ($ζ=4$ and $5$). We experimentally show that the inherent jet unsteadiness from the shock-induced flow separation on the wall and the emitted noise in the far-field is strongly coupled through a series of…
▽ More
We experimentally investigate a partially shrouded sonic jet (a sonic free-jet shielded by a solid wall-extension on one side) exiting from a planar nozzle at two different nozzle pressure ratio ($ζ=4$ and $5$). We experimentally show that the inherent jet unsteadiness from the shock-induced flow separation on the wall and the emitted noise in the far-field is strongly coupled through a series of experiments like high-speed schlieren, wall-static pressure, unsteady pressure spectra, and microphone measurements. The partially shrouded jet's lateral free expansion is also identified to be complicated, three-dimensional, and the produced noise is directional. The emitted acoustic pulses from the flapping-jet, the radiated noise from the shock-induced separation on the wall, and the shock-shear layer interaction on the other side of the wall are responsible for the generated acoustic disturbances. The non-uniform aeroacoustic forcing on the top and bottom portion of the partially wall-bounded jet shear layer leads to a self-sustained jet oscillation and a discrete sound emission. The vital features are identified through the proper orthogonal decomposition of high-speed schlieren images and supplemented by other measurements.
△ Less
Submitted 20 September, 2021; v1 submitted 14 February, 2021;
originally announced February 2021.
-
Photonics probing of DNA specific spatial mass density fluctuations in gut cell nuclei due to total body irradiation via confocal imaging
Authors:
Mehedi Hasan,
Pradeep Shukla,
Shirsendu Nanda,
Prakash Adhikari,
Radhakrishna Rao,
Prabhakar Pradhan
Abstract:
Abnormalities within cells result in nanoscale structural alterations can be characterized via confocal imaging and quantification of these alterations. Accidental or deliberate exposure to total body irradiation (TBI) have adverse effects on the nuclear DNAs of cells. Here, we study the DNA molecular mass density spatial structural alterations of chromatin in cell nuclei of gut tissues caused by…
▽ More
Abnormalities within cells result in nanoscale structural alterations can be characterized via confocal imaging and quantification of these alterations. Accidental or deliberate exposure to total body irradiation (TBI) have adverse effects on the nuclear DNAs of cells. Here, we study the DNA molecular mass density spatial structural alterations of chromatin in cell nuclei of gut tissues caused by the exposure to standard doses of 4Gy TBI, using the light localization technique called inverse participation ratio (IPR) in confocal images. Results indicate radiation suppresses DNA spatial mass density fluctuations. And hence, reduction and saturation in DNA density fluctuations are observed for different durations of post-irradiation.
△ Less
Submitted 2 June, 2020;
originally announced June 2020.
-
On the fluidic behavior of an over-expanded planar plug nozzle under lateral confinement
Authors:
M. Chaudhary,
T. V. Krishna,
Sowmya R. Nanda,
S. K. Karthick,
A. Khan,
A. De,
S. Mohammed Ibrahim
Abstract:
The present work aims to study the fluidic behavior on lateral confinement by placing side-walls on the planar plug nozzle through experiments. The study involves two cases of nozzle pressure ratio (NPR=3, 6), which correspond to over-expanded nozzle operating conditions. Steady-state pressure measurements, together with schlieren and surface oil flow visualization, reveal the presence of over-exp…
▽ More
The present work aims to study the fluidic behavior on lateral confinement by placing side-walls on the planar plug nozzle through experiments. The study involves two cases of nozzle pressure ratio (NPR=3, 6), which correspond to over-expanded nozzle operating conditions. Steady-state pressure measurements, together with schlieren and surface oil flow visualization, reveal the presence of over-expansion shock and subsequent interaction and modification of the flow field on the plug surface. The flow remains attached to the plug surface for NPR=3; whereas, for NPR=6, a separated flow field with a recirculation bubble is observed. Spectral analysis of the unsteady pressure signals illustrates a clear difference between the attached and the separated flow. Besides, other flow features with a distinct temporal mode associated with and without lateral confinement are observed. The absence of lateral confinement reduces the intensity of low-frequency unsteadiness; however, on the contrary, the interaction region is relatively reduced under lateral confinement.
△ Less
Submitted 2 August, 2020; v1 submitted 31 May, 2020;
originally announced June 2020.
-
Numerical study of the degree of light scattering strength versus fractal dimension in optical fractal disordered media: Applications in strong to weak disordered media
Authors:
Ethan R. Avery,
Peeyush Sahay,
Shirsendu Nanda,
Binod Regmi,
Prabhakar Pradhan
Abstract:
Optical scattering strength of fractal optical disordered media with varying fractal dimension is reported. The diffusion limited aggregation (DLA) technique is used to generate fractal samples in 2D and 3D, and fractal dimensions are calculated using the box-counting method. The degree of structural disorder of these samples are calculated using their light localization strength, using the invers…
▽ More
Optical scattering strength of fractal optical disordered media with varying fractal dimension is reported. The diffusion limited aggregation (DLA) technique is used to generate fractal samples in 2D and 3D, and fractal dimensions are calculated using the box-counting method. The degree of structural disorder of these samples are calculated using their light localization strength, using the inverse participation ratio (IPR) analyses of the optical eigenfunctions. Results show non-monotonous behavior of the disorder-induced scattering strength with the fractal dimension, attributed to the competition between increasing structural disorder due to decrease in fractality versus decrease in scattering centers due to decreasing fractality.
△ Less
Submitted 18 November, 2019; v1 submitted 27 December, 2018;
originally announced December 2018.
-
A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab
Authors:
A. Rakhman,
M. Hafez,
S. Nanda,
F. Benmokhtar,
A. Camsonne,
G. D. Cates,
M. M. Dalton,
G. B. Franklin,
M. Friend,
R. W. Michaels,
V. Nelyubin,
D. S. Parno,
K. D. Paschke,
B. P. Quinn,
P. A. Souder,
W. A. Tobias
Abstract:
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maxi…
▽ More
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maximum achieved green power at 5 W IR pump power is 1.74 W with a total conversion efficiency of 34.8\%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7~kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7\%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0\% precision in polarization measurements of an electron beam with energy and current of 1.0~GeV and 50~$μ$A.
△ Less
Submitted 29 March, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
Hall A Annual Report 2012
Authors:
S. Riordan,
C. Keppel,
K. Aniol,
J. Annand,
J. Arrington,
T. Averett,
C. Ayerbe Gayoso,
E. Brash,
G. D. Cates,
J. -P. Chen,
E. Chudakov,
D. Flay,
G. B. Franklin,
M. Friedman,
O. Glamazdin,
J. Gomez,
C. Hanretty,
J. -O. Hansen,
C. Hyde,
M. K. Jones,
I. Korover,
J. J. LeRose,
R. A. Lindgren,
N. Liyanage,
E. Long
, et al. (24 additional authors not shown)
Abstract:
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
Report over the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility.
△ Less
Submitted 18 February, 2013;
originally announced February 2013.
-
Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab
Authors:
M. Friend,
D. Parno,
F. Benmokhtar,
A. Camsonne,
M. Dalton,
G. B. Franklin,
V. Mamyan,
R. Michaels,
S. Nanda,
V. Nelyubin,
K. Paschke,
B. Quinn,
A. Rakhman,
P. Souder,
A. Tobias
Abstract:
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crysta…
▽ More
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.
△ Less
Submitted 24 August, 2011; v1 submitted 15 August, 2011;
originally announced August 2011.
-
Preliminary Results from Integrating Compton Photon Polarimetry in Hall A of Jefferson Lab
Authors:
D. Parno,
M. Friend,
F. Benmokhtar,
G. Franklin,
R. Michaels,
S. Nanda,
B. Quinn,
P. Souder
Abstract:
A wide range of nucleon and nuclear structure experiments in Jefferson Lab's Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a Fabry-Perot cavity; by measuring an asymmetry in the integrated signal of the scattered photons detected in a GSO crystal, we can make non-invasive, continuous meas…
▽ More
A wide range of nucleon and nuclear structure experiments in Jefferson Lab's Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a Fabry-Perot cavity; by measuring an asymmetry in the integrated signal of the scattered photons detected in a GSO crystal, we can make non-invasive, continuous measurements of the beam polarization. Our goal is to achieve 1% statistical error within two hours of running. We discuss the design and commissioning of an upgrade to this apparatus, and report preliminary results for experiments conducted at beam energies from 3.5 to 5.9 GeV and photon rates from 5 to 100 kHz.
△ Less
Submitted 23 June, 2011;
originally announced June 2011.