Skip to main content

Showing 1–18 of 18 results for author: Molenda, M

Searching in archive physics. Search in all archives.
.
  1. arXiv:1504.06889  [pdf

    physics.med-ph physics.ins-det

    3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm

    Authors: Artur Słomski, Zbigniew Rudy, Tomasz Bednarski, Piotr Białas, Eryk Czerwiński, Łukasz Kapłon, Andrzej Kochanowski, Grzegorz Korcyl, Jakub Kowal, Paweł Kowalski, Tomasz Kozik, Wojciech Krzemień, Marcin Molenda, Paweł Moskal, Szymon Niedźwiecki, Marek Pałka, Monika Pawlik, Lech Raczyński, Piotr Salabura, Neha Gupta-Sharma, Michał Silarski, Jerzy Smyrski, Adam Strzelecki, Wojciech Wiślicki, Marcin Zieliński , et al. (1 additional authors not shown)

    Abstract: Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines connecting two detectors. As there is a multitude of detectors build-in typical PET tomograph structure, there are many possible detector pairs that pertain to th… ▽ More

    Submitted 26 April, 2015; originally announced April 2015.

    Comments: 10 pages, 7 figures

    Journal ref: Bio-Algorithms and Med-Systems 10(1), 1-7 (2014)

  2. arXiv:1504.06886  [pdf

    physics.ins-det cond-mat.mtrl-sci physics.med-ph

    Plastic scintillators for positron emission tomography obtained by the bulk polymerization method

    Authors: Łukasz Kapłon, Andrzej Kochanowski, Marcin Molenda, Paweł Moskal, Anna Wieczorek, Tomasz Bednarski, Piotr Białas, Eryk Czerwiński, Grzegorz Korcyl, Jakub Kowal, Paweł Kowalski, Tomasz Kozik, Wojciech Krzemień, Szymon Niedźwiecki, Marek Pałka, Monika Pawlik, Lech Raczyński, Zbigniew Rudy, Piotr Salabura, Neha Gupta-Sharma, Michał Silarski, Artur Słomski, Jerzy Smyrski, Adam Strzelecki, Wojciech Wiślicki , et al. (2 additional authors not shown)

    Abstract: This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillator, revealing properties which fulfill the requirements of novel positron emission tomography scanners based on plastic scintillators. The key parameters of the manufacturing process are determined and discussed.

    Submitted 26 April, 2015; originally announced April 2015.

    Comments: 7 pages, 4 figures

    Journal ref: Bio-Algorithms and Med-Systems 10(1), 27-31 (2014)

  3. arXiv:1502.02901  [pdf, other

    physics.ins-det nucl-ex

    A pilot study of the novel J-PET plastic scintillator with 2-(4-styrylphenyl)benzoxazole as a wavelength shifter

    Authors: A. Wieczorek, P. Moskal, Sz. Niedźwiecki, T. Bednarski, P. Białas, E. Czerwiński, A. Danel, A. Gajos, A. Gruntowski, D. Kamińska, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Molenda, M. Pałka, L. Raczyński, Z. Rudy, O. Rundel, P. Salabura, N. G. Sharma , et al. (8 additional authors not shown)

    Abstract: For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% $\pm$ 2% of the an… ▽ More

    Submitted 4 July, 2015; v1 submitted 10 February, 2015; originally announced February 2015.

    Journal ref: Acta Phys. Pol A127 (2015) 1487-1490

  4. arXiv:1407.8293  [pdf, other

    physics.ins-det hep-ex

    Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    Authors: L. Raczynski, P. Moskal, P. Kowalski, W. Wislicki, T. Bednarski, P. Bialas, E. Czerwinski, L . Kaplon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemien, E. Kubicz, M. Molenda, I. Moskal, Sz. Niedzwiecki, M. Palka, M. Pawlik-Niedzwiecka, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Slomski, J. Smyrski , et al. (4 additional authors not shown)

    Abstract: Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals… ▽ More

    Submitted 31 July, 2014; originally announced July 2014.

  5. arXiv:1407.7395  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex physics.med-ph

    Test of a single module of the J-PET scanner based on plastic scintillators

    Authors: P. Moskal, Sz. Niedźwiecki, T. Bednarski, E. Czerwiński, Ł. Kapłon, E. Kubicz, I. Moskal, M. Pawlik-Niedźwiecka, N. G. Sharma, M. Silarski, M. Zieliński, N. Zoń, P. Białas, A. Gajos, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, M. Pałka, L. Raczyński, Z. Rudy, P. Salabura , et al. (5 additional authors not shown)

    Abstract: Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module bu… ▽ More

    Submitted 29 August, 2014; v1 submitted 28 July, 2014; originally announced July 2014.

    Comments: 12 pages, 6 figures; Updated with editorial corrections related to publication in NIM A

    Journal ref: Nuclear Inst. and Methods in Physics Research A 764 (2014), pp. 317-321

  6. arXiv:1402.6840  [pdf

    physics.ins-det

    Determination of the map of efficiency of the J-PET detector with the GATE package

    Authors: P. Kowalski, L. Raczyński, T. Bednarski, P. Białas, E. Czerwiński, K. Giergiel, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemień, M. Molenda, I. Moskal, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik-Niedźwiecka, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki , et al. (5 additional authors not shown)

    Abstract: A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.

    Submitted 27 February, 2014; originally announced February 2014.

    Comments: 14 pages, 9 figures, proceeding from conference Symposium on Positron Emission Tomography: http://koza.if.uj.edu.pl/pet-symposium-2013/

    Journal ref: Bio-Algorithms and Med-Systems 10(2), 85-90 (2014)

  7. arXiv:1402.4116  [pdf

    physics.ins-det

    Database and data structure for the novel TOF-PET detector developed for J-PET project

    Authors: E. Czerwiński, M. Zieliński, T. Bednarski, P. Białas, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, E. Kubicz, M. Molenda, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki , et al. (3 additional authors not shown)

    Abstract: The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: regis… ▽ More

    Submitted 17 February, 2014; originally announced February 2014.

    Comments: 6 p, 3 figs, based on talk given at Symposium on Positron Emission Tomography, Sept. 19-22, 2013, Jagiellonian University, Kraków PL, submitted to Bio-Algorithms and Med-Systems

    Journal ref: Bio-Algorithms and Med-Systems 10(2), 79-83 (2014)

  8. arXiv:1401.6929  [pdf

    physics.comp-ph cs.CV cs.DC physics.ins-det physics.med-ph

    Computing support for advanced medical data analysis and imaging

    Authors: W. Wiślicki, T. Bednarski, P. Białas, E. Czerwiński, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, P. Moskal, S. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki, A. Wieczorek , et al. (2 additional authors not shown)

    Abstract: We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service architecture based on the grid and cloud concepts for distributed processing is proposed and critically discussed.

    Submitted 27 January, 2014; originally announced January 2014.

    Comments: 9 p, 3 figs, based on talk given at Symposium on Positron Emission Tomography, Sept. 19-22, 2013, Jagiellonian University, Kraków, Pl

    Journal ref: Bio-Algorithms and Med-Systems 10(2014)52

  9. arXiv:1312.2744  [pdf

    physics.ins-det nucl-ex physics.med-ph

    Calibration of photomultipliers gain used in the J-PET detector

    Authors: T. Bednarski, E. Czerwiński, P. Moskal, P. Białas, K. Giergiel, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, I. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki , et al. (5 additional authors not shown)

    Abstract: Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we de… ▽ More

    Submitted 16 December, 2013; v1 submitted 10 December, 2013; originally announced December 2013.

    Comments: Submitted to Bio-Algorithms and Med-Systems (12 pages, 6 figures)

    Journal ref: Bio-Algorithms and Med-Systems Volume 10(1), 13-17 (2014)

  10. arXiv:1312.0250  [pdf, other

    physics.ins-det nucl-ex physics.med-ph

    Simulations of gamma quanta scattering in a single module of the J-PET detector

    Authors: K. Szymański, P. Moskal, T. Bednarski, P. Białas, E. Czerwiński, K. Giergiel, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, I. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski , et al. (5 additional authors not shown)

    Abstract: This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the… ▽ More

    Submitted 1 December, 2013; originally announced December 2013.

    Comments: Submitted to Bio-Algorithms and Med-Systems (14 pages, 9 figures)

    Journal ref: Bio-Algorithms and Med-Systems 10(2), 71-77 (2014)

  11. arXiv:1311.6153  [pdf

    physics.ins-det physics.data-an physics.med-ph

    J-PET analysis framework for the prototype TOF-PET detector

    Authors: W. Krzemień, M. Silarski, K. Stola, D. Trybek, T. Bednarski, P. Białas, E. Czerwiński, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, M. Molenda, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, A. Słomski, J. Smyrski, A. Strzelecki , et al. (3 additional authors not shown)

    Abstract: Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is ba… ▽ More

    Submitted 7 March, 2014; v1 submitted 24 November, 2013; originally announced November 2013.

    Comments: 4 pages, 2 figures

    Journal ref: Bio-Algorithms and Med-Systems 10(1), 33-36 (2014)

  12. arXiv:1311.6152  [pdf

    physics.ins-det nucl-ex physics.med-ph

    A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

    Authors: M. Silarski, E. Czerwiński, T. Bednarski, P. Moskal, P. Białas, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, A. Słomski, J. Smyrski, A. Strzelecki, W. Wiślicki, M. Zieliński , et al. (1 additional authors not shown)

    Abstract: All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present metho… ▽ More

    Submitted 7 March, 2014; v1 submitted 24 November, 2013; originally announced November 2013.

    Comments: 10 pages, 7 figures

    Journal ref: Bio-Algorithms and Med-Systems 10(1), 19-25 (2014)

  13. arXiv:1311.6129  [pdf

    physics.ins-det hep-ex physics.med-ph

    Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators

    Authors: J. Smyrski, P. Moskal, T. Bednarski, P. Białas, E. Czerwiński, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, A. Strzelecki, W. Wiślicki, M. Zieliński , et al. (1 additional authors not shown)

    Abstract: A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presen… ▽ More

    Submitted 24 November, 2013; originally announced November 2013.

    Comments: Submitted to Bio-Algorithms and Med-Systems (6 pages, 4 figures)

    Journal ref: Bio-Algorithms and Med-Systems 10(2), 59-63 (2014)

  14. arXiv:1311.6127  [pdf

    physics.ins-det hep-ex physics.med-ph

    A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography

    Authors: M. Pałka, T. Bednarski, P. Białas, E. Czerwiński, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, P. Moskal, Sz. Niedźwiecki, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki, W. Wiślicki, M. Zieliński , et al. (1 additional authors not shown)

    Abstract: This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes… ▽ More

    Submitted 24 November, 2013; originally announced November 2013.

    Comments: Submitted to Bio-Algorithms and Med.-Systems (6 pages, 6 figures)

    Journal ref: Bio-Algorithms and Med.-Systems 10(1), 41-45 (2014)

  15. arXiv:1310.1614  [pdf, ps, other

    physics.med-ph nucl-th physics.ins-det

    System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector

    Authors: P. Białas, J. Kowal, A. Strzelecki, T. Bednarski, E. Czerwiński, Ł. Kapłon, A. Kochanowski, G. Korcyl, P. Kowalski, T. Kozik, W. Krzemień, M. Molenda, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, L. Raczyński, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, W. Wiślicki, M. Zieliński

    Abstract: Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to each tube of response (TOR). This is especially important in list-mode reconstruction systems, where an efficient analytical approximation of such function is required. In this contribution, we present a derivation of the s… ▽ More

    Submitted 6 October, 2013; originally announced October 2013.

    Comments: 10 pages, 2 figures; Presented at Symposium on applied nuclear physics and innovative technologies, Cracow, 03-06 June 2013

    Journal ref: Acta Phys. Polon. B Proceed. Suppl. 6, 1027-1036 (2013)

  16. arXiv:1310.1612  [pdf, other

    physics.med-ph physics.ins-det

    Application of Compressive Sensing Theory for the Reconstruction of Signals in Plastic Scintillators

    Authors: L. Raczyński, P. Kowalski, T. Bednarski, P. Białas, E. Czerwiński, Ł. Kapłon, A. Kochanowski, G. Korcyl, J. Kowal, T. Kozik, W. Krzemień, M. Molenda, P. Moskal, Sz. Niedźwiecki, M. Pałka, M. Pawlik, Z. Rudy, P. Salabura, N. G. Sharma, M. Silarski, A. Słomski, J. Smyrski, A. Strzelecki, W. Wiślicki, M. Zieliński

    Abstract: Compressive Sensing theory says that it is possible to reconstruct a measured signal if an enough sparse representation of this signal exists in comparison to the number of random measurements. This theory was applied to reconstruct signals from measurements of plastic scintillators. Sparse representation of obtained signals was found using SVD transform.

    Submitted 6 October, 2013; originally announced October 2013.

    Comments: 7 pages, 3 figures; Presented at Symposium on applied nuclear physics and innovative technologies, Cracow, 03-06 June 2013

    Journal ref: Acta Phys. Polon. B Proceed. Suppl. 6, 1121-1127 (2013)

  17. arXiv:1305.5562  [pdf

    physics.ins-det hep-ex nucl-ex physics.med-ph

    STRIP-PET: a novel detector concept for the TOF-PET scanner

    Authors: P. Moskal, T. Bednarski, P. Białas, M. Ciszewska, E. Czerwiński, A. Heczko, M. Kajetanowicz, Ł. Kapłon, A. Kochanowski, G. Konopka-Cupiał, G. Korcyl, W. Krzemień, K. Łojek, J. Majewski, W. Migdał, M. Molenda, Sz. Niedźwiecki, M. Pałka, Z. Rudy, P. Salabura, M. Silarski, A. Słomski, J. Smyrski, J. Zdebik, M. Zieliński

    Abstract: We briefly present a design of a new PET scanner based on strips of polymer scintillators arranged in a barrel constituting a large acceptance detector. The solution proposed is based on the superior timing properties of the polymer scintillators. The position and time of the reaction of the gamma quanta in the detector material will be determined based on the time of arrival of light signals to t… ▽ More

    Submitted 23 May, 2013; originally announced May 2013.

    Comments: Proceedings of the Positron Emission Tomography in Research and Diagnostics conference, Warsaw 16 - 19 May, 2012

    Journal ref: Nuclear Medicine Review 2012, 15, Suppl. C: C68-C69

  18. arXiv:1305.5559  [pdf

    physics.ins-det hep-ex nucl-ex physics.med-ph

    TOF-PET detector concept based on organic scintillators

    Authors: P. Moskal, T. Bednarski, P. Białas, M. Ciszewska, E. Czerwiński, A. Heczko, M. Kajetanowicz, Ł. Kapłon, A. Kochanowski, G. Konopka-Cupiał, G. Korcyl, W. Krzemień, K. Łojek, J. Majewski, W. Migdał, M. Molenda, Sz. Niedźwiecki, M. Pałka, Z. Rudy, P. Salabura, M. Silarski, A. Słomski, J. Smyrski, J. Zdebik, M. Zieliński

    Abstract: In this contribution we present a new concept of the large acceptance detector systems based on organic scintillators which may allow for simultaneous diagnostic of large fraction of the human body. Novelty of the concept lies in employing large blocks of polymer scintillators instead of crystals as detectors of annihilation quanta, and in using predominantly the timing of signals instead of their… ▽ More

    Submitted 23 May, 2013; originally announced May 2013.

    Comments: Proceedings of the Positron Emission Tomography in Research and Diagnostics conference, Warsaw 16 - 19 May, 2012

    Journal ref: Nuclear Medicine Review 2012, 15, Suppl. C: C81-C84