Quasi-Real Time Multi-Frequency 3D Shear Wave Absolute Vibro-Elastography (S-WAVE) System for Prostate
Authors:
Tajwar Abrar Aleef,
Julio Lobo,
Ali Baghani,
Hani Eskandari,
Hamid Moradi,
Robert Rohling,
S. Larry Goldenberg,
William James Morris,
S. Sara Mahdavi,
Septimiu E. Salcudean
Abstract:
This article describes a novel quasi-real time system for quantitative and volumetric measurement of tissue elasticity in the prostate. Tissue elasticity is computed by using a local frequency estimator to measure the three dimensional local wavelengths of a steady-state shear wave within the prostate gland. The shear wave is created using a mechanical voice coil shaker which transmits multi-frequ…
▽ More
This article describes a novel quasi-real time system for quantitative and volumetric measurement of tissue elasticity in the prostate. Tissue elasticity is computed by using a local frequency estimator to measure the three dimensional local wavelengths of a steady-state shear wave within the prostate gland. The shear wave is created using a mechanical voice coil shaker which transmits multi-frequency vibrations transperineally. Radio frequency data is streamed directly from a BK Medical 8848 trans-rectal ultrasound transducer to an external computer where tissue displacement due to the excitation is measured using a speckle tracking algorithm. Bandpass sampling is used that eliminates the need for an ultra fast frame rate to track the tissue motion and allows for accurate reconstruction at a sampling frequency that is below the Nyquist rate. A roll motor with computer control is used to rotate the sagittal array of the transducer and obtain the 3D data. Two CIRS phantoms were used to validate both the accuracy of the elasticity measurement as well as the functional feasibility of using the system for in vivo prostate imaging. The system has been used in two separate clinical studies as a method for cancer identification. The results, presented here, show numerical and visual correlations between our stiffness measurements and cancer likelihood as determined from pathology results. Initial published results using this system include an area under the receiver operating characteristic curve of 0.82+/-0.01 with regards to prostate cancer identification in the peripheral zone.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
Automatic dual air kerma strength treatment planning for focal low-dose-rate prostate brachytherapy boost using dosimetric and geometric constraints
Authors:
S. Sara Mahdavi,
Michael D. Peacock,
William J. Morris,
Ingrid T. Spadinger
Abstract:
Purpose: Automatic planning for focal low-dose-rate prostate brachytherapy (LDR-PB) boost.
Methods: A simulated annealing approach was utilized for creating automatic focal LDR-PB boost plans using both geometric (i.e. adherence of isodose contours to structure contours) and dosimetric constraints. In 46 patients, four unilateral focal lesion scenarios were considered as the boost region, in the…
▽ More
Purpose: Automatic planning for focal low-dose-rate prostate brachytherapy (LDR-PB) boost.
Methods: A simulated annealing approach was utilized for creating automatic focal LDR-PB boost plans using both geometric (i.e. adherence of isodose contours to structure contours) and dosimetric constraints. In 46 patients, four unilateral focal lesion scenarios were considered as the boost region, in the anterior/posterior and superior/inferior quadrants. Plans consisted of seeds with two air kerma strengths (0.740U and 0.351 or 0.354U) to achieve required dose coverage on these smaller focal targets. Plan characteristics (including PTV V100 and V150, Rectum V50, Urethra V150, and number of needles and seeds), were compared in terms of type of needle loading (dual vs. single air kerma needles), boost quadrant and prostate volume. Plans were blindly ranked on 20 consecutive cases by two experienced radiation oncologists.
Results: Differences in plans generated using the two needle loading techniques were not clinically significant, particularly in terms of the PTV V100 and V150 and Urethra V150, with single air kerma loaded needles potentially being more practical. A higher rectal dose was observed in the posterior boost quadrants (V50 >0.18), particularly in larger prostates (>40 cc). In smaller prostates (<25 cc), obtaining adequate dose coverage while sparing the urethra was more challenging. 88% of the plans were considered clinically acceptable without (46%) or with (mostly minor) modifications.
Conclusions: The novel approach of using dual air kerma seeds combined with geometric constraints within a simulated annealing-based automatic planning framework can lead to focal LDR-PB plans with high acceptability.
△ Less
Submitted 23 October, 2020;
originally announced October 2020.