-
Conceptual design of the Gas Injection and Vacuum System for DTT NBI
Authors:
P. Agostinetti,
S. Dal Bello,
F. Dinh,
A. Ferrara,
M. Fincato,
L. Grando,
M. Mura,
A. Murari,
E. Sartori,
M. Siragusa,
F. Siviero,
F. Veronese
Abstract:
The Divertor Tokamak Test (DTT) is a new experimental facility whose construction is starting in Frascati, Rome, Italy; its main goals are improving the understanding of plasma-wall interactions and supporting the development of ITER and DEMO. DTT will be equipped with a Neutral Beam Injector (NBI) based on negative deuterium ions, designed to inject 10 MW of power to the tokamak.
A fundamental…
▽ More
The Divertor Tokamak Test (DTT) is a new experimental facility whose construction is starting in Frascati, Rome, Italy; its main goals are improving the understanding of plasma-wall interactions and supporting the development of ITER and DEMO. DTT will be equipped with a Neutral Beam Injector (NBI) based on negative deuterium ions, designed to inject 10 MW of power to the tokamak.
A fundamental system for the good operations of the DTT NBI will be its Gas injection and Vacuum System (GVS). Indeed, the efficiency of the entire NBI strongly depends on the good performance of its GVS.
The GVS for DTT NBI will be composed of two systems working in parallel: a grounded section connected to the main vacuum vessel, and a high voltage part connected to the ion source vessel and working at -510 kV voltage. The grounded part will feature a fore vacuum system (given by screw and roots pumps) plus a high vacuum system based on turbo-molecular pumps located on the side walls of the vessel and Non-Evaporable Getter (NEG) pumps located inside the vessel on the upper and lower surfaces. On the other hand, the high voltage part will feature a fore vacuum system (given by two compact screw pumps mounted on the external surface for the ion source vessel) plus a high vacuum system based on turbo-molecular pumps also located on the sidewalls of the ion source vessel. A dedicated deuterium gas injection will feed the process gas to the ion source and the neutralizer.
This paper gives a description of the conceptual design of the GVS for DTT NBI, and of the procedure followed to optimize this system considering the operational requirements and the other constraints of the DTT NBI.
△ Less
Submitted 5 April, 2023; v1 submitted 30 March, 2023;
originally announced March 2023.
-
A new class of indicators for the model selection of scaling laws in nuclear fusion
Authors:
I. Lupelli,
A. Murari,
P. Gaudio,
M. Gelfusa,
D. Mazon,
J. Vega
Abstract:
The development of computationally efficient model selection strategies represents an important problem facing the analysis of Nuclear Fusion experimental data, in particular in the field of scaling laws for the extrapolation to future machines, and image processing. In this paper, a new model selection indicator, named Model Falsification Criterion (MFC), will be presented and applied to the prob…
▽ More
The development of computationally efficient model selection strategies represents an important problem facing the analysis of Nuclear Fusion experimental data, in particular in the field of scaling laws for the extrapolation to future machines, and image processing. In this paper, a new model selection indicator, named Model Falsification Criterion (MFC), will be presented and applied to the problem of choosing the most generalizable scaling laws for the power threshold to access the H-mode of confinement in Tokamaks. The proposed indicator is based on the properties of the model residuals, their entropy and an implementation of the data falsification principle. The model selection ability of the proposed criterion will be demonstrated in comparison with the most widely used frequentist (Akaike Information Criterion) and bayesian (Bayesian Information Criterion) indicators.
△ Less
Submitted 20 November, 2013;
originally announced November 2013.
-
Developement of real time diagnostics and feedback algorithms for JET in view of the next step
Authors:
A. Murari,
E. Joffrin,
R. Felton,
D. Mazon,
L. Zabeo,
R. Albanese,
P. Arena,
G. Ambrosino,
M. Ariola,
O. Barana,
M. Bruno,
L. Laborde,
D. Moreau,
F. Piccolo,
F. Sartori,
F. Crisanti,
E. De La Luna,
J. Sanchez
Abstract:
Real time control of many plasma parameters will be an essential aspect in the development of reliable high performance operation of Next Step Tokamaks. The main prerequisites for any feedback scheme are the precise real-time determination of the quantities to be controlled, requiring top quality and highly reliable diagnostics, and the availability of robust control algorithms. A new set of rea…
▽ More
Real time control of many plasma parameters will be an essential aspect in the development of reliable high performance operation of Next Step Tokamaks. The main prerequisites for any feedback scheme are the precise real-time determination of the quantities to be controlled, requiring top quality and highly reliable diagnostics, and the availability of robust control algorithms. A new set of real time diagnostics was recently implemented on JET to prove the feasibility of determining, with high accuracy and time resolution, the most important plasma quantities. With regard to feedback algorithms, new model–based controllers were developed to allow a more robust control of several plasma parameters. Both diagnostics and algorithms were successfully used in several experiments, ranging from H-mode plasmas to configuration with ITBs. Since elaboration of computationally heavy measurements is often required, significant attention was devoted to non-algorithmic methods like Digital or Cellular Neural/Nonlinear Networks. The real time hardware and software adopted architectures are also described with particular attention to their relevance to ITER.
△ Less
Submitted 19 October, 2004; v1 submitted 15 October, 2004;
originally announced October 2004.