-
A low-power integrated magneto-optic modulator on silicon for cryogenic applications
Authors:
Paolo Pintus,
Leonardo Ranzani,
Sergio Pinna,
Duanni Huang,
Martin V. Gustafsson,
Fotini Karinou,
Giovanni Andrea Casula,
Yuya Shoji,
Yota Takamura,
Tetsuya Mizumoto,
Mohammad Soltani,
John E. Bowers
Abstract:
A fundamental challenge of the quantum revolution is to efficiently interface the quantum computing systems operating at cryogenic temperatures with room temperature electronics and media for high data-rate communication. Current approaches to control and readout of such cryogenic computing systems use electrical cables, which prevent scalability due to their large size, heat conduction, and limit…
▽ More
A fundamental challenge of the quantum revolution is to efficiently interface the quantum computing systems operating at cryogenic temperatures with room temperature electronics and media for high data-rate communication. Current approaches to control and readout of such cryogenic computing systems use electrical cables, which prevent scalability due to their large size, heat conduction, and limited bandwidth1. A more viable approach is to use optical fibers which allow high-capacity transmission and thermal isolation. A key component in implementing photonic datalinks is a cryogenic optical modulator for converting data from the electrical to the optical domain at high speed and with low power consumption, while operating at temperatures of 4 K or lower. Cryogenic modulators based on the electro-optic effect have been demonstrated in a variety of material platforms, however they are voltage driven components while superconducting circuits are current based, resulting in a large impedance mismatch. Here, we present the first demonstration of an integrated current-driven modulator based on the magneto-optic effect operating over a wide temperature range that extends down to less than 4 K. The modulator works at data rates up to 2 Gbps with energy consumption below 4 pJ/bit, and we show that this figure can be reduced to less than 40 fJ/bit with optimized design and fabrication. This modulator is a hybrid device, where a current-driven magneto-optically active crystal (cerium substituted yttrium iron garnet, or Ce:YIG) is bonded to a high-quality silicon microring resonator. Because of its potential for extremely low power consumption under cryogenic conditions, the class of magneto-optical modulators demonstrated here has the potential to enable efficient data links in large-scale systems for quantum information processing.
△ Less
Submitted 9 September, 2021;
originally announced September 2021.
-
Performance test of the MAIKo active target
Authors:
T. Furuno,
T. Kawabata,
H. J. Ong,
S. Adachi,
Y. Ayyad,
T. Baba,
Y. Fujikawa,
T. Hashimoto,
K. Inaba,
Y. Ishii,
S. Kabuki,
H. Kubo,
Y. Matsuda,
Y. Matsuoka,
T. Mizumoto,
T. Morimoto,
M. Murata,
T. Sawano,
T. Suzuki,
A. Takada,
J. Tanaka,
I. Tanihata,
T. Tanimori,
D. T. Tran,
M. Tsumura
, et al. (1 additional authors not shown)
Abstract:
A new active target named MAIKo (Mu-PIC based Active target for Inverse Kinematics$_{\circ}$) has been developed at Kyoto University and Research Center for Nuclear Physics (RCNP), Osaka University. MAIKo is suited for missing-mass spectroscopy of unstable nuclei at forward scattering angles in inverse kinematics. MAIKo consists of a time projection chamber (TPC), which incorporates a micro-pixel…
▽ More
A new active target named MAIKo (Mu-PIC based Active target for Inverse Kinematics$_{\circ}$) has been developed at Kyoto University and Research Center for Nuclear Physics (RCNP), Osaka University. MAIKo is suited for missing-mass spectroscopy of unstable nuclei at forward scattering angles in inverse kinematics. MAIKo consists of a time projection chamber (TPC), which incorporates a micro-pixel chamber ($μ$-PIC) as the electron multiplication and collection system. In MAIKo, the medium gas also plays the role of a reaction target, thus allowing detection of low-energy recoil particles with high position resolution. The MAIKo TPC was commissioned with He(93%)+iso-C$_{4}$H$_{10}$(7%) and He(93%)+CO$_{2}$(7%) mixture gasses at 430 hPa. The gas gain and the angular resolution of MAIKo were evaluated with an alpha source and a $^{4}$He beam at 56 MeV. The TPC was stably operated up to 1000-kcps beam intensity. A tracking algorithm using the Hough transform method has been developed to analyze scattering events. An angular resolution of 1.3$^{\circ}$ was achieved for scattered $^{4}$He particles.
△ Less
Submitted 6 September, 2018;
originally announced September 2018.
-
First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant
Authors:
Dai Tomono,
Tetsuya Mizumoto,
Atsushi Takada,
Shotaro Komura,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Makoto Oda,
Toru Tanimori
Abstract:
We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in…
▽ More
We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in the vicinity of the Fukushima Daiichi Nuclear Power Plants in Japan in 2014. The obtained distribution of brightness (or emissivity) with remote-sensing observations is unambiguously converted into the dose distribution. We confirm that the dose distribution is consistent with the one taken by conventional mapping measurements with a dosimeter physically placed at each grid point. Furthermore, its imaging spectroscopy, boosted by Compton-edge-free spectra, reveals complex radioactive features in a quantitative manner around each individual target point in the background-dominated environment. Notably, we successfully identify a "micro hot spot" of residual caesium contamination even in an already decontaminated area. These results show that the ETCC performs exactly as the geometrical optics predicts, demonstrates its versatility in the field radiation measurement, and reveals potentials for application in many fields, including the nuclear industry, medical field, and astronomy.
△ Less
Submitted 5 February, 2017;
originally announced February 2017.
-
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Authors:
Toru Tanimori,
Yoshitaka Mizumura,
Atsushi Takada,
Shohei Miyamoto,
Taito Takemura,
Tetsuro Kishimoto,
Shotaro Komura,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Yuma Nakamasu,
Kiseki Nakamura,
Joseph D. Parker,
Tatsuya Sawano,
Shinya Sonoda,
Dai Tomono,
Kei Yoshikawa
Abstract:
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, whic…
▽ More
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
△ Less
Submitted 5 February, 2017;
originally announced February 2017.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation
Authors:
Tetsuya Mizumoto,
Dai Tomono,
Atsushi Takada,
Toru Tanimori,
Shotaro Komura,
Hidetoshi Kubo,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Kiseki Nakamura,
Shogo Nakamura,
Makoto Oda,
Joseph D. Parker,
Tatsuya Sawano,
Naoto Bando,
Akira Nabetani
Abstract:
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the sc…
▽ More
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;μ\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$σ$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
△ Less
Submitted 6 August, 2015;
originally announced August 2015.
-
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Authors:
Yoshihiro Matsuoka,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
Y. Mizumura,
S. Iwaki,
T. Sawano,
S. Komura,
T. Kishimoto,
M. Oda,
T. Takemura,
S. Miyamoto,
S. Sonoda,
D. Tomono,
K. Miuchi,
S. Kabuki,
S. Kurosawa
Abstract:
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient back…
▽ More
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
△ Less
Submitted 22 January, 2015; v1 submitted 12 December, 2014;
originally announced December 2014.
-
Search for Hidden photons with Sumico
Authors:
Yoshizumi Inoue,
Tetsuya Mizumoto,
Ryosuke Ohta,
Tomoki Horie,
Jun'ya Suzuki,
Makoto Minowa
Abstract:
We searched for solar hidden photons in the visible photon energy range using a hidden photon detector add-on attached to Sumico. It consists of a parabolic mirror of dia. 0.5m and f=1m installed in a vacuum chamber, and a low noise photomultiplier tube at the focal point. No evidence for the existence of hidden photons was found in the latest measurement giving a new limit on the photon-hidden ph…
▽ More
We searched for solar hidden photons in the visible photon energy range using a hidden photon detector add-on attached to Sumico. It consists of a parabolic mirror of dia. 0.5m and f=1m installed in a vacuum chamber, and a low noise photomultiplier tube at the focal point. No evidence for the existence of hidden photons was found in the latest measurement giving a new limit on the photon-hidden photon mixing parameter in the hidden photon mass range 0.001-1eV.
△ Less
Submitted 27 December, 2013;
originally announced December 2013.
-
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Authors:
Y. Mizumura,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
S. Sonoda,
D. Tomono,
T. Sawano,
K. Nakamura,
Y. Matsuoka,
S. Komura,
S. Nakamura,
M. Oda,
K. Miuchi,
S. Kabuki,
Y. Kishimoto,
S. Kurosawa,
S. Iwaki
Abstract:
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of…
▽ More
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
△ Less
Submitted 7 February, 2014; v1 submitted 2 December, 2013;
originally announced December 2013.
-
Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber
Authors:
Joseph D Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno,
Masahiro Ikeno,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Spatial resolution of a μPIC-based neutron imaging detector
Authors:
Joseph D. Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno
Abstract:
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data…
▽ More
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.
△ Less
Submitted 16 May, 2013;
originally announced May 2013.
-
Experimental search for solar hidden photons in the eV energy range using kinetic mixing with photons
Authors:
T. Mizumoto,
R. Ohta,
T. Horie,
J. Suzuki,
Y. Inoue,
M. Minowa
Abstract:
We have searched for solar hidden photons in the eV energy range using a dedicated hidden photon detector. The detector consisted of a parabolic mirror with a diameter of 500mm and a focal length of 1007mm installed in a vacuum chamber, and a photomultiplier tube at its focal point. The detector was attached to the Tokyo axion helioscope, Sumico which has a mechanism to track the sun. From the res…
▽ More
We have searched for solar hidden photons in the eV energy range using a dedicated hidden photon detector. The detector consisted of a parabolic mirror with a diameter of 500mm and a focal length of 1007mm installed in a vacuum chamber, and a photomultiplier tube at its focal point. The detector was attached to the Tokyo axion helioscope, Sumico which has a mechanism to track the sun. From the result of the measurement, we found no evidence for the existence of hidden photons and set a limit on the photon-hidden photon mixing parameter χdepending on the hidden photon mass m_{γ'}.
△ Less
Submitted 18 June, 2013; v1 submitted 5 February, 2013;
originally announced February 2013.
-
Tokyo axion helioscope experiment
Authors:
Y. Inoue,
Y. Akimoto,
R. Ohta,
T. Mizumoto,
A. Yamamoto,
M. Minowa
Abstract:
A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m x 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. In the past measurements, axion mass up to 0.27eV have been scanned. It has been upgraded to handle dispersion-matching gas (He-4) of hig…
▽ More
A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m x 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. In the past measurements, axion mass up to 0.27eV have been scanned. It has been upgraded to handle dispersion-matching gas (He-4) of higher density to explore higher mass region. From December 2007 through April 2008, the axion mass region 0.84 < m < 1.00eV was newly explored, where the axions in the "photon-coupling vs. mass" parameter region of the preferred axion models were newly searched. From the absence of any evidence, a limit on axion-photon coupling constant was set to be g < 5.6-13.4e-10/GeV at 95% confidence level in the above mass region.
△ Less
Submitted 2 February, 2010;
originally announced February 2010.