-
Proof-of-Principle Experiment on a Displacement-Noise-Free Neutron Interferometer for Gravitational Wave Detection
Authors:
Shoki Iwaguchi,
Takuhiro Fujiie,
Taro Nambu,
Masaaki Kitaguchi,
Yutaka Yamagata,
Kenji Mishima,
Atsushi Nishizawa,
Tomohiro Ishikawa,
Kenji Tsuji,
Kurumi Umemura,
Kazuhiro Kobayashi,
Takafumi Onishi,
Keiko Kokeyama,
Hirohiko Shimizu,
Yuta Michimura,
Seiji Kawamura
Abstract:
The displacement-noise-free interferometer (DFI) is designed to eliminate all displacement-induced noise while retaining sensitivity to gravitational wave (GW) signals. Ground-based DFIs suffer from physical arm-length limitations, resulting in poor sensitivity at frequencies below 1 kHz. To address this, previous research introduced a neutron-based DFI, which replaces laser light with neutrons an…
▽ More
The displacement-noise-free interferometer (DFI) is designed to eliminate all displacement-induced noise while retaining sensitivity to gravitational wave (GW) signals. Ground-based DFIs suffer from physical arm-length limitations, resulting in poor sensitivity at frequencies below 1 kHz. To address this, previous research introduced a neutron-based DFI, which replaces laser light with neutrons and achieves exceptional sensitivity down to a few hertz. In this study, we conducted a proof-of-principle experiment using a pulsed neutron source at the Japan Proton Accelerator Research Complex (J- PARC). Despite practical constraints that led to deviations from the ideal experimental design, we optimized the setup and developed a novel analysis method that successfully cancels displacement noise while preserving simulated GW signals. This work presents the first successful demonstration of a neutron DFI and a neutron interferometer for GW detection.
△ Less
Submitted 22 May, 2025;
originally announced May 2025.
-
Measurement of Neutron Whispering Gallery States Using a Pulsed Neutron Beam
Authors:
Go Ichikawa,
Kenji Mishima
Abstract:
A neutron whispering gallery state is a quantum state localized on a material surface bound by the centrifugal force and the material potential. Precise measurements of such quantum states enable tests of quantum mechanics in non-inertial frames, characterization of the surface potential, and searches for hypothetical short-range interactions at the nanometer scale. We observed a neutron whisperin…
▽ More
A neutron whispering gallery state is a quantum state localized on a material surface bound by the centrifugal force and the material potential. Precise measurements of such quantum states enable tests of quantum mechanics in non-inertial frames, characterization of the surface potential, and searches for hypothetical short-range interactions at the nanometer scale. We observed a neutron whispering gallery state on a $\mathrm{SiO}_2$ concave mirror using a pulsed cold neutron beam. The measured results agree with theoretical calculations within $1.9\%$ for the centrifugal acceleration $a \approx 7\times 10^7\,\mathrm{m/s^2}$, which is due to unmodeled deviations of the shape of the concave mirror edge from an ideal one. We found that the sensitivity itself was $1\times 10^{-4}$, which is two orders of magnitude better than the above agreement.
△ Less
Submitted 18 April, 2025; v1 submitted 26 February, 2025;
originally announced February 2025.
-
A Comparative Study of Neutron Irradiation for Genetic Mutations: Spallation, Reactor, and Compact Neutron Source
Authors:
May Sweet,
Kenji Mishima,
Masahide Harada,
Keisuke Kurita,
Hiroshi Iikura,
Seiji Tasaki,
Norio Kikuchi
Abstract:
Neutron beam, being electrically neutral and highly penetrating, offers unique advantages for irradiation of biological species such as plants, seeds, and microorganisms. We comprehensively investigate the potential of neutron irradiation for inducing genetic mutations using simulations of J-PARC BL10, JRR-3 TNRF, and KUANS for spallation, reactor, and compact neutron sources. We analyze neutron f…
▽ More
Neutron beam, being electrically neutral and highly penetrating, offers unique advantages for irradiation of biological species such as plants, seeds, and microorganisms. We comprehensively investigate the potential of neutron irradiation for inducing genetic mutations using simulations of J-PARC BL10, JRR-3 TNRF, and KUANS for spallation, reactor, and compact neutron sources. We analyze neutron flux, energy deposition rates, and Linear Energy Transfer (LET) distributions. KUANS demonstrated the highest dose rate of 17 Gy/h, significantly surpassing BL10, due to the large solid angle by the optimal sample placement. The findings highlight KUANS's suitability for efficient genetic mutations and neutron breeding, particularly for inducing targeted mutations in biological samples. The LET range of KUANS is concentrated in 20-70 keV/μm, which is potentially ideal for inducing specific genetic mutations. The importance of choosing neutron sources based on LET requirements to maximize mutation induction efficiency is emphasized. This research shows the potential of compact neutron sources like KUANS for effective biological irradiation and neutron breeding, offering a viable alternative to larger facilities. The neutron filters used in BL10 and TNRF effectively excluded low-energy neutrons with keeping the high LET component. The neutron capture reaction, 14N(n,p)14C, was found to be the main dose under thermal neutron-dominated conditions.
△ Less
Submitted 20 August, 2024;
originally announced August 2024.
-
Polarized cold-neutron reflectometry at JRR-3/MINE2 for the development of ultracold-neutron spin analyzers for a neutron EDM experiment at TRIUMF
Authors:
Takashi Higuchi,
Hiroaki Akatsuka,
Alexis Brossard,
Derek Fujimoto,
Pietro Giampa,
Sean Hansen-Romu,
Kichiji Hatanaka,
Masahiro Hino,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Russell Mammei,
Ryohei Matsumiya,
Kenji Mishima,
Rüdiger Picker,
Wolfgang Schreyer,
Hirohiko M. Shimizu,
Steve Sidhu,
Sean Vanbergen
Abstract:
The neutron electric dipole moment (EDM) is a sensitive probe for currently undiscovered sources of charge-parity symmetry violation. As part of the TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration, we are developing spin analyzers for ultracold neutrons (UCNs) to be used for a next-generation experiment to measure the neutron EDM with unprecedented precision. Spin-state analysis of UCNs co…
▽ More
The neutron electric dipole moment (EDM) is a sensitive probe for currently undiscovered sources of charge-parity symmetry violation. As part of the TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration, we are developing spin analyzers for ultracold neutrons (UCNs) to be used for a next-generation experiment to measure the neutron EDM with unprecedented precision. Spin-state analysis of UCNs constitutes an essential part of the neutron EDM measurement sequence. Magnetized iron films used as spin filters of UCNs are crucial experimental components, whose performance directly influences the statistical sensitivity of the measurement. To test such iron film spin filters, we propose the use of polarized cold-neutron reflectometry, in addition to conventional UCN transmission experiments. The new method provides information on iron film samples complementary to the UCN tests and accelerates the development cycles. We developed a collaborative effort to produce iron film spin filters and test them with cold and ultracold neutrons available at JRR-3/MINE2 and J-PARC/MLF BL05. In this article, we review the methods of neutron EDM measurements, discuss the complementarity of this new approach to test UCN spin filters, provide an overview of our related activities, and present the first results of polarized cold-neutron reflectometry recently conducted at the MINE2 beamline.
△ Less
Submitted 4 September, 2024; v1 submitted 21 July, 2024;
originally announced July 2024.
-
Performance of the Fully-equipped Spin Flip Chopper For Neutron Lifetime Experiment at J-PARC
Authors:
K. Mishima,
G. Ichikawa,
Y. Fuwa,
T. Hasegawa,
M. Hino,
R. Hosokawa,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
S. Matsuzaki,
T. Mogi,
H. Okabe,
T. Oku,
T. Okudaira,
Y. Seki,
H. E. Shimizu,
H. M. Shimizu,
S. Takahashi,
M. Tanida,
S. Yamashita,
M. Yokohashi,
T. Yoshioka
Abstract:
To solve the ''neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic su…
▽ More
To solve the ''neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250-400 comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in statistic will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.
△ Less
Submitted 31 July, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
Development of Neutron Interferometer using Multilayer Mirrors and Measurements of Neutron-Nuclear Scattering Length with Pulsed Neutron Source
Authors:
Takuhiro Fujiie,
Masahiro Hino,
Takuya Hosobata,
Go Ichikawa,
Masaaki Kitaguchi,
Kenji Mishima,
Yoshichika Seki,
Hirohiko M. Shimizu,
Yutaka Yamagata
Abstract:
This study entailed the successful deployment of a novel neutron interferometer that utilizes multilayer mirrors. The apparatus facilitates a precise evaluation of the wavelength dependence of interference fringes utilizing a pulsed neutron source. Our interferometer achieved an impressive precision of 0.02 rad within a 20-min of recording time. Compared to systems using silicon crystals, the meas…
▽ More
This study entailed the successful deployment of a novel neutron interferometer that utilizes multilayer mirrors. The apparatus facilitates a precise evaluation of the wavelength dependence of interference fringes utilizing a pulsed neutron source. Our interferometer achieved an impressive precision of 0.02 rad within a 20-min of recording time. Compared to systems using silicon crystals, the measurement sensitivity was maintained even when using a simplified disturbance suppressor. By segregating beam paths entirely, we achieved successful measurements of neutron-nuclear scattering lengths across various samples. The values measured for Si, Al, and Ti were in agreement with those found in the literature, while V showed a disparity of 45%. This discrepancy may be attributable to impurities encountered in previous investigations. The accuracy of measurements can be enhanced further by mitigating systematic uncertainties that are associated with neutron wavelength, sample impurity, and thickness. This novel neutron interferometer enables us to measure fundamental parameters, such as the neutron-nuclear scattering length of materials, with a precision that surpasses that of conventional interferometers.
△ Less
Submitted 5 October, 2023; v1 submitted 19 July, 2023;
originally announced August 2023.
-
A diffuse scattering model of ultracold neutrons on wavy surfaces
Authors:
S. Imajo,
H. Akatsuka,
K. Hatanaka,
T. Higuchi,
G. Ichikawa,
S. Kawasaki,
M. Kitaguchi,
R. Mammei,
R. Matsumiya,
K. Mishima,
R. Picker,
W. Schreyer,
H. M. Shimizu
Abstract:
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore d…
▽ More
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.
△ Less
Submitted 30 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Study on the reusability of fluorescent nuclear track detectors using optical bleaching
Authors:
Abdul Muneem,
Junya Yoshida,
Hiroyuki Ekawa,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Ayumi Kasagi,
Masaaki Kitaguchi,
Satoshi Kodaira,
Kenji Mishima,
Jameel-Un Nabi,
Manami Nakagawa,
Michio Sakashita,
Norihito Saito,
Takehiko R. Saito,
Satoshi Wada,
Nakahiro Yasuda
Abstract:
Fluorescent nuclear track detectors (FNTDs) based on Al${_2}$O${_3}$:C,Mg crystals are luminescent detectors that can be used for dosimetry and detection of charged particles and neutrons. These detectors can be utilised for imaging applications where a reasonably high track density, approximately of the order of 1 $\times$ $10^4$ tracks in an area of 100 $\times$ 100 $μ$m$^2$, is required. To inv…
▽ More
Fluorescent nuclear track detectors (FNTDs) based on Al${_2}$O${_3}$:C,Mg crystals are luminescent detectors that can be used for dosimetry and detection of charged particles and neutrons. These detectors can be utilised for imaging applications where a reasonably high track density, approximately of the order of 1 $\times$ $10^4$ tracks in an area of 100 $\times$ 100 $μ$m$^2$, is required. To investigate the reusability of FNTDs for imaging applications, we present an approach to perform optical bleaching under the required track density conditions. The reusability was assessed through seven irradiation-bleaching cycles. For the irradiation, the studied FNTD was exposed to alpha-particles from an $^{241}$Am radioactive source. The optical bleaching was performed by means of ultraviolet laser light with a wavelength of 355 nm. Three dedicated regions on a single FNTD with different accumulated track densities and bleaching conditions were investigated. After every irradiation-bleaching cycle, signal-to-noise ratio was calculated to evaluate FNTD performance. It is concluded that FNTDs can be reused at least seven times for applications where accumulation of a high track density is required.
△ Less
Submitted 3 November, 2022;
originally announced November 2022.
-
Investigation of the neutron imaging applications using fine-grained nuclear emulsion
Authors:
Abdul Muneem,
Junya Yoshida,
Hiroyuki Ekawa,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Ayumi Kasagi,
Masaaki Kitaguchi,
Naoto Muto,
Kenji Mishima,
Jameel-Un Nabi,
Manami Nakagawa,
Naotaka Naganawa,
Takehiko R. Saito
Abstract:
Neutron imaging is a non-destructive inspection technique with a wide range of applications. One of the important aspects concerning neutron imaging is achieving micrometer-scale spatial resolution. Developing a neutron detector with a high resolution is a challenging task. Neutron detectors, based on fine-grained nuclear emulsion, may be suitable for high resolution neutron imaging applications.…
▽ More
Neutron imaging is a non-destructive inspection technique with a wide range of applications. One of the important aspects concerning neutron imaging is achieving micrometer-scale spatial resolution. Developing a neutron detector with a high resolution is a challenging task. Neutron detectors, based on fine-grained nuclear emulsion, may be suitable for high resolution neutron imaging applications. High track density is a necessary requirement to improve the quality of neutron imaging. However, the available track analysis methods are difficult to apply under high track density conditions. Simulated images were used to determine the required track density for neutron imaging. It was concluded that a track density of the order of $10^4$ tracks per 100 $\times$ 100 $μ$m$^2$ is sufficient to utilize neutron detectors for imaging applications. The contrast resolution was also investigated for the image data sets with various track densities and neutron transmission rates. Moreover, experiments were performed for neutron imaging of the gadolinium-based gratings with known geometries. The structure of gratings was successfully resolved. The calculated 1$σ$ 10-90 \% edge response, using the gray scale optical images of the grating slit with a periodic structure of 9 $μ$m, was 0.945 $\pm$ 0.004 $μ$m.
△ Less
Submitted 6 December, 2022; v1 submitted 30 October, 2022;
originally announced October 2022.
-
The Precision nEDM Measurement with UltraCold Neutrons at TRIUMF
Authors:
Ryohei Matsumiya,
Hiroaki Akatsuka,
Chris P. Bidinosti,
Charles A. Davis,
Beatrice Franke,
Derek Fujimoto,
Michael T. W. Gericke,
Pietro Giampa,
Robert Golub,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Takashi Higuchi,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Wolfgang Klassen,
Emma Klemets,
Akira Konaka,
Elie Korkmaz,
Ekaterina Korobkina,
Florian Kuchler,
Maedeh Lavvaf
, et al. (23 additional authors not shown)
Abstract:
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are developing a new high-intensity ultracold neutron (UCN) source using su…
▽ More
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are developing a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
Study of Thin Iron Films for Polarization Analysis of Ultracold Neutrons
Authors:
Hiroaki Akatsuka,
Takashi Higuchi,
Sean Hansen-Romu,
Kichiji Hatanaka,
Tomohiro Hayamizu,
Masahiro Hino,
Go Ichikawa,
Sohei Imajo,
Blair Jamieson,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Ryohei Matsumiya,
Kenji Mishima
Abstract:
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were c…
▽ More
The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were characterized by vibrating sample magnetometry and cold-neutron reflectometry. A magnetic field required to saturate the iron film is $\sim$12 kA/m for those on the aluminum substrates and 6.4 kA/m for the silicon substrates. The magnetic potential of the iron films on the Si substrate was estimated to be 2 T by the neutron reflectometry, which is sufficient performance for an UCN polarization analyzer of the nEDM measurement.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field
Authors:
Naoto Muto,
Hartmut Abele,
Tomoko Ariga,
Joachim Bosina,
Masahiro Hino,
Katsuya Hirota,
Go Ichikawa,
Tobias Jenke,
Hiroaki Kawahara,
Shinsuke Kawasaki,
Masaaki Kitaguchi,
Jakob Micko,
Kenji Mishima,
Naotaka Naganawa,
Mitsuhiro Nakamura,
Stéphanie Roccia,
Osamu Sato,
René I. P. Sedmik,
Yoshichika Seki,
Hirohiko M. Shimizu,
Satomi Tada,
Atsuhiro Umemoto
Abstract:
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a la…
▽ More
Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either $^{7}$Li nuclei or $α$-particles, which were created when neutrons interacted with the $^{10}$B$_{4}$C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm $\times$ 0.2 mm. We created reference marks of 1 $μ$m and 5 $μ$m diameter with an interval of 50 $μ$m and 500 $μ$m, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 $\pm$ 0.08 $μ$m, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 $μ$m was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.
△ Less
Submitted 26 May, 2022; v1 submitted 12 January, 2022;
originally announced January 2022.
-
Measurement of $γ$ rays from $^6$LiF tile as an inner wall of a neutron-decay detector
Authors:
J. Koga,
S. Ieki,
A. Kimura,
M. Kitaguchi,
R. Kitahara,
K. Mishima,
N. Nagakura,
T. Okudaira,
H. Otono,
H. M. Shimizu,
N. Sumi,
S. Takada,
T. Tomita,
T. Yamada,
T. Yoshioka
Abstract:
A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress th…
▽ More
A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress the amount of $γ$ rays. In order to estimate the amount of $γ$ rays from the $^{6}{\rm LiF}$ tile, prompt gamma ray analysis (PGA) measurements were performed using germanium detectors. We reconstructed the measured $γ$-ray energy spectrum using a Monte Carlo simulation with the stripping method. Comparing the measured spectrum with a simulated one, the number of $γ$ rays emitted from the$^{6}{\rm LiF}$ tile was $(2.3^{+0.7}_{-0.3}) \times 10^{-4}$ per incident neutron. This is $1.4^{+0.5}_{-0.2}$ times the value assumed for a mole fraction of the $^{6}{\rm LiF}$ tile. We concluded that the amount of $γ$ rays produced from the $^{6}{\rm LiF}$ tile is not more twice the originally assumed value.
△ Less
Submitted 30 July, 2020;
originally announced July 2020.
-
Optimizing neutron moderators for a spallation-driven ultracold-neutron source at TRIUMF
Authors:
W. Schreyer,
C. A. Davis,
S. Kawasaki,
T. Kikawa,
C. Marshall,
K. Mishima,
T. Okamura,
R. Picker
Abstract:
We report on our efforts to optimize the geometry of neutron moderators and converters for the TRIUMF UltraCold Advanced Neutron (TUCAN) source using MCNP simulations. It will use an existing spallation neutron source driven by a 19.3 kW proton beam delivered by TRIUMF's 520 MeV cyclotron. Spallation neutrons will be moderated in heavy water at room temperature and in liquid deuterium at 20 K, and…
▽ More
We report on our efforts to optimize the geometry of neutron moderators and converters for the TRIUMF UltraCold Advanced Neutron (TUCAN) source using MCNP simulations. It will use an existing spallation neutron source driven by a 19.3 kW proton beam delivered by TRIUMF's 520 MeV cyclotron. Spallation neutrons will be moderated in heavy water at room temperature and in liquid deuterium at 20 K, and then superthermally converted to ultracold neutrons in superfluid, isotopically purified $^4$He. The helium will be cooled by a $^3$He fridge through a $^3$He-$^4$He heat exchanger. The optimization took into account a range of engineering and safety requirements and guided the detailed design of the source. The predicted ultracold-neutron density delivered to a typical experiment is maximized for a production volume of 27 L, achieving a production rate of $1.4 \cdot 10^7$ s$^{-1}$ to $1.6 \cdot 10^7$ s$^{-1}$ with a heat load of 8.1 W. At that heat load, the fridge can cool the superfluid helium to 1.1 K, resulting in a storage lifetime for ultracold neutrons in the source of about 30 s. The most critical performance parameters are the choice of cold moderator and the volume, thickness, and material of the vessel containing the superfluid helium. The source is scheduled to be installed in 2021 and will enable the TUCAN collaboration to measure the electric dipole moment of the neutron with a sensitivity of $10^{-27}$ e cm.
△ Less
Submitted 22 January, 2020; v1 submitted 15 December, 2019;
originally announced December 2019.
-
Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement
Authors:
R. Kitahara,
K. Hirota,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
J. Koga,
K. Mishima,
A. Morishita,
N. Nagakura,
H. Oide,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
K. Taketani,
T. Tomita,
T. Yamada,
S. Yamashita,
M. Yokohashi,
T. Yoshioka
Abstract:
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of…
▽ More
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement.
In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.
△ Less
Submitted 2 August, 2019; v1 submitted 26 April, 2019;
originally announced April 2019.
-
Neutron scattering cross section of diamond nanoparticle
Authors:
Kenji Mishima,
Toshiya Otomoa,
Kazutaka Ikeda,
Hidetoshi Ohshita
Abstract:
Due to their large coherent scattering cross section, diamond nanoparticles (DNPs) are considered as a promising candidate material for a new neutron reflector. For investigation of scattering cross sections of packed samples, we have developed a technique for mechanical compression of DNP powder. Application of 220 MPa allowed us to increase the bulk density from 0.40 g/cm$^3$ to 1.1 g/cm$^3$. Th…
▽ More
Due to their large coherent scattering cross section, diamond nanoparticles (DNPs) are considered as a promising candidate material for a new neutron reflector. For investigation of scattering cross sections of packed samples, we have developed a technique for mechanical compression of DNP powder. Application of 220 MPa allowed us to increase the bulk density from 0.40 g/cm$^3$ to 1.1 g/cm$^3$. The differential cross sections of uncompressed and packed samples were measured using the high-intensity total diffractometer instrument NOVA at J-PARC, covering transfer wavenumbers (q) from 0.6 to 100 nm$^{-1}$. The q dependence for the compressed sample agreed with the theoretical expectation derived from the Born approximation applied to homogeneous spheres with inclusion of a hard-sphere model to account for the inter-particle structure, whereas the results obtained from the powder sample disagreed. This implies that the theoretical description does not well represent the mesoscopic structure of the DNP powder sample.
△ Less
Submitted 16 July, 2020; v1 submitted 9 November, 2018;
originally announced November 2018.
-
First ultracold neutrons produced at TRIUMF
Authors:
S. Ahmed,
E. Altiere,
T. Andalib,
B. Bell,
C. P. Bidinosti,
E. Cudmore,
M. Das,
C. A. Davis,
B. Franke,
M. Gericke,
P. Giampa,
P. Gnyp,
S. Hansen-Romu,
K. Hatanaka,
T. Hayamizu,
B. Jamieson,
D. Jones,
S. Kawasaki,
T. Kikawa,
M. Kitaguchi,
W. Klassen,
A. Konaka,
E. Korkmaz,
F. Kuchler,
M. Lang
, et al. (28 additional authors not shown)
Abstract:
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this so…
▽ More
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.
△ Less
Submitted 16 December, 2018; v1 submitted 10 September, 2018;
originally announced September 2018.
-
Accurate determination of the absolute 3He/4He ratio of a synthesized helium standard gas (Helium Standard of Japan, HESJ): Towards revision of the atmospheric 3He/4He ratio
Authors:
Kenji Mishima,
Hirochika Sumino,
Takahito Yamada,
Sei Ieki,
Naoki Nagakura,
Hidetoshi Otono,
Hideyuki Oide
Abstract:
The helium standard of Japan, referred to as HESJ, is an inter-laboratory standard for the 3He/4He ratio. While the ratio of 3He and 4He of the HESJ was previously determined by a relative comparison to atmospheric helium, the absolute value of the 3He/4He ratio of the HESJ has not been directly determined yet. Therefore, it relies on the early measurements of that of atmospheric helium. The accur…
▽ More
The helium standard of Japan, referred to as HESJ, is an inter-laboratory standard for the 3He/4He ratio. While the ratio of 3He and 4He of the HESJ was previously determined by a relative comparison to atmospheric helium, the absolute value of the 3He/4He ratio of the HESJ has not been directly determined yet. Therefore, it relies on the early measurements of that of atmospheric helium. The accuracy of the absolute 3He/4He ratios of the atmosphere and other working standards including HESJ is crucial in some applications of helium isotopes, such as tritium-3He dating, surface-exposure age determination based on cosmogenic 3He, and the accurate measurement of the neutron lifetime. In this work, new control samples of helium gases with 3He/4He ratios of 14, 28, and 42 ppm were fabricated with accuracy of 0.25-0.38% using a gas-handling system for a neutron lifetime experiment at Japan Proton Accelerator Research Complex (J-PARC). The relative 3He/4He ratios of these samples and the HESJ were measured using a magnetic-sector-type, single-focusing, noble gas mass spectrometer with a double collector system. As a result, the absolute 3He/4He ratio of the HESJ was determined as 27.36 +/- 0.11 ppm. The atmospheric 3He/4He ratio was determined as 1.340 +/- 0.006 ppm, based on this work.
△ Less
Submitted 2 October, 2018; v1 submitted 21 April, 2018;
originally announced April 2018.
-
A Cold/Ultracold Neutron Detector using Fine-grained Nuclear Emulsion with Spatial Resolution less than 100 nm
Authors:
N. Naganawa,
T. Ariga,
S. Awano,
M. Hino,
K. Hirota,
H. Kawahara,
M. Kitaguchi,
K. Mishima,
H. M. Shimizu,
S. Tada,
S. Tasaki,
A. Umemoto
Abstract:
A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C layer for the neutron conversion. The detector was exposed to cold and ultracold neutrons (UCNs) at the J-PARC. Detection efficiencies were measured as (0.16…
▽ More
A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C layer for the neutron conversion. The detector was exposed to cold and ultracold neutrons (UCNs) at the J-PARC. Detection efficiencies were measured as (0.16$\pm$0.02)% and (12$\pm$2)% for cold and ultracold neutrons consistently with the $^{10}$B content in the converter. Positions of individual neutrons can be determined by observing secondary particle tracks recorded in the nuclear emulsion. The spatial resolution of incident neutrons were found to be in the range of 11-99 nm in the angle region of tan$θ\leq 1.9$, where $θ$ is the angle between a recorded track and the normal direction of the converter layer. The achieved spatial resolution corresponds to the improvement of one or two orders of magnitude compared with conventional techniques and it is comparable with the wavelength of UCNs.
△ Less
Submitted 1 March, 2018;
originally announced March 2018.
-
Fundamental physics activities with pulsed neutron at J-PARC(BL05)
Authors:
Kenji Mishima,
Shogo Awano,
Yasuhiro Fuwa,
Fumiya Goto,
Christopher C. Haddock,
Masahiro Hino,
Masanori Hirose,
Katsuya Hirota,
Sei Ieki,
Sohei Imajo,
Takashi Ino,
Yoshihisa Iwashita,
Ryo Katayama,
Hiroaki Kawahara,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Jun Koga,
Aya Morishita,
Tomofumi Nagae,
Naoki Nagakura,
Naotaka Naganawa,
Noriko Oi,
Hideyuki Oide,
Hidetoshi Otono,
Yoshichika Seki
, et al. (15 additional authors not shown)
Abstract:
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The…
▽ More
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The neutron lifetime is an important parameter in elementary particle and astrophysics. Thus far, the neutron lifetime has been measured by several groups; however, different values are obtained from different measurement methods. This experiment is using a method with different sources of systematic uncertainty than measurements conducted to date. We are also developing a source of pulsed ultra-cold neutrons (UCNs) produced from a Doppler shifter are available at the unpolarized beam branch. We are developing a time focusing device for UCNs, a so called "rebuncher", which can increase UCN density from a pulsed UCN source. At the low divergence beam branch, an experiment to search an unknown intermediate force with nanometer range is performed by measuring the angular dependence of neutron scattering by noble gases. Finally the beamline is also used for the research and development of optical elements and detectors. For example, a position sensitive neutron detector that uses emulsion to achieve sub-micrometer resolution is currently under development. We have succeeded in detecting cold and ultra-cold neutrons using the emulsion detector.
△ Less
Submitted 25 January, 2018; v1 submitted 18 December, 2017;
originally announced December 2017.
-
A Search for deviations from the inverse square law of gravity at nm range using a pulsed neutron beam
Authors:
Christopher C. Haddock,
Noriko Oi,
Katsuya Hirota,
Takashi Ino,
Masaaki Kitaguchi,
Satoru Matsumoto,
Kenji Mishima,
Tatsushi Shima,
Hirohiko M. Shimizu,
W. Michael Snow,
Tamaki Yoshioka
Abstract:
We describe an experimental search for deviations from the inverse square law of gravity at the nanometer length scale using neutron scattering from noble gases on a pulsed slow neutron beamline. By measuring the neutron momentum transfer ($q$) dependence of the differential cross section for xenon and helium and comparing to their well-known analytical forms, we place an upper bound on the streng…
▽ More
We describe an experimental search for deviations from the inverse square law of gravity at the nanometer length scale using neutron scattering from noble gases on a pulsed slow neutron beamline. By measuring the neutron momentum transfer ($q$) dependence of the differential cross section for xenon and helium and comparing to their well-known analytical forms, we place an upper bound on the strength of a new interaction as a function of interaction length $λ$ which improves upon previous results in the region $λ< 0.1\,$nm, and remains competitive in the larger $λ$ region. A pseudoexperimental simulation developed for this experiment and its role in the data analysis described. We conclude with plans for improving sensitivity in the larger $λ$ region.
△ Less
Submitted 21 February, 2018; v1 submitted 8 December, 2017;
originally announced December 2017.
-
Precise Neutron Lifetime Measurement with a Solenoidal Coil
Authors:
Naoyuki Sumi,
Hidetoshi Otono,
Tamaki Yoshioka,
Kenji Mishima,
Yasuhiro Makida
Abstract:
The neutron lifetime, $τ$ = 880.2 $\pm$ 1.0 sec , is an important parameter for particle physics and cosmology. There is, however, an 8.4 sec (4.0$\,σ$) deviation between the measured value of the neutron lifetime using two methods : one method counts neutrons that survive after some time, while the other counts protons resulting from neutron beta decay. A new method is being implemented at J-PARC…
▽ More
The neutron lifetime, $τ$ = 880.2 $\pm$ 1.0 sec , is an important parameter for particle physics and cosmology. There is, however, an 8.4 sec (4.0$\,σ$) deviation between the measured value of the neutron lifetime using two methods : one method counts neutrons that survive after some time, while the other counts protons resulting from neutron beta decay. A new method is being implemented at J-PARC / MLF / BL05 using a pulsed cold neutron beam. A Time Projection Chamber (TPC) records both the electrons from neutron beta decay and protons from the neutron-$^3$He capture reactions in order to estimate the neutron flux. Electron background signals require the largest correction and are source of uncertainty for this experiment. A solenoidal magnetic field can greatly reduce this background. The TPC drift region must be divided into three region in this case. A prototype detector was developed to study the multi drift layer TPC. The status of a study using a prototype detector is reported in this paper.
△ Less
Submitted 13 January, 2018; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Precise neutron lifetime experiment using pulsed neutron beams at J-PARC
Authors:
Naoki Nagakura,
Katsuya Hirota,
Sei Ieki,
Takashi Ino,
Yoshihisa Iwashita,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Kenji Mishima,
Aya Morishita,
Hideyuki Oide,
Hidetoshi Otono,
Risa Sakakibara,
Yoshichika Seki,
Tatsushi Shima,
Hirohiko M. Shimizu,
Tomoaki Sugino,
Naoyuki Sumi,
Hiroshima Sumino,
Kaoru Taketani,
Genki Tanaka,
Tatsuhiko Tomita,
Takahito Yamada,
Satoru Yamashita,
Mami Yokohashi,
Tamaki Yoshioka
Abstract:
The neutron lifetime is one of the basic parameters in the weak interaction, and is used for predicting the light element abundance in the early universe. Our group developed a new setup to measure the lifetime with the goal precision of 0.1% at the polarized beam branch BL05 of MLF, J-PARC. The commissioning data was acquired in 2014 and 2015, and the first set of data to evaluate the lifetime in…
▽ More
The neutron lifetime is one of the basic parameters in the weak interaction, and is used for predicting the light element abundance in the early universe. Our group developed a new setup to measure the lifetime with the goal precision of 0.1% at the polarized beam branch BL05 of MLF, J-PARC. The commissioning data was acquired in 2014 and 2015, and the first set of data to evaluate the lifetime in 2016, which is expected to yield a statistical uncertainty of O(1)%. This paper presents the current analysis results and the future plans to achieve our goal precision.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
A neutron detector with spatial resolution of submicron using fine-grained nuclear emulsion
Authors:
N. Naganawa,
S. Awano,
M. Hino,
M. Hirose,
K. Hirota,
H. Kawahara,
M. Kitaguchi,
K. Mishima,
T. Nagae,
H. M. Shimizu,
S. Tasaki,
A. Umemoto
Abstract:
We have been developing a neutron detector with spatial resolution of submicron by loading 6Li into fine-grained nuclear emulsion. By exposure to thermal neutrons, tracks from neutron capture events were observed. From their grain density, spatial resolution was estimated. Detection efficiency was also measured by an experiment with cold neutrons.
We have been developing a neutron detector with spatial resolution of submicron by loading 6Li into fine-grained nuclear emulsion. By exposure to thermal neutrons, tracks from neutron capture events were observed. From their grain density, spatial resolution was estimated. Detection efficiency was also measured by an experiment with cold neutrons.
△ Less
Submitted 14 December, 2016;
originally announced December 2016.
-
Pulsed UCN production using a Doppler shifter at J-PARC
Authors:
S. Imajo,
K. Mishima,
M. Kitaguchi,
Y. Iwashia,
N. L. Yamada,
M. Hino,
T. Oda,
T. Ino,
H. M. Shimizu,
S. Yamashita,
R. Katayama
Abstract:
We have constructed a Doppler-shifter-type pulsed ultra-cold neutron (UCN) source at the Materials and Life Science Experiment Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). Very-cold neutrons (VCNs) with 136-$\mathrm{m/s}$ velocity in a neutron beam supplied by a pulsed neutron source are decelerated by reflection on a m=10 wide-band multilayer mirror, yielding pulsed U…
▽ More
We have constructed a Doppler-shifter-type pulsed ultra-cold neutron (UCN) source at the Materials and Life Science Experiment Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). Very-cold neutrons (VCNs) with 136-$\mathrm{m/s}$ velocity in a neutron beam supplied by a pulsed neutron source are decelerated by reflection on a m=10 wide-band multilayer mirror, yielding pulsed UCN. The mirror is fixed to the tip of a 2,000-rpm rotating arm moving with 68-$\mathrm{m/s}$ velocity in the same direction as the VCN. The repetition frequency of the pulsed UCN is $8.33~\mathrm{Hz}$ and the time width of the pulse at production is $4.4~\mathrm{ms}$. In order to increase the UCN flux, a supermirror guide, wide-band monochromatic mirrors, focus guides, and a UCN extraction guide have been newly installed or improved. The $1~\mathrm{MW}$-equivalent count rate of the output neutrons with longitudinal wavelengths longer than $58~\mathrm{nm}$ is $1.6 \times 10^{2}~\mathrm{cps}$, while that of the true UCNs is $80~\mathrm{cps}$. The spatial density at production is $1.4~\mathrm{UCN/cm^{3}}$. This new UCN source enables us to research and develop apparatuses necessary for the investigation of the neutron electric dipole moment (nEDM).
△ Less
Submitted 25 November, 2015; v1 submitted 26 July, 2015;
originally announced July 2015.
-
Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams
Authors:
Y. Arimoto,
N. Higashi,
Y. Igarashi,
Y. Iwashita,
T. Ino,
R. Katayama,
R. Kitahara,
M. Kitaguchi,
H. Matsumura,
K. Mishima,
H. Oide,
H. Otono,
R. Sakakibara,
T. Shima,
H. M. Shimizu,
T. Sugino,
N. Sumi,
H. Sumino,
K. Taketani,
G. Tanaka,
M. Tanaka,
K. Tauchi,
A. Toyoda,
T. Yamada,
S. Yamashita
, et al. (2 additional authors not shown)
Abstract:
A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as…
▽ More
A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.
△ Less
Submitted 11 September, 2015; v1 submitted 26 March, 2015;
originally announced March 2015.