3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm
Authors:
Artur Słomski,
Zbigniew Rudy,
Tomasz Bednarski,
Piotr Białas,
Eryk Czerwiński,
Łukasz Kapłon,
Andrzej Kochanowski,
Grzegorz Korcyl,
Jakub Kowal,
Paweł Kowalski,
Tomasz Kozik,
Wojciech Krzemień,
Marcin Molenda,
Paweł Moskal,
Szymon Niedźwiecki,
Marek Pałka,
Monika Pawlik,
Lech Raczyński,
Piotr Salabura,
Neha Gupta-Sharma,
Michał Silarski,
Jerzy Smyrski,
Adam Strzelecki,
Wojciech Wiślicki,
Marcin Zieliński
, et al. (1 additional authors not shown)
Abstract:
Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines connecting two detectors. As there is a multitude of detectors build-in typical PET tomograph structure, there are many possible detector pairs that pertain to th…
▽ More
Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines connecting two detectors. As there is a multitude of detectors build-in typical PET tomograph structure, there are many possible detector pairs that pertain to the measurement. The problem is how to turn this measurement into an image (this is called imaging). Decisive improvement in PET image quality was reached with the introduction of iterative reconstruction techniques. This stage was reached already twenty years ago (with the advent of new powerful computing processors). However, three dimensional (3D) imaging remains still a challenge. The purpose of the image reconstruction algorithm is to process this imperfect count data for a large number (many millions) of lines-of-responce (LOR) and millions of detected photons to produce an image showing the distribution of the labeled molecules in space.
△ Less
Submitted 26 April, 2015;
originally announced April 2015.
-
Plastic scintillators for positron emission tomography obtained by the bulk polymerization method
Authors:
Łukasz Kapłon,
Andrzej Kochanowski,
Marcin Molenda,
Paweł Moskal,
Anna Wieczorek,
Tomasz Bednarski,
Piotr Białas,
Eryk Czerwiński,
Grzegorz Korcyl,
Jakub Kowal,
Paweł Kowalski,
Tomasz Kozik,
Wojciech Krzemień,
Szymon Niedźwiecki,
Marek Pałka,
Monika Pawlik,
Lech Raczyński,
Zbigniew Rudy,
Piotr Salabura,
Neha Gupta-Sharma,
Michał Silarski,
Artur Słomski,
Jerzy Smyrski,
Adam Strzelecki,
Wojciech Wiślicki
, et al. (2 additional authors not shown)
Abstract:
This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing properties which fulfill the requirements of novel positron emission tomography scanners based on plastic scintillators. The key parameters of the manufacturing process are determined and discussed.
This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing properties which fulfill the requirements of novel positron emission tomography scanners based on plastic scintillators. The key parameters of the manufacturing process are determined and discussed.
△ Less
Submitted 26 April, 2015;
originally announced April 2015.
-
A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter
Authors:
A. Wieczorek,
P. Moskal,
Sz. Niedźwiecki,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Danel,
A. Gajos,
A. Gruntowski,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Molenda,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
P. Salabura,
N. G. Sharma
, et al. (8 additional authors not shown)
Abstract:
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the an…
▽ More
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.
△ Less
Submitted 4 July, 2015; v1 submitted 10 February, 2015;
originally announced February 2015.
-
Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
Authors:
L. Raczynski,
P. Moskal,
P. Kowalski,
W. Wislicki,
T. Bednarski,
P. Bialas,
E. Czerwinski,
L . Kaplon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
T. Kozik,
W. Krzemien,
E. Kubicz,
M. Molenda,
I. Moskal,
Sz. Niedzwiecki,
M. Palka,
M. Pawlik-Niedzwiecka,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Slomski,
J. Smyrski
, et al. (4 additional authors not shown)
Abstract:
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals…
▽ More
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps
△ Less
Submitted 31 July, 2014;
originally announced July 2014.
-
Test of a single module of the J-PET scanner based on plastic scintillators
Authors:
P. Moskal,
Sz. Niedźwiecki,
T. Bednarski,
E. Czerwiński,
Ł. Kapłon,
E. Kubicz,
I. Moskal,
M. Pawlik-Niedźwiecka,
N. G. Sharma,
M. Silarski,
M. Zieliński,
N. Zoń,
P. Białas,
A. Gajos,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
M. Pałka,
L. Raczyński,
Z. Rudy,
P. Salabura
, et al. (5 additional authors not shown)
Abstract:
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module bu…
▽ More
Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.
△ Less
Submitted 29 August, 2014; v1 submitted 28 July, 2014;
originally announced July 2014.
-
Determination of the map of efficiency of the J-PET detector with the GATE package
Authors:
P. Kowalski,
L. Raczyński,
T. Bednarski,
P. Białas,
E. Czerwiński,
K. Giergiel,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
T. Kozik,
W. Krzemień,
M. Molenda,
I. Moskal,
P. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki
, et al. (5 additional authors not shown)
Abstract:
A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.
A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.
△ Less
Submitted 27 February, 2014;
originally announced February 2014.
-
Database and data structure for the novel TOF-PET detector developed for J-PET project
Authors:
E. Czerwiński,
M. Zieliński,
T. Bednarski,
P. Białas,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Molenda,
P. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki
, et al. (3 additional authors not shown)
Abstract:
The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: regis…
▽ More
The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: registration process of the gamma quanta emitted from positron-electron annihilation, Front-End Electronic (FEE) structure and required input information for the image reconstruction. In addition, the system database fulfills possible demands of the evolving J-PET project.
△ Less
Submitted 17 February, 2014;
originally announced February 2014.
-
Computing support for advanced medical data analysis and imaging
Authors:
W. Wiślicki,
T. Bednarski,
P. Białas,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
P. Moskal,
S. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki,
A. Wieczorek
, et al. (2 additional authors not shown)
Abstract:
We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service architecture based on the grid and cloud concepts for distributed processing is proposed and critically discussed.
We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service architecture based on the grid and cloud concepts for distributed processing is proposed and critically discussed.
△ Less
Submitted 27 January, 2014;
originally announced January 2014.
-
Calibration of photomultipliers gain used in the J-PET detector
Authors:
T. Bednarski,
E. Czerwiński,
P. Moskal,
P. Białas,
K. Giergiel,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
I. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki
, et al. (5 additional authors not shown)
Abstract:
Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we de…
▽ More
Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we describe single photoelectron method used for photomultipliers calibration applied for J-PET scanner, a novel PET detector being developed at the Jagiellonian University. Description of calibration method, an example of calibration curve and gain of few R4998 Hamamatsu photomultipliers are presented.
△ Less
Submitted 16 December, 2013; v1 submitted 10 December, 2013;
originally announced December 2013.
-
Simulations of gamma quanta scattering in a single module of the J-PET detector
Authors:
K. Szymański,
P. Moskal,
T. Bednarski,
P. Białas,
E. Czerwiński,
K. Giergiel,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
I. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski
, et al. (5 additional authors not shown)
Abstract:
This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the…
▽ More
This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the scintillator strip with the cross section of 5 mm x 19 mm. Obtained results indicate that secondary interactions occur only in the case of about 8% of events and out of them only 25$\%$ take place in the distance larger than 0.5 cm from the primary interaction. It was also established that light signals produced at primary and secondary interactions overlap with the delay which distribution is characterized by FWHM of about 40 ps.
△ Less
Submitted 1 December, 2013;
originally announced December 2013.
-
J-PET analysis framework for the prototype TOF-PET detector
Authors:
W. Krzemień,
M. Silarski,
K. Stola,
D. Trybek,
T. Bednarski,
P. Białas,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
M. Molenda,
P. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
A. Słomski,
J. Smyrski,
A. Strzelecki
, et al. (3 additional authors not shown)
Abstract:
Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is ba…
▽ More
Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is based on the ROOT package used in many particle physics experiments.
△ Less
Submitted 7 March, 2014; v1 submitted 24 November, 2013;
originally announced November 2013.
-
A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays
Authors:
M. Silarski,
E. Czerwiński,
T. Bednarski,
P. Moskal,
P. Białas,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
A. Słomski,
J. Smyrski,
A. Strzelecki,
W. Wiślicki,
M. Zieliński
, et al. (1 additional authors not shown)
Abstract:
All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present metho…
▽ More
All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present methods and it is well suited for newly developed TOF-PET scanners with a large longitudinal field of view. The method enables also monitoring of the quality of the scintillator materials and in general allows for the continuous quality assurance of the PET detector performance.
△ Less
Submitted 7 March, 2014; v1 submitted 24 November, 2013;
originally announced November 2013.
-
Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators
Authors:
J. Smyrski,
P. Moskal,
T. Bednarski,
P. Białas,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki,
W. Wiślicki,
M. Zieliński
, et al. (1 additional authors not shown)
Abstract:
A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presen…
▽ More
A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presently used Positron Emission Tomography scanners.
△ Less
Submitted 24 November, 2013;
originally announced November 2013.
-
A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography
Authors:
M. Pałka,
T. Bednarski,
P. Białas,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
P. Moskal,
Sz. Niedźwiecki,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki,
W. Wiślicki,
M. Zieliński
, et al. (1 additional authors not shown)
Abstract:
This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes…
▽ More
This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes more compact final design. Furthermore, it allows to measure time when analog signals cross a reference voltage at different threshold levels with a very high precision of $\sim$ 10ps (rms) and thus enables sampling of signals in a voltage domain.
△ Less
Submitted 24 November, 2013;
originally announced November 2013.
-
System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector
Authors:
P. Białas,
J. Kowal,
A. Strzelecki,
T. Bednarski,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
M. Molenda,
P. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
L. Raczyński,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
W. Wiślicki,
M. Zieliński
Abstract:
Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to each tube of response (TOR). This is especially important in list-mode reconstruction systems, where an efficient analytical approximation of such function is required. In this contribution, we present a derivation of the s…
▽ More
Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to each tube of response (TOR). This is especially important in list-mode reconstruction systems, where an efficient analytical approximation of such function is required. In this contribution, we present a derivation of the system response kernel for a novel 2D strip PET.
△ Less
Submitted 6 October, 2013;
originally announced October 2013.
-
Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators
Authors:
L. Raczyński,
P. Kowalski,
T. Bednarski,
P. Białas,
E. Czerwiński,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
J. Kowal,
T. Kozik,
W. Krzemień,
M. Molenda,
P. Moskal,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik,
Z. Rudy,
P. Salabura,
N. G. Sharma,
M. Silarski,
A. Słomski,
J. Smyrski,
A. Strzelecki,
W. Wiślicki,
M. Zieliński
Abstract:
Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random measurements. This theory was applied to reconstruct signals from measurements of plastic scintillators. Sparse representation of obtained signals was found using SVD transform.
Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random measurements. This theory was applied to reconstruct signals from measurements of plastic scintillators. Sparse representation of obtained signals was found using SVD transform.
△ Less
Submitted 6 October, 2013;
originally announced October 2013.
-
STRIP-PET: a novel detector concept for the TOF-PET scanner
Authors:
P. Moskal,
T. Bednarski,
P. Białas,
M. Ciszewska,
E. Czerwiński,
A. Heczko,
M. Kajetanowicz,
Ł. Kapłon,
A. Kochanowski,
G. Konopka-Cupiał,
G. Korcyl,
W. Krzemień,
K. Łojek,
J. Majewski,
W. Migdał,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
Z. Rudy,
P. Salabura,
M. Silarski,
A. Słomski,
J. Smyrski,
J. Zdebik,
M. Zieliński
Abstract:
We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer scintillators. The position and time of the reaction of the gamma quanta in the detector material will be determined based on the time of arrival of light signals to t…
▽ More
We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer scintillators. The position and time of the reaction of the gamma quanta in the detector material will be determined based on the time of arrival of light signals to the edges of the scintillator strips.
△ Less
Submitted 23 May, 2013;
originally announced May 2013.
-
TOF-PET detector concept based on organic scintillators
Authors:
P. Moskal,
T. Bednarski,
P. Białas,
M. Ciszewska,
E. Czerwiński,
A. Heczko,
M. Kajetanowicz,
Ł. Kapłon,
A. Kochanowski,
G. Konopka-Cupiał,
G. Korcyl,
W. Krzemień,
K. Łojek,
J. Majewski,
W. Migdał,
M. Molenda,
Sz. Niedźwiecki,
M. Pałka,
Z. Rudy,
P. Salabura,
M. Silarski,
A. Słomski,
J. Smyrski,
J. Zdebik,
M. Zieliński
Abstract:
In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their…
▽ More
In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their amplitudes.
△ Less
Submitted 23 May, 2013;
originally announced May 2013.