-
Impact of the circuit layout on the charge collection in a monolithic pixel sensor
Authors:
Corentin Lemoine,
Rafael Ballabriga,
Eric Buschmann,
Michael Campbell,
Raimon Casanova Mohr,
Dominik Dannheim,
Jona Dilg,
Ana Dorda,
Finn King,
Ono Feyens,
Philipp Gadow,
Ingrid-Maria Gregor,
Karsten Hansen,
Yajun He,
Lennart Huth,
Iraklis Kremastiotis,
Stefano Maffessanti,
Larissa Mendes,
Younes Otarid,
Christian Reckleben,
Sébastien Rettie,
Manuel Alejandro del Rio Viera,
Sara Ruiz Daza,
Judith Schlaadt,
Adriana Simancas
, et al. (6 additional authors not shown)
Abstract:
CERN's strategic R&D programme on technologies for future experiments recently started investigating the TPSCo 65nm ISC CMOS imaging process for monolithic active pixels sensors for application in high energy physics. In collaboration with the ALICE experiment and other institutes, several prototypes demonstrated excellent performance, qualifying the technology. The Hybrid-to-Monolithic (H2M), a n…
▽ More
CERN's strategic R&D programme on technologies for future experiments recently started investigating the TPSCo 65nm ISC CMOS imaging process for monolithic active pixels sensors for application in high energy physics. In collaboration with the ALICE experiment and other institutes, several prototypes demonstrated excellent performance, qualifying the technology. The Hybrid-to-Monolithic (H2M), a new test-chip produced in the same process but with a larger pixel pitch than previous prototypes, exhibits an unexpected asymmetric efficiency pattern.
This contribution describes a simulation procedure combining TCAD, Monte Carlo and circuit simulations to model and understand this effect. It proved able to reproduce measurement results and attribute the asymmetric efficiency drop to a slow charge collection due to low amplitude potential wells created by the circuitry layout and impacting efficiency via ballistic deficit.
△ Less
Submitted 27 March, 2025;
originally announced March 2025.
-
The H2M Monolithic Active Pixel Sensor -- characterizing non-uniform in-pixel response in a 65 nm CMOS imaging technology
Authors:
Sara Ruiz Daza,
Rafael Ballabriga,
Eric Buschmann,
Michael Campbell,
Raimon Casanova Mohr,
Dominik Dannheim,
Jona Dilg,
Ana Dorda,
Finn King,
Ono Feyens,
Philipp Gadow,
Ingrid-Maria Gregor,
Karsten Hansen,
Yajun He,
Lennart Huth,
Iraklis Kremastiotis,
Corentin Lemoine,
Stefano Maffessanti,
Larissa Mendes,
Younes Otarid,
Christian Reckleben,
Sébastien Rettie,
Manuel Alejandro del Rio Viera,
Judith Schlaadt,
Adriana Simancas
, et al. (6 additional authors not shown)
Abstract:
The high energy physics community recently gained access to the TPSCo 65 nm ISC (Image Sensor CMOS), which enables a higher in-pixel logic density in monolithic active pixel sensors (MAPS) compared to processes with larger feature sizes. To explore this novel technology, the Hybrid-to-Monolithic (H2M) test chip has been designed and manufactured. The design followed a digital-on-top design workflo…
▽ More
The high energy physics community recently gained access to the TPSCo 65 nm ISC (Image Sensor CMOS), which enables a higher in-pixel logic density in monolithic active pixel sensors (MAPS) compared to processes with larger feature sizes. To explore this novel technology, the Hybrid-to-Monolithic (H2M) test chip has been designed and manufactured. The design followed a digital-on-top design workflow and ports a hybrid pixel-detector architecture, with digital pulse processing in each pixel, into a monolithic chip. The chip matrix consists of 64$\times$16 square pixels with a size of 35$\times$35 um2, and a total active area of approximately 1.25 um2. The chip has been successfully integrated into the Caribou DAQ system. It is fully functional, and the measured threshold dispersion and noise agree with the expectation from front-end simulations. However, a non-uniform in-pixel response related to the size and location of the n-wells in the analog circuitry has been observed in test beam measurements and will be discussed in this contribution. This asymmetry in the pixel response, enhanced by the 35 um pixel pitch - larger than in other prototypes - and certain features of the readout circuit, has not been observed in prototypes with smaller pixel pitches in this technology.
△ Less
Submitted 15 May, 2025; v1 submitted 10 February, 2025;
originally announced February 2025.
-
Overcoming water diffusion limitations in hydrogels via microtubular graphene networks for soft actuators
Authors:
Margarethe Hauck,
Lena M. Saure,
Berit Zeller-Plumhoff,
Sören Kaps,
Jörg Hammel,
Caprice Mohr,
Lena Rieck,
Ali Shaygan Nia,
Xinliang Feng,
Nicola M. Pugno,
Rainer Adelung,
Fabian Schütt
Abstract:
Hydrogel-based soft actuators can operate in sensitive environments, bridging the gap of rigid machines interacting with soft matter. However, while stimuli-responsive hydrogels can undergo extreme reversible volume changes of up to ~90%, water transport in hydrogel actuators is in general limited by their poroelastic behavior. For poly(N-isopropylacrylamide) (PNIPAM) the actuation performance is…
▽ More
Hydrogel-based soft actuators can operate in sensitive environments, bridging the gap of rigid machines interacting with soft matter. However, while stimuli-responsive hydrogels can undergo extreme reversible volume changes of up to ~90%, water transport in hydrogel actuators is in general limited by their poroelastic behavior. For poly(N-isopropylacrylamide) (PNIPAM) the actuation performance is even further compromised by the formation of a dense skin layer. Here we show, that incorporating a bioinspired microtube graphene network into a PNIPAM matrix with a total porosity of only 5.4 % dramatically enhances actuation dynamics by up to ~400 % and actuation stress by ~4000 % without sacrificing the mechanical stability, overcoming the water transport limitations. The graphene network provides both untethered light-controlled and electrically-powered actuation. We anticipate that the concept provides a versatile platform for enhancing the functionality of soft matter by combining responsive and two-dimensional materials, paving the way towards designing soft intelligent matter.
△ Less
Submitted 24 March, 2023;
originally announced March 2023.
-
Oxidized organic molecules in the tropical free troposphere over Amazonia
Authors:
Qiaozhi Zha,
Diego Aliaga,
Radovan Krejci,
Victoria Sinclair,
Cheng Wu,
Wiebke Scholz,
Liine Heikkinen,
Eva Partoll,
Yvette Gramlich,
Wei Huang,
Markus Leiminger,
Joonas Enroth,
Otso Peräkylä,
Runlong Cai,
Xuemeng Chen,
Alkuin Maximilian Koenig,
Fernando Velarde,
Isabel Moreno,
Tuukka Petäjä,
Paulo Artaxo,
Paolo Laj,
Armin Hansel,
Samara Carbone,
Markku Kulmala,
Marcos Andrade
, et al. (3 additional authors not shown)
Abstract:
New particle formation (NPF) in the tropical free troposphere (FT) is a globally important source of cloud condensation nuclei, affecting cloud properties and climate. Oxidized organic molecules (OOMs) produced from biogenic volatile organic compounds are believed to contribute to aerosol formation in the tropical FT, but without direct chemical observations. We performed in-situ molecular-level O…
▽ More
New particle formation (NPF) in the tropical free troposphere (FT) is a globally important source of cloud condensation nuclei, affecting cloud properties and climate. Oxidized organic molecules (OOMs) produced from biogenic volatile organic compounds are believed to contribute to aerosol formation in the tropical FT, but without direct chemical observations. We performed in-situ molecular-level OOMs measurements at the Bolivian station Chacaltaya at 5240 meters above sea level, on the western edge of Amazonia. For the first time, we demonstrate the presence of OOMs, mainly with 4-5 carbon atoms, simultaneously in both gas and particulate phases in tropical FT air from Amazonia. These observations, combined with air mass history analyses, indicate that the observed OOMs are linked to isoprene emitted from the rainforests hundreds of kilometers away. Based on particle-phase measurements, we find that these compounds can contribute to the growth of newly formed particles, and are potentially crucial for new particle formation in the tropical free troposphere on a continental scale. Our study will thus improve the understanding of aerosol formation process in the tropics.
△ Less
Submitted 22 February, 2023;
originally announced February 2023.
-
RD50-MPW3: A fully monolithic digital CMOS sensor for future tracking detectors
Authors:
Patrick Sieberer,
Chenfan Zhang,
Thomas Bergauer,
Raimon Casanova Mohr,
Christian Irmler,
Nissar Karim,
Jose Mazorra de Cos,
Bernhard Pilsl,
Eva Vilella
Abstract:
The CERN-RD50 CMOS working group develops the RD50-MPWseries of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structure…
▽ More
The CERN-RD50 CMOS working group develops the RD50-MPWseries of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structures implemented in the chip and the problems they aim to solve. The main analog and digital features of the sensor are already tested and initial laboratory characterisation of the chip is presented.
△ Less
Submitted 17 January, 2023; v1 submitted 21 November, 2022;
originally announced November 2022.
-
1 GHz dual-comb spectrometer for fast and broadband measurements
Authors:
Thibault Voumard,
John Darvill,
Thibault Wildi,
Markus Ludwig,
Christian Mohr,
Ingmar Hartl,
Tobias Herr
Abstract:
Dual-frequency comb spectroscopy permits broadband precision spectroscopic measurements with short acquisition time. A dramatic improvement of the maximal spectral bandwidth and the minimal measurement time can be expected when the lasers' pulse repetition rate is increased, owing to a quadratic dependence (Nyquist criterion). Here, we demonstrate a dual-comb system operating at a high repetition…
▽ More
Dual-frequency comb spectroscopy permits broadband precision spectroscopic measurements with short acquisition time. A dramatic improvement of the maximal spectral bandwidth and the minimal measurement time can be expected when the lasers' pulse repetition rate is increased, owing to a quadratic dependence (Nyquist criterion). Here, we demonstrate a dual-comb system operating at a high repetition rate of 1 GHz based on mature, digitally-controlled, low-noise mode-locked lasers. Compared to conventional lower repetition rate ($\sim$100 MHz) oscillators, this represents a 100-fold improvement in terms of the Nyquist criterion, while still providing adequate spectral sampling even for trace gas absorption fingerprints. Two spectroscopy experiments are performed with acquisition parameters not attainable in a 100 MHz system: detection of water vapor absorption around 1375 nm, demonstrating the potential for fast and ambiguity-free broadband operation, and real-time acquisition of narrow gas absorption features across a spectral span of 0.6 THz (600 comb lines) in only 5 $μ$s. Additionally, we show high mutual coherence of the lasers below the Hz-level, generating opportunities for broadband spectroscopy even with low-bandwidth detectors such as mid-infrared, imaging or photo-acoustic detectors.
△ Less
Submitted 16 November, 2021;
originally announced November 2021.
-
Ultrafast MHz-rate burst-mode pump-probe laser for the FLASH FEL facility based on nonlinear compression of ps-level pulses from an Yb-amplifier chain
Authors:
Marcus Seidel,
Federico Pressacco,
Oender Akcaalan,
Thomas Binhammer,
John Darvill,
Nagitha Ekanayake,
Maik Frede,
Uwe Grosse-Wortmann,
Michael Heber,
Christoph M. Heyl,
Dmytro Kutnyakhov,
Chen Li,
Christian Mohr,
Jost Müller,
Oliver Puncken,
Harald Redlin,
Nora Schirmel,
Sebastian Schulz,
Angad Swiderski,
Hamed Tavakol,
Henrik Tünnermann,
Caterina Vidoli,
Lukas Wenthaus,
Nils Wind,
Lutz Winkelmann
, et al. (2 additional authors not shown)
Abstract:
The Free-Electron Laser (FEL) FLASH offers the worldwide still unique capability to study ultrafast processes with high-flux, high-repetition rate XUV and soft X-ray pulses. The vast majority of experiments at FLASH are of pump-probe type. Many of them rely on optical ultrafast lasers. Here, a novel FEL facility laser is reported which combines high average power output from Yb:YAG amplifiers with…
▽ More
The Free-Electron Laser (FEL) FLASH offers the worldwide still unique capability to study ultrafast processes with high-flux, high-repetition rate XUV and soft X-ray pulses. The vast majority of experiments at FLASH are of pump-probe type. Many of them rely on optical ultrafast lasers. Here, a novel FEL facility laser is reported which combines high average power output from Yb:YAG amplifiers with spectral broadening in a Herriott-type multi-pass cell and subsequent pulse compression to sub-100 fs durations. Compared to other facility lasers employing optical parametric amplification, the new system comes with significantly improved noise figures, compactness, simplicity and power efficiency. Like FLASH, the optical laser operates with 10 Hz burst repetition rate. The bursts consist of 800 $μ$s long trains of up to 800 ultrashort pulses being synchronized to the FEL with femtosecond precision. In the experimental chamber, pulses with up to 50 $μ$J energy, 60 fs FWHM duration and 1 MHz rate at 1.03 $μ$m wavelength are available and can be adjusted by computer-control. Moreover, nonlinear polarization rotation is implemented to improve laser pulse contrast. First cross-correlation measurements with the FEL at the plane-grating monochromator photon beamline are demonstrated, exhibiting the suitability of the laser for user experiments at FLASH.
△ Less
Submitted 14 May, 2021; v1 submitted 12 May, 2021;
originally announced May 2021.
-
Extrapolating continuous color emotions through deep learning
Authors:
Vishaal Ram,
Laura P. Schaposnik,
Nikos Konstantinou,
Eliz Volkan,
Marietta Papadatou-Pastou,
Banu Manav,
Domicele Jonauskaite,
Christine Mohr
Abstract:
By means of an experimental dataset, we use deep learning to implement an RGB extrapolation of emotions associated to color, and do a mathematical study of the results obtained through this neural network. In particular, we see that males typically associate a given emotion with darker colors while females with brighter colors. A similar trend was observed with older people and associations to lig…
▽ More
By means of an experimental dataset, we use deep learning to implement an RGB extrapolation of emotions associated to color, and do a mathematical study of the results obtained through this neural network. In particular, we see that males typically associate a given emotion with darker colors while females with brighter colors. A similar trend was observed with older people and associations to lighter colors. Moreover, through our classification matrix, we identify which colors have weak associations to emotions and which colors are typically confused with other colors.
△ Less
Submitted 4 August, 2020;
originally announced September 2020.
-
Electron and proton irradiation effect on the minority carrier lifetime in SiC passivated p-doped Ge wafers for space photovoltaics
Authors:
C. Weiss,
S. Park,
J. Lefèvre,
B. Boizot,
C. Mohr,
O. Cavani,
S. Picard,
R. Kurstjens,
T. Niewelt,
S. Janz
Abstract:
We report on the effect of electron and proton irradiation on effective minority carrier lifetimes ($τ_{eff}$) in p-type Ge wafers. Minority carrier lifetimes are assessed using the microwave-detected photoconductance decay ($μ$W-PCD) method. We examine the dependence of $τ_{eff}$ on the p-type doping level and on electron and proton radiation fluences at 1 MeV. The measured $τ_{eff}$ before and a…
▽ More
We report on the effect of electron and proton irradiation on effective minority carrier lifetimes ($τ_{eff}$) in p-type Ge wafers. Minority carrier lifetimes are assessed using the microwave-detected photoconductance decay ($μ$W-PCD) method. We examine the dependence of $τ_{eff}$ on the p-type doping level and on electron and proton radiation fluences at 1 MeV. The measured $τ_{eff}$ before and after irradiation are used to estimate the minority carriers diffusion lengths, which is an important parameter for solar cell operation. We observe $τ_{eff}$ ranging from 50 to 230 $μ$s for Ge doping levels between 1E17 and 1E16 at.cm$^{-3}$, corresponding to diffusion lengths of 500-1400 $μ$m. A separation of $τ_{eff}$ in Ge bulk lifetime and surface recombination velocity is conducted by irradiating Ge lifetime samples of different thicknesses. The possible radiation-induced defects are discussed on the basis of literature.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
Performance of CMOS pixel sensor prototypes in ams H35 and aH18 technology for the ATLAS ITk upgrade
Authors:
Moritz Kiehn,
Francesco Armando Di Bello,
Mathieu Benoit,
Raimon Casanova Mohr,
Hucheng Chen,
Kai Chen,
Sultan D. M. S.,
Felix Ehrler,
Didier Ferrere,
Dylan Frizell,
Sergio Gonzalez Sevilla,
Giuseppe Iacobucci,
Francesco Lanni,
Hongbin Liu,
Claudia Merlassino,
Jessica Metcalfe,
Antonio Miucci,
Ivan Peric,
Mridula Prathapan,
Rudolf Schimassek,
Mateus Vicente Barreto,
Thomas Weston,
Eva Vilella Figueras,
Alena Weber,
Michele Weber
, et al. (5 additional authors not shown)
Abstract:
Pixel sensors based on commercial high-voltage CMOS processes are an exciting technology that is considered as an option for the outer layer of the ATLAS inner tracker upgrade at the High Luminosity LHC. Here, charged particles are detected using deep n-wells as sensor diodes with the depleted region extending into the silicon bulk. Both analog and digital readout electronics can be added to achie…
▽ More
Pixel sensors based on commercial high-voltage CMOS processes are an exciting technology that is considered as an option for the outer layer of the ATLAS inner tracker upgrade at the High Luminosity LHC. Here, charged particles are detected using deep n-wells as sensor diodes with the depleted region extending into the silicon bulk. Both analog and digital readout electronics can be added to achieve different levels of integration up to a fully monolithic sensor. Small scale prototypes using the ams CMOS technology have previously demonstrated that it can achieve the required radiation tolerance of $10^{15}~\text{n}_\text{eq}/\text{cm}^2$ and detection efficiencies above $99.5~\%$. Recently, large area prototypes, comparable in size to a full sensor, have been produced that include most features required towards a final design: the H35demo prototype produced in ams H35 technology that supports both external and integrated readout and the monolithic ATLASPix1 pre-production design produced in ams aH18 technology. Both chips are based on large fill-factor pixel designs, but differ in readout structure. Performance results for H35DEMO with capacitively-coupled external readout and first results for the monolithic ATLASPix1 are shown.
△ Less
Submitted 8 June, 2020; v1 submitted 16 July, 2018;
originally announced July 2018.
-
Optical frequency comb spectroscopy at 3-5.4 μm with a doubly resonant optical parametric oscillator
Authors:
Amir Khodabakhsh,
Venkata Ramaiah-Badarla,
Lucile Rutkowski,
Alexandra C. Johansson,
Kevin F. Lee,
Jie Jiang,
Christian Mohr,
Martin E. Fermann,
Aleksandra Foltynowicz
Abstract:
We present a versatile mid-infrared frequency comb spectroscopy system based on a doubly resonant optical parametric oscillator tunable in the 3-5.4 μm range and two detection methods, a Fourier transform spectrometer (FTS) and a Vernier spectrometer. Using the FTS with a multipass cell we measure high-precision broadband absorption spectra of CH$_4$ and NO at ~3.3 μm and ~5.2 μm, respectively, an…
▽ More
We present a versatile mid-infrared frequency comb spectroscopy system based on a doubly resonant optical parametric oscillator tunable in the 3-5.4 μm range and two detection methods, a Fourier transform spectrometer (FTS) and a Vernier spectrometer. Using the FTS with a multipass cell we measure high-precision broadband absorption spectra of CH$_4$ and NO at ~3.3 μm and ~5.2 μm, respectively, and of atmospheric species (CH$_4$, CO, CO$_2$ and H$_2$O) in air in the signal and idler wavelength range. The figure of merit of the system is on the order of 10$^{-8}$ cm$^{-1}$ Hz$^{-1/2}$ per spectral element, and multiline fitting yields minimum detectable concentrations of 10-20 ppb Hz$^{-1/2}$ for CH$_4$, NO and CO. For the first time in the mid-infrared, we perform continuous-filtering Vernier spectroscopy using a low finesse enhancement cavity, a grating and a single detector, and measure the absorption spectrum of CH$_4$ and H$_2$O in ambient air at ~3.3 μm.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs
Authors:
Piotr Maslowski,
Kevin F. Lee,
Alexandra C. Johansson,
Amir Khodabakhsh,
Grzegorz Kowzan,
Lucile Rutkowski,
Andrew A. Mills,
Christian Mohr,
Jie Jiang,
Martin E. Fermann,
Aleksandra Foltynowicz
Abstract:
Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum de…
▽ More
Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum delay range (Δ$_{max}$) of the interferometer, so acquisition of high-resolution spectra implies long measurement times and large instrument size. We overcome this limit by combining the Fourier transform spectrometer with an optical frequency comb and measuring the intensities of individual comb lines by precisely matching the Δ$_{max}$ to the comb line spacing. This allows measurements of absorption lines narrower than the nominal (optical path-limited) resolution without ringing effects from the instrumental lineshape and reduces the acquisition time and interferometer length by orders of magnitude.
△ Less
Submitted 28 May, 2015;
originally announced May 2015.