-
A next-generation LHC heavy-ion experiment
Authors:
D. Adamová,
G. Aglieri Rinella,
M. Agnello,
Z. Ahammed,
D. Aleksandrov,
A. Alici,
A. Alkin,
T. Alt,
I. Altsybeev,
D. Andreou,
A. Andronic,
F. Antinori,
P. Antonioli,
H. Appelshäuser,
R. Arnaldi,
I. C. Arsene,
M. Arslandok,
R. Averbeck,
M. D. Azmi,
X. Bai,
R. Bailhache,
R. Bala,
L. Barioglio,
G. G. Barnaföldi,
L. S. Barnby
, et al. (374 additional authors not shown)
Abstract:
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with th…
▽ More
The present document discusses plans for a compact, next-generation multi-purpose detector at the LHC as a follow-up to the present ALICE experiment. The aim is to build a nearly massless barrel detector consisting of truly cylindrical layers based on curved wafer-scale ultra-thin silicon sensors with MAPS technology, featuring an unprecedented low material budget of 0.05% X$_0$ per layer, with the innermost layers possibly positioned inside the beam pipe. In addition to superior tracking and vertexing capabilities over a wide momentum range down to a few tens of MeV/$c$, the detector will provide particle identification via time-of-flight determination with about 20~ps resolution. In addition, electron and photon identification will be performed in a separate shower detector. The proposed detector is conceived for studies of pp, pA and AA collisions at luminosities a factor of 20 to 50 times higher than possible with the upgraded ALICE detector, enabling a rich physics program ranging from measurements with electromagnetic probes at ultra-low transverse momenta to precision physics in the charm and beauty sector.
△ Less
Submitted 2 May, 2019; v1 submitted 31 January, 2019;
originally announced February 2019.
-
ALICE Overwatch: Online monitoring and data quality assurance using HLT data
Authors:
R. J. Ehlers,
J. D. Mulligan
Abstract:
ALICE Overwatch is a project started in late 2015 to provide augmented online monitoring and data quality assurance utilizing time-stamped QA histograms produced by the ALICE High Level Trigger. The system receives the data via ZeroMQ, stores it for later review, enriches it with detector specific functionality, and visualizes it via a web application. These provided capabilities are complementary…
▽ More
ALICE Overwatch is a project started in late 2015 to provide augmented online monitoring and data quality assurance utilizing time-stamped QA histograms produced by the ALICE High Level Trigger. The system receives the data via ZeroMQ, stores it for later review, enriches it with detector specific functionality, and visualizes it via a web application. These provided capabilities are complementary to the existing Data Quality Monitoring system. In addition to basic visualization, additional processing options are accessible to the user, including requests for data within a particular time range or reprocessing of a particular run with different processing parameters. For example, the first ten minutes of a particular run could be investigated for a transient hot trigger channel.
Due to similarities between the Overwatch architecture and that which will be used for Quality Control (QC) in LHC Run 3 and beyond, Overwatch will also be utilized to develop and test various QC components during LHC Run 2. Some of the areas of QC development include a new trending and alarm framework. We report on the project's design, development, and status.
△ Less
Submitted 29 November, 2018;
originally announced December 2018.
-
Combination of two Gas Electron Multipliers and a Micromegas as gain elements for a time projection chamber
Authors:
S. Aiola,
R. J. Ehlers,
S. Gu,
J. W. Harris,
R. Majka,
J. D. Mulligan,
M. Oliver,
J. Schambach,
N. Smirnov
Abstract:
We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space charge in the drift volume of such detectors in order to eliminate the standard gating grid and its resultant dead time, while preserving good tracking and part…
▽ More
We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space charge in the drift volume of such detectors in order to eliminate the standard gating grid and its resultant dead time, while preserving good tracking and particle identification performance. We measured the positive ion back-flow and energy resolution at various element gains and electric fields, using a variety of gases, and additionally studied crosstalk effects and discharge rates. At a gain of 2000, this configuration achieves an ion back-flow below 0.4% and an energy resolution better than $σ/\text{E}=12\%$ for $^{55}$Fe X-rays.
△ Less
Submitted 28 March, 2016;
originally announced March 2016.
-
Simulations of a multi-layer extended gating grid
Authors:
J. D. Mulligan
Abstract:
A novel idea to control ion back-flow in time projection chambers is to use a multi-layer extended gating grid to capture back-flowing ions at the expense of live time and electron transparency. In this initial study, I perform simulations of a four-layer grid for the ALICE and STAR time projection chambers, using $\text{Ne}-\text{CO}_{2}\;(90-10)$ and $\text{Ar}-\text{CH}_{4}\;(90-10)$ gas mixtur…
▽ More
A novel idea to control ion back-flow in time projection chambers is to use a multi-layer extended gating grid to capture back-flowing ions at the expense of live time and electron transparency. In this initial study, I perform simulations of a four-layer grid for the ALICE and STAR time projection chambers, using $\text{Ne}-\text{CO}_{2}\;(90-10)$ and $\text{Ar}-\text{CH}_{4}\;(90-10)$ gas mixtures, respectively. I report the live time and electron transparency for both 90% and 99% ion back-flow suppression. Additionally, for the ALICE configuration I study several effects: using a mesh vs. wire-plane grid, including a magnetic field, and varying the over-voltage distribution in the gating region. For 90% ion back-flow suppression, I achieve 75% live time with 86% electron transparency for ALICE, and 95% live time with 83% electron transparency for STAR.
△ Less
Submitted 16 March, 2016;
originally announced March 2016.