-
Measurement and Calibration Approaches for Full Two-Port Scattering Parameters at mK Temperatures
Authors:
Luca Oberto,
Ehsan Shokrolahzade,
Emanuele Enrico,
Luca Fasolo,
Andrea Celotto,
Bernardo Galvano,
Alessandro Alocco,
Paolo Terzi,
Faisal A. Mubarak,
Marco Spirito
Abstract:
This paper describes the developed set-up and the characterization approaches to realize full two-port, calibrated scattering parameters measurements at cryogenic temperatures, providing a complete uncertainty budget. The system developed at the Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique, to realize error corrected cryogenic measurem…
▽ More
This paper describes the developed set-up and the characterization approaches to realize full two-port, calibrated scattering parameters measurements at cryogenic temperatures, providing a complete uncertainty budget. The system developed at the Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique, to realize error corrected cryogenic measurements with single cooling cycle. The system operates at temperatures down to the mK range, in the band 4-12 GHz in coaxial line. Calibration standards are referred to traceable room temperature measurements, while a numerical approach is used to evaluate the artifact response shift from room temperature values, and derive key information to enable full measurement uncertainty budget. Moreover, relevant measurement uncertainty contributions are evaluated according to internationally agreed procedures, and a comprehensive uncertainty budget is presented. Test measurements on a 20 dB attenuator are shown as an example. An attenuation value of 20.70 +/- 0.08 dB (95% confidence interval) was obtained at 6 GHz.
△ Less
Submitted 26 May, 2025;
originally announced May 2025.
-
Development and commissioning of a new readout system for the gas flow of the Belle II $K_L^0$ and muon detector
Authors:
Travis Applegate,
Noah Brenny,
Chunhui Chen,
Seema Choudhury,
James Cochran,
Shuaiyan Kang,
Avinash Khatri,
Haruki Kindo,
Tommy Lam,
Sayan Mitra,
Adil Mubarak,
Leo Piilonen,
Soeren Prell,
Michele Veronesi
Abstract:
We have designed and commissioned a new readout board to detect photosensor signals from gas-bubbler panels to continuously monitor the gas flow through the resistive plate chambers of the $K_L^0$ and muon detector of Belle II. The gas flow measurements have been integrated into Belle II's alarm system. The bubbler-monitoring system was first employed during the February 2024 to July 2024 Belle II…
▽ More
We have designed and commissioned a new readout board to detect photosensor signals from gas-bubbler panels to continuously monitor the gas flow through the resistive plate chambers of the $K_L^0$ and muon detector of Belle II. The gas flow measurements have been integrated into Belle II's alarm system. The bubbler-monitoring system was first employed during the February 2024 to July 2024 Belle II data-taking period.
△ Less
Submitted 31 March, 2025; v1 submitted 14 October, 2024;
originally announced October 2024.
-
The Notre-Dame Cube: An active-target time-projection chamber for radioactive beam experiments and detector development
Authors:
T. Ahn,
J. S. Randhawa,
S. Aguilar,
D. Blankstein,
L. Delgado,
N. Dixneuf,
S. L. Henderson,
W. Jackson,
L. Jensen,
S. Jin,
J. Koci,
J. J. Kolata,
J. Lai,
J. Levano,
X. Li,
A. Mubarak,
P. D. O'Malley,
S. Rameriz Martin,
M. Renaud,
M. Z. Serikow,
A. Tollefson,
J. Wilson,
L. Yan
Abstract:
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characte…
▽ More
Active-target detectors have the potential to address the difficulties associated with the low intensities of radioactive beams. We have developed an active-target detector, the Notre Dame Cube (ND-Cube), to perform experiments with radioactive beams produced at $\mathit{TwinSol}$ and to aid in the development of active-target techniques. Various aspects of the ND-Cube and its design were characterized. The ND-Cube was commissioned with a $^{7}$Li beam for measuring $^{40}$Ar + $^{7}$Li fusion reaction cross sections and investigating $^{7}$Li($α$,$α$)$^{7}$Li scattering events. The ND-Cube will be used to study a range of reactions using light radioactive ions produced at low energy.
△ Less
Submitted 23 June, 2021;
originally announced June 2021.