-
A new True Triaxial Apparatus with pore fluid system for rock deformation under representative crustal stress conditions
Authors:
Ashley Stanton-Yonge,
Thomas M. Mitchell,
Philip G. Meredith,
Neil Hughes,
Steve Boone,
John Browning,
David Healy,
John Bowles
Abstract:
We have developed a new True Triaxial Apparatus (TTA) for rock deformation consisting of six servo-controlled loading rams that transmit maximum stresses of 220 MPa in the two horizontal axes and 400 MPa in the vertical axis to 50 mm side cubic rock samples. The sample and loading platens are introduced in a steel vessel where rock specimens can be subjected to up to 60 MPa of confining pressure,…
▽ More
We have developed a new True Triaxial Apparatus (TTA) for rock deformation consisting of six servo-controlled loading rams that transmit maximum stresses of 220 MPa in the two horizontal axes and 400 MPa in the vertical axis to 50 mm side cubic rock samples. The sample and loading platens are introduced in a steel vessel where rock specimens can be subjected to up to 60 MPa of confining pressure, and pore fluids line connected to two pump intensifiers allow for highly accurate permeability measurements along the three loading axes. We present a suite of Finite Element Method (FEM) models implemented to determine the conditions and loading configuration that minimise the loading boundary effects during true triaxial loading. These observations are generic and we expect they will contribute to the development of true triaxial loading systems generally. Finally, we validate our experimental configuration by presenting results on permeability measurements along the three axes on cubic samples of three types of well studied rocks: Darley Dale sandstone, Crab Orchard sandstone, and Etna basalt.
△ Less
Submitted 20 March, 2025;
originally announced March 2025.
-
Optical Switching of $χ^{(2)}$ in Diamond Photonics
Authors:
Sigurd Flågan,
Joe Itoi,
Prasoon K. Shandilya,
Vinaya K. Kavatamane,
Matthew Mitchell,
David P. Lake,
Paul E. Barclay
Abstract:
Diamond's unique physical properties make it a versatile materials for a wide range of nonlinear and quantum photonic technologies. However, unlocking diamond's full potential as a nonlinear photonic material with non-zero second-order susceptibility $χ^{(2)}\neq0$ requires symmetry breaking. In this work, we use a nanoscale cavity to demonstrate second-harmonic generation (SHG) in diamond, and de…
▽ More
Diamond's unique physical properties make it a versatile materials for a wide range of nonlinear and quantum photonic technologies. However, unlocking diamond's full potential as a nonlinear photonic material with non-zero second-order susceptibility $χ^{(2)}\neq0$ requires symmetry breaking. In this work, we use a nanoscale cavity to demonstrate second-harmonic generation (SHG) in diamond, and demonstrate, for the first time, that the magnitude of the diamond's effective $χ^{(2)}$ strongly depends on the electronic configuration of defects in the diamond crystal, such as nitrogen vacancy centres. The modification of $χ^{(2)}$ arises from photoionisation from the negative to neutral charge state, and is manifested by quenching of SHG upon green illumination. Toggling the green illumination allows for optical switching of the device's $χ^{(2)}$. Optical control of $χ^{(2)}$ by defect engineering opens the door for second-order nonlinear processes in diamond.
△ Less
Submitted 9 May, 2025; v1 submitted 21 November, 2024;
originally announced December 2024.
-
State Selective Preparation and Nondestructive Detection of Trapped ${\rm O}_2^+$
Authors:
Ambesh Pratik Singh,
Michael Mitchell,
Will Henshon,
Addison Hartman,
Annika Lunstad,
Boran Kuzhan,
David Hanneke
Abstract:
The ability to prepare molecular ions in selected quantum states enables studies in areas such as chemistry, metrology, spectroscopy, quantum information, and precision measurements. Here, we demonstrate $(2+1)$ resonance-enhanced multiphoton ionization (REMPI) of oxygen, both in a molecular beam and in an ion trap. The two-photon transition in the REMPI spectrum is rotationally resolved, allowing…
▽ More
The ability to prepare molecular ions in selected quantum states enables studies in areas such as chemistry, metrology, spectroscopy, quantum information, and precision measurements. Here, we demonstrate $(2+1)$ resonance-enhanced multiphoton ionization (REMPI) of oxygen, both in a molecular beam and in an ion trap. The two-photon transition in the REMPI spectrum is rotationally resolved, allowing ionization from a selected rovibrational state of O$_2$. Fits to this spectrum determine spectroscopic parameters of the O$_2$ $d\,^1Π_g$ state and resolve a discrepancy in the literature regarding its band origin. The trapped molecular ions are cooled by co-trapped atomic ions. Fluorescence mass spectrometry nondestructively demonstrates the presence of the photoionized O$_2^+$. We discuss strategies for maximizing the fraction of ions produced in the ground rovibrational state. For $(2+1)$ REMPI through the $d\,^1Π_g$ state, we show that the Q(1) transition is preferred for neutral O$_2$ at rotational temperatures below 50~K, while the O(3) transition is more suitable at higher temperatures. The combination of state-selective loading and nondestructive detection of trapped molecular ions has applications in optical clocks, tests of fundamental physics, and control of chemical reactions.
△ Less
Submitted 3 February, 2025; v1 submitted 18 October, 2024;
originally announced October 2024.
-
The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
N. S. Alex,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos
, et al. (1348 additional authors not shown)
Abstract:
This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy los…
▽ More
This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.
△ Less
Submitted 26 December, 2024; v1 submitted 26 September, 2024;
originally announced September 2024.
-
An integrated evanescent-field biosensor in silicon
Authors:
Mohammed A. Al-Qadasi,
Samantha M. Grist,
Matthew Mitchell,
Karyn Newton,
Stephen Kioussis,
Sheri J. Chowdhury,
Avineet Randhawa,
Yifei Liu,
Piramon Tisapramotkul,
Karen C. Cheung,
Lukas Chrostowski,
Sudip Shekhar
Abstract:
Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world. Resonator-based biosensors using silicon photonic integrated circuits are a promising technology to meet this need, as they can leverage (1) semiconductor manufact…
▽ More
Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world. Resonator-based biosensors using silicon photonic integrated circuits are a promising technology to meet this need, as they can leverage (1) semiconductor manufacturing economies of scale, (2) exquisite optical sensitivity, and (3) the ability to integrate tens to hundreds of sensors on a millimeter-scale photonic chip. However, their application to decentralized testing has historically been limited by the expensive, bulky tunable lasers and alignment optics required for their readout. In this work, we introduce a segmented sensor architecture that addresses this important challenge by facilitating resonance-tracking readout using a fixed-wavelength laser. The architecture incorporates an in-resonator phase shifter modulated by CMOS drivers to periodically sweep and acquire the resonance peak shifts as well as a distinct high-sensitivity sensing region, maintaining high performance at a fraction of the cost and size. We show, for the first time, that fixed-wavelength sensor readout can offer similar performance to traditional tunable laser readout, demonstrating a system limit of detection of 6.1 x 10-5 RIU as well as immunoassay-based detection of the SARS-CoV-2 spike protein. We anticipate that this sensor architecture will open the door to a new data-rich class of portable, accurate, multiplexed diagnostics for decentralized testing.
△ Less
Submitted 21 October, 2024; v1 submitted 23 September, 2024;
originally announced September 2024.
-
DUNE Phase II: Scientific Opportunities, Detector Concepts, Technological Solutions
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1347 additional authors not shown)
Abstract:
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I…
▽ More
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy toward the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and Phase II, as did the European Strategy for Particle Physics. While the construction of the DUNE Phase I is well underway, this White Paper focuses on DUNE Phase II planning. DUNE Phase-II consists of a third and fourth far detector (FD) module, an upgraded near detector complex, and an enhanced 2.1 MW beam. The fourth FD module is conceived as a "Module of Opportunity", aimed at expanding the physics opportunities, in addition to supporting the core DUNE science program, with more advanced technologies. This document highlights the increased science opportunities offered by the DUNE Phase II near and far detectors, including long-baseline neutrino oscillation physics, neutrino astrophysics, and physics beyond the standard model. It describes the DUNE Phase II near and far detector technologies and detector design concepts that are currently under consideration. A summary of key R&D goals and prototyping phases needed to realize the Phase II detector technical designs is also provided. DUNE's Phase II detectors, along with the increased beam power, will complete the full scope of DUNE, enabling a multi-decadal program of groundbreaking science with neutrinos.
△ Less
Submitted 22 August, 2024;
originally announced August 2024.
-
First Measurement of the Total Inelastic Cross-Section of Positively-Charged Kaons on Argon at Energies Between 5.0 and 7.5 GeV
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti
, et al. (1341 additional authors not shown)
Abstract:
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/$c$ beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each…
▽ More
ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton liquid argon time projection chamber that operated in a hadron test beam at the CERN Neutrino Platform in 2018. We present a measurement of the total inelastic cross section of charged kaons on argon as a function of kaon energy using 6 and 7 GeV/$c$ beam momentum settings. The flux-weighted average of the extracted inelastic cross section at each beam momentum setting was measured to be 380$\pm$26 mbarns for the 6 GeV/$c$ setting and 379$\pm$35 mbarns for the 7 GeV/$c$ setting.
△ Less
Submitted 1 August, 2024;
originally announced August 2024.
-
Supernova Pointing Capabilities of DUNE
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electr…
▽ More
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on $^{40}$Ar and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called ``brems flipping'', as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE's burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage.
△ Less
Submitted 14 July, 2024;
originally announced July 2024.
-
Reviewing climate change attribution in UK natural hazards and their impacts
Authors:
Regan Mudhar,
Dann M. Mitchell,
Peter A. Stott,
Richard A. Betts
Abstract:
The field of Detection and Attribution is rapidly moving beyond weather and climate, and towards incorporating hazards and their impacts on natural and human systems. Here, we review the comprehensive literature base relevant for the UK ahead of the next Climate Change Risk Assessment. The current literature highlights a detectable and non-trivial influence of climate change in many UK impact sect…
▽ More
The field of Detection and Attribution is rapidly moving beyond weather and climate, and towards incorporating hazards and their impacts on natural and human systems. Here, we review the comprehensive literature base relevant for the UK ahead of the next Climate Change Risk Assessment. The current literature highlights a detectable and non-trivial influence of climate change in many UK impact sectors already - notably health, agriculture, and infrastructure. We found that heatwaves were the most studied hazard overall, with a unanimous consensus on a strong attributable signal of human-induced climate change in their increased frequency and intensity over the last century. The most notable gap identified overall was in attributing climate-related impacts to human influence, with a few impact studies for only a handful of the hazards assessed. Furthermore, just under half of the 29 hazards were not found to have any UK-relevant attribution studies, with most of the remainder having three or fewer. This review highlights requirements for and opportunities to develop attribution scicnce to meet the needs of the UK. Diversifying hazards and impacts studied, in conjunction with the techniques and approaches used, will undoubtedly benefit the community.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Functionalized mm-scale vapor cells for alkali-metal spectroscopy and magnetometry
Authors:
Harini Raghavan,
Michael C. D. Tayler,
Kostas Mouloudakis,
Rachel Rae,
Sami Lähteenmäki,
Rasmus Zetter,
Petteri Laine,
Jacques Haesler,
Laurent Balet,
Thomas Overstolz,
Sylvain Karlen,
Morgan W. Mitchell
Abstract:
We describe micro-fabricated rubidium vapor cells with integrated temperature-control functionality and demonstrate their suitability for use in miniaturized ultra-sensitive magnetometers. These functionalized vapor cells (FVCs) embody a dual-chamber design in low-conductivity silicon with anti-permeation coatings and micro-structured thin-film platinum surface traces as resistive heaters and temp…
▽ More
We describe micro-fabricated rubidium vapor cells with integrated temperature-control functionality and demonstrate their suitability for use in miniaturized ultra-sensitive magnetometers. These functionalized vapor cells (FVCs) embody a dual-chamber design in low-conductivity silicon with anti-permeation coatings and micro-structured thin-film platinum surface traces as resistive heaters and temperature sensors. Thermal tests show our ability to control alkali metal distribution within the FVCs, ensuring a clean sensing chamber for optical measurements. Optical absorption spectroscopy is used to correlate the temperature readings with vapor density and to measure buffer gas pressure, of interest for optimizing sensitivity. Finally, we demonstrate zero-field resonance magnetometry with 18 fT/Hz$^{1/2}$ sensitivity in the 10 Hz to 100 Hz band, limited by laser noise and magnetic shield noise, which indicates that the functionalization does not introduce significant magnetic noise.
△ Less
Submitted 7 September, 2024; v1 submitted 17 May, 2024;
originally announced May 2024.
-
GHz-rate optical phase shift in light matter interaction-engineered, silicon-ferroelectric nematic liquid crystals
Authors:
Iman Taghavi,
Omid Esmaeeli,
Sheri Jahan Chowdhury,
Kashif Awan,
Mustafa Hammood,
Matthew Mitchell,
Donald Witt,
Cory Pecinovsky,
Jason Sickler,
Jeff Young,
Nicolas A. F. Jaeger,
Sudip Shekhar,
Lukas Chrostowski
Abstract:
Organic electro-optic materials have demonstrated promising performance in developing electro-optic phase shifters. Their integration with other silicon photonic processes, nanofabrication complexities, and durability remains to be developed. While the required poling step in electro-optic polymers limits their potential and utilization on a large scale, devices made of paraelectric nematic liquid…
▽ More
Organic electro-optic materials have demonstrated promising performance in developing electro-optic phase shifters. Their integration with other silicon photonic processes, nanofabrication complexities, and durability remains to be developed. While the required poling step in electro-optic polymers limits their potential and utilization on a large scale, devices made of paraelectric nematic liquid crystals suffer from slow bandwidth. In ferroelectric nematic liquid crystals, we report an additional GHz-fast phase shift that ultimately allows for significant second-order nonlinear optical coefficients related to the Pockels effect. It avoids poling issues and can pave the way for hybrid silicon-organic systems with CMOS-foundry compatibility. We report DC and AC modulation efficiencies of $\approx$~0.25 V$\cdot$mm (from liquid crystal orientation) and $\approx$~25.7 V$\cdot$mm (from Pockels effect), respectively, an on-chip insertion loss of $\approx$~2.6 dB, and an electro-optic bandwidth of $f_\text{-6dB}$>4.18 GHz, employing improved light-matter interaction in a waveguide architecture that calls for only one lithography step.
△ Less
Submitted 8 February, 2025; v1 submitted 13 May, 2024;
originally announced May 2024.
-
Laser-written micro-channel atomic magnetometer
Authors:
Andrea Zanoni,
Kostas Mouloudakis,
Michael C. D. Tayler,
Giacomo Corrielli,
Roberto Osellame,
Morgan W. Mitchell,
Vito Giovanni Lucivero
Abstract:
We demonstrate a sensitive optically-pumped magnetometer using rubidium vapor and 0.75 amg of nitrogen buffer gas in a sub-mm-width sensing channel excavated by femtosecond laser writing followed by chemical etching. The channel is buried less than 1 mm below the surface of its fused silica host material, which also includes reservoir chambers and micro-strainer connections, to preserve a clean op…
▽ More
We demonstrate a sensitive optically-pumped magnetometer using rubidium vapor and 0.75 amg of nitrogen buffer gas in a sub-mm-width sensing channel excavated by femtosecond laser writing followed by chemical etching. The channel is buried less than 1 mm below the surface of its fused silica host material, which also includes reservoir chambers and micro-strainer connections, to preserve a clean optical environment. Using a zero-field-resonance magnetometry strategy and a sensing volume of 2.25 mm$^3$, we demonstrate a sensitivity of $\approx$ 1 $\mathrm{pT}/\sqrt{\mathrm{Hz}}$ at $10$ Hz. The device can be integrated with photonic structures and microfluidic channels with 3D versatility. Its sensitivity, bandwidth and stand-off distance will enable detection of localized fields from magnetic nanoparticles and \mul NMR samples.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
Quantum jump photodetector for narrowband photon counting with a single atom
Authors:
Laura Zarraoa,
Romain Veyron,
Tomas Lamich,
Lorena C. Bianchet,
Morgan W. Mitchell
Abstract:
Using a single neutral 87Rb atom held in an optical trap, and "quantum jump" detection of single-photon-initiated state changes, we demonstrate a single-photon quantum jump photodetector (QJPD) with intrinsically narrow bandwidth and strong rejection of out-of-band photons, of interest for detecting weak optical signals in the presence of a strong broadband background. By analyzing fluorescence ph…
▽ More
Using a single neutral 87Rb atom held in an optical trap, and "quantum jump" detection of single-photon-initiated state changes, we demonstrate a single-photon quantum jump photodetector (QJPD) with intrinsically narrow bandwidth and strong rejection of out-of-band photons, of interest for detecting weak optical signals in the presence of a strong broadband background. By analyzing fluorescence photon count distributions for the bright and dark states with and without excitation, we measure quantum efficiency of 2.9(2)$\times 10^{-3}$, a record for single-pass quantum jump production, and signal-photon-unprovoked "dark jump" rate - analogous to the dark count rate of other detectors - 3(10)$\times 10^{-3}$ jumps per second during passive accumulation plus 4.0(4)$\times 10^{-3}$ jumps per readout, orders of magnitude below those of traditional single-photon detectors. Available methods can substantially improve QJPD quantum efficiency, dark jump rate, bandwidth and tunability.
△ Less
Submitted 7 October, 2024; v1 submitted 13 March, 2024;
originally announced March 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Live magnetic observation of parahydrogen hyperpolarization dynamics
Authors:
James Eills,
Morgan W. Mitchell,
Irene Marco Rius,
Michael C. D. Tayler
Abstract:
Hyperpolarized nuclear spins in molecules exhibit high magnetization that is unachievable by classical polarization techniques, making them widely used as sensors in physics, chemistry, and medicine. The state of a hyperpolarized material, however, is typically only studied indirectly and with partial destruction of magnetization, due to the nature of conventional detection by resonant-pickup nucl…
▽ More
Hyperpolarized nuclear spins in molecules exhibit high magnetization that is unachievable by classical polarization techniques, making them widely used as sensors in physics, chemistry, and medicine. The state of a hyperpolarized material, however, is typically only studied indirectly and with partial destruction of magnetization, due to the nature of conventional detection by resonant-pickup nuclear magnetic resonance spectroscopy or imaging. Here we establish atomic magnetometers with sub-pT sensitivity as an alternative modality to detect in real time the complex dynamics of hyperpolarized materials without disturbing or interrupting the magnetogenesis process. As an example of dynamics that are impossible to detect in real time by conventional means, we examine parahydrogen-induced $^{1}$H and $^{13}$C magnetization during adiabatic eigenbasis transformations at $μ$T-field avoided crossings. Continuous but nondestructive magnetometry reveals previously unseen spin dynamics, fidelity limits, and magnetization backaction effects. As a second example, we apply magnetometry to observe the chemical-exchange-driven $^{13}$C hyperpolarization of [1--$^{13}$C]-pyruvate -- the most important spin tracer for clinical metabolic imaging. The approach can be readily combined with other high-sensitivity magnetometers and is applicable to a broader range of general observation scenarios involving production, transport and systems interaction of hyperpolarized compounds.
△ Less
Submitted 30 December, 2024; v1 submitted 16 February, 2024;
originally announced February 2024.
-
Doping Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1297 additional authors not shown)
Abstract:
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 2 August, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
Cavity-enhanced detection of spin polarization in a microfabricated atomic vapor cell
Authors:
María Hernández Ruiz,
Yintao Ma,
Hana Medhat,
Chiara Mazzinghi,
Vito Giovanni Lucivero,
Morgan W. Mitchell
Abstract:
We demonstrate continuous Pound-Drever-Hall (PDH) nondestructive monitoring of the electron spin polarization of an atomic vapor in a microfabricated vapor cell within an optical resonator. The two-chamber silicon and glass cell contains $^{87}$Rb and 1.3 amagat of N$_{2}$ buffer gas, and is placed within a planar optical resonator formed by two mirrors with dichroic dielectric coatings to resonan…
▽ More
We demonstrate continuous Pound-Drever-Hall (PDH) nondestructive monitoring of the electron spin polarization of an atomic vapor in a microfabricated vapor cell within an optical resonator. The two-chamber silicon and glass cell contains $^{87}$Rb and 1.3 amagat of N$_{2}$ buffer gas, and is placed within a planar optical resonator formed by two mirrors with dichroic dielectric coatings to resonantly enhance the coupling to phase-modulated probe light near the D$_2$ line at 780 nm. We describe the theory of signal generation in this system, including the spin-dependent complex refractive index, cavity optical transfer functions, and PDH signal response to spin polarization. We observe cavity transmission and PDH signals across $\approx 200$ GHz of detuning around the atomic resonance line. By resonant optical pumping on the 795 nm D$_1$ line, we observe spin-dependent cavity line shifts, in good agreement with theory. We use the saturation of the line shift vs. optical pumping power to calibrate the number density and efficiency of the optical pumping. In the unresolved sideband regime, we observe quantum-noise-limited PDH readout of the spin polarization density, with a flat noise floor of $9 \times 10^9$ spins cm$^{-3}$ Hz$^{-1/2}$ for frequencies above 700 Hz. We note possible extensions of the technique.
△ Less
Submitted 15 January, 2025; v1 submitted 19 December, 2023;
originally announced December 2023.
-
Telling different unravelings apart via nonlinear quantum-trajectory averages
Authors:
Eloy Piñol,
Th. K. Mavrogordatos,
Dustin Keys,
Romain Veyron,
Piotr Sierant,
Miguel Angel García-March,
Samuele Grandi,
Morgan W. Mitchell,
Jan Wehr,
Maciej Lewenstein
Abstract:
The Gorini-Kossakowski-Sudarshan-Lindblad master equation (ME) governs the density matrix of open quantum systems (OQSs). When an OQS is subjected to weak continuous measurement, its state evolves as a stochastic quantum trajectory, whose statistical average solves the ME. The ensemble of such trajectories is termed an unraveling of the ME. We propose a method to operationally distinguish unraveli…
▽ More
The Gorini-Kossakowski-Sudarshan-Lindblad master equation (ME) governs the density matrix of open quantum systems (OQSs). When an OQS is subjected to weak continuous measurement, its state evolves as a stochastic quantum trajectory, whose statistical average solves the ME. The ensemble of such trajectories is termed an unraveling of the ME. We propose a method to operationally distinguish unravelings produced by the same ME in different measurement scenarios, using nonlinear averages of observables over trajectories. We apply the method to the paradigmatic quantum nonlinear system of resonance fluorescence in a two-level atom. We compare the Poisson-type unraveling, induced by direct detection of photons scattered from the two-level emitter, and the Wiener-type unraveling, induced by phase-sensitive detection of the emitted field. We show that a quantum-trajectory-averaged variance is able to distinguish these measurement scenarios. We evaluate the performance of the method, which can be readily extended to more complex OQSs, under a range of realistic experimental conditions.
△ Less
Submitted 6 September, 2024; v1 submitted 6 December, 2023;
originally announced December 2023.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
120 GOPS Photonic Tensor Core in Thin-film Lithium Niobate for Inference and in-situ Training
Authors:
Zhongjin Lin,
Bhavin J. Shastri,
Shangxuan Yu,
Jingxiang Song,
Yuntao Zhu,
Arman Safarnejadian,
Wangning Cai,
Yanmei Lin,
Wei Ke,
Mustafa Hammood,
Tianye Wang,
Mengyue Xu,
Zibo Zheng,
Mohammed Al-Qadasi,
Omid Esmaeeli,
Mohamed Rahim,
Grzegorz Pakulski,
Jens Schmid,
Pedro Barrios,
Weihong Jiang,
Hugh Morison,
Matthew Mitchell,
Xun Guan,
Nicolas A. F. Jaeger,
Leslie A. n Rusch
, et al. (5 additional authors not shown)
Abstract:
Photonics offers a transformative approach to artificial intelligence (AI) and neuromorphic computing by enabling low-latency, high-speed, and energy-efficient computations. However, conventional photonic tensor cores face significant challenges in constructing large-scale photonic neuromorphic networks. Here, we propose a fully integrated photonic tensor core, consisting of only two thin-film lit…
▽ More
Photonics offers a transformative approach to artificial intelligence (AI) and neuromorphic computing by enabling low-latency, high-speed, and energy-efficient computations. However, conventional photonic tensor cores face significant challenges in constructing large-scale photonic neuromorphic networks. Here, we propose a fully integrated photonic tensor core, consisting of only two thin-film lithium niobate (TFLN) modulators, a III-V laser, and a charge-integration photoreceiver. Despite its simple architecture, it is capable of implementing an entire layer of a neural network with a computational speed of 120 GOPS, while also allowing flexible adjustment of the number of inputs (fan-in) and outputs (fan-out). Our tensor core supports rapid in-situ training with a weight update speed of 60 GHz. Furthermore, it successfully classifies (supervised learning) and clusters (unsupervised learning) 112 * 112-pixel images through in-situ training. To enable in-situ training for clustering AI tasks, we offer a solution for performing multiplications between two negative numbers.
△ Less
Submitted 8 October, 2024; v1 submitted 28 November, 2023;
originally announced November 2023.
-
Uniaxial compression of 3D printed samples with voids: laboratory measurements compared with predictions from Effective Medium Theory
Authors:
Filip P. Adamus,
Ashley Stanton-Yonge,
Thomas M. Mitchell,
David Healy,
Philip G. Meredith
Abstract:
3D printing technology offers the possibility of producing synthetic samples with accurately defined microstructures. As indicated by effective medium theory (EMT), the shapes, orientations, and sizes of voids significantly affect the overall elastic response of a solid body. By performing uniaxial compression tests on twenty types of 3D-printed samples containing voids of different geometries, we…
▽ More
3D printing technology offers the possibility of producing synthetic samples with accurately defined microstructures. As indicated by effective medium theory (EMT), the shapes, orientations, and sizes of voids significantly affect the overall elastic response of a solid body. By performing uniaxial compression tests on twenty types of 3D-printed samples containing voids of different geometries, we examine whether the measured effective elasticities are accurately predicted by EMT. To manufacture the sample, we selected printers that use different technologies; fused deposition modelling (FDM), and stereolithography (SLA). We show how printer settings (FDM case) or sample cure time (SLA case) affect the measured properties. We also examine the reproducibility of elasticity tests on identically designed samples. To obtain the range of theoretical predictions, we assume either uniform strain or uniform stress. Our study of over two hundred samples shows that measured effective elastic moduli can fit EMT predictions with an error of less than 5% using both FDM and SLA methods if certain printing specifications and sample design considerations are taken into account. Notably, we find that the pore volume fraction of the designed samples should be above 1% to induce a measurable softening effect, but below 5% to produce accurate EMT estimations that fit the measured elastic properties of the samples. Our results highlight both the strengths of EMT for predicting the effective properties of solids with low pore fraction volume microstructural configurations, and the limitations for high porosity microstructures.
△ Less
Submitted 21 October, 2023;
originally announced October 2023.
-
Fiber-taper collected emission from NV centers in high-$Q/V$ diamond microdisks
Authors:
Tamiko Masuda,
J. P. E. Hadden,
David P. Lake,
Matthew Mitchell,
Sigurd Flågan,
Paul E. Barclay
Abstract:
Fiber-coupled microdisks are a promising platform for enhancing the spontaneous emission from color centers in diamond. The measured cavity-enhanced emission from the microdisk is governed by the effective volume ($V$) of each cavity mode, the cavity quality factor ($Q$), and the coupling between the microdisk and the fiber. Here we observe photoluminescence from an ensemble of nitrogen-vacancy ce…
▽ More
Fiber-coupled microdisks are a promising platform for enhancing the spontaneous emission from color centers in diamond. The measured cavity-enhanced emission from the microdisk is governed by the effective volume ($V$) of each cavity mode, the cavity quality factor ($Q$), and the coupling between the microdisk and the fiber. Here we observe photoluminescence from an ensemble of nitrogen-vacancy centers into high $Q/V$ microdisk modes, which when combined with coherent spectroscopy of the microdisk modes, allows us to elucidate the relative contributions of these factors. The broad emission spectrum acts as an internal light source facilitating mode identification over several cavity free spectral ranges. Analysis of the fiber-taper collected microdisk emission reveals spectral filtering both by the cavity and the fiber-taper, the latter of which we find preferentially couples to higher-order microdisk modes. Coherent mode spectroscopy is used to measure $Q\sim 1\times10^{5}$ -- the highest reported values for diamond microcavities operating at visible wavelengths. With realistic optimization of the microdisk dimensions, we predict that Purcell factors of $\sim 50$ are within reach.
△ Less
Submitted 6 October, 2023;
originally announced October 2023.
-
Multiparameter quantum sensing and magnetic communications with a hybrid dc and rf optically pumped magnetometer
Authors:
Michał Lipka,
Aleksandra Sierant,
Charikleia Troullinou,
Morgan Mitchell
Abstract:
We introduce and demonstrate a hybrid optically pumped magnetometer (HOPM) that simultaneously measures one dc field component and one rf field component quadrature with a single atomic spin ensemble. The HOPM achieves sub-pT/$\sqrt{\mathrm{Hz}}$ sensitivity for both dc and rf fields, and is limited in sensitivity by spin projection noise at low frequencies and by photon shot noise at high frequen…
▽ More
We introduce and demonstrate a hybrid optically pumped magnetometer (HOPM) that simultaneously measures one dc field component and one rf field component quadrature with a single atomic spin ensemble. The HOPM achieves sub-pT/$\sqrt{\mathrm{Hz}}$ sensitivity for both dc and rf fields, and is limited in sensitivity by spin projection noise at low frequencies and by photon shot noise at high frequencies. We demonstrate with the HOPM a new application of multiparameter quantum sensing: background-cancelling spread spectrum magnetic communication. We encode a digital message as rf amplitude, spread among sixteen channels from \SI{29}{\kilo\hertz} to \SI{33}{\kilo\hertz} in a noisy magnetic environment, and observe quantum-noise-limited rf magnetic signal recovery enabled by quantum-noise-limited dc noise cancellation, reaching noise rejection of \SI{15}{\decibel} at \SI{100}{\hertz} and more than \SI{20}{\decibel} at \SI{60}{\hertz} and below. We measure signal fidelity versus signal strength and extrinsic noise in communication of a short text message. The combination of high sensitivity, quantum-noise-limited performance, and real-world application potential makes the HOPM ideally suited for study of high-performance multiparameter quantum sensing.
△ Less
Submitted 26 March, 2024; v1 submitted 27 August, 2023;
originally announced August 2023.
-
Inter-species spin-noise correlations in hot atomic vapors
Authors:
K. Mouloudakis,
F. Vouzinas,
A. Margaritakis,
A. Koutsimpela,
G. Mouloudakis,
V. Koutrouli,
M. Skotiniotis,
G. P. Tsironis,
M. Loulakis,
M. W. Mitchell,
G. Vasilakis,
I. K. Kominis
Abstract:
We report an experimental and theoretical study of spin noise correlations in a $^{87}$Rb-$^{133}$Cs unpolarized alkali-metal vapor dominated by spin-exchange collisions. We observe strong unequal-time inter-species correlations and account for these with a first-principles theoretical model. Since the two atomic species have different spin precession frequencies, the dual-species vapor enables th…
▽ More
We report an experimental and theoretical study of spin noise correlations in a $^{87}$Rb-$^{133}$Cs unpolarized alkali-metal vapor dominated by spin-exchange collisions. We observe strong unequal-time inter-species correlations and account for these with a first-principles theoretical model. Since the two atomic species have different spin precession frequencies, the dual-species vapor enables the use of an additional experimental handle, the applied magnetic field, for untangling various sub-types of spin correlations. In particular, the measured cross-correlation and auto-correlation spectra shed light on a number of spin-dynamic effects involving intra-atom, inter-atom, intra-species and inter-species correlations. Cross-correlation coefficients exceeding $60\%$ have been observed at low-magnetic fields, where the two spin species couple strongly via spin-exchange collisions. The understanding of such spontaneously generated correlations can motivate the design of quantum-enhanced measurements with single or multi-species spin-polarized alkali-metal vapors used in quantum sensing applications.
△ Less
Submitted 15 October, 2023; v1 submitted 24 August, 2023;
originally announced August 2023.
-
Quantum-enhanced magnetometry at optimal number density
Authors:
Charikleia Troullinou,
Vito Giovanni Lucivero,
Morgan W. Mitchell
Abstract:
We study the use of squeezed probe light and evasion of measurement back-action to enhance the sensitivity and measurement bandwidth of an optically-pumped magnetometer (OPM) at sensitivity-optimal atom number density. By experimental observation, and in agreement with quantum noise modeling, a spin-exchange-limited OPM probed with off-resonance laser light is shown to have an optimal sensitivity…
▽ More
We study the use of squeezed probe light and evasion of measurement back-action to enhance the sensitivity and measurement bandwidth of an optically-pumped magnetometer (OPM) at sensitivity-optimal atom number density. By experimental observation, and in agreement with quantum noise modeling, a spin-exchange-limited OPM probed with off-resonance laser light is shown to have an optimal sensitivity determined by density-dependent quantum noise contributions. Application of squeezed probe light boosts the OPM sensitivity beyond this laser-light optimum, allowing the OPM to achieve sensitivities that it cannot reach with coherent-state probing at any density. The observed quantum sensitivity enhancement at optimal number density is enabled by measurement back-action evasion.
△ Less
Submitted 24 August, 2023;
originally announced August 2023.
-
Feedback Enhanced Phonon Lasing of a Microwave Frequency Resonator
Authors:
Peyman Parsa,
Prasoon Kumar Shandilya,
David P. Lake,
Matthew E. Mitchell,
Paul E. Barclay
Abstract:
The amplitude of self-oscillating mechanical resonators in cavity optomechanical systems is typically limited by nonlinearities arising from the cavity's finite optical bandwidth. We propose and demonstrate a feedback technique for increasing this limit. By modulating the cavity input field with a signal derived from its output intensity, we increase the amplitude of a self-oscillating GHz frequen…
▽ More
The amplitude of self-oscillating mechanical resonators in cavity optomechanical systems is typically limited by nonlinearities arising from the cavity's finite optical bandwidth. We propose and demonstrate a feedback technique for increasing this limit. By modulating the cavity input field with a signal derived from its output intensity, we increase the amplitude of a self-oscillating GHz frequency mechanical resonator by $22\%$ (increase in coherent phonon number of $50\%$) limited only by the achievable optomechanical cooperativity of the system. This technique will advance applications dependent on high dynamic mechanical stress, such as coherent spin-phonon coupling, as well as implementations of sensors based on self-oscillating resonators.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
Anomalous noise spectra in a spin-exchange-relaxation-free alkali-metal vapor
Authors:
K. Mouloudakis,
J. Kong,
A. Sierant,
E. Arkin,
M. Hernández Ruiz,
R. Jiménez-Martínez,
M. W. Mitchell
Abstract:
We perform spin-noise spectroscopy on an unpolarized $^{87}\mathrm{Rb}$ vapor in the spin-exchange-relaxation-free (SERF) regime. We observe noise spectral distributions that deviate strongly from Lorentzian models that accurately describe lower-density regimes. For example, at magnetic fields of $\sim 1 \mathrm{μT}$ and $^{87}\mathrm{Rb}$ densities $\gtrsim 1 \times 10^{14} \rm{atoms/cm^{3}}$ we…
▽ More
We perform spin-noise spectroscopy on an unpolarized $^{87}\mathrm{Rb}$ vapor in the spin-exchange-relaxation-free (SERF) regime. We observe noise spectral distributions that deviate strongly from Lorentzian models that accurately describe lower-density regimes. For example, at magnetic fields of $\sim 1 \mathrm{μT}$ and $^{87}\mathrm{Rb}$ densities $\gtrsim 1 \times 10^{14} \rm{atoms/cm^{3}}$ we observe an asymmetric spin-noise distribution in which the resonance line is depleted by about half its power, with the diverted power becoming a broad spectral component that could be mistaken for optical shot noise. The results are in good agreement with recent models accounting for correlations between the ground hyperfine states. We discuss implications for quantum sensing and absolute noise calibration in spin-squeezing and entanglement detection.
△ Less
Submitted 28 March, 2024; v1 submitted 31 July, 2023;
originally announced July 2023.
-
Can AI Put Gamma-Ray Astrophysicists Out of a Job?
Authors:
Samuel T. Spencer,
Vikas Joshi,
Alison M. W. Mitchell
Abstract:
In what will likely be a litany of generative-model-themed arXiv submissions celebrating April the 1st, we evaluate the capacity of state-of-the-art transformer models to create a paper detailing the detection of a Pulsar Wind Nebula with a non-existent Imaging Atmospheric Cherenkov Telescope (IACT) Array. We do this to evaluate the ability of such models to interpret astronomical observations and…
▽ More
In what will likely be a litany of generative-model-themed arXiv submissions celebrating April the 1st, we evaluate the capacity of state-of-the-art transformer models to create a paper detailing the detection of a Pulsar Wind Nebula with a non-existent Imaging Atmospheric Cherenkov Telescope (IACT) Array. We do this to evaluate the ability of such models to interpret astronomical observations and sources based on language information alone, and to assess potential means by which fraudulently generated scientific papers could be identified during peer review (given that reliable generative model watermarking has yet to be deployed for these tools). We conclude that our jobs as astronomers are safe for the time being. From this point on, prompts given to ChatGPT and Stable Diffusion are shown in orange, text generated by ChatGPT is shown in black, whereas analysis by the (human) authors is in blue.
△ Less
Submitted 4 April, 2023; v1 submitted 31 March, 2023;
originally announced March 2023.
-
Multi-porous extension of anisotropic poroelasticity: linkage with micromechanics
Authors:
Filip P. Adamus,
David Healy,
Philip G. Meredith,
Thomas M. Mitchell
Abstract:
We attempt to formalise the relationship between the poroelasticity theory and the effective medium theory of micromechanics. The assumptions of these two approaches vary, but both can be linked by considering the undrained response of a material; and that is the main focus of the paper. To analyse the linkage between poroelasticity and micromechanics, we do not limit ourselves to the original the…
▽ More
We attempt to formalise the relationship between the poroelasticity theory and the effective medium theory of micromechanics. The assumptions of these two approaches vary, but both can be linked by considering the undrained response of a material; and that is the main focus of the paper. To analyse the linkage between poroelasticity and micromechanics, we do not limit ourselves to the original theory of Biot. Instead, we consider a multi-porous extension of anisotropic poroelasticity, where pore fluid pressure may vary within the bulk medium of interest. As a consequence, any inhomogeneities in the material are not necessarily interconnected; instead, they may form isolated pore sets that are described by different poroelastic parameters and fluid pressures. We attempt to incorporate the effective methods inside Biot-like theory and investigate the poroelastic response of various microstructures. We show the cases where such implementation is valid and the others that appear to be questionable. During micromechanical analysis, we derive a particular case of cylindrical transverse isotropy -- commonly assumed in conventional laboratory triaxial tests -- where the symmetry is induced by sets of aligned cracks.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Multi-porous extension of anisotropic poroelasticity: consolidation and related coefficients
Authors:
Filip P. Adamus,
David Healy,
Philip G. Meredith,
Thomas M. Mitchell,
Ashley Stanton-Yonge
Abstract:
We propose the generalisation of the anisotropic poroelasticity theory. At a large scale, a medium is viewed as quasi-static, which is the original assumption of Biot. At a smaller scale, we distinguish different porosity clusters (sets of pores or fractures) that are characterized by various fluid pressures, which is the original poroelastic extension of Aifantis. In consequence, both instantaneo…
▽ More
We propose the generalisation of the anisotropic poroelasticity theory. At a large scale, a medium is viewed as quasi-static, which is the original assumption of Biot. At a smaller scale, we distinguish different porosity clusters (sets of pores or fractures) that are characterized by various fluid pressures, which is the original poroelastic extension of Aifantis. In consequence, both instantaneous and time-dependent deformation lead to fluid content variations that are different in each cluster. We present the equations for such phenomena, where the anisotropic properties of both the solid matrix and pore sets are assumed. Novel poroelastic coefficients that relate solid and fluid phases in our extension are proposed, and their physical meaning is determined. To demonstrate the utility of our equations and emphasize the meaning of new coefficients, we perform numerical simulations of a triple-porosity consolidation. These simulations reveal positive pore pressure transients in the drained behaviour of weakly connected pore sets, and these may result in mechanical weakening of the material.
△ Less
Submitted 18 May, 2023; v1 submitted 8 March, 2023;
originally announced March 2023.
-
Real-time polarimetry of hyperpolarized $^{13}$C nuclear spins using an atomic magnetometer
Authors:
Kostas Mouloudakis,
Sven Bodenstedt,
Marc Azagra,
Morgan W Mitchell,
Irene Marco-Rius,
Michael CD Tayler
Abstract:
We introduce a method for non-destructive quantification of nuclear spin polarization, of relevance to hyperpolarized spin tracers widely used in magnetic resonance from spectroscopy to in vivo imaging. In a bias field of around 30 nT we use a high-sensitivity miniaturized $^{87}$Rb vapor magnetometer to measure the field generated by the sample, as it is driven by a windowed dynamical decoupling…
▽ More
We introduce a method for non-destructive quantification of nuclear spin polarization, of relevance to hyperpolarized spin tracers widely used in magnetic resonance from spectroscopy to in vivo imaging. In a bias field of around 30 nT we use a high-sensitivity miniaturized $^{87}$Rb vapor magnetometer to measure the field generated by the sample, as it is driven by a windowed dynamical decoupling pulse sequence that both maximizes the nuclear spin lifetime and modulates the polarization for easy detection. We demonstrate the procedure applied to a 0.08 M hyperpolarized [1--$^{13}$C]-pyruvate solution produced by dissolution dynamic nuclear polarization, measuring polarization repeatedly during natural decay at Earth's field. Application to real-time quality monitoring of hyperpolarized substances is discussed.
△ Less
Submitted 12 September, 2023; v1 submitted 16 January, 2023;
originally announced January 2023.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1235 additional authors not shown)
Abstract:
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is…
▽ More
Measurements of electrons from $ν_e$ interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectrum is derived and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50~MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.
△ Less
Submitted 31 May, 2023; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Meridional composite pulses for low-field magnetic resonance
Authors:
Sven Bodenstedt,
Morgan W. Mitchell,
Michael C. D. Tayler
Abstract:
We discuss procedures for error-tolerant spin control in environments that permit transient, large-angle reorientation of magnetic bias field. Short sequences of pulsed, non-resonant magnetic field pulses in a laboratory-frame meridional plane are derived. These are shown to have band-pass excitation properties comparable to established amplitude-modulated, resonant pulses used in high, static-fie…
▽ More
We discuss procedures for error-tolerant spin control in environments that permit transient, large-angle reorientation of magnetic bias field. Short sequences of pulsed, non-resonant magnetic field pulses in a laboratory-frame meridional plane are derived. These are shown to have band-pass excitation properties comparable to established amplitude-modulated, resonant pulses used in high, static-field magnetic resonance. Using these meridional pulses, we demonstrate robust $z$ inversion in proton ($^{1}$H) nuclear magnetic resonance near earth's field.
△ Less
Submitted 23 June, 2022;
originally announced June 2022.
-
Precise, super-resolving intensity measurement by quantum jump spectroscopy of a single neutral atom
Authors:
Lorena C. Bianchet,
Natalia Alves,
Laura Zarraoa,
Tomas Lamich,
Vindhiya Prakash,
Morgan W. Mitchell
Abstract:
We present precise, sub-wavelength optical intensity measurement using a single trapped $^{87}$Rb atom as a sensor. The intensity is measured by the scalar ac Stark shift it produces on the $F=1 \rightarrow F'=2$ hyperfine transition of the D$_{2}$ line, chosen for its $F' = F+1$ structure and very small tensor polarizability. To boost signal and reduce measurement-induced perturbations, we use a…
▽ More
We present precise, sub-wavelength optical intensity measurement using a single trapped $^{87}$Rb atom as a sensor. The intensity is measured by the scalar ac Stark shift it produces on the $F=1 \rightarrow F'=2$ hyperfine transition of the D$_{2}$ line, chosen for its $F' = F+1$ structure and very small tensor polarizability. To boost signal and reduce measurement-induced perturbations, we use a quantum jump spectroscopy technique in which a single absorbed photon on a transition of interest induces the scattering of hundreds of photons on a bright closed transition. The method greatly reduces systematic effects associated with the atomic state, optical polarization, probe power, and atom heating, and gives the atomic temperature as a second spectroscopic observable. We demonstrate the method by measuring the intensity at the focus of an optical tweezer.
△ Less
Submitted 29 July, 2024; v1 submitted 27 May, 2022;
originally announced May 2022.
-
Effects of spin-exchange collisions on the fluctuation spectra of hot alkali-metal vapors
Authors:
K. Mouloudakis,
G. Vasilakis,
V. G. Lucivero,
J. Kong,
I. K. Kominis,
M. W. Mitchell
Abstract:
We present a first-principles analysis of the noise spectra of alkali-metal-metal vapors in and out of the spin-exchange-relaxation-free (SERF) regime, and we predict non-intuitive features with a potential to further improve the sensitivity of SERF media, and which must be taken into account in their use in quantum optical applications. Studying the process of spin-noise spectroscopy (SNS), we de…
▽ More
We present a first-principles analysis of the noise spectra of alkali-metal-metal vapors in and out of the spin-exchange-relaxation-free (SERF) regime, and we predict non-intuitive features with a potential to further improve the sensitivity of SERF media, and which must be taken into account in their use in quantum optical applications. Studying the process of spin-noise spectroscopy (SNS), we derive analytic formulas for the observable noise spectra, and for the correlation functions among different hyperfine components, which give additional insight into the spin dynamics. The analytic results indicate a variety of distortions of the spin-noise spectrum relative to simpler models, including a broad spectral background that mimics optical shot noise, interference of noise contributions from the two ground-state hyperfine levels, noise reduction at the spin-precession frequency, and ``hiding'' of spin-noise power that can introduce a systematic error in noise-based calibrations, e.g., for spin-squeezing experiments.
△ Less
Submitted 22 December, 2022; v1 submitted 19 April, 2022;
originally announced April 2022.
-
Miniature biplanar coils for alkali-metal-vapor magnetometry
Authors:
Michael C. D. Tayler,
Kostas Mouloudakis,
Rasmus Zetter,
Dominic Hunter,
Vito G. Lucivero,
Sven Bodenstedt,
Lauri Parkkonen,
Morgan W. Mitchell
Abstract:
Atomic spin sensors offer precision measurements using compact, microfabricated packages, placing them in a competitive position for both market and research applications. Performance of these sensors such as dynamic range may be enhanced through magnetic field control. In this work, we discuss the design of miniature coils for three-dimensional, localized field control by direct placement around…
▽ More
Atomic spin sensors offer precision measurements using compact, microfabricated packages, placing them in a competitive position for both market and research applications. Performance of these sensors such as dynamic range may be enhanced through magnetic field control. In this work, we discuss the design of miniature coils for three-dimensional, localized field control by direct placement around the sensor, as a flexible and compact alternative to global approaches used previously. Coils are designed on biplanar surfaces using a stream-function approach and then fabricated using standard printed-circuit techniques. Application to a laboratory-scale optically pumped magnetometer of sensitivity approximately 20 fT/Hz$^{1/2}$ is shown. We also demonstrate the performance of a coil set measuring $7 \times 17 \times 17$ mm$^3$ that is optimized specifically for magnetoencephalography, where multiple sensors are operated in proximity to one another. Characterization of the field profile using $^{87}$Rb free-induction spectroscopy and other techniques show $>$96% field homogeneity over the target volume of a MEMS vapor cell and a compact stray field contour of approximately 1% at 20 mm from the center of the cell.
△ Less
Submitted 11 August, 2022; v1 submitted 4 April, 2022;
originally announced April 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Laser-written vapor cells for chip-scale atomic sensing and spectroscopy
Authors:
Vito Giovanni Lucivero,
Andrea Zanoni,
Giacomo Corrielli,
Roberto Osellame,
Morgan W. Mitchell
Abstract:
We report the fabrication of alkali-metal vapor cells using femtosecond laser machining. This laser-written vapor-cell (LWVC) technology allows arbitrarily-shaped 3D interior volumes and has potential for integration with photonic structures and optical components. We use non-evaporable getters both to dispense rubidium and to absorb buffer gas. This enables us to produce cells with sub-atmospheri…
▽ More
We report the fabrication of alkali-metal vapor cells using femtosecond laser machining. This laser-written vapor-cell (LWVC) technology allows arbitrarily-shaped 3D interior volumes and has potential for integration with photonic structures and optical components. We use non-evaporable getters both to dispense rubidium and to absorb buffer gas. This enables us to produce cells with sub-atmospheric buffer gas pressures without vacuum apparatus. We demonstrate sub-Doppler saturated absorption spectroscopy and single beam optical magnetometry with a single LWVC. The LWVC technology may find application in miniaturized atomic quantum sensors and frequency references.
△ Less
Submitted 13 July, 2022; v1 submitted 18 February, 2022;
originally announced February 2022.
-
Nonlinear optics in gallium phosphide cavities: simultaneous second and third harmonic generation
Authors:
Blaine McLaughlin,
David P. Lake,
Matthew Mitchell,
Paul E. Barclay
Abstract:
We demonstrate the simultaneous generation of second and third harmonic signals from a telecom wavelength pump in a gallium phosphide (GaP) microdisk. Using analysis of the power scaling of both the second and third harmonic outputs and calculations of nonlinear cavity mode coupling factors, we study contributions to the third harmonic signal from direct and cascaded sum frequency generation proce…
▽ More
We demonstrate the simultaneous generation of second and third harmonic signals from a telecom wavelength pump in a gallium phosphide (GaP) microdisk. Using analysis of the power scaling of both the second and third harmonic outputs and calculations of nonlinear cavity mode coupling factors, we study contributions to the third harmonic signal from direct and cascaded sum frequency generation processes. We find that despite the relatively high material absorption in gallium phosphide at the third harmonic wavelength, both of these processes can be significant, with relative magnitudes that depend closely on the detuning between the second harmonic wavelength of the cavity modes.
△ Less
Submitted 6 July, 2022; v1 submitted 31 January, 2022;
originally announced February 2022.
-
Decoupling of Spin Decoherence Paths near Zero Magnetic Field
Authors:
Sven Bodenstedt,
Morgan W. Mitchell,
Michael C. D. Tayler
Abstract:
We demonstrate a method to quantify and manipulate nuclear spin decoherence mechanisms that are active in zero to ultralow magnetic fields. These include: (i) non-adiabatic switching of spin quantization axis, due to residual background fields; (ii) scalar pathways due to through-bond couplings between $^1$H and heteronuclear spin species, such as $^2$H used partially as an isotopic substitute for…
▽ More
We demonstrate a method to quantify and manipulate nuclear spin decoherence mechanisms that are active in zero to ultralow magnetic fields. These include: (i) non-adiabatic switching of spin quantization axis, due to residual background fields; (ii) scalar pathways due to through-bond couplings between $^1$H and heteronuclear spin species, such as $^2$H used partially as an isotopic substitute for $^1$H. Under conditions of free evolution, scalar relaxation due to $^2$H can significantly limit nuclear spin polarization lifetimes and thus the scope of magnetic resonance procedures near zero field. It is shown that robust trains of pulsed dc magnetic fields that apply $π$ flip angles to one or multiple spin species may switch effective symmetry of the nuclear spin Hamiltonian, imposing decoupled or coupled dynamic regimes on demand. The method should broaden the spectrum of hyperpolarized biomedical contrast-agent compounds and hyperpolarization procedures that are used near zero field.
△ Less
Submitted 15 December, 2021;
originally announced December 2021.
-
Improving Short-Term Stability in Optical Lattice Clocks by Quantum Nondemolition Measurements
Authors:
Daniel Benedicto Orenes,
Robert J. Sewell,
Jérôme Lodewyck,
Morgan W. Mitchell
Abstract:
We propose a multimeasurement estimation protocol for Quantum Nondemolition (QND) measurements in a Rabi clock interferometer. The method is well suited for current state-of-the-art optical lattice clocks with QND measurement capabilities. The protocol exploits the correlations between multiple non-destructive measurements of the initially prepared coherent spin state. A suitable Gaussian estimato…
▽ More
We propose a multimeasurement estimation protocol for Quantum Nondemolition (QND) measurements in a Rabi clock interferometer. The method is well suited for current state-of-the-art optical lattice clocks with QND measurement capabilities. The protocol exploits the correlations between multiple non-destructive measurements of the initially prepared coherent spin state. A suitable Gaussian estimator for the clock laser detuning is presented, and an analytic expression for the sensitivity of the protocol is derived. We use this analytic expression to optimise the protocol using available experimental parameters, achieving an improvement of $7.9$dB with respect to the standard quantum limit (SQL) in terms of clock stability. We also discuss the measurement back-action effects of our protocol into the atomic state.
△ Less
Submitted 17 May, 2022; v1 submitted 17 September, 2021;
originally announced September 2021.
-
Single-domain Bose condensate magnetometer achieves energy resolution per bandwidth below $\hbar$
Authors:
Silvana Palacios Alvarez,
Pau Gomez,
Simon Coop,
Roberto Zamora-Zamora,
Chiara Mazzinghi,
Morgan W. Mitchell
Abstract:
We present a magnetic sensor with energy resolution per bandwidth $E_R < \hbar$. We show how a $^{87}\mathrm{Rb}$ single domain spinor Bose-Einstein condensate, detected by non-destructive Faraday-rotation probing, achieves single shot dc magnetic sensitivity of $72(8)~\mathrm{fT}$ measuring a volume $V= 1091(30)~μ\mathrm{m}^3$ for $3.5~\mathrm{s}$, and thus $E_R = 0.075(16)~\hbar$. We measure exp…
▽ More
We present a magnetic sensor with energy resolution per bandwidth $E_R < \hbar$. We show how a $^{87}\mathrm{Rb}$ single domain spinor Bose-Einstein condensate, detected by non-destructive Faraday-rotation probing, achieves single shot dc magnetic sensitivity of $72(8)~\mathrm{fT}$ measuring a volume $V= 1091(30)~μ\mathrm{m}^3$ for $3.5~\mathrm{s}$, and thus $E_R = 0.075(16)~\hbar$. We measure experimentally the condensate volume, spin coherence time, and readout noise, and use phase-space methods, backed by 3+1D mean-field simulations, to compute the spin noise. Contributions to the spin noise include one-body and three-body losses and shearing of the projection noise distribution, due to competition of ferromagnetic contact interactions and quadratic Zeeman shifts. Nonetheless, the fully-coherent nature of the single-domain, ultracold two-body interactions allows the system to escape the coherence vs.~density trade-off that imposes an energy resolution limit on traditional spin-precession sensors. We predict that other Bose-condensed alkalis, especially the antiferromagnetic $^{23}\mathrm{Na}$, can further improve the energy resolution of this method.
△ Less
Submitted 28 January, 2022; v1 submitted 26 August, 2021;
originally announced August 2021.
-
Squeezed-light enhancement and backaction evasion in a high sensitivity optically pumped magnetometer
Authors:
C. Troullinou,
R. Jiménez-Martínez,
J. Kong,
V. G. Lucivero,
M. W. Mitchell
Abstract:
We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer. We use Bell-Bloom (BB) optical pumping to excite a $^{87}$Rb vapor containing $8.2 \cdot 10^{12} \mathrm{atoms/cm^3}$ and Faraday rotation to detect spin precession. The sub-$\mathrm{pT}/\sqrt{\mathrm{Hz}}$ sensitivity is limited by spin projection noise (ph…
▽ More
We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer. We use Bell-Bloom (BB) optical pumping to excite a $^{87}$Rb vapor containing $8.2 \cdot 10^{12} \mathrm{atoms/cm^3}$ and Faraday rotation to detect spin precession. The sub-$\mathrm{pT}/\sqrt{\mathrm{Hz}}$ sensitivity is limited by spin projection noise (photon shot noise) at low (high) frequencies. Probe polarization squeezing both improves high-frequency sensitivity and increases measurement bandwidth, with no loss of sensitivity at any frequency, a direct demonstration of the evasion of measurement backaction noise. We provide a model for the quantum noise dynamics of the BB magnetometer, including spin projection noise, probe polarization noise, and measurement backaction effects. The theory shows how polarization squeezing reduces optical noise, while measurement backaction due to the accompanying ellipticity anti-squeezing is shunted into the unmeasured spin component. The method is compatible with high-density and multi-pass techniques that reach extreme sensitivity.
△ Less
Submitted 4 November, 2021; v1 submitted 3 August, 2021;
originally announced August 2021.
-
Cavity-enhanced polarization rotation measurements for low-disturbance probing of atoms
Authors:
Chiara Mazzinghi,
Daniel Benedicto Orenes,
Pau Gomez,
Vito G. Lucivero,
Enes Aybar,
Stuti Gugnani,
Morgan W. Mitchell
Abstract:
We propose and demonstrate cavity-enhanced polarization-rotation measurement as a means to detect magnetic effects in transparent media with greater sensitivity at equal optical disturbance to the medium. Using the Jones calculus, we compute the effective polarization rotation effect in a Fabry-Perot cavity containing a magnetic medium, including losses due to enclosure windows or other sources. T…
▽ More
We propose and demonstrate cavity-enhanced polarization-rotation measurement as a means to detect magnetic effects in transparent media with greater sensitivity at equal optical disturbance to the medium. Using the Jones calculus, we compute the effective polarization rotation effect in a Fabry-Perot cavity containing a magnetic medium, including losses due to enclosure windows or other sources. The results show that when measuring polarization rotation, collecting the transmitted light has advantages in simplicity and linearity relative to collecting the reflected light. We demonstrate the technique by measuring Faraday rotation in a $^{87}$Rb atomic ensemble in the single-pass and cavity-enhanced geometries, and observe enhancement in good agreement with the theoretical predictions. We also demonstrate shot-noise-limited operation of the enhanced rotation scheme in the small-angle regime.
△ Less
Submitted 29 November, 2021; v1 submitted 28 July, 2021;
originally announced July 2021.
-
The roles of latent heating and dust in the structure and variability of the northern Martian polar vortex
Authors:
E. R. Ball,
D. M. Mitchell,
W. J. M. Seviour,
S. I. Thomson,
G. K. Vallis
Abstract:
The winter polar vortices on Mars are annular in terms of their potential vorticity (PV) structure, a phenomenon identified in observations, reanalysis and some numerical simulations. Some recent modeling studies have proposed that condensation of atmospheric carbon dioxide at the winter pole is a contributing factor to maintaining the annulus through the release of latent heat. Dust and topograph…
▽ More
The winter polar vortices on Mars are annular in terms of their potential vorticity (PV) structure, a phenomenon identified in observations, reanalysis and some numerical simulations. Some recent modeling studies have proposed that condensation of atmospheric carbon dioxide at the winter pole is a contributing factor to maintaining the annulus through the release of latent heat. Dust and topographic forcing are also known to be causes of internal and interannual variability in the polar vortices. However, coupling between these factors remains uncertain, and previous studies of their impact on vortex structure and variability have been largely limited to a single Martian global climate model (MGCM). Here, by further developing a novel MGCM, we decompose the relative roles of latent heat and dust as drivers for the variability and structure of the northern Martian polar vortex. We also consider how Martian topography modifies the driving response. By also analyzing a reanalysis dataset we show that there is significant dependence in the polar vortex structure and variability on the observations assimilated. In both model and reanalysis, high atmospheric dust loading (such as that seen during a global dust storm) can disrupt the vortex, cause the destruction of PV in the low-mid altitudes (> 0.1 hPa), and significantly reduce spatial and temporal vortex variability. Through our simulations, we find that the combination of dust and topography primarily drives the eddy activity throughout the Martian year, and that although latent heat release can produce an annular vortex, it has a relatively minor effect on vortex variability.
△ Less
Submitted 29 September, 2021; v1 submitted 1 April, 2021;
originally announced April 2021.
-
Manipulating and measuring single atoms in the Maltese cross geometry
Authors:
Lorena C. Bianchet,
Natalia Alves,
Laura Zarraoa,
Natalia Bruno,
Morgan W. Mitchell
Abstract:
We describe optical methods for trapping, cooling, and observing single $^{87}$Rb atoms in a four-lens "Maltese cross" geometry (MCG). The use of four high numerical-aperture lenses in the cardinal directions enables efficient collection of light from non-collinear directions, but also restricts the optical access for cooling and optical pumping tasks. We demonstrate three-dimensional atom localiz…
▽ More
We describe optical methods for trapping, cooling, and observing single $^{87}$Rb atoms in a four-lens "Maltese cross" geometry (MCG). The use of four high numerical-aperture lenses in the cardinal directions enables efficient collection of light from non-collinear directions, but also restricts the optical access for cooling and optical pumping tasks. We demonstrate three-dimensional atom localization with sub-wavelength precision, and present measurements of the trap lifetime, temperature and transverse trap frequency in this geometry. We observe a trap performance comparable to what has been reported for single-atom traps with one- or two-lens optical systems, and conclude that the additional coupling directions provided by the MCG come at little cost to other trap characteristics.
△ Less
Submitted 9 March, 2021;
originally announced March 2021.
-
Optomechanical interface between telecom photons and spin quantum memory
Authors:
Prasoon K Shandilya,
David P Lake,
Matthew J Mitchell,
Denis D Sukachev,
Paul E Barclay
Abstract:
Quantum networks enable a broad range of practical and fundamental applications spanning distributed quantum computing to sensing and metrology. A cornerstone of such networks is an interface between telecom photons and quantum memories. Here we demonstrate a novel approach based on cavity optomechanics that utilizes the susceptibility of spin qubits to strain. We use it to control electron spins…
▽ More
Quantum networks enable a broad range of practical and fundamental applications spanning distributed quantum computing to sensing and metrology. A cornerstone of such networks is an interface between telecom photons and quantum memories. Here we demonstrate a novel approach based on cavity optomechanics that utilizes the susceptibility of spin qubits to strain. We use it to control electron spins of nitrogen-vacancy centers in diamond with photons in the 1550 nm telecommunications wavelength band. This method does not involve qubit optical transitions and is insensitive to spectral diffusion. Furthermore, our approach can be applied to solid-state qubits in a wide variety of materials, expanding the toolbox for quantum information processing.
△ Less
Submitted 11 June, 2021; v1 submitted 8 February, 2021;
originally announced February 2021.