-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
A measurement of the scintillation decay time constant of nuclear recoils in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) an…
▽ More
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation detector whose purpose is the direct detection of dark matter via NR which can be induced by collisions between Weakly Interacting Massive Particles (WIMPs) and a xenon nucleus. The inner detector volume contains 832 kg of LXe.
$^{252}$Cf was used as an external neutron source for irradiating the detector. The scintillation decay time constant of the resulting neutron induced NR was evaluated by comparing the observed photon detection times with Monte Carlo simulations. Fits to the decay time prefer two decay time components, one for each of the Xe$_{2}^{*}$ singlet and triplet states, with $τ_{S}$ = 4.3$\pm$0.6 ns taken from prior research, $τ_{T}$ was measured to be 26.9$^{+0.7}_{-1.1}$ ns with a singlet state fraction F$_{S}$ of 0.252$^{+0.027}_{-0.019}$.We also evaluated the performance of pulse shape discrimination between NR and electron recoil (ER) with the aim of reducing the electromagnetic background in WIMP searches. For a 50\% NR acceptance, the ER acceptance was 13.7${\pm}$1.0\% and 4.1${\pm}$0.7\% in the energy ranges of 5--10 keV$_{\rm ee}$ and 10--15 keV$_{\rm ee}$, respectively.
△ Less
Submitted 24 December, 2018; v1 submitted 16 September, 2018;
originally announced September 2018.
-
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Authors:
M. Kobayashi,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu,
K. Miuchi
, et al. (11 additional authors not shown)
Abstract:
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in…
▽ More
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
△ Less
Submitted 22 December, 2018; v1 submitted 19 August, 2018;
originally announced August 2018.
-
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During dev…
▽ More
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
△ Less
Submitted 29 January, 2019; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixin…
▽ More
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
△ Less
Submitted 18 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
A direct dark matter search in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was…
▽ More
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
△ Less
Submitted 25 December, 2018; v1 submitted 6 April, 2018;
originally announced April 2018.
-
Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant sig…
▽ More
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $γ$-ray/$X$-ray or double electron capture signals from $β$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.
△ Less
Submitted 16 April, 2018; v1 submitted 10 January, 2018;
originally announced January 2018.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
Identification of $^{210}$Pb and $^{210}$Po in the bulk of copper samples with a low-background alpha particle counter
Authors:
XMASS collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. Th…
▽ More
We established a method to assay $^{210}$Pb and $^{210}$Po contaminations in the bulk of copper samples using a low-background alpha particle counter. The achieved sensitivity for the $^{210}$Pb and $^{210}$Po contaminations reaches a few mBq/kg. Due to this high sensitivity, the $^{210}$Pb and $^{210}$Po contaminations in oxygen free copper bulk were identified and measured for the first time. The $^{210}$Pb contaminations of our oxygen free copper samples were 17-40 mBq/kg. Based on our investigation of copper samples in each production step, the $^{210}$Pb in oxygen free copper was understood to be a small residual of an electrolysis process. This method to measure bulk contaminations of $^{210}$Pb and $^{210}$Po could be applied to other materials.
△ Less
Submitted 9 January, 2018; v1 submitted 20 July, 2017;
originally announced July 2017.
-
Observation of thundercloud-related gamma rays and neutrons in Tibet
Authors:
H. Tsuchiya,
K. Hibino,
K. Kawata,
N. Hotta,
N. Tateyama,
M. Ohnishi,
M. Takita,
D. Chen,
J. Huang,
M. Miyasaka,
I. Kondo,
E. Takahashi,
S. Shimoda,
Y. Yamada,
H. Lu,
J. L. Zhang,
X. X. Yu,
Y. H. Tan,
S. M. Nie,
K. Munakata,
T. Enoto,
K. Makishima
Abstract:
During the 2010 rainy season in Yangbajing (4300 m above sea level) in Tibet, China, a long-duration count enhancement associated with thunderclouds was detected by a solar neutron telescope and neutron monitors installed at the Yangbajing Comic Ray Observatory. The event, lasting for $\sim$40 min, was observed on July 22, 2010. The solar neutron telescope detected significant $γ$-ray signals with…
▽ More
During the 2010 rainy season in Yangbajing (4300 m above sea level) in Tibet, China, a long-duration count enhancement associated with thunderclouds was detected by a solar neutron telescope and neutron monitors installed at the Yangbajing Comic Ray Observatory. The event, lasting for $\sim$40 min, was observed on July 22, 2010. The solar neutron telescope detected significant $γ$-ray signals with energies $>$40 MeV in the event. Such a prolonged high-energy event has never been observed in association with thunderclouds, clearly suggesting that electron acceleration lasts for 40 min in thunderclouds. In addition, Monte Carlo simulations showed that $>$10-MeV $γ$ rays largely contribute to the neutron monitor signals, while $>$1-keV neutrons produced via a photonuclear reaction contribute relatively less to the signals. This result suggests that enhancements of neutron monitors during thunderstorms are not necessarily a clear evidence for neutron production, as previously thought.
△ Less
Submitted 11 April, 2012;
originally announced April 2012.