-
Temperature dependence of the probability of "small heating" and total losses of ucns on the surface of fomblin oils of different molecular mass
Authors:
S. M. Cherniavsky,
E. V. Lychagin,
A. Yu. Muzychka,
G. V. Nekhaev,
V. V. Nesvizhevsky,
S. Reynaud,
A. V. Strelkov,
K. Turlybekuly
Abstract:
We measured the temperature dependence of the probability of small heating and total losses of UCNs on the PFPE Fomblin Y surface with various molecular masses Mw=2800, 3300, 6500 amu in the temperature range of 100-300 K. The probability of small heating sharply decreases with increasing Mw and decreasing temperature. The probability of total loss weakly decreases with decreasing temperature and…
▽ More
We measured the temperature dependence of the probability of small heating and total losses of UCNs on the PFPE Fomblin Y surface with various molecular masses Mw=2800, 3300, 6500 amu in the temperature range of 100-300 K. The probability of small heating sharply decreases with increasing Mw and decreasing temperature. The probability of total loss weakly decreases with decreasing temperature and takes the minimum value at Mw=3300 amu. As this oil provides a homogeneous surface with minimal probabilities of small heating and total losses of UCNs, it is the preferred candidate for experiments on measuring the neutron lifetime.
△ Less
Submitted 5 April, 2019;
originally announced April 2019.
-
Temperature dependence of the probability of "small heating" and spectrum of UCNs up-scattered on the surface of Fomblin oil Y-HVAC 18/8
Authors:
V. V. Nesvizhevsky,
A. Yu. Voronin,
A. Lambrecht,
S. Reynaud,
E. V. Lychagin,
A. Yu. Muzychka,
G. V. Nekhaev,
A. V. Strelkov
Abstract:
We performed precision measurements of the probability of small heating and spectrum of UCNs up-scattered on the surface of hydrogen-free oil Fomblin Y-HVAC 18/8 as a function of temperature. The probability is well reproducible, does not depend on sample thickness and does not evolve in time. It is equal (9.8+-0.2)10^(-6) at the ambient temperature. The spectrum coincides with those measured with…
▽ More
We performed precision measurements of the probability of small heating and spectrum of UCNs up-scattered on the surface of hydrogen-free oil Fomblin Y-HVAC 18/8 as a function of temperature. The probability is well reproducible, does not depend on sample thickness and does not evolve in time. It is equal (9.8+-0.2)10^(-6) at the ambient temperature. The spectrum coincides with those measured with solid-surface and nanoparticle samples. Indirect arguments indicate that spectrum shape weakly depends on temperature. Measured experimental data can be satisfactory described both within the model of near-surface nanodroplets and the model of capillary waves.
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
UCN sources at external beams of thermal neutrons. An example of PIK reactor
Authors:
E. V. Lychagin,
V. A. Mityukhlyaev,
A. Yu. Muzychka,
G. V. Nekhaev,
V. V. Nesvizhevsky,
M. S. Onegin,
E. I. Sharapov,
A. V. Strelkov
Abstract:
We consider ultracold neutron (UCN) sources based on a new method of UCN production in superfluid helium (4He). The PIK reactor is chosen as a perspective example of the application of this idea, which consists of installing a 4He UCN source in a beam of thermal or cold neutrons and surrounding the source with a moderator-reflector, which plays the role of a source of cold neutrons (CNs) feeding t…
▽ More
We consider ultracold neutron (UCN) sources based on a new method of UCN production in superfluid helium (4He). The PIK reactor is chosen as a perspective example of the application of this idea, which consists of installing a 4He UCN source in a beam of thermal or cold neutrons and surrounding the source with a moderator-reflector, which plays the role of a source of cold neutrons (CNs) feeding the UCN source. The CN flux in the source can be several times larger than the incident flux, due to multiple neutron reflections from the moderator-reflector. We show that such a source at the PIK reactor would provide an order of magnitude larger density and production rate than an analogous source at the ILL reactor.
We estimate parameters of a 4He source with solid methane (CH4) or/and liquid deuterium (D2) moderator-reflector. We show that such a source with CH4 moderator-reflector at the PIK reactor would provide the UCN density of ~1x10^5 1/cm^3, and the UCN production rate of ~2x10^7 1/s. These values are respectively 1000 and 20 times larger than those for the most intense UCN user source. The UCN density in a source with D2 moderator-reflector would reach the value of ~2x10^5 1/cm^3, and the UCN production rate would be equal ~8x10^7 1/s. Installation of such sources in beams of CNs with equal flux would slightly increase the density and production rate.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.