The Mini-CAPTAIN Liquid Argon Time Projection Chamber
Authors:
CAPTAIN Collaboration,
C. E. Taylor,
B. Bhandari,
J. Bian,
K. Bilton,
C. Callahan,
J. Chaves,
H. Chen,
D. Cline,
R. L. Cooper,
D. L. Danielson,
J. Danielson,
N. Dokania,
S. Elliot,
S. Fernandes,
S. Gardiner,
G. Garvey,
V. Gehman,
F. Giuliani,
S. Glavin,
M. Gold,
C. Grant,
E. Guardincerri,
T. Haines,
A. Higuera
, et al. (51 additional authors not shown)
Abstract:
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryost…
▽ More
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
First Measurement of the Total Neutron Cross Section on Argon Between 100 and 800 MeV
Authors:
B. Bhandari,
J. Bian,
K. Bilton,
C. Callahan,
J. Chaves,
H. Chen,
D. Cline,
R. L. Cooper,
D. Danielson,
J. Danielson,
N. Dokania,
S. Elliott,
S. Fernandes,
S. Gardiner,
G. Garvey,
V. Gehman,
F. Giuliani,
S. Glavin,
M. Gold,
C. Grant,
E. Guardincerri,
T. Haines,
A. Higuera,
J. Y. Ji,
R. Kadel
, et al. (51 additional authors not shown)
Abstract:
We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided…
▽ More
We report the first measurement of the neutron cross section on argon in the energy range of 100-800 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. The total cross section is measured from the attenuation coefficient of the neutron flux as it traverses the liquid argon volume. A set of 2,631 candidate interactions is divided in bins of the neutron kinetic energy calculated from time-of-flight measurements. These interactions are reconstructed with custom-made algorithms specifically designed for the data in a time projection chamber the size of the Mini-CAPTAIN detector. The energy averaged cross section is $0.91 \pm{} 0.10~\mathrm{(stat.)} \pm{} 0.09~\mathrm{(sys.)}~\mathrm{barns}$. A comparison of the measured cross section is made to the GEANT4 and FLUKA event generator packages.
△ Less
Submitted 26 June, 2019; v1 submitted 12 March, 2019;
originally announced March 2019.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
The CAPTAIN Detector and Physics Program
Authors:
The CAPTAIN Collaboration,
H. Berns,
H. Chen,
D. Cline,
J. Danielson,
Z. Djurcic,
S. Elliott,
G. Garvey,
V. Gehman,
C. Grant,
E. Guardincerri,
R. Kadel,
T. Kutter,
D. Lee,
K. Lee,
Q. Liu,
W. Louis,
C. Mauger,
C. McGrew,
R. McTaggart,
J. Medina,
W. Metcalf,
G. Mills,
J. Mirabal-Martinez,
S. Mufson
, et al. (22 additional authors not shown)
Abstract:
The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented wi…
▽ More
The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented with a 2,000 channel liquid argon TPC and a photon detection system. Subsequent to the commissioning phase, the detector will collect data in a high-energy neutron beamline that is part of the Los Alamos Neutron Science Center to measure cross-sections of spallation products that are backgrounds to measurements of neutrinos from a supernova burst, cross-sections of events that mimic the electron neutrino appearance signal in long-baseline neutrino physics and neutron signatures to constrain neutrino energy reconstruction in LBNE's long-baseline program. Subsequent to the neutron running, the CAPTAIN detector will be moved to a neutrino source. Two possibilities are an on-axis run in the NuMI beamline at FNAL and a run in the neutrino source produced by the SNS. An on-axis run at NuMI produces more than one million events of interest in a two or three year run at neutrino energies between 1 and 10 GeV - complementary to the MicroBooNE experiment, which will measure similar interactions at a lower energy range - 0.5 to 2 GeV. At the SNS the neutrinos result from the decays stopped positively charged pions and muons yielding a broad spectrum up to 50 MeV. If located close to the spallation target, CAPTAIN can detect several thousand events per year in the same neutrino energy regime where neutrinos from a supernova burst are. Measurements at the SNS yield a first measurement of the cross- section of neutrinos on argon in this important energy regime.
△ Less
Submitted 6 September, 2013;
originally announced September 2013.