-
The physics of oscillating surfaces and sounds
Authors:
Md Hossen Mondal,
Ramkrishna A. Joshi
Abstract:
The longitudinal oscillations of air columns composed of contractions and rarefaction make up sound. Sound amplification is widely used in medical, electronic and communication fields. A simplistic technique for producing and amplifying can be rewarding. In this study, we investigate a simplistic DIY speaker configuration that can be utilized for sound creation and modulation by implementing respo…
▽ More
The longitudinal oscillations of air columns composed of contractions and rarefaction make up sound. Sound amplification is widely used in medical, electronic and communication fields. A simplistic technique for producing and amplifying can be rewarding. In this study, we investigate a simplistic DIY speaker configuration that can be utilized for sound creation and modulation by implementing response of magnets and a solenoid to an oscillating input signal. We use steady state solution of forced simple harmonic oscillator with damping parameters to analyze our design and show its characteristic frequencies. We present an analytical way of obtaining optimal parameters of the setup to theoretically obtain experimental characteristic frequencies and provide an in-depth investigation of the setup.
△ Less
Submitted 5 February, 2025;
originally announced February 2025.
-
Study of Gas Electron Multiplier Detector Using ANSYS and GARFIELD$^{++}$
Authors:
Md Kaosor Ali Mondal,
Poojan Angiras,
Sachin Rana,
A. Sarkar
Abstract:
Micro-Pattern Gas Detectors (MPGDs) represent a category of gaseous ionization detectors that utilize microelectronics. They feature a remarkably small distance between the high potential difference anode and cathode electrodes and are typically filled with gases. When a high-energy particle interacts with the gas medium, it generates ions and electrons, which are subsequently accelerated in oppos…
▽ More
Micro-Pattern Gas Detectors (MPGDs) represent a category of gaseous ionization detectors that utilize microelectronics. They feature a remarkably small distance between the high potential difference anode and cathode electrodes and are typically filled with gases. When a high-energy particle interacts with the gas medium, it generates ions and electrons, which are subsequently accelerated in opposite directions due to the applied electric field. Deflected electrons trigger further ionization to create electron-ion pairs through an avalanche process. These particles can be detected with very high precision at the readout. The Gas Electron Multiplier (GEM) is one type of MPGD constructed with a polyimide film sandwiched between two conductors under a high voltage difference. Microscopic holes in the foil facilitate electron avalanche. However, the current geometry of the GEM detector used in various experiments is sub-optimal for the gain and performance. In this study, we have modified the geometry of the GEM detector to enhance the gain, reduce ions backflow, and enhance the performance of the detector. We are proposing a new geometry of the GEM detector foil for higher gain, better performance, and durability. For this study, the geometry has been constructed in ANSYS, and further studies have been performed using Garfield$^{++}$.
△ Less
Submitted 7 October, 2024;
originally announced October 2024.
-
Beam test of n-type Silicon pad array detector at PS CERN
Authors:
Sawan,
M. Bregant,
J. L. Bouly,
O. Bourrion,
A. van den Brink,
T. Chujo,
C. Krug,
L. Kumar,
V. K. S. Kashyap,
A. Ghimouz,
M. Inaba,
T. Isidori,
C. Loizides,
B. Mohanty,
M. M. Mondal,
N. Minafra,
N. Novitzky,
N. Ponchant,
M. Rauch,
K. P. Sharma,
R. Singh,
D. Thienpont,
D. Tourres,
G. Tambave
Abstract:
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored…
▽ More
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrmη$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored region of low momentum fraction x ($\mathrm{\sim10^{-5} - 10^{-6}}$). The prototype is a $\mathrm{8\times9}$ n-type Si pad array detector with each pad occupying one cm$^2$ area, fabricated on a 6-in, 325~$\mathrm{\pm 10 \thinspace μ}$m thick, and high-resistivity ($\sim$7 k$Ω\thinspace$ cm) Si wafer which is readout using HGCROCv2 chip. The detector is tested using pion beams of energy 10~GeV and electron beams of energy 1-5~GeV. The measurements of the Minimum Ionizing Particle (MIP) response of pions and the shower profiles of electrons are reported.
△ Less
Submitted 20 March, 2024;
originally announced March 2024.
-
Bakry-Émery-Ricci curvature: An alternative network geometry measure in the expanding toolbox of graph Ricci curvatures
Authors:
Madhumita Mondal,
Areejit Samal,
Florentin Münch,
Jürgen Jost
Abstract:
The characterization of complex networks with tools originating in geometry, for instance through the statistics of so-called Ricci curvatures, is a well established tool of network science. There exist various types of such Ricci curvatures, capturing different aspects of network geometry. In the present work, we investigate Bakry-Émery-Ricci curvature, a notion of discrete Ricci curvature that h…
▽ More
The characterization of complex networks with tools originating in geometry, for instance through the statistics of so-called Ricci curvatures, is a well established tool of network science. There exist various types of such Ricci curvatures, capturing different aspects of network geometry. In the present work, we investigate Bakry-Émery-Ricci curvature, a notion of discrete Ricci curvature that has been studied much in geometry, but so far has not been applied to networks. We explore on standard classes of artificial networks as well as on selected empirical ones to what the statistics of that curvature are similar to or different from that of other curvatures, how it is correlated to other important network measures, and what it tells us about the underlying network. We observe that most vertices typically have negative curvature. Random and small-world networks exhibit a narrow curvature distribution whereas other classes and most of the real-world networks possess a wide curvature distribution. When we compare Bakry-Émery-Ricci curvature with two other discrete notions of Ricci-curvature, Forman-Ricci and Ollivier-Ricci curvature for both model and real-world networks, we observe a high positive correlation between Bakry-Émery-Ricci and both Forman-Ricci and Ollivier-Ricci curvature, and in particular with the augmented version of Forman-Ricci curvature. Bakry-Émery-Ricci curvature also exhibits a high negative correlation with the vertex centrality measure and degree for most of the model and real-world networks. However, it does not correlate with the clustering coefficient. Also, we investigate the importance of vertices with highly negative curvature values to maintain communication in the network. The computational time for Bakry-Émery-Ricci curvature is shorter than that required for Ollivier-Ricci curvature but higher than for Augmented Forman-Ricci curvature.
△ Less
Submitted 9 February, 2024;
originally announced February 2024.
-
Optimizing Sorting of Micro-Sized Bio-Cells in Symmetric Serpentine Microchannel using Machine Learning
Authors:
Sayan Karmakar,
Md Safwan Mondal,
Anish Pal,
Sourav Sarkar
Abstract:
Efficient sorting of target cells is crucial for advancing cellular research in biology and medical diagnostics. Inertial microfluidics, an emerging technology, offers a promising approach for label-free particle sorting with high throughput. This paper presents a comprehensive study employing numerical computational fluid dynamics (CFD) simulations to investigate particle migration and sorting wi…
▽ More
Efficient sorting of target cells is crucial for advancing cellular research in biology and medical diagnostics. Inertial microfluidics, an emerging technology, offers a promising approach for label-free particle sorting with high throughput. This paper presents a comprehensive study employing numerical computational fluid dynamics (CFD) simulations to investigate particle migration and sorting within a symmetric serpentine microchannel. By adopting a Eulerian approach to solve fluid dynamics and a Lagrangian framework to track particles, the research explores the impact of flow Reynolds number and the number of loops in the serpentine channel on sorting efficiency. To generate a robust data-driven model, the authors performed CFD simulations for 200 combinations of randomly generated data points. The study leverages the collected data to develop a data-centric machine learning model capable of accurately predicting flow parameters for specific sorting efficiencies. Remarkably, the developed model achieved a 92% accuracy in predicting the Channel Reynolds Number during testing. However, it is worth noting that the model currently faces challenges in accurately predicting the required number of loops for efficient sorting.
△ Less
Submitted 3 August, 2023;
originally announced August 2023.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Nonlinear coherent light-matter interaction in 2D MoSe$_2$ nanoflakes for all-optical switching and logic applications
Authors:
Sk Kalimuddin,
Biswajit Das,
Nabamita Chakraborty,
Madhupriya Samanta,
Satyabrata Bera,
Arnab Bera,
Deep Singha Roy,
Suman Kalyan Pradhan,
Kalyan K. Chattopadhyay,
Mintu Mondal
Abstract:
We report a strong nonlinear optical response of 2D MoSe$_2$ nanoflakes (NFs) through spatial self-phase modulation (SSPM) and cross-phase modulation (XPM) induced by nonlocal coherent light-matter interactions. The coherent interaction of light and MoSe$_2$ NFs creates the SSPM of laser beams, forming concentric diffraction rings. The nonlinear refractive index ($n_2$) and the third-order broadba…
▽ More
We report a strong nonlinear optical response of 2D MoSe$_2$ nanoflakes (NFs) through spatial self-phase modulation (SSPM) and cross-phase modulation (XPM) induced by nonlocal coherent light-matter interactions. The coherent interaction of light and MoSe$_2$ NFs creates the SSPM of laser beams, forming concentric diffraction rings. The nonlinear refractive index ($n_2$) and the third-order broadband nonlinear optical susceptibility ($χ^{(3)}$) of MoSe$_2$ NFs are determined from the self diffraction pattern at different exciting wavelengths of 405, 532, and 671 nm with varying the laser intensity. The evolution and deformation of diffraction ring patterns are observed and analyzed by the `wind-chime' model and thermal effect. By taking advantage of the reverse saturated absorption of 2D SnS$_2$ NFs compared to MoSe$_2$, an all-optical diode has been designed with MoSe$_2$/SnS$_2$ hybrid structure to demonstrate the nonreciprocal light propagation. Also a few other optical devices based on MoSe$_2$ and other semiconducting materials such as Bi$_2$Se$_3$, CuPc, and graphene have been investigated. The all-optical logic gates and all-optical information conversion have been demonstrated through the XPM technique using two laser beams. The proposed optical scheme based on MoSe$_2$ NFs has been demonstrated as a potential candidate for all-optical nonlinear photonic devices such as all-optical diodes and all-optical switches.
△ Less
Submitted 25 June, 2022;
originally announced June 2022.
-
Optical microscope based universal parameter for identifying layer number in two-dimensional materials
Authors:
Mainak Mondal,
Ajit Kumar Dash,
Akshay Singh
Abstract:
Optical contrast is the most common preliminary method to identify layer number of two-dimensional (2D) materials, but is seldom used as a confirmatory technique. We explain the reason for variation of optical contrast between imaging systems. We introduce a universal method to quantify the layer number using the RGB (red-green-blue) and RAW optical images. For RGB images, the slope of 2D flake (M…
▽ More
Optical contrast is the most common preliminary method to identify layer number of two-dimensional (2D) materials, but is seldom used as a confirmatory technique. We explain the reason for variation of optical contrast between imaging systems. We introduce a universal method to quantify the layer number using the RGB (red-green-blue) and RAW optical images. For RGB images, the slope of 2D flake (MoS2, WSe2, graphene) intensity vs. substrate intensity is extracted from optical images with varying lamp power. The intensity slope identifies layer number and is system independent. For RAW images, intensity slopes and intensity ratios are completely system and intensity independent. Intensity slope (for RGB) and intensity ratio (for RAW) are thus universal parameters for identifying layer number. A Fresnel-reflectance-based optical model provides an excellent match with experiments. Further, we have created a MATLAB-based graphical user interface that can identify layer number rapidly. This technique is expected to accelerate the preparation of heterostructures, and fulfil a prolonged need for universal optical contrast method.
△ Less
Submitted 27 April, 2022;
originally announced April 2022.
-
Performance of a prototype bakelite RPC at GIF++ using self-triggered electronics for the CBM Experiment at FAIR
Authors:
Mitali Mondal,
Tanay Dey,
Subhasis Chattopadhyay,
Jogender Saini,
Zubayer Ahammed
Abstract:
The Muon Chamber (MuCh) is a sub-system of the Compressed Baryonic Matter (CBM) experiment for the detection of low-mass-vector mesons produced in high energy heavy-ion collisions at beam energies ranging from 2 AGeV to 11 AGeV and decaying in the di-muon channel. MuCh consists of a segmented absorber and four detector triplet stations sandwiched between the absorber segments. At the 3rd and 4th s…
▽ More
The Muon Chamber (MuCh) is a sub-system of the Compressed Baryonic Matter (CBM) experiment for the detection of low-mass-vector mesons produced in high energy heavy-ion collisions at beam energies ranging from 2 AGeV to 11 AGeV and decaying in the di-muon channel. MuCh consists of a segmented absorber and four detector triplet stations sandwiched between the absorber segments. At the 3rd and 4th stations of MuCh, Resistive Plate Chambers (RPCs) have been conceived for muon tracking. We have tested the performance of a low resistivity bakelite RPC prototype equipped with self-triggered front end electronics (MuCh-XYTER) for the CBM Muon Chamber. A systematic study on the muon detection efficiency and time resolution has been carried out in a high-rate photon background at the Gamma Irradiation Facility (GIF++) at CERN. The details of the measurement setup and the results are presented here.
△ Less
Submitted 3 January, 2022;
originally announced January 2022.
-
Coupling, lifetimes and "strong coupling" maps for single molecules at plasmonic interfaces
Authors:
Monosij Mondal,
Maicol A. Ochoa,
Maxim Sukharev,
Abraham Nitzan
Abstract:
The interaction between excited states of a molecule and excited states of metal nanostructure (e.g. plasmons) leads to hybrid states with modified optical properties. When plasmon resonance is swept through molecular transition frequency an avoided crossing may be observed, which is often regarded as a signature of strong coupling between plasmons and molecules. Such strong coupling is expected t…
▽ More
The interaction between excited states of a molecule and excited states of metal nanostructure (e.g. plasmons) leads to hybrid states with modified optical properties. When plasmon resonance is swept through molecular transition frequency an avoided crossing may be observed, which is often regarded as a signature of strong coupling between plasmons and molecules. Such strong coupling is expected to be realized when $2|U|/{\hbarΓ}>1$, where $U$ and $Γ$ are the molecule-plasmon coupling and the spectral width of the optical transition respectively. Because both $U$ and $Γ$ strongly increase with decreasing distance between a molecule and a plasmonic structure it is not obvious that this condition can be satisfied for any molecule-metal surface distance. In this work we investigate the behavior of $U$ and $Γ$ for several geometries. Surprisingly, we find that if the only contributions to $Γ$ are lifetime broadenings associated with the radiative and nonradiative relaxation of a single molecular vibronic transition, including effects on molecular radiative and nonradiative lifetimes induced by the metal, the criterion $2|U|/{\hbarΓ}>1$ is easily satisfied by many configurations irrespective of the metal-molecule distance. This implies that the Rabi splitting can be observed in such structures if other sources of broadening are suppressed. Additionally, when the molecule-metal surface distance is varied keeping all other molecular and metal parameters constant, this behavior is mitigated due to the spectral shift associated with the same molecule-plasmon interaction, making the observation of Rabi splitting more challenging.
△ Less
Submitted 5 November, 2021;
originally announced November 2021.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
A Proof-of-principle for Time-Of-Flight Positron Emission Tomography Imaging
Authors:
Rajesh Ganai,
Shaifali Mehta,
Mehulkumar Shiroya,
Mitali Mondal,
Zubayer Ahammed,
Subhasis Chattopadhyay
Abstract:
Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive Plate Chambers (MRPCs) are gaseous detectors which are easy to fabricate, inexpensive and have excellent position and timing resolution. They can be used as a suit…
▽ More
Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive Plate Chambers (MRPCs) are gaseous detectors which are easy to fabricate, inexpensive and have excellent position and timing resolution. They can be used as a suitable alternative to highly expensive scintillators. For the sole purpose of TOF-PET, a pair of 18 cm $\times$ 18 cm, 5 gap, glass-based MRPC modules have been fabricated. Our main aim was to determine the shift in the position of the source (Na-22) with these fabricated MRPCs. In this document, the details of the experimental results will be presented.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
Development and Characterization of 6-gap Bakelite Multi-gap Resistive Plate Chamber
Authors:
Rajesh Ganai,
Mitali Mondal,
Shaifali Mehta,
Zubayer Ahammed,
Subhasis Chattopadhyay
Abstract:
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged particles. They have found suitable applications in several high energy physics experiments like ALICE in LHC, CERN, Geneva, Switzerland, and STAR in RHIC, BNL, USA.…
▽ More
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged particles. They have found suitable applications in several high energy physics experiments like ALICE in LHC, CERN, Geneva, Switzerland, and STAR in RHIC, BNL, USA. As they have very good time resolution and are of low cost, they can be a suitable replacement for very expensive scintillators used in Positron Emission Tomography Imaging. The MRPCs that are being used nowadays are developed with glass electrodes. We have made an attempt to develop a 6-gap MRPC using bakelite electrodes. The outer electrodes are of dimensions 15 cm $\times$ 15 cm $\times$ 0.3 cm and the inner electrodes are of dimension 14 cm $\times$ 14 cm $\times$ 0.05 cm. The glossy finished electrode surfaces have not been treated with any oil like linseed, silicone for smoothness. The performance of the detector has been studied measuring the efficiency, noise rate and time resolution with cosmic rays. This effort is towards the development of a prototype for Positron Emission Tomography with the Time-Of-Flight technique using MRPCs. Details of the development procedure and performance studies have been presented here.
△ Less
Submitted 21 June, 2018;
originally announced June 2018.